Laserfiche WebLink
<br />e . <br /> <br />~-.,/~' ...1- F,,~.\If'-:I'" <br />L-... I' _ " <br /> <br />October 20, 1987 <br /> <br />Monsanto Chemical Company <br />P.O. Box 711 <br />Alvin, Texas 77512 <br /> <br />Attn: Mr. Butch Middlebrook <br /> <br />Subject: Hydrostatic Testing of lOR C02 Pipeline rroa <br />Texas City to LaPorte <br />Galveston and Harris Counties, Texas <br />(by u.s. Leak Detection, Inc.) <br />Test Date: October 15, 1987 <br /> <br />Dear Hr. Middlebrook: <br /> <br />This letter certifies that the hydrostatic testing performed on <br />the subject C02 pipeline by U.s. Leak Detection, Inc. met the <br />requirements of Title 49, erR (Dept. of Transportation), Part <br />192, -Transportation of Natural and Other Gas by Pipeline: <br />Minimum Fideral Safety Standards-, Subpart J, -Test <br />Requirements-. ~he pipeline vas tested for eight (I) hours, at <br />a minImum pressure of 1100 psig, successfully coapletlng the <br />mechanical strength test requirements of the above code. <br /> <br />The calculations performed on this test sectIon to correct for <br />temperature and pressure-related volume changes ID the pIpeline <br />are attached for your InformatIon only. WIthout true ground <br />(pIpe) temperatures, these calculations are not to be considered <br />fully accurate. Hovever, for the assumed constant ground <br />temperature of 7. deg. F., It does appear th~t tbe section Is <br />free of leaks. <br /> <br />Very truly yours, <br /> <br />~~.~ <br /> <br /> <br />WIlliam H. Olson, P... <br />attachments <br />