2004-11-08 Regular Meeting, Public Hearing and Workshop Meeting
LaPorte
>
.Minutes
>
City Council
>
2000's
>
2004
>
2004-11-08 Regular Meeting, Public Hearing and Workshop Meeting
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2016 12:07:20 PM
Creation date
7/31/2025 11:02:37 AM
Metadata
Fields
Template:
City Meetings
Meeting Body
City Council
Meeting Doc Type
Minutes
Date
11/8/2004
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
360
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />_~ ...'1 <br /> <br />3.4 SECTION 15501 FIRE PROTECTION SYSTEM, delete this section in its entirety. <br /> <br />3.5 SECTION 02482 DREDGING, change to SECTION 15760 ELECTRIC UNIT HEATERS. <br /> <br />3.6 SECTION 15810 DUC1WORK <br />A. Delete Paragraphs 2.02.0, 2.02.C and 2.02.F. <br />8. Delete Paragraphs 2.03.A, 2.03.8 and 2.03.C. <br />C. Paragraph 2.07.A, add "and Division 10 Section" to the first sentence. <br />D. Delete Paragraphs 2.07.8, 2.07.C, and 2.07.0. <br />E. Delete Articles 2.08 and 2.09. <br />F. Delete Articles 3.08,3.09 and 3.10. <br /> <br />3.7 SECTION 15820 FANS, delete Article 2.06. <br /> <br />3.8 SECTION 16010 ELECTRICAL GENERAL PROVISIONS <br />A. Subparagraph 3.04.8.1, add "4" hours. <br />8. Subparagraph 3.04.8.2. add "2 hours on each of 2 days." <br /> <br />3.9 SECTION 16025 OPERATING AND MAINTENANCE MANUALS, change heading to <br />Division 16. <br /> <br />3.10 SECTION 16040 SHOP DRAWINGS, COORDINATION DRAWINGS & PRODUCT DATA, <br />A. Delete subparagraphs 1.01.8.1,1.01.8.8,1.01.8.12,1.01.8.15, 1.018.17, 1.01.8.18, <br />1.01.8.19and 1.01.8.20. <br /> <br />PART FOUR - MODIFICATIONS TO DRAWINGS: <br /> <br />4.1 SHEET C2.0 DRAINAGE PLAN, from existing inlet "C" to new inlet "8" change discharge <br />drain line RCP to 24 inches with restrictor pipe per Drawing ADD2.2. <br /> <br />4.2 SHEET A1.02 SITE DETAILS <br />A. DETAILS 01,02,03 and 04,3X3 Galv. Angle framing is existing at Ownerfumished <br />drying rack. <br />8. FENCE SECTION 07 <br />1. Wall panel note, add: prefinished to match building wall panels. <br />2. Galv. Steel channel note, add: 6"X2 1/2X2.41Ibs per If., roll to curve. <br /> <br />4.3 SHEET A2.00 ROOM FINISH SCHEDULE, add general requirement: Provide 6 inch <br />insulation batts above all suspended ceilings. <br /> <br />4.4 SHEET A2.01 REFLECTED CEILING PLAN <br />A. Change drywall partitions indicated to extend and seal to deck to masonry at Rooms <br />113,114 and 115. <br />8. Ceiling Fans indicated shall be equivalent to Casablanca Fan Company, Stealth Model <br />3245T, XLP-2000 motor, 53 inch blade span, brush nickel finish with dark cherry finish <br />blades , pendant extension to 8 ft. above floor. Provide wiring and connection to <br />switched circuit in accordance with Division 16 electrical requirements. Provide support <br />hangers from roof structural members. <br /> <br />Proj. No. 328-1 00900-2 <br />