<br />14 <br /> <br />5. Location of exit doorways. Exit doorways shall be so lo- <br />cated that no point in a floor area, room or space served by them is <br />more than 100 feet distant from an exit doorway, measured along <br />the line of travel; except that when a floor area is subdivided into <br />smaller areas, such as rooms in hotels, multifamily houses, and <br />office buildings, the distance from the door of any room, along an <br />unobstructed hallway, to an exit doorway, shall. be not more than <br />125 feet, except that hallways above the first story shall not extend <br />beyond an exit as a dead end more than 50 feet. Where the build- <br />ing is of fireproof construction or semifireproof construction, or the <br />building is sprinklered, the above distances may be increa~ed 50 <br />per cent. <br /> <br />. <br /> <br />.j <br /> <br />. <br /> <br />23 <br /> <br />* As defined in Federal Specification SS-C-ISI b, Masonry Cement. <br /> <br />(b). Type of mortar required. Masonry shall be laid in Type <br />A, Type B or Type C mortar, except as follows: <br />Type A mortar shall be used in foundation walls of hollow <br />masonry units, and in nominal to-inch cavity walls. <br />Type A or Type B mortar shall be used in footings, foundation <br />walls of solid masonry units, isolated piers, load bearing or exterior <br />walls of hollow masonry units, hollow walls and cavity walls ex- <br />ceeding lO-inch nominai thickness. <br />Type D mortar may be used in solid masonry walls, other <br />than parapet walls or rubble stone walls, not in contact with the <br /> <br />(c). Apartments. In multifamily houses exceeding two <br />stories above the basement, and in every two-story multifamily hOllse <br />having more than 6 apartments using a common exit way, every <br />apartment that has not direct exit to a street or to a court opening on <br />a street, shall have access to at least one additional exit way sepa- <br />rated from and independent of the primary interior stairway or fire <br />tower. <br /> <br />C. <br />D <br /> <br />B <br />C <br /> <br />I (Masonry <br />Type 1*) <br />o to ~ (Port- <br />land) <br /> <br />(Masonry <br />Type II*) <br />(Pprtland) <br /> <br />o <br />1 to <br /> <br />o <br />2 to 2~ <br /> <br />I~ <br /> <br />Not over 3 parts <br /> <br />Not <br /> <br />Not over 9 parts <br /> <br />over 3 parts <br /> <br />(b). From stories. Every story shall have at least one exit <br />way and every story that exceeds 2,500 square feet in area shall have <br />at least two separate exit way,s. <br /> <br />A <br />B <br /> <br />I <br />1 <br /> <br />(Portland) <br />(Portland) <br /> <br />o to ~ <br />I to I~ <br /> <br />Not over 3 parts <br /> <br />Not over 3 parts <br />Not over 6 parts <br /> <br />OCCUPANCY <br />Dance hall, lodge room, or place of assembly <br />Store-street floor and sales basement. <br />other floors ........... <br />Space used for occupancies <br />Public ..... <br />Institutional <br />Residence <br />Business <br />Storage <br /> <br />4. Number of Exits. <br /> <br />(a). From rooms. Every room having an area exceeding <br />square feet or occupied by more than 100 persons shall have at <br />two exit ways. <br /> <br />1,000 . <br />least . <br /> <br />. <br /> <br />Cement <br /> <br />Hydrated <br />Lime or <br />Lime <br />Putty <br /> <br />Aggregate, <br />measured in a <br />damp and loose <br />condition <br /> <br />Mortar <br />type <br /> <br />40 <br />150 <br />125 <br />100 <br />300 <br /> <br />" <br />" <br />" <br />" <br />" <br /> <br />" <br />" <br />" <br />" <br />" <br /> <br />Proportions by Volume <br /> <br />solidly filled with concrete or T' A mortar in <br />allowable load may be increased 25 per cent. <br />(f). Door and window openings in walls shall be spanned by <br />well buttressed arches, or by lintels having bearings proportioned <br />to their loads but not less than 4 inches: <br />(g). No masonry, except for interior partitions, shall be sup- <br />ported on wooden girders or other form of wood construction. <br />(h). No timber, other than nailing blocks not exceeding 2 by 4 <br />by 8 inches in size, shall be placed in masonry walls; except that in <br />buildings of ordinary construction, timber lintels may be placed <br />over openings, on the inside of the wall, resting at each end not more <br />than two inches on the wall, and chamfered or cut to serve as <br />centres for masonry arches; and with the further exception that <br />timber members used for decorative purposes may be set against <br />the masonry, or may be set into the masonry where the wall exceeds <br />8 inches in thickness. <br />(i). During erection, walls shall <br />arches temporarily supported. <br /> <br />Mortar. <br /> <br />Mortar <br /> <br />2. <br />(a). Mortar used in <br />tioned in accordance with <br /> <br />Proportions <br /> <br />masonry construction <br />the following table <br /> <br />not <br /> <br />listed above <br /> <br />GROSS AREA <br />PER PERSON <br />15 Sq. Ft. <br />30" " <br />60" " <br /> <br />.1 <br /> <br />shall <br /> <br />be <br /> <br />propor- <br /> <br />3. Number of occupants. <br />(a). The dimensions and capacity of exit ways shall <br />portioned to the number of persons to be accommodated. <br />(b). When the number of persons to be accommodated by the <br />exit way is not stated in the application for a permit or is not other- <br />wise fixed, it shall be decided on the basis of the gross area of the <br />space devoted to a particular purpose and shall be assumed to be as <br />follows: <br /> <br />be <br /> <br />adequately braced and <br /> <br />be pro- <br /> <br />open space which' provide~fe access to a street. Exit ways <br />from any room may lead through other rooms of the same tenancy. <br />(b). Two or more separate exit ways may use the same corri- <br />r hallway; provided that such corridor or hallway is enclosed <br />d separated from exit stairways and other parts of the building <br />rtitions having a fire resistance rating of not less than one hour. <br /> <br />dor 0 <br />by an <br />bypa <br /> <br />. <br /> <br />e <br /> <br />. <br /> <br />e <br /> <br />which <br /> <br />case <br /> <br />the <br />
The URL can be used to link to this page
Your browser does not support the video tag.