Loading...
HomeMy WebLinkAboutOAKLAND LAND & DEVELOPMENT 601 S 14TH STC· C· (_� (7: C C 11; C· -,_= Ci 0 ,:· G-'J. b I 'I, I I I I I I I I I ! I I I I I 30"RCP � FT.11--13,2-4 ,,, PJ1 FLW=13.27 __ --j � ,--, I, .• ' II•-·. J . ' II 24" RCl' FLN=l3.13 FL S-13.01 w I 16' -� �,·,,:WEST EST q_ 60' 2'16' lh.l r----==;;;m;;;ea:;;;.,:;:_:, ==--===--r-====------==�=;;;;;::;;;;:=:;;+-r"'__ -,-,.,,-____ ,�.,I-< 128 '.Cl/ STM.MH ,-. DITCH 1�.1 '.2.1 ._,:, I J, I j> :, 4' EL 17.88 S.W.P.P.P. .1 ·-,�' 30''CMPl'Ll! 9.24 i- -°'' I �-/\ ;.,'.\ e I / I I ' II 1-."� � EXISTING SITE PROJECT SWPPP FEATURE ARE TO REMAIN IN PLACE FOR THE PROPOSED DRIVEWAY PROJECT I EL 17.78 1 EL 17.38 2.5%SLOPEPROPOSED DRIVEWAY SECTION A-A HORZ 1" = 10' VERT 1" = 40' SITE KEYNOTES 0 PROPOSED (1) INDUSTRIAL DRIVEWAY; 46' WIDE; 15' RADIUS RETURNS; 8" CONCRETE; PAVING; 3000 PSI, #4@ 12" O.C.; 9" COMPACTED SUBGRADE STABILIZED AS PER SOILS REPORT #16-348 BY COSTAL TESTING (HEAVY TRAFFIC) EXISTING LANDSCAPE 0 EXISTING LANDSCAPE TO REMAIN THE SAME; 3 SHADE TREES & 14SHRUBS TO BE RELOCATED TO EXISTING 4' LANDSCAPING STRIP EAST OF PROPOSED DRIVEWAY. REFERENCE NOTE 6 THIS SHEET. •Required landscaping to be located between fence and the R.O.W.•Landscaping shall be in accordance with the visibility triangle requirements•EXISTING irrigation SYSTEMA y PROPOSED ORNAMENTAL TREE (OVERHEAD UTILITY) 1 per 20 1.f. of R.O.W. (400' 14TH ST) YAUPON HOLLY TREE (ILEX VOMITORIA) (20 TYP.) 20' O.C.E.W PROPOSED SHADE TREE 1 PER 30 L.F. (266' + 266' + 80' = 612'/30) TEXAS RED OAK TREE (QUERCUS TEXANA) (20 TYP.) 30' O.C.E.W PROPOSED 5 GALLON MIN. OLEANDER SHRUBS (NERIUM OLEANDER) (167 TYP.) 3' O.C.E.W. TOTAL AREA OF EXISTING SITE 204,800 SQ. FT. / 4.7 AC EXISTING PARKING TO REMAIN THE SAME PARKING TABLE 601 S 14TH STREET; SHELL BUILDING; SEE TITLE BLOCK NOTE #6 PROPOSED PARKING SPACES = 8 SP (9' x 20') PROPOSED PARKING SPACES = 5 SP (9' x 18') PROPOSED H.C. VAN SPACE = 1 SP (9' X 18') TOTAL PROPOSED = 14 SPACES 631 S 14TH ST; OFFICE/ SHOP: 4 MIN+ 1 PER EMPWYEE 2012 NAICS CODE: 8113, COMMERCIAL & INDUSTRIAL MACHINERY & EQUIPMENT 4 MINIMUM PLUS 2 PER 1,000 S.F. OF SHOP AREA (1,950 s.f./ 1000)*2= 4 + 4 MIN = 8 SP Required PROPOSED PARKING SPACES = 8 SP (9' X 20') PROPOSED PARKING SPACES = 7 SP (9' X 18') PROPOSED H.C. VAN SPACE = 1 SP (9' X 18') TOTAL PROPOSED = 16 SPACES 1306 W. F STREET; OFFICE / SHOP 2012 NAICS CODE: 8113, COMMERCIAL & INDUSTRIAL MACHINERY & EQUIPMENT 4 MINIMUM PLUS 2 PER 1,000 S.F. OF SHOP AREA (9,660 s.f./ 1000)*2 = 19+4 MIN = 23 SP Required PROPOSED PARKING SPACES = 15 SP (9' X 20') PROPOSED PARKING SPACES = 7 SP (9' X 18') PROPOSED H.C. VAN SPACE = 1 SP (9' X 18') TOTAL PROPOSED = 23 SPACES UTILITY NOTES (EXISTING UTILITIES, 1.NO PROPOSED UTILITIES IN THIS PROJECT2.NOTIFY PUBLIC WORKS AT 281-471-9650 48 HOURS PRIOR TO ANY UTILITY CONNECTIONS3.IF ANY EXISTING UTILITIES REQUIRE AN ELEVATION ADJUSTMENT DUE TO THE PROPOSEDDEVELOPMENT, THOSE ADJUSTMENTS WILL BE THE RESPONSIBILITY OF THE CONTRACTORAT THE DEVELOPER'S / CONTRACTOR'S EXPENSE. THIS PERTAINS TO STORM WATER INLETS,MAIN OR MANHOLES, WATER OR SANITARY SEWER MAIN, SANITARY MANHOLES ORCLEANOUTS, FIRE HYDRANTS OR VALVE BOXES. ALL UTILITIES WILL BE ADJUSTED INCONFORMANCE WITH CITY SPECIFICATIONS.EXISTING UTILITY LEGEND -11 -11 -EXISTING WATER LINE, SIZE AS NOTED _,.._,.._ EXISTING IRRIGATION LINE -S'I/R--SIIR-EXISTING 6" SANITARY SEWER LINE -GIi --GIi -EXISTING GREASE TRAP WASTE LINE-E -E -EXISTING U.G ELECTRICAL LINE-TEL--TEL-EXISTING U.G. TELEPHONE LINETHIS IS TO CERTIFY THAT THE CITY OF LA PORTE, TEXAS HAS APPROVED THIS SITE PAN AND DEVELOPMENT OF OAKLAND LAND & DEVELOPMENT "OFFICE WAREHOUSE" IN CONFORMANCE WITH THE LAWS OF THE STATE OF TEXAS AND THE ORDINANCES OF THE CITY OF LA PORTE. BY: BY: ------------------DIRECTOR OF PLANNING LA PORTE, TX ------------------CITY PLANNER, LA PORTE TX CITY OF LA PORTE KEY MAP PG: 580-A ZONING (LI) LIGHT INDUSTRY. HCAD #024-108-001-0001 COLP PROJECT # 19-82000005 TYPE OF DEVELOPMENT: PROPOSED (1) INDUSTRIAL DRIVEWAY; 46' WIDE; 15' RADIUS RETURNS; 8" CONC. DESCRIPTION OF LAND: BLOCK: LOT: 827 1-8, 25-32, & Abandoned 16' alleyADDRESS: CO<><TY 601 S 14TH STREET LA PORTE HARRIS PURCHASER/OWNER: TITLE COMPANY: OAKLAND LAND & DEVELOPMENT, LLC FLOOD STATEMENT: SUBJECT PROPERTY IS LOCATED IN SHADED ZONE "X" AS PER COMMUNITY PANEL NO. 48201C094M DATED JANUARY 6, 2017. BFE=15.30 NORTH ARROW & DRAWING SCALE z 0 1-[l_ c:: () CJ) w 0 o 1 o· 40•80' 0 z Sitework Consulting Engineer FIRM NO 13756 1 INCH = 40 FT.REGISTERED ENGINEER: I, PHILLIP E. JOHNSON , A LICENSED PROFESSIONAL ENGINEER IN THE STATE OF TEXAS DO HEREBY CERTIFY THAT THE INFORMATION PRESENTED ON THIS MINOR SITE PLAN TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. NOTES: 1.NO PROPOSED BUILDING, WATER, ELECTRICAL, GAS, OR SANITARYSERVICES.2.NO PROPOSED WATER METER OR IRRIGATION METER.3.EXISTING DIRT SPOILS ARE OF HIGH PLASTIC AND ARE NOT SUITABLEFOR CONSTRUCTION OR BACKFILL. DIRT SPOILS ARE REMOVED OFFPROPERIT BY CONTRACTOR.4. UNKNOWN TENANT. 601 14TH STREET IS A SHELL BUILDING. ANYFUTURE TENANT OR CHANGE IN TENANT WOULD REQUIRE A NEWZONING PERMIT.5.A STORM WATER QUALITY PERMIT IS REQUIRED BEFORE ANY DIRT ISDISTURBED ON SITE.6.IF THE SITE REQUIRES THE REMOVAL OF ANY TREES, A CLEARINGPERMIT WILL NEED TO BE OBTAINED.7.A FILL DIRT PERMIT IS REQUIRED FOR ANY FILL IMPORTED TO THESITE.8.ALL OF THESE PERMITS, WHERE APPLICABLE, MUST BE OBTAINEDPRIOR TO THE ISSUANCE OF A PERMIT.S.W.P.P.P. LEGEND (ADDITIONAL l AREAS WHERE STREET SWEEPING WILL BE CONDUC!'ED DAILY CONCRETE TRUCK WASHOUT AREA r,;;;;-, INLET PROTECTIONt..::J BARRIER1.ALL SUBCONTRACTORS WILL BE EDUCATED TO FOLWW STORM WATERPOLLUTION PREVENTION REQUIREMENTS.z <( ...J a.. a.. a.. a.. en oes � � -...J -I-=> w I--en 2.STRUCTURAL BMPS WILL BE INSPECTED AND MAINTAINED AT LEAST EVERY 14 JOB NO 19-0003 DAYS AND AFTER ANY PRECIPITATION OR RUNOFF EVENT THAT CAUSES SURFACE I-'-'--_;_-· --------,EROSION, SEDIMENT TRANSPORT OR VEHICULAR TRACKING. DRWN BY: RC 3.REGULAR SCRAPING AND SWEEPING OF STREETS, SIDEWALKS AND FLOW LINESMUST BE CONDUCTED. CKD BY: PEJ 4.EARTH MATERIALS AND LANDSCAPE MATERIALS SUCH AS SOD, ROCK AND MULCH FILE· C1 Q d g SHALL NOT BE STOCKPILED, PLACED OR STORED ON DRIVEWAYS,STREETS, · · · W SIDEWALKS OR IN STORM WATER FLOW LINES. SCALE: 5.CONSTRUCTION SUPPLIES (E.G. TRUSSES AND LUMBER), ROLL OFF CONTAINERS,DUMPSTERS, PORTABLE TOILETS, TRAILERS, ETC. SHALL NOT BE STORED ON DATE: Fri, Mar 29 2019STREETS OR SIDEWALKS OR OTHER IMPERVIOUS SURFACES. THESE ITEMS SHALLBE STORED ON THE CONSTRUCTION SITE OR STAGING AREAS.DWG: 6.SANITARY FACILITIES SHALL BE LOCATED ON NATURAL GROUND AND AT LEAST 25FEET FROM ANY STORM SEWER INLET OR WATER BODY AND SHALL BE SERVICED C 1 oREGULARLY.•CITY ENGINEER, LA PORTE TX BY: ------------------