07-21-20 Building Codes Appeals Board Meeting
LaPorte
>
City Secretary
>
Agenda packets 2010 to current
>
Building Codes Appeals Board
>
Building Codes Appeals Board
>
2020
>
07-21-20 Building Codes Appeals Board Meeting
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/13/2024 8:47:50 AM
Creation date
4/3/2025 2:57:52 PM
Metadata
Fields
Template:
City Meetings
Meeting Body
Building Codes Appeals Board
Meeting Doc Type
Agenda Packet
Date
7/21/2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
304,2 — Sloped Roof — Change Summary: Where equipment or appliances that require service <br />are installed on a roof having a slope of 4 units vertical in 12 units horizontal (33 percent slope) <br />or more, a level platform of not less than 30: inches (7162 mm) by 30 inches (762 mm) shall be <br />provided at the service side of the equipment or appliance. <br />310.1.1 —Condensate Pumps —Change Summary. Where approved by the Authority Having <br />Jurisdiction, condensate pumps shall be installed in accordance with the manufacturer's <br />installiation instructionis. Pump discharge shall rise vertically to a point where it is possible to <br />connect to a gravity condensate drain and discharged to an approved disposal point. Each, <br />condensing unit shall be provided with a separate sump and interlocked with the equipment to <br />prevent the equipment from operating during a failure. Separate pumps shall be permitted to <br />connect to a single gravity indirect waste where equipped with check valves and approved by <br />the Authority Having Jurisdiction. <br />510.5,6 — Duct Leakage, Test — Change Summary: Prior to the use of or concealment of a grease <br />duct system, a leakage test shall be performed to determine that welded joint and seams are <br />liquid tight. The leakage -test shall consist of a light test, water pressure test, or an approved <br />equivalent test. The permit holder shall' be responsible for providing the necessary equipment <br />and for performing the test. Such test shall be conducted in accordance with ASHRAE.154. <br />1202.0 — Protection of Potable Water Supply <br />o 1202.1 — Prohibited Sources <br />o 1202.2 — Chemical Injection <br />o 12023 — Compatibility <br />1204.O — Identification of Potable and Nonpotabie Water System <br />o 1204.1 — General — In buildings where potable water and nonpotable water systems are <br />installed, each system shall be clearly identified in accordance with Section 1204.2 <br />through Section 1204.5. <br />o 1204.2 —Color and Information <br />o 12043 — Potable Water <br />o 1204.4 — Nonpotable Water <br />o 1204.5 — Location of Piping identification <br />o 1204.6 —Flaw Direction, <br />Please Note: The Code Changes Listed Above iDo Not Include All Changes to the Code <br />