Laserfiche WebLink
<br />. - .., <br />" <br /> <br />e <br /> <br />. <br /> <br />e <br /> <br />.e,- <br /> <br />SECTICN 21. NONCOMBUSTIBLE CONS'lRUCTION. <br /> <br />1. DEFINITION. Noncombustible construction" as applied to buildings" <br /> <br />means that in 'Which all structural members" inaluding floors, roofs and their <br /> <br />supports, are of steel" iron" concrete, or of other noncombustible materials, <br />and in which the exterior wall.s are of noncombustible construction having a <br /> <br />fire resistance rating of not less than two hours. <br /> <br />2. WALLS. Exterior -enclosure walls shall provide a durable and <br />stable weather proof ex terior. <br /> <br />3. S'lRUCTURAL MEMBERS. All structural members shall be of st7el, <br />iron, reinforced concrete, or of other approved noncombustible materials. <br /> <br />4. PARTITIONS. <br /> <br />(a) If combustible material enters into the construction of par- <br />_ titions, they shall be built to have a fire resistance r ating of not less than <br />one hour; but this shaJJ. not prohibit the use .of wooden doors, door casings, <br />frames" jambs, and bucks" windOW' and transom frames and casings, unless the <br /> <br />p <br /> <br /> <br />- <br /> <br />partitions are required to b e fire partitions. <br />(b) Nothing in this section shall. prevent the erection of temporary <br /> <br />partitions of wood and glas~ or of metal and glass within the rooms or spaces <br />occupied by a single tenant. <br /> <br />( c) All pet"manent partitions shall rest on noncombustible ma terial3 . <br /> <br />SECTION 22. WOW FRAME COOS'1RUCTION. <br />. . <br /> <br />1. DEFDUTION. Wood frame cons~ruction, as applied to buildings" <br />means that in which wallis and interior construction arewholly or partly of <br /> <br />wood. <br /> <br />2. WALLS. <br /> <br />(a) Framing for exterior walls shall be constructed to develop a <br />strength and rigidity equivalent to wooden studding, not less than 2 by 4 inches, <br /> <br />nom:inal dimenSions, spaced 16 inches on centers with the larger dimension perpen- <br /> <br />dicular to the wall, and braced with sheathing or diagonal bracing at t he comers <br />to secure the necessary rigidity; except that in one-story buildin~s studs not over <br />10 feet in length may be spaced not to exceed 24 inches on centers. <br /> <br />(b) In buildings except private garages, an exterior wall which is <br />less than 3 feet distant from the lot line along an adjoining area 'Which:iis or may <br />.' be built upon shall be of noncombustible consl;ruotion having a fire resistance <br />.... ,J rating of not less than two hour,S; except that the material of the weather sur- <br />face mBj1 'be similar to that of other exterior walls of the building. <br />