Laserfiche WebLink
<br />.-' <br /> <br />.~.. ..... <br /> <br />e <br /> <br />e <br /> <br />2 <br /> <br />5. Another method to prevent outside damage would be to install 611 thick <br />steel. reinforced concrete slab in the drainage ditch. This slab would <br />cover the width of the drainage ditch extending two feet on both side of <br />pipeline and approximately one foot above the pipeline. On crossing <br />where ditches are not needed and concrete curb mayor may not inplace <br />then the concrete slab will be installed in 10 feet section to the right of <br />way line. <br /> <br />6. Added wall thickness of pipe may give some addition to safety but <br />normally does not prevent accidents. <br /> <br />If approved the Gulf Oil Corporation 611 pipe replacement across City of <br />LaPorte streets and roads will be bored and pulled using concrete coated line <br />pipe cathodically protected with magnesium anodes without casing. <br /> <br />R/W DEPARTMENl" <br />FEBRUARY, 1984 <br />D. B. CURRIE <br />