Laserfiche WebLink
<br />A = Adequate <br /> <br />I. <br /> <br />, E. <br /> <br />. <br /> <br />e <br /> <br />BUILDING EVALUATION CHECKLIST <br /> <br />D= Deficient <br /> <br />STRUCTURAL <br />A. Foundation <br />1. Slab <br />2. Pier & Beam <br />a. Footings <br />b. Sills <br />c. Joists <br />Walls <br />1. Exterior <br />2. Interior <br />Means of Egress <br />1. Doors <br />a. Interior <br />b. Exterior <br />2. porchs, steps, <br />stairs <br />3. Windows <br />Roof <br />1. Rafters <br />2. Deck, Shingles <br />Ceilings <br />1. Joists <br />2. Ceiling <br />Floors <br />Other <br /> <br />B. <br /> <br />C. <br /> <br />D. <br /> <br />F. <br />G. <br /> <br />N/A = Not Applicable <br /> <br />COMMENT/EXPLANATION <br /> <br />D <br /> <br />Garage Slab Cracked <br /> <br />D <br />D <br />D <br /> <br />Severe Settling & Shifting <br />Deteriorated & Collapsing <br />Deteriorated <br /> <br />D <br />N/A <br /> <br />Deteriorated <br />* <br /> <br />N/A <br />D <br /> <br />* <br />, Deteriorated <br /> <br />D <br />D <br /> <br />Unleve1 <br />Deteriorated <br /> <br />D <br />D <br /> <br />Deteriorated <br />..-ShingleR Deteriorated, Too Many Layers <br /> <br />N/A <br />'N/A <br />N/A <br />N/A <br /> <br />* <br />* <br />'.Jc <br /> <br />II. MECHANICAL SYSTEMS <br /> A. Electrical <br /> 1. Service Entrance <br /> & Panel D DeteriorRted, Not IIp to Code <br /> 2 . Wiring N/A * <br /> 3 . Lights, Switches liLA.- * <br /> 4. Outlets N/A * <br /> 5. Other N/A <br /> B. Plumbing <br /> 1''- Fixtures *1 <br /> a. Sink D <br /> b. Lavatories D *1 <br /> c. Water Closets JL *1 <br /> d. Tub/Shower D *] <br /> e . Water Heater JilA. * <br /> 2 . Water Piping D *1 <br /> 3 . Drain, Waste *1 <br /> & Vent D <br /> 4. Sewer/Septic Tank JL *1 <br /> 5. Gas System D Meter Removed by Entex <br /> C. Heating &Air Conditioning <br /> 1. Heating N/A * <br /> 2. Air Conditioning N/A . .. <br /> <br />III. PROPERTY CONDITIONS <br />1. Accessory structures N/A <br />2. Condition of Grounds -n- <br />3. Other N/A <br /> <br />Maintained by City <br /> <br />COMMEtiTS :*Garage is Open & Unsecured. House is Otherwise Locked & <br /> <br />Inaccessible. Report Based on Exterior Inspection Only, Except for Garage. <br /> <br /> <br />*1 Settling of Foundation System ~s Severe Enough to Cause Serio~s Problems <br /> <br />With Plumbing. This Will Prevent Noted Fixtures From Functioning Properly. <br /> <br />01-'92 Rev. aldangbldg.frm/dangerous building <br />