Laserfiche WebLink
<br />A = Adequate <br />I. SlRUC'I'URAL <br /> <br />A. Foundation <br />1. Slab <br />2. Pier & Beam <br />a Footings <br />b. Sills <br />c. Joists <br /> <br />B. Walls <br />1. Exterior <br />2. Interior <br />C. Means of Egress <br />1. Doors <br />a Interior <br />b. Exterior <br />Porches, Steps, <br />Stairs <br />3. Wmdows <br />D. Roof <br />1. Rafters <br />2. Deck, Shingles <br /> <br />E. Ceilings <br />1. Joists <br />2. Ceiling <br /> <br />F. Floors <br /> <br />G. Other <br /> <br />II. MEHCANICAL SYSTEMS <br /> <br />A. Electrical <br />1. Service En1I3nce <br />& Panel <br /> <br />2. Wiring <br />3. Lights, Switches <br />4. Outlets <br />5. Other <br />B. Plumbing <br />1. Fixtures <br />a Sink <br />b. Lavatories <br />c. WaterlClosets <br />d Shower <br />e WaterHeater <br />2. Water Piping <br />3. Drain, Waste <br />&VCDt <br />4. Sewer <br />S. Gas System <br />Heating & AlC <br />1. Heating <br /> <br />2. Air Conditioning <br /> <br />D = Deficient <br /> <br />BUILDING EVALUATION CHECKLIST <br /> <br />A-- <br />~ <br />N/A <br />N/A <br /> <br />IL-- <br />IL-- <br /> <br />IL-- <br />IL-- <br /> <br />IL-- <br />IL-- <br /> <br />N/A <br />IL-- <br /> <br />UNK <br />IL-- <br /> <br />UNK <br />IL-- <br /> <br />IL-- <br />UNK <br />UNK <br />UNK <br />IL-- <br /> <br />llliK...- <br />~ <br />UNK <br />UNK <br />IL-- <br />A-- <br />IL-- <br />UNK <br />~ <br /> <br />IL-- <br /> <br />llliK...- <br /> <br />ill. PROPERTY CONDmONS <br /> <br />1. Accessory Structures N/ A <br />2. Condition of Grounds IL-- <br />3. Other <br /> <br />N/ A = Not Applicable <br />COMMENT / EXPLANATION <br /> <br />NO VISffiLE DEFICIENCIES <br /> <br />VISffiLE HOLES IN WALL <br />DRYWALL DAMAGE VISffiLE THRU WINDOW UPSTAIRS <br /> <br />MAJORITY OF APTS WERE BOARDED UP. UNABLE TO INSP <br />UPSTAIRS (1) BROKEN OPEN <br /> <br />UNSAFE. RUSTED AND/OR DAMAGED <br />UP-WINDOWS BUSTED OUT: DOWN-WINDOWS BOARDED UP <br /> <br />POOR ROOF CONDmON: MAJOR WATER DAMAGE <br />TO nm ING UPSTAIRS <br /> <br />MAJORITY UNKNOWN <br />UPSTAIRS-FALLEN DRYWALL OBSERVED THRU WINDOWS <br />DOWNT AIRS UNITS BOARDED UP <br /> <br />MAJORITY OF APTS BOARDED UP. UNABLE TO INSP <br /> <br />SOFFIT. FACIA ROT <br /> <br />PANEL COVER MISSING. BREAKERS MISSING. LOOSE <br />WIRING: WIRING NOT TO CODE. <br />UNABLE TO INSPECT <br />UNABLE TO INSPECT <br />UNABLE TO INSPECT <br />OU1LET COVERS BROKEN & MISSING, UPSTAIR-WEST APT <br /> <br />MAJORITY OF APTS BOARDED UP. UNABLE TO INSP <br />MAJORITY OF APTS BOARDED UP. UNABLE TO INSP <br />MAJORITY OF APTS BOARDED UP. UNABLE TO INSP <br />MAJORITY OF APTS BOARDED UP. UNABLE TO INSP <br />(1) UNIT INSPECTED. WATER HEATER MISSING <br />NO VISffiLE DEFICIENCIES <br /> <br />(1) OPEN UNIT - BROKEN DRAIN PIPE UNDER SINK <br /> <br />(1) OPEN UNIT UPSTAIRS: WATER DAMAGE FROM ROOF <br />NOT VISffiLE <br /> <br />WEEDS <br /> <br />Comments: INTERIOR INSPECTION MADE ON OPEN UNIT UPSTAIRS CWESTI APT ON 3-16-04. <br />SECURING OF BUILDING DONE BY CITY OF LA PORTE <br /> <br />S:'CPSbarellNsPECTION DMSJON\AI.L OTIlER STUFFICode Enforcemeat\DaDg Bui1dingsID B INSP FORMGARFIELD BLOO 3.d0<:02-2004 Rev. <br />