Laserfiche WebLink
.' <br />~. Y3} •.r .: ~ •S: <br />~L~A.....: y,4. r.~._, <br />o--•• <br />.'L•~:^A.. ..y~~rt •i:~+~.it~~1'• )~~•~1 :•~® •~i''j~:l:/J.,i}~. i1 <br />.. ,,+~ .'p i.1J).1ftY./;.rJ1•: .',•i!.}. \ :-`."~ ..,•,S?~'.}• ::1 . _.~?`: J-=`tJSr %iY~~['.1 <br />.•~. r :•^t. ice. I. '.y• ~k. 7 <br /> <br />'.. <br />.. ~A <br />(b) Where special processes of a hazardous nature or storage hazards aze to <br />be constructed or introduced onto the premises of any occupancy other than private <br />dwellings, they s:ial.t protected in accordance ~,rith adopted st~ ~ •rds herein as <br />applicable. \\ <br />NOTE: Building owners and occupants should consult with appropriate state and <br />federal agencies for special requirements of those agencies for worker safety. <br />(c) All required water mains and fire Yrydrants located in La Porte shall be <br />installed as follows: <br />(1) Residential Areas-Hydrants shall be placed so that no structure is <br />over 500' from hydrant and installed on a 6" or larger approved water <br />main. Distance for hydrant placements shall be measured at curb line. <br />(2) Commercial and Industrial Areas- Hydrants shall_be placed so that no <br />• .f <br />. A water main mzterials, placements and installation Hereof and <br />fire hydrant installation, together with water main sizing, shall be <br />approved by the La Porte Engineering Depaztrrent. <br />(4) All fire hydrant placements shall be approved by the La Porte Fire <br />Depaztment . <br />(5) If a required water main and/or hydrant is not a~:ailable, the builder <br />shall install said main or hydrant tinder prevailing rules and regulations <br />of the City of La Porte. <br />(6) The requirements of Subsection (c) of this section shall not be <br />retroactive prior to the effective date of this code revision. <br />(d) All buildings required by the Fire Code or Building Code to have a <br />sprinkler system for fire protection shall have a wet sprinkler system. The design <br />and installation of said system shall be as per N.F.P.A. 13 specifications. <br />A'OTE: In addition to the aforementioned requirements: 1,2,3,4,5 as follows <br />shall also be required. <br />(1) ASSEyBLY OCCUPANCIES <br />(a) All Class A assembly occupancies shall be totally sprinklered. <br />(b) When Class B assembly occupancies are located in a building above <br />the level of exit discharge, the building shall be totally sorinklered. <br />(c) When Class C assembly occupancies are located in a building two (2) <br />stories or more above the level of exit discharge, the building shall be <br />totally sprinklered. • <br />(2) BUSINESS OCCUPANCIES <br />Business occupancies three (3) stories or more in height shall be totally <br />sprinklered. <br />(3) RESIDENTIAL OCCUPANCIES <br />(a) Hotels, motels, dormitories and lodging or rooming houses three (3) <br />stories or more in height with exterior means of egress shall be totally <br />sprinklered. <br />(a-1) Hotels, motels, dormitories or lodging or rooming houses two (2) <br />stories or more in height with interior means of egress shall be totally <br />sprinklered. <br />(b) Apaztsnent buildings three (3) stories or mere in height with exterior <br />means of egress shall be totally sprinklered. <br />(b-1) Apartment buildings two (2) stories or more in height with interior <br />means of egress shall be totally sprinklered. <br />(4) All buildings totally sprinklered shall have an electrically supervised <br />water flow alarm installed as per N.F.P.A. 72 C specifications to tray <br />nit an alarm to the Fire Department dispatch office. <br />(5) All sprinkler systcnts with twenty (20) or more sprinkler heads shall have <br />a Fire Department connection. <br />EKC•EPrtoN <br />In buildings with sprinkler systems that have four (4) sprinkler heads or less, <br />all applicable N.F.P.A. 13 specifications shall be satisfied exc•pt: <br />(1) The water supply may be furnished from the domest.;c water supply line <br />if said water supply is adequate to meet the sprinkler system requirements. <br />(2) The sprinkler system tap on said water supply line shall be made before <br />rate water m.:ter. <br />(?) ThP sprinkler syst{3n water supply line shall not have any intervening <br />valves er cer*tectinns,•excep+: fc>r an emergency sprinkler system shut-off <br />valve located outtiae the pr^tected area it an accessible location. <br />r~~ -, EXHIBIT D <br />