<br />Dangerous Buildings Inspection Form Bldg 1 <br /> <br />Page 2 <br /> <br />_6. Whenever the building or structure has been so damaged by fire, wind, earthquake, or flood, or has <br />become so dilapidated or deteriorated as to become (a) a public nuisance, (b) a harbor for vagrants, or as to (c) <br />enable persons to resort thereto for the purpose of committing unlawful acts; <br /> <br />L-7. Whenever a building or structure, used or intended to be used for dwelling purposes, because of <br />inadequate maintenance, dilapidation, decay, damage, faulty construction or arrangement, inadequate light, air, or <br />sanitation facilities, or otherwise, is determined by the Board to be unsanitary, unfit for human habitation or in <br />such a condition that is likely to cause sickness or disease; <br /> <br />L-S. Whenever any building or structure, because of obsolescence, dilapidated condition, deterioration, <br />damage, inadequate exits, lack of sufficient fire-resistive construction, fuulty electric wiring, gas connections, or <br />heating apparatus or other cause, is determined by the Board to be a fire hazard; <br /> <br />B. Dangerous or substandard electrical, plumbing, or mechanical installations. <br />A building or structure shall be considered dangerous or substandard whenever it is determined by <br />the Board, that any or all of the foUowing is applicable: <br /> <br />L-L Whenever any protective or safety device specified in The Electrical Code and of this title is not <br />provided or is inoperative, defective, dilapidated, or deteriorated so as to threaten to fuil or function as originally <br />intended; <br /> <br />L-z. Whenever any installation or any portion thereof because of (a) dilapidation, deterioration, or <br />decay; (b) faulty construction; (c) obsolescence; (d) inadequate maintenance, which in relation to existing use <br />constitutes a hazard to life, health, property or safety; <br /> <br />3. Whenever any installation or any portion thereof which is damaged by fire, wind, earthquake, <br />flood or any other cause so as to constitute a potential hazard to life, health, property or safety; <br /> <br />L- 4. Whenever any installation or any portion thereof was constructed, installed, altered or mainUlined <br />in violation of the building code and/or fire code so as to constitute a potential hazard to life, health, property or <br />safety. <br /> <br />FINDINGS AND CONCLUSIONS OF TIIE BOARD OF INSPECTION: <br /> <br />OPTION #1: <br /> <br />(REF AIRABLE - RESIDENTIAL) <br /> <br />IN ACCORDANCE WITH TIIE CITY'S DANGEROUS BUILDING REGULATIONS AND TIIE 2003 INTERNATIONAL <br />RESIDENTIAL CODE. AS ADOP'IED. AMENDED AND ENACI'ED BY CITY. ORDINANCE #04-2700 AND #96-2079- <br />B. USING TIIE REGULATIONS AND CODE AS ITS GUIDE. IT IS TIIE OPINION OF TIIE DANGEROUS BUILDING <br />INSPECTION BOARD TIiAT TIllS BUILDING IS IN FACT DANGEROUS. BUT STILL REPAIRABLE. ALL <br />REOUIRED REPAIRS OR ALTERATIONS SHALL BE DONE IN ACCORDANCE WITH ALL APPLICABLE CITY OF <br />LA PORTE CODES AND ORDINANCES. IF TIIE REPAIR OR ALTERATION ORDER IS NOT COMPLIED WITII <br />WITHIN TIIE TIMETABLE SET OUT IN ARTICLE vm. SECTION 82-478. IT IS mEN TIIE OPINION OF TInS <br />BOARD TIiAT TInS BUILDING BE DEMOLISHED. <br /> <br />x Cid. W~ (/5--/9-l1h <br />BUILDING OFFICIAL'S OFFICE DATE <br /> <br />~~~~ <br /> <br />L~/fi~ f <br />S-p3/d~ <br /> <br />DATE <br /> <br />x tJ /J1!1-,o:>t <br />FIRE CHIEFS OFFICE <br />