My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
R-2004-03 adopt portion of “PICM" relating to water system design criteria and improvements
LaPorte
>
Legislative records
>
Resolutions - GR1000-05 Ordinances & Resolutions
>
2000's
>
2004
>
R-2004-03 adopt portion of “PICM" relating to water system design criteria and improvements
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2016 3:50:27 PM
Creation date
10/26/2006 3:00:55 PM
Metadata
Fields
Template:
Legislative Records
Legislative Type
Resolution
Date
1/26/2004
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />e <br /> <br />e <br /> <br />L. Provide a source of fresb water at each end or at multiple points ofa subdivision <br />or development. Provide ways to create circulation and place valves and fire <br />hydrants to allow simple flushing of lines. <br />2. Where stubs are provided for future extensions, isolate the stubs with a valve <br />and no service connections will be allowed beyond the valve before the line is <br />extended. .Place one full joint of pipe between the valve and the plug. <br /> <br />J. New Water Lines Constructed Near Sanitary Sewers and Force Mains and Manholes <br /> <br />L. New Water Lines Parallel to Sanitary Sewer and Force Mains: Locate water <br />lines a minimum of 10 feet horizontally, outside wall to outside wall, when <br />parallel to sanitary sewers and force mains. Use the following procedure when <br />site conditions prohibit achieving 10 feet of separation. When the 10 foot <br />separation cannot be achieved the approval of the Director of Planning or his <br />designated appointee must be obtained: <br /> <br />a. When a new water line is to parallel an existing sanitary sewer force <br />main or gravity sewer and the 10 foot minimum separation cannot be <br />achieved, the existing sanitary sewer shall be replaced with lined <br />ductile iron pipe, SDR-26 with pressure gaskets, or PVC C-900 150 psi <br />pipe or better and equipped with pressure type joints. <br />b. The water lines and sanitary sewer shall be separated by a minimum <br />vertical distance of 2 feet and at least 4 feet horizontally (per 30 T AC <br />290.44) measured between the nearest outside walls of the pipes, where <br />the water line shall always be located above the sewer. <br /> <br />2. <br /> <br />New Water Lines Crossing New and Existing Sanitary Sewers and Force Mains <br /> <br />a. No protection is required if the sanitary sewer is 10 feet below the <br />water line. <br />b. Use the protective requirements given in Table 3.3 and 3.4 for sanitary <br />sewer crossings not 10 feet below the water line. <br /> <br />3. Sanitary Sewer Manholes: Provide a minimum 10 foot horizontal clearance from <br />outside wall of existing or proposed manholes, make manholes and connecting <br />sewers watertight and test for leakage. If a 10 foot clearance cannot be obtained, <br />the water line may be located closer to the manhole when prior approval has <br />been obtained from the Planning Director or his designated appointee by using <br />one ofthe procedures below; however, in no case shall the clearance be less than <br />4 feet. <br /> <br />a. <br /> <br />The City of .La Porte may require the water line may be encased in a <br />casing when site conditions dictate or when the water line is within 5 <br />feet of a manhole. The carrier pipe shall be a minimum of I joint of <br />150 psi pressure class pipe at least 18 feet long and two nominal sizes <br />larger than the water conveyance pipe. <br />The water line may be augured, bore &jacked, or microtunneled past <br />the manhole with at least one 18 foot section of 150 psi pressure pipe <br />installed centered about tbe existing sanitary manhole with pressure <br />grouting of the annular space using a bentonite/clay mixture or other <br />commercial grouts. <br /> <br />b. <br /> <br />January 2004 <br /> <br />Water System Design Criteria Page 11 of 13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.