Laserfiche WebLink
<br />e <br /> <br />shall be deemed a story when used for purposes other than storage <br />or heating. <br /> <br />e <br /> <br />e <br /> <br />Height, as applied to a wall, means the vertical distance to the <br />top measured from the foundation wall, or from a girder or other <br />immediate support of such wall. ' <br /> <br />Hollow masonry unit means a masonry unit whose net cross- <br />sectional area in any plane parallel to the bearing surface is less <br />than 75 per cent of its gross cross-sectional area measured in the <br />same plane. <br /> <br />. <br /> <br />. <br /> <br />Lot means a portion or parcel of land considered as a unit, <br />devoted to a certain use or occupied by a building or a group <br />of buildings that are united by a common interest or use, and the <br />customary accessories and open spaces belonging to the same. <br /> <br />lot from another, or from <br /> <br />a <br /> <br />Masonry means brick, stone, plain concrete, hollow block, solid <br />block or other similar building units or materials, or combinations <br />of them, bonded together with mortar. Reinforced concrete is not <br />classed as masonry. <br /> <br />Multifamily house means a building occupied as the home or <br />residence of individuals, families or households living independently <br />of each other, of which three or more are doing cooking within <br />their apartments; including tenement house, apartment house, flat. <br /> <br />unit which has <br /> <br />adopted <br /> <br />Place of assembly means a room or space in which provision <br />is made for the seating of one hundred or more persons for religious, <br />recreational, educational, political, social or amusement purposes or <br />for the consumption of food or drink. Such room or space shall <br />include any occupied connecting room or space in the same story, <br />or in a story or stories above or below, where entrance is common <br />to the rooms or spaces. <br /> <br />fabricated <br /> <br />Prefabricated means composed of sections or panels <br />prior to erection on the building foundation <br /> <br />more <br /> <br />Solid masonry means masonry consisting of solid masonry units <br />laid contiguously with the joints between the units filled with mor- <br />tar, or consisting of plain concrete. <br /> <br />a masonry unit whose net cross- <br />parallel to the bearing surface is 75 <br />cross-sectional area measured in the <br /> <br />Solid masonry unit means <br />sectional area in every plane <br />per cent or more of its gross <br />same plane <br /> <br />Sprinkle red means equipped with an approved automatic sprink- <br />ler system properly maintained. <br /> <br />Street means any public thoroughfare, street, avenue, boulevard, <br />park, lane" terrace, concourse or space 20 feet or more in width which <br />has been dedicated or deeded to the public for public use. <br /> <br />S <br /> <br />Lot line nleans a line dividing one <br />street or other public space. <br /> <br />e <br /> <br />story from communicating to any other story; provided t.hat in <br />buildings of heavy timber construction there shall be no floor open- <br />ing that is not protected as prescribed in this section or in some <br />other approved manner. <br />(b). The provisions of this section shall apply to all shafts <br />used for ventilation, light, elevator, pipes, or other purpose, except <br />stairways, air ducts, incinerator chutes, flues, shafts in buildings of <br />wood frame construction, shafts in dwellings, and ramps in garages <br />exempted by section 37-6. <br /> <br />2. Shaft enclosures. The enclosing walls of shafts in residence <br />buildings of ordinary construction or noncombustible construction <br />or unprotected metal construction shall have a fire resistance rating <br />of not less than 1 hour. The enclosing walls of shafts in other <br />buildings shall be of noncombustible construction having a fire re- <br />sistance rating of not less than 2 hours. <br /> <br />3. Openings. Shaft enclosures shall" have no openings other <br />than those necessary for the purpose of the shaft; provided that in <br />elevator shafts there shall be at least one door in every 30 feet of <br />the height of such shaft. Such openings shall be protecteQ with <br />approved fire doors, approved fire shutters or approved fire windows. <br /> <br />Municipality means the governmental <br />this code under due legislative authority <br /> <br />. <br /> <br />two or <br /> <br />Shaft means a vertical opening or passage through <br />floors of a building or through floors and roof. <br /> <br />. <br /> <br />, <br /> <br />l <br />r <br /> <br />I <br /> <br />" <br />, <br />I <br /> <br />I <br />I <br />,I <br />I <br />l <br />I <br />, <br />:\ <br />I <br />I <br /> <br /> <br />" <br />i <br />I <br />I <br /> <br />I <br /> <br />'I <br />;[ <br />r <br />il <br />'I <br />,I <br />;1 <br />!: <br /> <br />. <br /> <br />4. Enclosure at top. <br />(a). Shaft enclosures extending through the roof which are to <br />be enclosed at the top, shall be provided with a skylight of at least <br />10 per cent of the area of the shaft in the top story and glazed with <br />plain glass ~-inch in thickness; provided that the skylight may be <br />replaced by a window of plain glass of equivalent area in the side <br />of the shaft if the sill of such window is not less than 2 feet above <br />the roof and the window does not face a lot line within 10 feet, or <br />may be replaced by approved means of ventilation. <br />(b). A shaft that does not extend through the roof shall have <br />the top enclosed with a form of construction having a fire resistance <br />rating equal to that of the walls of the shaft. <br /> <br />5. Enclosure at bottom. A shaft that does not extend to the <br />bottom of the building shall be enclosed at its lowest point with a <br />floor construction of the same type as that required for the lowest <br />floor to or through which it passes, but such shaft floor construction <br />shall have a fire resistance rating of not less than one hour. <br /> <br />6. Elevator machinery compartment. Compartments contain- <br />ing machinery for operating elevators shall be separated from the <br />elevator shafts by noncombustible construction having a fire re- <br />sistance rating of not less than 2 hours, with door openings equipped <br />with approved fire doors <br /> <br />elevators <br /> <br />more than 3 <br /> <br />Not <br /> <br />7. N umber of elevators in shaft. <br />shall be placed hereafter in one shaft. <br /> <br />ROOFING. <br /> <br />31 <br /> <br />SECTION <br /> <br />~ <br /> <br />. <br /> <br />(a). Every roof hereafter placed on a building shall be cov- <br />ered with an approved roofing of brick, concrete, tile, slate, metal, <br />asbestos, prepared asphalt asbestos-felt shingles, or of built-up <br />roofing finished with asphalt, slag or gravel, or other approved <br />material. <br /> <br />32 <br />