Laserfiche WebLink
<br />e <br /> <br />EXHIBIT "A" <br /> <br />e <br /> <br />TurnerCollie@'Braden Inc. <br /> <br />Engineers · Planners · Project Managers <br /> <br />P.O. Box 130089 <br />Hou5lon. Texas n:!IQ-0089 <br />3737 Woodwav 7;'037.1399 <br />713 780~100 <br />Fax 713 780.0838 <br /> <br />September 4, 1997 <br /> <br />Mr. John Joems <br />City of La Porte <br />604 West Fairmont Parkway <br />p, 0, Box 1115 <br />La Porte, Texas 77572-1115 <br /> <br />Attention: <br /> <br />Mr, Douglas K, Kneupper, P,E, <br />City Engineer <br /> <br />Re: Proposal for Preliminary Engineering Services <br />for a Sanitary Sewer Trunk Main and Lift Station Facilities <br />to Serve Undeveloped Areas Adjacent to the Weems Tract <br />TC&B Job No, 13-01997-999, Task 0009 <br /> <br />Gentlemen: <br /> <br />Turner Collie & Braden !nc, (TC&B) is pleased to submit this proposal to perform <br />preliminary engineering services relating to the design of a Sanitary Sewer Trunk Main and <br />Lift Station Facilities to serve undeveloped areas adjacent to the Weems Tract and future flow <br />diversion from the former BayMUD area. It is our understanding that the proposed <br />improvements will be designed to satisfy the conditions described below. The facilities <br />location and alignment, tract ownership and lift station designations referred to herein are <br />based on the exhibit entitled "Proposed Sanitary Sewer for New Development", provided by <br />the City of La Porte. <br /> <br />1. The proposed trunk sewer will be tied to the existing 21-inch sanitary sewer adjacent to <br />the L.C,B. Park area, <br /> <br />2. The trunk sewer will be constructed along the boundary of the existing golf course and <br />future \Veems tract alignment. <br /> <br />3, A lift station facility will be constructed along McCabe which will allow the future <br />abandonment of existing 1.S, 12, as well as provide sufficient capacity for future tie-in <br />from L.S, 40, L.S, 40 presently receives flows from the former BayMUD, with <br />discharge to the Gulf Coast Waste Disposal Authority Plant. <br /> <br />4. Existing L.S, 6 and its force main, as well as the downstream discharge sewer, will be <br />analyzed to determine if it can be enlarged to handle the additional flow. It is our <br />understanding that 1.S. 6 is located in the road right-of-way and therefore may require <br />acquisition of property to encompass the improvements. <br /> <br />;: " .~ in\" .~ ~ . , ~ ~.: : co ~ f"! 1~'. i I~. .; <br /> <br />".,. ....: <br /> <br />TEXAS -\L'STIi'\ I DALLAS! FORT WORTH.' HOUSTON/RIO GRANDE '. ,~.LLEY COLORADO DENVER <br />