Laserfiche WebLink
<br />City of La Porte <br /> <br />DANGEROUS BUILDING INSPECTION FORM <br /> <br />DAlE: 6-21-06 <br /> <br />STREET ADDRESS: 513 S VIRGINIA <br />HCAD OWNER: CITY OF LA PORTE <br /> <br />- <br />DEED OWNER: PAUL SCHAIDER &. ELAINE SCHAlDER -1608 ROSCOE A \/E- LA PORTE. TX 77571 <br />OTHER: 2005 TAX RESALE: PAUL J. SCHAIDER - 1608 ROSCOE - LA PORTE. TX 77571 <br />LEGAL:BLK240. LTS 8. 9&. S7'OFLOT7 &N 4.58'OFLOT 10 &.ADJ. STRIP. SAN JACINTO HOMES <br /> <br />OCCUPANCY 1:YPE: RESIDENCE ZONING: R-1 <br />NON-CONFORMING ISSUES: N/A <br />F AClLITIES A V AlLABLE: WATER.; YES SEWER: YES <br /> ELECTRICAL: YES GAS: YES <br />NO.OF DWELLlNG UNITS: (1) <br />VACANT: YES OCCUPIED: <br /> <br />AS REQumED IN THE ClTY'S CODE OF ORDINANCE, CHAPTER 82; ARTICLE vm, THE BOARD OF <br />INSPECTION MADE AN INSPECTION OF THE AFOREMENTIONED PROPERTY, AND DETERMINED THE <br />BUIlDING LOCATED THEREON, IN THEIR OPINION, IS IN FACT A DANGEROUS BUlLDING, FOR THE <br />FOLLOWING REASONS: <br /> <br />Sec. 82-473. Declaration of Public Nuisance and Hazard. <br /> <br />A. Dangerous or Substandard Buildings or Structures. <br />A building or structure shaD be cODSidered dangerous or substandard "believer it is <br />determined by the Board, that any or all of the following is applicable: <br /> <br />~l. A building that is vacant, and is not up to current building code standards. These vacant buildings <br />can be either open to trespass or boarded up; <br /> <br />L-2. Whenever any portion thereofbas been damaged by fire. earthquake, wind, flood, or by any other <br />cause to such an extent that the structmal strength or stability thereof is materially less than it was before such <br />catastrophe and is less than the minirmun requirements of the building code for new buildings of similar structure, <br />puzpose or location; <br /> <br />L-3. Whenever any portion or member or appurtenance thereof is likely to fail, or to become detached <br />or dislodged, or to collapse and thereby injure persons or damage property; <br /> <br />L- 4. Whenever the building or structure, or any portion thereo~ because of (a) dilapidation, <br />deterioration, or decay; (b) faulty constroction; (c) the removal, movement or instability of any portion of the <br />ground necessary for the purpose of supporting the building; (d) the deterioration, decay, or inadequacy of its <br />foundation, or (e) any other cause, is likely to partially or completely collapse; <br /> <br />L-.S. Whenever, for any reason, the building or structure, or any portion thereot: is manifestly unsafe for <br />the purpose of which it is being used; <br />