Laserfiche WebLink
<br /> .~.. <br /> ~ . <br />. . <br /> . <br /> 1 <br />.; . <br /> <br />(c). Clearances from combustible material to gas appliance <br />vent piping other than approved type B gas vents shall be in ac- <br />cordance with standard practice for safe installation and use as <br />required by section 36. <br />5. Flue mortar. All flue mortar for flues or vent pipes from <br />gas-burning appliances shall be acid resisting. <br />6. Draft hoods. Every flue connected appliance except an <br />incinerator, unless its construction serves the same purpose, shall be <br />equipped with an effective draft hood which either (1) has been <br />approved as part of the appliance or (2) complies with nationally <br />recognized standards for draft hoods. The draft hood shall be at- <br />tached to the flue collar of the appliance or as near to the appliance <br />as conditions permit and in a position for which it is designed with <br />reference to horizontal and vertical planes. The draft hood shall <br />be so located that the relief opening is not obstructed by any part <br />of the appliance or adjacent construction. <br /> <br />37 <br /> <br />4. Installation of gas vents other than type B. <br /> <br />(a). Gas appliance vent piping other than approved type B <br />gas vents shall not pass through any attic or concealed space <br />nor through any combustible floor, and shall not pass through any <br />combustible roof except as specified in subsection 2(c). Where <br />passing through combustible roofs in accordance with subsection <br />2(c) they shall be guarded at the point of passage as specified for <br />passage through combustible walls or partitions in paragraph (b) <br />below. Vent piping may extend through any existing chimney <br />whether the chimney is lined or not. <br /> <br />(b). Gas appliance vent piping other than approved type B <br />gas vents shall not pass through ,combustible walls or partitions <br />unless they are guarded at the point of passage (1) by metal venti- <br />lated thimbles not less than 6 inches larger in diameter than the <br />pipe, or (2) by metal thimbles not less than 4 inches larger in <br />diameter than the pipe with the annular space filled with mineral <br />wool or other approved noncombustible insulating material; or in <br />lieu of such protection all combustible material in the wall or par- <br />tition shall be cut away from the vent pipe a sufficient distance to <br />provide the clearance required from such vent pipe to combustible <br />material-any material used to close up such opening shall be non- <br />combustible. <br /> <br />(d). Type B gas vents shall <br />fuel burning appliances. <br /> <br />. <br /> <br />. <br /> <br />not <br /> <br />3. Installation of type B gas vents. <br />(a). Type B gas vents shall be made up with tight joints. <br />(b). Type B gas vents shall be installed with a clearance to <br />combustible material or construction whether plastered or unplas- <br />tered, of not less than one inch, provided that for vents of floor <br />furnaces such clearance shall be not less than 3 inches for a distance <br />of not less than 3 feet from the outlet of the draft hood, measured <br />along the center line of the vent piping. <br />(c). Suitable provision shall be made to prevent mechanical <br />injury to type B gas vents where they extend through walls, floors <br />or roofs. <br /> <br />be used with solid or <br /> <br />liquid <br /> <br />e <br /> <br />e <br /> <br />e <br /> <br />- <br /> <br />from combustible material and passage through wall or roof shall <br />comply with the provisions of subsection 4 of this section. <br />