<br />(b). Doorways opening onto a street or to a court or open <br />space communicating with a street, and serving as a required exit <br />way for more than 40 persons shall have the doors, including the <br />doors of vestibules, so hung as to swing open in the direction of exit <br />travel; but this requirement shall not be construed to prohibit the <br />use of sliding doors in stables, garages, or shipping and receiving <br />rooms of business buildings and storage buildings. . <br />(c). All exit doors in rooms occupied by 40 or more persons <br />and al1 exit doors in exit ways from places of assembly shal1 be hung <br />to swing open in tqe direction of exit travel. <br />(d). No exit door shall open immediately on a flight of stairs, <br />a landing the length and width of which are not less than the <br /> <br />16 <br /> <br />but <br /> <br />. <br /> <br />. <br /> <br />21 <br /> <br />Unprotected metal construction, as applied to buildings, means <br />that in which the structural supports are unprotected metal and in <br />which floors and roofs are of noncombustible construction, and the <br />exterior walls are of noncombustible construction having a fire re- <br />sistance rating of less than 2 hours. <br /> <br />9. Firestopping. <br />(a). Exterior walls of wood frame construction shall be prop- <br />erly firestopped at each floor level, at the top story ceiling level, at <br />the roof level in the case of flat roofs, and at the foot of roof rafters <br />in the case of sloping roofs. <br />(b). Joists shall be firestopped at the ends and over supports <br />for the full depth of the joists. <br />(c). Interior stud partitions shall be firestopped at the floor <br />and ceiling of each story by a 2-inch, nominal dimension, wood <br />plate, the width of the stud, or the equivalent. <br />(d). When sliding doors are pocketed in partitions, such <br />pockets shall be completely firestopped at the top, bottom and ends. <br />(e). Firestopping shall be of noncombustible material or of <br />wood not less than 2 inches in thickness, nominal dimension. No <br />firestopping shall be covered or concealed until inspected by the <br />building official. <br /> <br />10. Draft stops in attic spaces. Draft stops shall <br />in attic spaces as required by section 17-10. <br /> <br />J <br /> <br />SECTION <br />TION. <br /> <br />20. <br /> <br />UNPROTECTED METAL CONSTRUC- <br /> <br />be provided <br /> <br />13. Hanging of doors. <br /> <br />(a). The doors of required doorways shall be so hung and ar- <br />ranged that when fully opened they will not in any way diminish <br />or obstruct the required width of hallway, stair, or other means of <br />exit. <br /> <br />11. Exit hallways. The clear width of every hallway or pas- <br />sage leading to a required exit shall be not less than at the rate of 12 <br />inches for every 100 persons to be accommodated by the hallway but <br />not less than 44 inches; provided that in multifamily houses or in <br />case less than 40 persons are to be accommodated, the minimum <br />clear width may be 36 i,nches. <br /> <br />12. Width of doorways. The aggregate clear width of door- <br />ways serving as required exits shall be not less than at the rate of 22 <br />inches for every 100 persons to be accommodated. No exit doorway <br />serving as an exit for more than 40 persons shall have a clear width <br />of less than 34 inches (nominal 36-inch door.) <br /> <br />. <br /> <br />. <br /> <br />to. Handrails. <br />(a). Except for steps in aisles, stairs shall have <br />secured balustrades or guards on both sides. <br />(b). Such stairs when less than 44 inches in width shall <br />handrails on at least one side. <br />(c). Such stairs when required to be 44 inches or more <br />width shall have handrails on both sides. <br />(d). When the required width of a flight of stairs exceeds 88 <br />inches, an intermediate handrail, continuous between landings, se- <br />curely supported and terminating at the upper end in newels or <br />standards at least 6 feet high, with no projections, shall be pro- <br />vided. <br /> <br />8. Wooden columns shall <br />tion 17-6. <br /> <br />conform <br /> <br />to <br /> <br />the requirements of sec- <br /> <br />111 <br /> <br />7. Load-bearing partitions shall <br />of section 17-5. <br /> <br />6. Beams, girders and joists shall conform to the requirements <br />of section 17-3, paragraphs (a) to (d) inclusive. Where ledger <br />or ribbon boards are used to support joists, such boards shall be <br />not less than 1 x 4 inch, nominal dimensions, shall be cut into the <br />studs and securely nailed with not less than 2 tenpenny nails to each <br />stud, and the joists shall be spiked to the studs. <br /> <br />conform to <br /> <br />the <br /> <br />requirements <br /> <br />9. Landings. <br />(a). No flight of stairs shall have a vertical rise of more than <br />12 feet. between floors or landings; except "that in stairways serving <br />as exits in public buildings such vertical rise shall not exceed 8 feet. <br />(b). The length and width of landings shall be not less than <br />the width of stairways in which they occur. <br /> <br />walls <br /> <br />or <br /> <br />have <br /> <br />wel <br /> <br />5. Anchorage. <br />(a). In all buildings 20 feet or more in width where joists run <br />at right angles to the rafters, the rafters shall be tied to the ceiling <br />joists with wood or metal ties nailed to the foot of alternate rafters <br />and extending across 4 joists well nailed to each joist. <br />(b). All joists shall be well lapped and nailed across the build- <br />ing to form ties between outside walls. <br /> <br />. <br /> <br />. <br /> <br />risers may, in the discretion. the building official, be adjusted to <br />suit the age of the pupils for which the school is intended. Treads <br />and risers shall be of uniform width and height in anyone story. <br />(b). The use of winders is prohibited in required stairways. <br /> <br />e <br /> <br />e <br /> <br />(c). Corrosion-resistant flasl, to prevent moisture from <br />penetrating behind the stucco, shall be provided over wall openings <br />and over projecting COurses. <br /> <br />4. Sills. Sills shall be anchored to the foundation walls at <br />intervals not exceeding 6 feet by anchors equivalent to bolts not less <br />than 0 inch in diameter with proper washers, embedded at least 6 <br />inches in the foundation. <br />
The URL can be used to link to this page
Your browser does not support the video tag.