Laserfiche WebLink
2.2 DETAILED SCOPE -OF -SERVICES (Continued) <br />Preliminary Asbestos Containing Material (ACM) Evaluation - Asbestos inspection is an additional <br />service not provided in a basic Phase I (see Asbestos Section 6.2.1). No efforts are typically made to <br />identify the presence of the most obvious and common ACM. In the event of a survey the potential for <br />the presence of friable ACM are evaluated based on the age of the improvements, dates of renovation <br />and other relevant information. The USEPA Guidance Document: Managing Asbestos in Place: A <br />Building Owner's Guide to Operations and Maintenance Programs for Asbestos -Containing Materials <br />(the Green Book) and 40CFR Part 763; Asbestos -Containing Materials in Schools were used as a guide in <br />identifying suspect materials. Materials listed in the Green Book, which were installed prior to 1989, are <br />suspected of containing asbestos. However, it should be noted that asbestos may still be utilized in <br />some non -friable products, such as sheet vinyl flooring, vinyl floor tiles, floor tile mastic, asbestos - <br />cement board, and roofing materials, as these materials may still be manufactured and installed in the <br />United States. The level of the preliminary evaluation performed was not designed to comply with the <br />survey requirements of the Asbestos Hazard Emergency Response Act (AHERA), 40 Code of Federal <br />Regulations (CFR) Part 763, National Emission Standard for Hazardous Air Pollutants (NESHAP) 40 CFR <br />61, Occupational Safety and Health Administration (OSHA) 29 CFR Part 1926.1101, or other local, state <br />of federal regulations, but has been conducted per accepted industry practices to satisfy the scope of <br />work of the rating agencies and/or lenders. <br />Samples collected, if any, will be analyzed for the presence of asbestos by a National Voluntary Lab <br />Accreditation Program (NVLAP) accredited laboratory using polarized light microscopy and dispersion <br />staining. Any testing results obtained are for the personal use of the Client only. No sampling of <br />undamaged materials is included in the scope of work. If damaged suspect materials are observed, <br />limited samples may be collected. <br />Documentation and Sources - Photographs representative of Geo-Tech's observations are included in <br />the Appendix. In addition to visual observations, Geo-Tech relied on sources and contacted individuals <br />who are listed in the Appendix. If and when applicable, additional forms and checklists required by the <br />Client are also included in the appendices. <br />The Phase I Environmental Site Assessment does not include: <br />• Soil, groundwater, or building material sampling; <br />• Chain of title or environmental lien search; <br />• Any non -scope considerations, unless specifically contracted for, to include but not limited to <br />the following: <br />*Asbestos Containing Building Materials *Health and safety <br />*Radon *Ecological Resources <br />*Lead -based Paint *Endangered Species <br />*Lead in drinking water *Indoor air quality/mold <br />*Wetlands *Biological Agents <br />*Regulatory Compliance *Vapor Intrusion <br />*Cultural and Historic Resources *Controlled Substances <br />*Industrial Hygiene *Earthquake and fault zones <br />Commercial Properly Ge Tech Environmental Inc. <br />Broadway & East A St., La Porte, Tx 77571 Project Number:MM3 <br />