<br /> <br />Wiring and Protection <br /> <br />Author's Comment: The two exceptions permitting receptacles that were not readily accessible and <br />single or duplex receptacles for two appliances within a dedicated space for each appliance to not <br />have GFCI protection for personnel in garages and unfinished basements were deleted. The <br />substantiation in the proposal and the discussion during the Panel deliberation indicated that the present <br />generation of GFCI devices do not have the problems of nuisance tripping that plagued earlier devices. <br /> <br />REFRIGERATOR <br />OR FREEZER <br /> <br />1{ <br /> <br />RECEPTACLE FOR <br />APPLIANCES OCCUPYING <br />DEDICATED SPACE <br />· 210.8(A)(2) <br />(2005 NEC) NOT REQUIRED <br />TO BE GFCI-PROTECTED <br />> (2008 NEC) REQUIRED TO <br />BE GFCI-PROTECTED <br /> <br />:.~ <br /> <br /> <br /> <br />~ RECEPTACLE IS NOT <br />READILY ACCESSIBLE. <br />· 210.8(A)(2) <br />(2005 NEC) NOT REQUIRED TO BE GFCI-PROTECTED <br />(2008 NEe) REQUIRED TO BE GFCI-PROTECTED <br /> <br /> <br />ATTACHED OR DETACHED <br />GARAGE WITH POWER <br /> <br />WORK <br />BENCH <br /> <br /> <br />GFCI-PROTECTED <br />RECEPTACLE <br />· 210.52(G) <br />· 210.8(A)(2) <br /> <br /> <br />CORD-AND-PLUG <br />CONNECTED <br />· 210.8(A)(5) <br />(2005 NEC) NOT REQUIRED TO BE <br />GFCI-PROTECTED <br />(2008 NEe) REQUIRED TO BE <br />GFCI-PROTECTED <br /> <br />DWELLING UNITS <br />210.8(A)(2); (A)(5) <br /> <br />Purpose of Change: The exceptions permitting receptacles that were not readily accessible and <br />single or duplex receptacles for two appliances within a dedicated space for each appliance to not <br />have GFCI-protection for personnel in garages and unfinished basements were deleted. <br /> <br />2-11 <br />