Laserfiche WebLink
Cost Estimate for Geotechnical Engineering Services 1 rerrac ®n <br /> Drainage Ditch Improvements — Battleground Estates ® La Porte, Texas <br /> July 5, 2011 ® Terracon Document No. P91110112 <br /> Page 2 <br /> B. SCOPE OF SERVICES <br /> A brief summary of the services to be provided by Terracon is presented in the following <br /> paragraphs. <br /> Field Program. The field program is planned to consist of drilling six (6) test borings to depths of <br /> 20 feet below existing grade along the proposed drainage ditch improvements, and two test borings <br /> to depths of 10 feet below existing grade (top of paving) for the roadside ditches along <br /> Bois D'Arc Drive. The total drilling footage is planned to be 140 feet. <br /> Soil samples will generally be collected utilizing either open -tube samplers or Standard Penetration <br /> Test. Once the samples have been collected and classified in the field, they will be properly <br /> prepared and placed in appropriate sample containers for transport to our laboratory. We can locate <br /> the borings by measuring distances from existing streets and /or site features shown on the provided <br /> drawings, without the use of survey equipment. Boring depths will be measured from existing grade. <br /> The boring locations will be backfilled with soil cuttings and patched with asphaltic concrete (where <br /> needed). <br /> The drilling services for this project will be performed by a drilling subcontractor or Terracon's in- <br /> house drillers. We plan to use all- terrain vehicle (ATV)- mounted drilling equipment to access the <br /> boring locations. This scope of services assumes that the site can be accessed during normal <br /> business hours and does not include services associated with site clearing, location of on -site <br /> underground utilities, or the use of special equipment for unusually soft or wet surface conditions. If <br /> such conditions are known to exist on the site, Terracon should be notified so that we may adjust <br /> our scope of services and estimated fees, if necessary. <br /> Terracon will notify DIG TESS, a free utility locating service, to help locate public utilities within the <br /> vicinity of the site. If underground utilities are known to exist within the site, Terracon should be <br /> notified so that we may review utility plans and help avoid the existing lines. Terracon cannot be <br /> responsible for damage to unmarked and /or unlocated utilities for which we are unaware or that are <br /> improperly located. <br /> Laboratory Testing. The sample classifications will be reviewed and a laboratory testing program <br /> will be assigned which will be specific to the project requirements and the subsurface conditions <br /> observed. The testing program could include, but may not be limited to, moisture contents, unit dry <br /> weights, Atterberg limits, compressive strength tests and grain -size analyses. In addition, we plan to <br /> include crumb tests, pinhole dispersion tests, and consolidated undrained triaxial tests in <br /> accordance with HCFCD requirements. <br /> Reliable 0 Responsive ® Convenient ® Innovative <br />