Laserfiche WebLink
<br />",---.-. <br /> <br />e <br /> <br />t <br /> <br />'" <br />" <br /> <br /> <br />'''l!!~ <br /> <br />, <br /> <br />e <br /> <br />e <br /> <br />...6- <br /> <br />3. ALTER..lTION. No building shall be hereafter altered so as to <br /> <br />exceed in area in any story the limits fixed in this section. <br /> <br />4. AREA MODIFICATION. <br /> <br />(a) The limiting areas fixed in this section may be increased by <br />100 percent when the building is sprinklered" and by 200 percent when the <br />building is sprinklered and does not exceed one story nor an average of 25 <br />feet in height to the roof, or to a fire retardant ceiling through which <br />there shall be no openings except openings into shafts or duC?ts, the enclosing <br />walls of which are of construction equivalent to the ceiling. <br /> <br />(b) OUtside the fire limits the area of one-story buildings of <br /> <br />heavy timber construction, ordinary construction and wood frame construction <br />may be increased 33 1/3 per cent above the areas otherwise fixed in this <br /> <br />section, when aD. wood struc tural members" including columns, waD. and <br /> <br />partition studs and Sheathing, and floor and roof construction, are of <br />approved fire retardant treated lumber as defined in section 7. <br />(c) ,Outside the congested areas of the municipality" when a hazard- <br /> <br />ous condition is not created thereby, the area of a public building, a business <br /> <br />building or a storage bUilding, not over tHo stories high, may be increased in <br /> <br />excess of the areas fixed by this section" in the discretion of the governing <br />body of the municipality; provided that a building of combustible occupancy" <br />or involving considerable combustible material in its structural parts, shall <br /> <br />be sprinklcred, and also curtain 1x>ards or draft stops shaD. be installed as <br /> <br />required by the building official. <br /> <br />SECTION 17. LIGHT AND VENTILATI ON . <br />1. HABITABLE ROOMS. <br /> <br />(a) Every habitable room shall be provided with natural light and <br />ventilation by one or more windows, openin~ directly on a street or on a court <br />conforming to subsection 5 of this section. <br /> <br />(b) Such rooms shaD. be not less than 7 feet wide in any part, and. <br />I <br /> <br />shall contain not les~, than 70 square feet of gross floor area. SUch rooms <br /> <br />.... ...... .... <br /> <br />shall have a clear height of not less than 7 feet 6 inches for at least 60 <br /> <br />square feet of floor area. <br />2. OTHm ROOMS. Every room, other than a habitable room, used or <br /> <br />occupied by persons, except s"torage rooms with infrequent occupancy, shall be <br />provided with one or more lrd.ndOWS or ventilating skylights opening directly on <br />a street or on a court conforming to subsection 5 of this section; or such rooms <br />shaD. be trovided with an approved means of mechanical ventilatiOIl:. <br />