<br />t,-" 1oI" <br /> <br />e <br /> <br />t <br /> <br />, <br /> <br />, <br /> <br />'-I <br /> <br />. <br /> <br />-32- <br /> <br />(b) Lateral s'.1pport. stone walls shall conform to the requirements <br />for lateral support of o'~her solid masonry walls in subsection 3 of this section. <br />,(c) Bond. <br />(1) In ashlar masonry" bond stones uniformly distributed shall be <br />provided to the extent 0.1' not less than 10 percent of the area and having not <br />less than 4 inches of bond into the backing masonry. <br />(2) Rubble stc.ne masonry 24 inches or less in thickness shall have <br />bond stones with a maximum spacing of 3 feet vertically and horizontally" and <br />if the masonry is of greater thiclaless than 24 inches shall have one bond stone <br />for each 6 square feet of wall surface on both sides and no heBder stone shall <br />be less than 12 inches 10:J.g measured at right angles to the face of the masonry. <br />(d) Natural be is. All stones showing pronounced cleavage shall be <br />laid on their natural bed" except for cornices and other projecting members <br />w'hich shaJ.l have the grain or bedding planes verticaJ. and at right angles to <br />the face of the masonry. <br />5. VTALlS OF HOlJ..ON MASONRY UNITS. <br />(a) Thickness end height. <br />(1) The minimun. thiclaless of walls of hollow masonry units shall be <br />not less than that required for solid masonry waJ.ls in subseotion 3 of this sec- <br /> <br />tion. <br /> <br />(2) '\'falls of hollow masonry '\mits shall not exceed ~O feet in height. <br />(b) LateraJ. sup:?ort. V(alls of hollow masonry units shall be supported <br />at right angles to the wall face at invervals not exceeding 18 times the nominal <br />wall thiclaless. Such late]~al support shall conform to subsection 10 of this <br /> <br />section. <br /> <br />(c) Bond. <br />(1) Hollow masonry units shall have full mortar coverage of the face <br />shells in both the horizont.al and vertical joints-. <br />(2) Where tVlO or more hollow units are us ed to make up the thickness <br />of a wall" the inner and outer courses shall be bonded at vertical intervals" <br />not exceeding 3 feet, by lapping at least 4 inches over the unit below or by <br />lapping with units at least 50 per cent greater in thickness than the unit below <br />at vertical intervals not exceeding 17 inches. <br />(3) Brick facing or lining (vrhich does not include veneering when <br />used in hollow block wal1s 13hall be bonded to the backing in accordance with <br />paragraph (d) of subsection 3 of this section. <br />