Laserfiche WebLink
ZONING <br />FIGURE 10-2 <br />CURB AND DRIVEWAY CRITERIA, RESIDENTIAL DISTRICTS <br />(R-1, R-2, R-3, MH) <br />Driveway <br />Requirements <br />Drive width <br />12' to 25' <br />Curb return radius <br />2' to 5' <br />Distance from intersection <br />25'min,* <br />Spacing, between driveway <br />10' min. <br />Distance from side lot line <br />Xmin. <br />Intersecting angle <br />90 <br />Approach grade <br />5% max, <br />For concrete drives only: <br />a. Material <br />Min. 4" thickness <br />w/ 6x6-6/6 WW.M. <br />b. Expansion joint <br />At property line <br />c. Curb (if applicable) <br />Curb disappearing at <br />property line <br />Obstruction clearance <br />Min. 3'from poles,, <br />hydrants, etc. <br />§ 106-835 <br />This distance shall be measured from the intersection of property lines common with street <br />right-of-way lines. <br />FIGURE 10-3 <br />CURB AND DRIVEWAY CRITERIA <br />COMMERCIAL AND INDUSTRIAL DISTRICTS <br />Driveway Criteria <br />Requirements <br />Commercial <br />Industrial <br />Drive width <br />20' to 25' <br />30' to 40' <br />Curb return radius <br />10' to 15' <br />10' to 15' <br />Distance from intersection <br />40'* <br />40'min.* <br />Spacing between driveways <br />40'min. <br />40'min. <br />Number of accesses <br />1J80'; 2/150' <br />1/80'; 2/150' <br />% of property frontage <br />40% <br />40% <br />Intersecting angle <br />90 <br />90 <br />Approach grade <br />5% max. <br />5% max. <br />Expansion joint <br />At prop. line <br />At prop. line <br />