<br />. <br /> <br />,r, <br />" , <br /> <br />" , <br /> <br />" <br /> <br />t~, <br /> <br /> <br />,,-... ./ <br /> <br />. <br /> <br />. <br /> <br />-27- <br /> <br />FJRESTOPPING. <br /> <br />(a.) Ex ter.iDr. wall.s of wood frame construction shall be prqzperly <br />firestopped at each fioor level, at the top story ceiling level, at the roof <br />level in the case of flat roofs, and at the :toot of roof rafters in the case <br /> <br />of sloping roofs. <br /> <br />(b) Joists shall be firestopped at the ends and over supports for <br />the full depth of the joists. <br />(c) Interior stud partitions shall be firestopped at the noor and <br /> <br />ceiling of each story by a 2-inch, nominal dimension" wood plate, the 1IVidth of <br />the stud, or the equivalent. <br />(d) When sliding doors are pocketed in par~ tions, such pockets <br /> <br />shall be completely firestopped at the top, bottom and ends. <br />(e) Firestopping shall b e of noncombustible material or of wood <br /> <br />not less than 2 inches in thicKness, nominal dimension. No firestopping shall <br /> <br />be covered or concealed until inspected 't:u the building official. <br /> <br />16. !RAFT STOPS IN ATTIC SPACES. Dl'aft stops shall be provided in <br /> <br />attic spaces as required by Section 20-10. <br /> <br />SECTION 23. UNPROTECTED MEl'AL CONS'lRUCTION. <br /> <br />Unprotected IlE!tal consl:iruction, as applied to buildings, means that <br />in which the structural supports are unprotected metal and in which floors and <br /> <br />roofs are of noncombustible construction, and the exterior 'V'Talls are of non- <br /> <br />combustibJ.e constt'uction having a fire resistance rating of less than 2 hours. <br /> <br />SECTION 24. WORKMANSHIP AND MATERI.AI5 . <br /> <br />All building material;; shall be of good quality. Worlananship in the <br /> <br />fabrication, preparation and installation of materials shall conform to generally <br /> <br />accepted good practice. <br /> <br />SECTIOl.J 25. DESIGN LOADS, STRESSES AND WIND PRESSURE. <br /> <br />Buildings or structures, including tanks" towers, end signs, hereafter <br /> <br />erected and all new construction 'in the alteration of heretofore erected buildings <br /> <br />or structures shall be disigned and constructed for live and dead loads and. wind <br />pressures in accordance 'With the National Building Code, 1949 Edition, recommended <br />by the National Board of Fire UnderwI.'iters, and with resulting stresses not in ex- <br />cess of those permitted by said code. <br /> <br />SECTION 26. FOUNDATIONS. <br /> <br />Except when erected upon hardpan or solid rock or upon walls or piers <br />on the water front, foundation walls or other permanent supports shall be carried <br />not less than one foot below frost line and shall rest on solid ground or on <br />leveled rock, or on piles <I' ranging timbers when solid earth or rock is not found; <br />