10-13-04 Special Called Meeting of the La Porte Fire Review Board Minutes
LaPorte
>
City Secretary
>
Minutes
>
Fire Code Review Committee
>
2000's
>
2004
>
10-13-04 Special Called Meeting of the La Porte Fire Review Board Minutes
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/20/2017 5:12:14 PM
Creation date
3/21/2025 2:31:39 PM
Metadata
Fields
Template:
City Meetings
Meeting Body
Fire Code Review Committee
Meeting Doc Type
Minutes
Date
10/13/2004
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />'Fire Marshal Report <br /> <br />October 4, 2004 <br /> <br />Appeal Request #04-001 <br /> <br />Requested by: <br /> <br />Melissa L. Centanni, A.I.A. Vice President (Architect for United Methodist Church) <br /> <br />Requested for: <br /> <br />Appeal to Fire Marshal plan review requiring sprinkler system installation per subsection <br />amendment 603.15.9 of the City of La Porte ordinances. <br /> <br />Location: <br /> <br />9601 F ainnont <br /> <br />Proiect Description: The City of La Porte received a drawing for the property at 9601 Fairmont that is an <br />addition to a pre-existing worship assembly structure. <br /> <br />Per the notes on the drawings submitted: <br /> <br />"This project involves construction of a one story family life building (11,010 S.F. First <br />Floor Only) 7;270 square feet consist of a concrete tilt wall building with a concrete slab <br />on grade foundation and steel bar joist roof framing. The remaining 3,740 square feet <br />consist of a wood stud frame building with brick veneer, composition shingle roof, and a <br />prefabricated wood roof trusses. The new building and the existing building are <br />separated by a four-hour concrete masonry unit wall except where the 7 1/4 "thick <br />concrete tilt wall serves as part of the four hour separation this fire wall will be built 18" <br />above the existing building gable and the new building roofs." <br /> <br />Analvsis: <br /> <br />Ordinance amendment 603.15.9 states: In addition to any other fire and/or building code <br />requirements, the following occupancies shall be totally equipped with a sprinkler <br />system. Section 1. (A) All Class A assembly occupancies. <br /> <br />The adopted Life Safety Code 1997 ed. A-8-1.4 states: "Assembly occupancy <br />requirements should be based on a room-by-room basis, a floor-by-floor basis, and a total <br />building basis. The requirements for each room should be based on the occupant load of <br />that room and the requirements for each floor should be based on the occupant load of <br />that floor, but the requirements for the assembly building overall should be based on the <br />total occupant load. Therefore, it is quite feasible to have several assembly occupancies <br />with occupant loads of 300 or less grouped together in a single building and that building <br />would be an assembly occupancy with an occupant load of over 1000." <br /> <br />Note: Assembly occupancies with 300 or greater load requires a sprinkler system - if the <br />occupant load was to go over 1000 the type of Construction would be reviewed. <br /> <br />This structure is a Type A-2 Occupancy as per Standard Building Code 1994ed. <br /> <br />United Methodist Church <br />Fire Review Request <br />