Laserfiche WebLink
<br />, <br /> <br />I <br /> <br />-36- <br /> <br />~.. <br /> <br />(a) Fire walls <.lIld party walls of masonry shall be laid in Type A or <br /> <br />It <br /> <br />Type B mortar. <br />(b) Fire ?lalls end party walls shall be constructed of solid masonry <br /> <br />units, or of hollow masonrjl' units faced on each side wi.th brick, or of reinforced <br /> <br />concrete. <br /> <br />(c) Where structural members project into hollOW' masonry units the <br /> <br />ho11O'<I space shall be fille:! with noncombustible material the full thiclmess of the <br />'vrall and 4 inches or more a:>ove, bet\veen and belm" such members. <br /> <br />2. THICKHESS OF an.ID MASONRY WALLS EXCEPT PANEL 1'VALLS. <br /> <br />(a) For b'ls1ness buildings and storage buildings, fire walls and party <br />l'falls of solid masonry unitH shall be not less than 16 inches thick for the upper- <br />--', , most !io :reet and increase 4 inches in thielmess :ror each additional 3!i :reet or f'rac- <br />tv .~ion thereof measured dowmverd from the top of the wall; except that where the walls <br /> <br />are non-bearing, or where beams or girders are supported on the vvall by approved <br />Iletal hangers and do not enter the wall the minimum thiclmess may be 16 inches for <br /> <br />ihe uppermost 70 feet. <br />(b) For other buildings, fire walls and party walls of solid masonry <br />units shall be not less than 12 inches thick for the uppermost 35 feet and increase <br />4 inches in thickness for ea::h additional 35 feet or fraction thereof measured dmm- <br /> <br />'\Irard from the top of the wal:L. <br /> <br />3. TEICKN1SS OF BlUCK-FACED HOLLaV MASONRY VfALLS. Fire walis and party <br /> <br />, <br /> <br />walls of hollow masonry unitB faced on each side with at least 4 inches of brick <br />shall have a total thiclmess including the facing not less ~an 4 inches greater >,. <br />than specified in subsection 2 above f or so~id masonry walls. t <br /> <br />~ <br /> <br />-" <br /> <br />4. THICKNI::SS OF Rl!:mFORCED CONCRETE W'ALLS EXCEPT PANEL WALLS. <br /> <br />(a) For business 't:uildings and storage buildings, fire walls and party <br />wcLlls of reinforced concrete shall be not less than 11 inches thick for the uppermost <br />3~: feet and increase 2 inches in thiclmess for each successive 35 feet or fraction <br /> <br />tt..ereof measured downward from the top of the wall. <br />(b) For other buil:lings, fire walls and party walls of reinforced con- <br />crete shall be not less than 9 inches thick for the uppermost 35 feet and increase <br />2 inches in thiclmess for eac:1 successive 35 f'eet or fraction thereof measured <br /> <br />dO'l'IIlward from the top of the lVall. <br /> <br />'t <br /> <br />5. EXCEPTION TO THICKNESS REQUmEMENTS FCR PANEL \VALIS. 'Where fire vlallS <br /> <br />or party walls are constructec~ as panel walls in a framew'ork of colu.ms and girders <br />protected as required for fireproof construction and no panel has a height between <br />supports greater than 12 feet, they may be of solid masonry not less than 12 inches <br />thi.ck or of re:i.nforced concrete not less than 8 inches thick. <br />