O-2013-3481 adopting new Building Codes/ICC, amending NEC
LaPorte
>
Legislative Records
>
Ordinances - GR1000-05 Ordinances & Resolutions
>
2010's
>
2013
>
O-2013-3481 adopting new Building Codes/ICC, amending NEC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/5/2019 3:23:53 PM
Creation date
5/16/2013 2:28:53 PM
Metadata
Fields
Template:
Legislative Records
Legislative Type
Ordinance
Date
5/13/2013
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ordinance # 2013 - 3 `i � 1 Page 2 <br />(d) Fees shall be in accordance with Appendix A of the City's Code of Ordinances. <br />See. 82-32. Residential Code Amendments. <br />The residential building code adopted in Section 82-31 of this Article shall be amended to read <br />as follows: <br />Section R105.2 Work Exempt from Permit. Plumbing: The stopping of leaks in drains, water, <br />soil, waste or vent pipe; provided, however, that if any concealed trap, drainpipe, water, soil, <br />waste or vent pipe becomes defective and it becomes necessary to remove and replace the same <br />with new material, such work shall be considered as new work and a permit shall be obtained <br />and inspection made as provided in this code. The clearing of stoppages or the repairing of leaks <br />in pipes, valves or fixtures, and the removal and reinstallation of water closets. <br />Table R301.2(1) Climatic and Geographic Design Criteria. Establishment of criteria in <br />accordance with table shown. <br />Section R301.2.1.2 Protection of Openings. Exterior glazing, in new or building additions, <br />located in windbonre debris regions shall be protected from windbome debris. Glazed opening <br />protection for windbortte debris shall meet the requirements of the Large Missile Test of ASTM <br />E 1996 and ASTM E 1886 referenced therein. The applicable wind zones for establishing <br />missile types in ASTM E 1996 are shown on Figure R301.2(4)C. Garage door glazed opening <br />protection for windborne debris shall meet the requirements of an approved impact -resisting <br />standard or ANSVDASMA 115. <br />Part VIII, Electrical Chapters 34-43 (E3401 thru E4304.5 are deleted in their entirety. <br />See. 82-33. Building Code Amendments. <br />The building code adopted in Section 82-31 of this Article shall be amended to read as follows: <br />Section 101.1 Title. These regulations shall be known as the Building Cade of the City of La <br />Porte, hereinafter referred to as "this code". <br />Section 419 Live/Work Units. Deletion of entire section (Sections 419.1 thru 419.9) <br />WIND DESIGN <br />SEISMIC <br />SUBJECT TO DAMAGE <br />Frost <br />FROM <br />WINTE <br />R <br />GROUND <br />DESIGN <br />Llne <br />DESIGN <br />ICE BARRIER <br />FLOOD <br />AIR <br />MEAN <br />SNOW <br />Speed - <br />Topographic <br />CATEGORY <br />Weathenreg Depth <br />Termite <br />TEMP <br />UNDERLAVMEN <br />HAZARDS <br />FREEZING <br />ANNUAL <br />LOAD <br />(mph) <br />effects <br />r <br />1.1.1.T <br />REQUIRED ro^ <br />V <br />INDEX r <br />TEMP y <br />4-9-87 <br />11-5-96 <br />1500 or <br />0 <br />120 <br />No <br />A <br />N <br />12' <br />VH <br />32' <br />No <br />6.18-07 <br />less <br />67' <br />Section R301.2.1.2 Protection of Openings. Exterior glazing, in new or building additions, <br />located in windbonre debris regions shall be protected from windbome debris. Glazed opening <br />protection for windbortte debris shall meet the requirements of the Large Missile Test of ASTM <br />E 1996 and ASTM E 1886 referenced therein. The applicable wind zones for establishing <br />missile types in ASTM E 1996 are shown on Figure R301.2(4)C. Garage door glazed opening <br />protection for windborne debris shall meet the requirements of an approved impact -resisting <br />standard or ANSVDASMA 115. <br />Part VIII, Electrical Chapters 34-43 (E3401 thru E4304.5 are deleted in their entirety. <br />See. 82-33. Building Code Amendments. <br />The building code adopted in Section 82-31 of this Article shall be amended to read as follows: <br />Section 101.1 Title. These regulations shall be known as the Building Cade of the City of La <br />Porte, hereinafter referred to as "this code". <br />Section 419 Live/Work Units. Deletion of entire section (Sections 419.1 thru 419.9) <br />