Laserfiche WebLink
<br />(c). Outside the congested areas of the municipality, when a <br />hazardous condition is not created thereby, the area of a public <br />building, a business building or a storage building, not over two <br />stories high, may be increased in excess of the areas fixed by this <br />section, in the discretion of the governing body of the municipality; <br />provided that a building of combustible occupancy, or involving con- <br />siderable cOinbustible iliaterial in its structural parts, shall be <br />sprinklered, and also curtain boards or draft stops shall be installed <br />as required by the building official. <br /> <br />12 <br /> <br />. <br /> <br />,~ <br /> <br /> <br />I <br />u, <br /> <br />. <br /> <br />(b). Outside the fire limits the area of one-story buildings of <br />heavy timber construction, ordinary construction and wood frame <br />construction may be increased 33 % per cent above the areas other- <br />wise fixed in this section, when all wood structural members, in- <br />cluding columns, wall and partition studs and sheathing, and floor <br />and roof construction, are of approved fire retardant treated lumber <br />as defined in section 7. <br /> <br />(c). Bond. <br />(1) In ashlar masonry, bond stones uniformly distributed shall <br />be provided to the extent of not less than 10 per cent of the area <br />and having not less than 4 inches of bond into the backing masonry. <br />(2) Rubble stone masonry 24 inches or less in thickness shall <br />have bond stones with a maximum spacing of 3 feet vertically and <br />horizontally, and if the masonry is of greater thickness than 24 <br />inches shall have one bond stone for each 6 square feet of wall surface <br />on both sides and no header stone shall be less than 12 inches long <br />measured at right angles to the face of the masonry. <br />(d). Natural Beds. All stones showing pronounced cleavage <br />shaH be iaid on their natural bed, except for cornices and otht:r pru- <br />jecting members which shall have the grain or bedding planes verti- <br />cal and at right angles to the face of the masonry. <br /> <br />25 <br /> <br />(a). The limiting areas fixed in this section may be increased <br />by 100 per cent when the building is sprinklered, and by 200 per <br />cent when the building is sprinklered and does not exceed one story <br />nor an average of 25 feet in height to the roof, or to a fire retardant <br />ceiling through which there shall be no openings except openings <br />into shafts or ducts, the enclosing walls of which are of construc~ion <br />equivalent to the ceiling. <br /> <br />(2) Rubble stone walls shall be 4 inches thicker than is re- <br />quired for solid masonry walls in subsection 3 of this section, but <br />shall not be less than 16 inches thick, and shall not exceed 40 feet <br />in height. <br /> <br />(b). Lateral support. Stone walls shall conform to <br />quirements for lateral support of other solid masonry walls <br />section 3 of this section. <br /> <br />the re- <br />in sub- <br /> <br />4. <br />(a). Thickness. <br />(1) The minimum <br />not less than that <br />of this section <br /> <br />thickness of walls of stone ashlar shall be <br />required for solid m.asonry walls in subsection 3 <br /> <br />. <br /> <br />4. <br /> <br />3. Alteration. No building shall <br />to exceed in area in any story the limits <br /> <br />Area modification. <br /> <br />be hereafter altered <br />fixed in this section <br /> <br />. <br /> <br />so as <br /> <br />2. Street. Under this section a street shall be deemed to in- <br />clude any avenue, boulevard, street, alley or lane, 20 feet or greater <br />in width, or any court, parking space or yard, with direct connection <br />to a street, and not less than 20 feet wide. Such court, parking space <br />or yard shall be the property of the owner of the building- and shall <br />not be enclosed or roofed over. <br /> <br />(e). For unprotected metal construction the area of one-story <br />buildings is not restricted; buildings exceeding one story shall not <br />e.."{ceed the area limits specified for noncombustible construction. <br /> <br />(c). For ordinary construction, and for noncombustible con- <br />struction, the area of one-story buildings shall not exceed 6,000 <br />square feet if fronting on one street, 7,500 square feet if fronting <br />on 2 streets, 9,000 square feet if fronting on 3 streets and 10,500 <br />square feet if fronting on 4 streets; provided that outside the fire <br />limits the area of one-story buildings of noncombustible construc- <br />tion shall not be restricted. The permitted areas for buildings ex- <br />ceeding one story shall not exceed 5,000, 6,000, 7,500, and 9,000 <br />square feet, when fronting on one, 2, 3 and 4 streets, respectively. <br /> <br />(d). For wood frame construction the area of buildings shall <br />not exceed 5,000 square feet. <br /> <br />(e). Other Requirements. <br />(1) Under-burned clay bricks shall not be used in any part of <br />a building or structure where exposed to the weather, nor in isolated <br />piers, nor in such part of a bearing wall above which the wall extends <br />more than 40 feet. <br />(2) Clay or shale brick laid in Type A or Type B mortar shall <br />be wet immediately before being laid, except that very hard or <br />vitrified brick need not be wetted. <br />(3) Horizontal and vertical joints in brick masonry shall be <br />filled with mortar. <br />(4) Except in dwellings interior bearing walls that are less than <br />12 inches in thickness and support wooden floor or roof joists, shall <br />be corbeled not less than 3 inches to receive such joists, unless ap- <br />proved metal joist hangers are used. <br /> <br />Stone Walls. <br /> <br />. <br /> <br />. <br /> <br />square feet if fronting on I streets, <br />fronting on three or more streets. <br /> <br />nor <br /> <br />10,000 <br /> <br />square <br /> <br />feet <br /> <br />if <br /> <br />e <br /> <br />e <br /> <br />(d). Bond. The facing and ~ing of solid masonry bearing <br />walls shall be bonded so that not less than 4 per cent of the wall sur- <br />face is composed of full length headers. The distance between adja- <br />cent full length headers shall not exceed 24 inches either vertically <br />or horizontally. In solid brick walls more than 12 inches thick the <br />inner joints of header courses shall be covered with another header <br />course which shall break joints with the course below. The facing <br />and backing of solid masonry non-bearing walls shall be bonded as <br />required above for bearing walls or shall be bonded with corrosion- <br />resistant metal ties spaced not farther apart than 16 inches vertically <br />and 24 inches horizontally. <br />