Laserfiche WebLink
<br />.. . " . <br />:.' ., ,". <br />.. ... : . <br />"ii' <br /> <br />e <br /> <br />e <br /> <br />., <br />. , <br /> <br />NON FIRE RELATED ISSUES <br /> <br />. 1) Electrical not to code <br />A) Outlet spacing <br />B) Number of circuits <br />C) Need smoke detectors in each bedroom and at top of stairs <br />2) Replacement wood is alkaline copper. The nails used appear to be <br />electro plated and if so, must be replaced with hot dipped <br />galvanized nails. <br />3) Weather seal in various locations needs to be replaced. This <br />requires removal of siding. <br />4) Beam at kitchen not to code. <br />5) No windstorm clips or bracing in building. <br />6) Hot water heater not accessible as per code <br />7) Provide workspace in front of air handler as per code. <br /> <br />BASED ON 5-29-04 HCAD V ALUA nON: HOUSE AND GARAGE IS 52,220.00. <br />PROPOSED REPAIRS WILL EXCEED V ALUA nON BY MORE THAN 100%. <br />. In order to rebuild this home, the following state laws and city codes must be complied <br />with and the house brought to 100 % code compliance. <br />· Texas Wind Storm <br />· Texas Energy Code <br />· Texas Residential Construction Commission <br />· 2003 International Residential Code <br />· '2002 National Electrical Code <br />· City of La Porte Ordinances <br /> <br />All work shall be performed by licensed and insured contractors. <br /> <br />s:\CPShare\INSPECnON DI'v1SION\Inspections\F1RE DA..\{AGE W ALK-THRU\ST A.."l SHERWooD.doc <br />