My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
O-2020-3803 Adopting the 2018 International Code editions for Building and 2020 National Electrical Code with local amendments
LaPorte
>
Legislative Records
>
Ordinances - GR1000-05 Ordinances & Resolutions
>
2020's
>
2020
>
O-2020-3803 Adopting the 2018 International Code editions for Building and 2020 National Electrical Code with local amendments
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2020 11:48:13 AM
Creation date
9/29/2020 11:48:04 AM
Metadata
Fields
Template:
Legislative Records
Legislative Type
Ordinance
Legislative No.
O-2020-3803
Date
9/28/2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8. Portable-fuel-cell appliances that are not connected to a fixed piping system and are not <br /> interconnected to a power grid. <br /> Plumbing: <br /> 1. The stopping of leaks in drains, water, soil, waste or vent pipe; provided, however, that if any <br /> concealed trap, drainpipe, water, soil, waste or vent pipe becomes defective and it becomes <br /> necessary to remove and replace the same with new material, such work shall be considered as <br /> new work and a permit shall be obtained and inspection made as provided in this code. <br /> 2. The clearing of stoppages or the repairing of leaks in pipes, valves or fixtures, and the removal <br /> and reinstallation of water closets provided such repairs do not involve or require the <br /> replacement or rearrangement of valves, pipes or fixtures. <br /> Table R301.2(1) Climatic and Geographic Design Criteria. Establishment of criteria in accordance <br /> with table shown. <br /> GROUND _ WIND DESIGN SEISMIC SUBJECT TO DAMAGE FROM WINTER ICE BARRIER FLOOD AIR MEAN <br /> Special Frost <br /> SNOW Speed Topographic Wind Windborne DESIGN Weathering line Termite DESIGN UNDERLAYMENT HAZARD FREEZING ANNUAL <br /> debris <br /> LOAD (mph) effects region zone CATAGORY Depth TEMP REQUIRED INDEX TEMP <br /> VERY See FIRM 1500 <br /> Wind 69°Zone <br /> 0 150 NO NO 3 A NEGLIGIBLE 12" HEAVY 32°F NO Maps and or less F <br /> Missile D. Ordinances <br /> MANUAL 1 DESIGN CRITERIA <br /> Elevation Latitude Winter Summer Altitude Indoor design Design Heating temperature <br /> heating cooling correction factor temperature temperature cooling difference <br /> 23ft to 9ft-Check Site 29°40' 32°F 94°F 1 70°F 75°F 38°F <br /> Wind Wind <br /> Cooling velocity velocity Coincident Daily Winter Summer <br /> temperature difference heating cooling wet bulb range humidity humidity <br /> 19°F 15 mph 7.5 mph 78 M 60% 85% <br /> *Windborne Debris Protection: <br /> Skylights are missile level C <br /> Missile levels are for elevations less than or equal to 30 ft <br /> Section R301.2.1.2 Protection of Openings. Exterior glazing, in new or building additions, located in <br /> windborne debris regions shall have glazed openings protected from windborne debris. Glazed <br /> opening protection for windborne debris shall meet the requirements of the Large Missile Test of <br /> ASTM E 1996 and ASTM E 1886 referenced therein. Garage door glazed opening protection for <br /> windborne debris shall meet the requirements of an approved impact-resisting standard or <br /> ANSI/DASMA 115. <br /> Code Deletions. <br /> The following sections of the 2018 International Residential Code are deleted. <br /> Subsection R309.5 Fire Sprinklers <br /> Section R313 Automatic Fire Sprinkler Systems <br /> Subsection R905.7 Wood Shingles <br /> Subsection R905.8 Wood Shakes <br />
The URL can be used to link to this page
Your browser does not support the video tag.