My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
R-2009-01 adopt amendments to Public Improvement Criteria Manual (PICM), relating to drainage criteria and improvement standards
LaPorte
>
Legislative records
>
Resolutions - GR1000-05 Ordinances & Resolutions
>
2000's
>
2009
>
R-2009-01 adopt amendments to Public Improvement Criteria Manual (PICM), relating to drainage criteria and improvement standards
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2016 3:50:30 PM
Creation date
3/2/2009 4:29:55 PM
Metadata
Fields
Template:
Legislative Records
Legislative Type
Resolution
Date
2/23/2009
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />requirements of ASTM C 76, "Reinforced Concrete Culvert, Storm Dmin. and Sewer Pipe," <br />current revision. Reinforced concrete pipe shall be Cla.'ls III or stronger. The design engineer <br />shall provide for increased pipe strength when conditions of the proposed installation exceed the <br />allowable load for Class III pipe. All concrete pipe constructed in water-bearing soil or forty-two <br />inches (42") in diameter or larger, sbalI have rubber gasket joints meeting the requirements of <br />ANSI/ASTM C 443, "Joints for Circular Concrete Sewer and Culvert pipe. Using Rubber <br />Gaskets", current revision. Concrete pipe with diameter of less than forty-two inches (42") may <br />be installed using pipe with tongue and groove t)'pe joint and Ram-uelt, or approved equal, as a <br />joint filler. When specifically approved by tbe City Engineer, reinforced concrete arch and <br />elliptical pipe conforming to ASTM C506 and ASTM C507, respectively, current revision. may be <br />installed in lieu of circular pipe. Reinforced concrete box culverts shall meet the minimum <br />requirements of ASTM C789, "Precast Reinforced Concrete Box Sections for Culverts, Storm <br />Drains, and Sewers", current revision. Pipe joints for arch and elliptical pipe and box culverts <br />shall be sealed using Ram-nek or approved equal. <br /> <br />5.8.2 Storm sewer outfalls into open channels shall be constructed using corrugated steel pipe. <br />Corrugated steel pipe sball be manufactured in conformance with the requirements of <br />AASHTO Designation M-36-82, current revision. Pipe material shall be Aluminized Steel Type <br />2, meeting the requirements of AASHTO Designation M-27-791, current revision, or Pre-coated <br />Galvanized Steel, AASHTO M-246, 10 mil coating on both sides. All pipe shall have a full <br />double coating, Type A, in accordance with AASHTO Designation M-190, current revision. Pipe <br />joints and fittings shall meet the minimum requirements of these specifications and shall have an <br />O-ring gasket seal meeting the requirements of AASHTO C-361, current revision. (See City of La <br />Porte Construction Details). <br /> <br />5.8.3 Stonn sewer outfalls shall have a slope protection to prevent erosion. Slope protection may be <br />constructed of slope paving or rip rap. Slope paving shall be four-inch (4") five (5) sack concrete <br />with six-inch by six-inch (6" x 6") welded wire mesh (W14 x W14) or three eighths inch (3/8") <br />steel rebar on twenty-four-inch (24") centers, each way. Rip rap shall be a minimum of six-inch <br />(6") broken concrete rubble with no exposed steel or well-roUllded stone and shall be a minimum <br />of eighteen inches (18") thick. Slope protection te:\turing shall be required where public access <br />likely. Refer to the Construction Details for minimum dimensions. <br /> <br />5.9 ADDITIONAL REQIJIREMENTS <br /> <br />5.9.1 Minimum depth of storm sewer (measured to the top of pipe) shall be twenty-four (24") below the <br />top of curb or finished grade, whichever is lower. Minimum size storm sewer for main and <br />inlet lead shall be twenty-four inches (24"). <br /> <br />5.9.2 Storm sewers shall be bedded using cement stabilized sand (see specification in Section 4.2.3) as <br />shown in the City of La Porte Construction Details. <br /> <br />5.9.3 Pipe requirements. <br /> <br />A. Reinforced concrete pipe installed at a depth greater than thirty feet (30') shall be designed by the <br />engineer for the specific installation and approved by the City Engineer, Reinforced concrete pipe <br />shall be designed in accordance with the American Concrete Pipe Association, "Concrete Pipe <br />Design Manual", Ma.~mum cover on the pipe shall be measured from the top of pipe to the <br />ultimate fmished grade or natural gr01md, whichever is greater. <br /> <br />B. Corrugated steel pipe shall have a minimum thickness as follows: <br /> <br />PIPE SIZE <br />(Inches) Corrugations (Inches) <br />242-2/3" X 112" <br />)0- 482-2/3" X 1/21 <br /> <br />MINIMUM THICKNESS <br /> <br />0.052 <br />0.064 <br /> <br />Stonnwaler Criteria Page 9 of 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.