My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
04-25-11 Regular Meeting of the La Porte City Council
LaPorte
>
.Agendas
>
City Council
>
2010's
>
2011
>
04-25-11 Regular Meeting of the La Porte City Council
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2015 5:10:39 PM
Creation date
7/25/2025 3:09:03 PM
Metadata
Fields
Template:
La Porte TX
Document Type
Agenda PACKETS
Date
4/25/2011
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
205
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
• <br /> Company Representative, any person considered to <br /> be disposed or disorderly, or for any other <br /> reason unsatisfactorily complying with the <br /> requirements of this specification, and such <br /> person shall not: again be employed on the work <br /> without the consent of the Company. <br /> 3.9.6 The Grantee /Contractor shall not permit or <br /> suffer the introduction or the use of <br /> intoxicating liquor or narcotic drugs upon any <br /> of the grounds occupied or controlled by the <br /> Company. <br /> 3.9.7 No structure of any type shall be constructed. on <br /> Company Property unless a final set of detailed <br /> drawings have been reviewed and approved by the <br /> TransrnissiouOperations Department. Structures <br /> include but are not limited to signs, fences, <br /> paving, lighting, drainage facilities, etc. Ali <br /> structures of any type must be properly <br /> • <br /> grounded. <br /> 3.9.8 No temporary fuel tanks.shall be stored on <br /> Company Property unless prior written approval <br /> has been granted. Prior to approval, a specific <br /> location Will be determined by the Company <br /> Representative and the Grantee /Contractor. Fuel <br /> tanks within Company Property must be adequately <br /> grounded and beamed for spill protection. <br /> 0 3.9.9 No equipment or material shall be permitted on <br /> Company Property at a height greater than 15 <br /> feet above natural ground elevation, unless <br /> approved by the Company Representative, Cranes, <br /> lifts, etc. shall be blocked so that operators <br /> . may not bring the boom to a greater height_ <br /> 3.9.10 Trenching - and excavation will not be permitted <br /> Within twenty (20) feet of any structure <br /> foundation or other facilities measured at <br /> ground level unless approved by the Company <br /> Representative. <br /> 3.9.11 Excavation shall comply with CFR 1926.651. The <br /> installation of sheet piling, cribbing or other <br /> protective measures beyond the scope of CFR <br /> 1926.651 Will be required if stipulated by the <br /> Company Representative. <br /> 1110/A WO SPEC. M. I 007 231 79 I Sheet 8 of 19 <br />
The URL can be used to link to this page
Your browser does not support the video tag.