Loading...
HomeMy WebLinkAboutSENS RD BUSINESS PARKCONSTRUCTION PLANS FOR PROPOSED"SENS ROAD BUSINESS PARK"UTILITY AND PAVING IMPROVEMENTS(INSIDE HARRIS COUNTY, INSIDE CITY OF LA PORTE CITY LIMITS)JOB NO.: 2016-504 DATE: JULY 2016DESCRIPTIONSHEET COVER SHEETGENERAL NOTESSENS ROAD BUSINESS PARK SURVEY CONTROL PLANSENS ROAD BUSINESS PARK DRAINAGE AREA MAPSTORM SEWER CALCULATIONSOVERALL SITE PLAN AND SHEET LAYOUTSENS PARK ROAD PLAN AND PROFILE STA 0+00 TO STA 4+50SENS PARK ROAD PLAN AND PROFILE STA 4+50 TO STA 9+00SENS PARK ROAD PLAN AND PROFILE STA 9+00 TO STA 12+50SENS PARK ROAD PLAN AND PROFILE STA 12+50 TO STA 17+00SENS PARK ROAD PLAN AND PROFILE STA 17+00 TO STA 20+31.52DRAINAGE EASEMENT PLAN AND PROFILE STA 0+00 TO STA 5+00DRAINAGE EASEMENT PLAN AND PROFILE STA 5+00 TO STA 9+50DRAINAGE EASEMENT PLAN AND PROFILE STA 9+50 TO STA 12+5036-INCH STORM SEWER PLAN AND PROFILE STA 0+00 TO 4+50STORM WATER POLLUTION PREVENTION PLANSTORM WATER POLLUTION PREVENTION DETAILSWATER LINE DETAILSSANITARY SEWER DETAILSSANITARY SEWER DETAILSTRENCH SAFETY DETAILSSIDEWALK DETAILSCITY OF LA PORTE SWPPP DETAILSPRECAST STORM SEWER DETAILSPRECAST CONCRETE JUNCTION BOX MANHOLE DETAILSSTORM SEWER CONSTRUCTION DETAILSCONCRETE PAVEMENT DETAILS SHEET 1 OF 2CONCRETE PAVEMENT DETAILS SHEET 2 OF 2PAVEMENT MARKING DETAILS SHEET 1 OF 2PAVEMENT MARKING DETAILS SHEET 2 OF 2TRAFFIC CONTROL PLAN - NORTH DRIVEWAYTRAFFIC CONTROL PLAN - SOUTH DRIVEWAY1234567891011121314151617181920212223242526272829303132@ SENS PARK DRIVE A N. 23RD STREET, LA PORTE, TX 77571STOP - CALL BEFORE YOU DIG!!SENS ROAD BUSINESS PARKWORK IN HC R.O.W. 48 HOUR NOTICE:PROJECT ADDRESS:PROJECT LOCATION:THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-799908/24/16Construction of Facilities and/or Paving Work within Public Right-of-Way: 2GENERALCONSTRUCTIONNOTESRLREP2016-504Aug 24,2016 - 9:01am08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCUN.T.S.GENERAL CONSTRUCTION NOTESGENERAL NOTES:WHEN A COMMERCIAL DRIVEWAY OR CURB & GUTTER IS CONSTRUCTED,RECONSTRUCTED, REPAIRED OR REGRADED ON COUNTY RIGHT OF WAYUSE THE FOLLOWING: 3SENS ROADBUSINESS PARKSURVEY CONTROLPLANRLREP2016-504Aug 24,2016 - 4:15pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCU1"=80' 4SENS BUSINESSPARK DRAINAGEAREA MAPRLREP2016-504Aug 24,2016 - 4:17pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCU1"=80'DRAINAGE LEGEND 5STORM WATERPOLLUTIONPREVENTION PLANRLREP2016-504Aug 24,2016 - 12:21pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCU1"=30' OHE OHE OHE OHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHE OHE OHEOHE OHEOHE OHEOHE OHE OHE OHEOHEOHEOHE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE PIPELINE X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXXXX X X XXX X XXXXXXXXXXX XXXX XXXXXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXX X X XXXXX X XXXXXX X XXXXXX X XXXXXXX XXXXXXX XXXXXXXXXXXXXXXXXXXXX X XX XX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXo o o o o o o o o o o o o o o o o o o o o o o o o o oooXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X>>>oooooXXXXXX X XXXXX XXXXXXX X XXXXXX XXXXXX XOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHE 6OVERALL SITE PLANAND SHEET LAYOUTRLREP2016-504Aug 24,2016 - 4:23pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCU1"=80' 7SENS PARK ROADALIGNMENT APLAN & PROFILESTA 0+00 TO STA 4+50RLREP2016-504Aug 24,2016 - 1:12pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCU1"=20'SENS PARK ROAD (60' R.O.W.)0+501+001+500+002+002+503+003+504+005+001"=2'100-YEAR FLOOD PLAIN INFORMATION:According to FEMA map no. 48201C0945-L dated effective June 18, 2007 of the Federal EmergencyManagement Agency's flood insurance rate map for Harris County and incorporated areas, the subjecttract is mostly situated within Shaded Zone "X" defined as areas determined to be outside the 0.2%annual chance flood and partially within Zone "AE" defined as areas determined to be within the 1%annual chance flood (100-year flood) also known as the base flood with base flood elevations determined.This flood statement does not imply that the property or structures thereon will be free from flooding orflood damage. On rare occasions floods can and will occur and flood heights may be increased byman-made or natural causes.100-year Base Flood Elevation = 20.98'BENCHMARK INFORMATION:1.RM 060040: Floodplain reference number 060040 is described as a brass disk set in concrete with anelevation of 24.67 feet above mean sea level, N.A.V.D. 1988, 2001 adjustment.PERMIT NOTES:2.OWNER OR OWNER'S AGENT to obtain all permits required by the "Regulations of the City of LaPorte, Texas" prior to starting construction.3.OWNER OR OWNER'S AGENT to obtain all notifications required by Harris County, Texas prior tostarting construction of utilities and/or culverts within Harris County and Harris County Flood ControlDistrict Rights-of-Way.4.The contractor(s) shall notify Harris County Public Infrastructure Department - Architecture andEngineering Division - Permit Office twenty-four (24) hours in advance of commencing utility and/orpaving construction at (713) 316-3561 and written notification forty-eight (48) hours in advance ofcommencing construction at 10555 Northwest Freeway, Suite 146, Houston, TX 77092.SCALE:HORIZ: 1"=20'VERT: 1"=2'4+50 8SENS PARK ROADALIGNMENT APLAN & PROFILESTA 4+50 TO STA 9+00RLREP2016-504Aug 24,2016 - 1:13pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCU1"=20'SENS PARK ROAD (60' R.O.W.)5+005+506+004+506+507+007+508+008+501"=2'SCALE:HORIZ: 1"=20'VERT: 1"=2'9+00100-YEAR FLOOD PLAIN INFORMATION:According to FEMA map no. 48201C0945-L dated effective June 18, 2007 of the FederalEmergency Management Agency's flood insurance rate map for Harris County and incorporatedareas, the subject tract is mostly situated within Shaded Zone "X" defined as areas determined tobe outside the 0.2% annual chance flood and partially within Zone "AE" defined as areasdetermined to be within the 1% annual chance flood (100-year flood) also known as the baseflood with base flood elevations determined. This flood statement does not imply that the propertyor structures thereon will be free from flooding or flood damage. On rare occasions floods can andwill occur and flood heights may be increased by man-made or natural causes.100-year Base Flood Elevation = 20.98'BENCHMARK INFORMATION:1.RM 060040: Floodplain reference number 060040 is described as a brass disk set inconcrete with an elevation of 24.67 feet above mean sea level, N.A.V.D. 1988, 2001adjustment.PERMIT NOTES:2.OWNER OR OWNER'S AGENT to obtain all permits required by the "Regulations of the Cityof La Porte, Texas" prior to starting construction.3.OWNER OR OWNER'S AGENT to obtain all notifications required by Harris County, Texasprior to starting construction of utilities and/or culverts within Harris County and Harris CountyFlood Control District Rights-of-Way.4.The contractor(s) shall notify Harris County Public Infrastructure Department - Architectureand Engineering Division - Permit Office twenty-four (24) hours in advance of commencingutility and/or paving construction at (713) 316-3561 and written notification forty-eight (48)hours in advance of commencing construction at 10555 Northwest Freeway, Suite 146,Houston, TX 77092. 9SENS PARK ROADALIGNMENT APLAN & PROFILESTA 9+00 TO STA 12+50RLREP2016-504Aug 24,2016 - 1:14pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCU1"=20'SENS PARK ROAD (60' R.O.W.)9+5010+0010+509+0011+0010+5011+0011+5012+001"=2'SCALE:HORIZ: 1"=20'VERT: 1"=2'12+5010+00SCALE:HORIZ: 1"=20'VERT: 1"=2'SENS PARK ROAD (60' R.O.W.) 10SENS PARK ROADALIGNMENT APLAN & PROFILESTA 12+50 TO STA 17+00RLREP2016-504Aug 24,2016 - 1:16pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCU1"=20'SENS PARK ROAD (60' R.O.W.)13+0013+5014+0012+5014+5015+0015+5016+0016+5017+001"=2'SCALE:HORIZ: 1"=20'VERT: 1"=2'100-YEAR FLOOD PLAIN INFORMATION:According to FEMA map no. 48201C0945-L dated effective June 18, 2007 of theFederal Emergency Management Agency's flood insurance rate map for Harris Countyand incorporated areas, the subject tract is mostly situated within Shaded Zone "X"defined as areas determined to be outside the 0.2% annual chance flood and partiallywithin Zone "AE" defined as areas determined to be within the 1% annual chanceflood (100-year flood) also known as the base flood with base flood elevationsdetermined. This flood statement does not imply that the property or structuresthereon will be free from flooding or flood damage. On rare occasions floods can andwill occur and flood heights may be increased by man-made or natural causes.100-year Base Flood Elevation = 20.98'BENCHMARK INFORMATION:1.RM 060040: Floodplain reference number 060040 is described as a brass diskset in concrete with an elevation of 24.67 feet above mean sea level, N.A.V.D.1988, 2001 adjustment.PERMIT NOTES:2.OWNER OR OWNER'S AGENT to obtain all permits required by the "Regulationsof the City of La Porte, Texas" prior to starting construction.3.OWNER OR OWNER'S AGENT to obtain all notifications required by HarrisCounty, Texas prior to starting construction of utilities and/or culverts within HarrisCounty and Harris County Flood Control District Rights-of-Way.4.The contractor(s) shall notify Harris County Public Infrastructure Department -Architecture and Engineering Division - Permit Office twenty-four (24) hours inadvance of commencing utility and/or paving construction at (713) 316-3561 andwritten notification forty-eight (48) hours in advance of commencing constructionat 10555 Northwest Freeway, Suite 146, Houston, TX 77092.WATER LINE PROTECTION NOTE:Place one full section (MIN 18 ft) of WL centered atSAN SWR crossing. Provide restrained joints onWL, spaced at least 9 ft horizontally fromcenterline of SAN SWR.Place one full section (MIN 18 ft) of SAN SWRcentered at WL crossing. Provide restrained jointson SAN SWR, spaced at least 9 ft horizontally fromcenterline of WL. Embed SAN SWR with CSS forthe total length of 1 pipe segment plus 1 footbeyond the joints on each end. Both the WL andSAN SWR pipe must be pressure rated (with atleast 150 psi pressure rating). 11SENS PARK ROADALIGNMENT APLAN & PROFILESTA 17+00 TO 20+31.52RLREP2016-504Aug 24,2016 - 1:18pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCU1"=20'SENS PARK ROAD (60' R.O.W.)17+5018+0018+5017+0019+0019+5020+0020+501"=2'SCALE:HORIZ: 1"=20'VERT: 1"=2'100-YEAR FLOOD PLAIN INFORMATION:According to FEMA map no. 48201C0945-L dated effective June 18, 2007 of the FederalEmergency Management Agency's flood insurance rate map for Harris County and incorporatedareas, the subject tract is mostly situated within Shaded Zone "X" defined as areas determined tobe outside the 0.2% annual chance flood and partially within Zone "AE" defined as areasdetermined to be within the 1% annual chance flood (100-year flood) also known as the baseflood with base flood elevations determined. This flood statement does not imply that the propertyor structures thereon will be free from flooding or flood damage. On rare occasions floods can andwill occur and flood heights may be increased by man-made or natural causes.100-year Base Flood Elevation = 20.98'BENCHMARK INFORMATION:1.RM 060040: Floodplain reference number 060040 is described as a brass disk set inconcrete with an elevation of 24.67 feet above mean sea level, N.A.V.D. 1988, 2001adjustment.PERMIT NOTES:2.OWNER OR OWNER'S AGENT to obtain all permits required by the "Regulations of the Cityof La Porte, Texas" prior to starting construction.3.OWNER OR OWNER'S AGENT to obtain all notifications required by Harris County, Texasprior to starting construction of utilities and/or culverts within Harris County and Harris CountyFlood Control District Rights-of-Way.4.The contractor(s) shall notify Harris County Public Infrastructure Department - Architectureand Engineering Division - Permit Office twenty-four (24) hours in advance of commencingutility and/or paving construction at (713) 316-3561 and written notification forty-eight (48)hours in advance of commencing construction at 10555 Northwest Freeway, Suite 146,Houston, TX 77092.N "C" STREET (60' R.O.W.)N. 23RD STREET(60' R.O.W.)N "C" STREET (60' R.O.W.) 12DRAINAGE EASEMENTPLAN & PROFILESTA 0+00 TO STA 5+00RLREP2016-504Aug 24,2016 - 1:34pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCU1"=20'BASELINE "B" - OFFSITE DRAINAGE EASEMENT (20' U.E.)0+501+001+500+002+002+503+003+504+005+501"=2'SCALE:HORIZ: 1"=20'VERT: 1"=2'4+505+00SEE SHEET 9 13DRAINAGE EASEMENTPLAN & PROFILESTA 5+00 TO STA 9+50RLREP2016-504Aug 24,2016 - 2:43pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCU1"=20'BASELINE "B" - OFFSITE DRAINAGE EASEMENT (20' U.E.)5+005+506+004+506+507+007+508+008+501"=2'SCALE:HORIZ: 1"=20'VERT: 1"=2'9+009+50 14DRAINAGE EASEMENTPLAN & PROFILESTA 9+50 TO STA 12+50 ANDBASELINE "C" SANITARY SWRRLREP2016-504Aug 24,2016 - 2:54pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCU1"=20'BASELINE "B" - OFFSITE DRAINAGE EASEMENT (20' U.E.)9+5010+0010+5011+0011+5012+0012+501"=2'SCALE:HORIZ: 1"=20'VERT: 1"=2'BASELINE "C" - 6" SANITARY SEWER0+000+501+001+50SCALE:HORIZ: 1"=20'VERT: 1"=2'WATER LINE PROTECTION NOTE:Place one full section (MIN 18 ft) of WL centered at SAN SWR crossing.Provide restrained joints on WL, spaced at least 9 ft horizontally fromcenterline of SAN SWR.Place one full section (MIN 18 ft) of SAN SWR centered at WL crossing.Provide restrained joints on SAN SWR, spaced at least 9 ft horizontally fromcenterline of WL. Embed SAN SWR with CSS for the total length of 1 pipesegment plus 1 foot beyond the joints on each end. Both the WL and SANSWR pipe must be pressure rated (with at least 150 psi pressure rating). 15BASELINE "D"36" STORM SEWERPLAN & PROFILESTA 0+00 TO STA 4+50 ANDBASELINE "E" SAN SEWERRLREP2016-504Aug 24,2016 - 3:02pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCU1"=20'BASELINE "D" 36-INCH STORM SEWER0+501+001+500+002+002+503+003+501"=2'SCALE:HORIZ: 1"=20'VERT: 1"=2'BASELINE "E" 6-INCH SANITARY0+501+001+500+00SCALE:HORIZ: 1"=20'VERT: 1"=2'WATER LINE PROTECTION NOTE:Place one full section (MIN 18 ft) of WL centered at SAN SWR crossing. Provide restrainedjoints on WL, spaced at least 9 ft horizontally from centerline of SAN SWR.Place one full section (MIN 18 ft) of SAN SWR centered at WL crossing. Provide restrainedjoints on SAN SWR, spaced at least 9 ft horizontally from centerline of WL. Embed SAN SWRwith CSS for the total length of 1 pipe segment plus 1 foot beyond the joints on each end.Both the WL and SAN SWR pipe must be pressure rated (with at least 150 psi pressure rating).0+00 16STORM WATERPOLLUTIONPREVENTION PLANRLREP2016-504Aug 24,2016 - 3:03pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCU1"=100' 17STORM WATERPOLLUTIONPREVENTIONDETAILSRLREP2016-504Aug 24,2016 - 3:09pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCUN.T.S. 18WATER LINEDETAILSRLREP2016-504Aug 24,2016 - 3:08pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCUN/A 19SANITARY SEWERDETAILSRLREP2016-504Aug 24,2016 - 3:10pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCUN/A 20SANITARY SEWERDETAILSRLREP2016-504Aug 24,2016 - 3:11pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCUN/A 21TRENCH SAFETYDETAILSRLREP2016-504Aug 24,2016 - 3:14pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCUN/A 22SIDEWALKDETAILSRLREP2016-504Aug 24,2016 - 3:15pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCUN/A 23CITY OF LA PORTESWPPP DETAILSRLREP2016-504Aug 24,2016 - 3:15pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCUN/A 24PRECAST STORMSEWER DETAILSRLREP2016-504Aug 24,2016 - 3:15pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCUN/A 25PRECAST CONCRETEJUNCTION BOXMANHOLE DETAILSRLREP2016-504Aug 24,2016 - 3:16pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCUN/A 26STORM SEWERCONSTRUCTIONDETAILSRLREP2016-504Aug 24,2016 - 3:16pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCUN/A 27CONCRETEPAVEMENT DETAILSSHEET 1 OF 2RLREP2016-504Aug 24,2016 - 3:16pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCUN/A 28CONCRETEPAVEMENT DETAILSSHEET 2 OF 2RLREP2016-504Aug 24,2016 - 12:14pm08/24/16THIS DOCUMENT IS RELEASEDFOR INTERIM REVIEW ONLY.NOT FOR CONSTRUCTION.DEV-TEX ENGINEERING, LPTEXAS REGISTEREDENGINEERING FIRM# F-79995'0541#& $75+0'552#4- 5GPU2CTM&TKXG#0TF5VTGGV.C2QTVG6GZCUN/A 08/24/16 08/24/16