HomeMy WebLinkAboutSNAPP USA SITE PLANNURSERY GROWN CONTAINERIZED TREES
SHRUB/GROUND COVER
SOLID SOD - COMMON BERMUDA
HYRDOMULCH - COMMON BERMUDA
L E G E N D
1
PREMIUM BED MIX' BY THE GROUND UP
CONTACT AT 832-247-2574
CONTACT AT 713-466-7360 OR 281-342-6113
2
3
4
5
6
7
BIDDING CONTRACTORS BE ADVISED THAT ALL NEW TREE MATERIAL IS TO BE CONTAINER GROWN,
CORRESPONDING TO STATED ROOT BALL SIZES AS RECOGNIZED BY INDUSTRY STANDARDS. THIS SHALL
EXCLUDE ALL B&B, MACHINE MOVED, OR TRANSPLANTED TREES FROM THE BIDDING PROCESS UNLESS
OTHERWISE INDICATED ON THE PLAN. THE INSTALLATION CONTRACTOR SHALL BE PREPARED TO PROVIDE
PHOTOGRAPHS OF INTENDED PLANT MATERIAL ALONG WITH SIGNED CLARIFICATION THAT PLANT MATERIAL
MEETS THESE REQUIREMENTS AND THAT NO VARIATIONS OR SUBSTITUTIONS HAVE BEEN MADE.
OR
LANDSCAPE MIX (GROUND LEVEL ONLY)
ALL TREES PLANTED ADJACENT TO ACCESSIBLE ROUTES AND ACCESSIBLE AREAS SHALL NOT HAVE LIMBS
BELOW 80" (IN) A.F.F.
ALL DISTURBED AREAS ARE TO RECIVE 4" (IN) OF TOPSOIL, TOPPED WITH MULCH, SOD, OR HYDROMULCH
(DEPENDING ON THE AREA), AND IS TO BE WATERED UNTIL A HEALTHY STAND OF GRASS IS ESTABLISHED.
CONTRACTOR IS RESPONSIBLE FOR THE GRADING OF PARKING LOT ISLANDS AND SETBACKS. GRADE
CHANGES SHALL RANGE FROM 8" (IN) TO 15" (IN) ABOVE THE CURB, DEPENDING ON THE SIZE OF THE ISLAND.
SELECT TOPSOIL SHALL BE USED FOR THESE BERMS. SEE PARKING ISLAND TREE DETAIL.
IF THE PLANTING PLAN DOES NOT AGREE WITH THE PLANT LIST, THE QUANTITIES INDICATED GRAPHICALLY ON
THE PLANTING PLAN SHALL GOVERN.
THE LANDSCAPE CONTRACTOR DOING THE INSTALLATION OF THIS WORK SHALL SUBMIT TO KUDELA &
WEINHEIMER INFORMATION REGARDING SOURCING OF PLANT MATERIAL. ALL PLANT MATERIAL MUST BE
CONTAINER GROWN AND APPROVED AT THE SOURCE OF GROWTH BY KUDELA & WEINHEIMER. TREE
MATERIAL MEETING THE SPECIFICATIONS WILL BE TAGGED WITH A SERIALIZED LOCKING TAG AT THE NURSERY
BY KUDELA & WEINHEIMER. PLANTS ARRIVING AT THE JOB SITE WITHOUT THESE TAGES WILL BE
CATEGORICALLY REJECTED AT THE CONTRACTOR'S EXPENSE.
P L A N T I N G N O T E S
"ULTRA SOIL" BY LIVING EARTH TECHNOLOGY GROUP
PLANTING SOIL MIXTURE SHALL BE ONE OF THE FOLLOWING:
ON GRADE ONLY
NURSERY GROWN CONTAINERIZED TREES
SHRUB/GROUND COVER
SOLID SOD - COMMON BERMUDA
HYRDOMULCH - COMMON BERMUDA
L E G E N D
I R R I G A T I O N N O T E S
IRRIGATION SYSTEM SHALL COMPLY WITH THE FOLLOWING:
1) NEW COMPONENTS OF IRRIGATION SYSTEM SHALL INCLUDE: CONTROLLER,
IRRIGATION VALVES, ADDITIONAL 2 1/2" PVC MAINLINE, PVC LATERAL LINES
SIZING 2" TO 3/4", RAIN SENSOR, WIRING, GATE VALVES, VALVES BOXES, QUICK
COUPLERS, 2" (IN) METER AND BACKFLOW PREVENTER: AND ALL OTHER
COMPONETS FOR A COMPLETE IRRIGATION SYSTEM.
SYM.
BOTANICAL NAME /
COMMON NAME CAL. HEIGHT SPREAD
MIN.
ROOT REMARKS
TREES
LO QUERCUS VIRGINIANA
LIVE OAK 2 1/2" - 3 1/2" 12' - 14' 8' - 10' 30 GAL. MATCHED, WELL ROOTED
LO1 QUERCUS VIRGINIANA 'CATHEDRAL'
CATHEDRAL LIVE OAK 2 1/2" - 3 1/2" 12' - 16' 6' - 7' 30 GAL. MATCHED, WELL ROOTED
SHRUBS
WL LIGUSTRUM JAPONICUM
WAX LEAF LIGUSTRUM 24" 24" 5 GAL.
FULL, WELL ROOTED
30" O.C.
OL NERIUM OLEANDER
COMMON OLEANDER 18" 15" 3 GAL.
FULL, WELL ROOTED
30" O.C.
GROUNDCOVER
GL LIRIOPE MUSCARI 'GIGANTEA'
GIANT LIRIOPE 12" - 14" 12" 3 GAL.
FULL, WELL ROOTED
18" O.C.
NG LANTANA SP. 'NEW GOLD'
NEW GOLD LANTANA 10" 8" 1 GAL.
FULL, WELL ROOTED
18" O.C.
TURF
CYNODON DACTYLON
COMMON BERMUDA HYRDROMULCH
CYNODON DACTYLON
COMMON BERMUDA SOLID SOD
P L A N T L I S T
1
A.
Street Name Lineal Feet Tree Planting
Requirement
FAIRMONT PARKWAY 845 / 20 42
B. PARKING LOT TREES: Sec. 106-800 €
> Parking lot with minimum 20 spaces shall provide a planter at the ratio of one for every ten parking spaces.
Total # of Proposed
Parking Spaces # of Spaces Tree Planting
Requirement
Planters
Sq. Ft.
Planters Required
Total Sq. Ft.
52 52 / 10 6 135 x 6 810
Total # of Proposed
Parking Spaces # of Spaces Tree Planting
Requirement
Total Trees
Planted
52 52 / 10 6 6
C. SHRUBS: Sec. 106-800 ( c)
>Shrubs are required in the planting strip adjecent to the right-of-way and shall be placed at three feet on center.
Equivalent Credits Total Trees Planted
CITY OF LA PORTE TREE ORDINANCE
LANDSCAPE ANALYSIS FORM
NON-SINGLE FAMILY RESIDENTIAL
TREE AND SHRUB PLANTING REQUIREMENTS
STREET TREES: Sec. 33-126 (a)
Length of property in lineal feet as measured along each street separately
0 42
TOTAL STREET TREES 42
> Planters (minimum 135 sq ft) each required planter shall have one shade tree.
Trees shall be dispersed throughout the parking lot to maximize shadding
BF
CONTROLLER:
1 1/2" BACKFLOW PREVENTER
HUNTER ACC
RAIN SENSOR:
1 1/2" WATER METER
C RS
6"
6"
6"6"6"6"6"6"
6"
NOTE: COMPONENTS ARE
SHOWN FOR DESIGN
AND BIDDING PURPOSES.
EXACT LOCATION SHALL
BE FIELD VERIFIED PRIOR
TO CONSTRUCTION.
"1
"1 "1211"211""1 211""1"1211"211"211"
211"
43"
43"
211"
43"43"
43"
43"43"43""1
"143"
43"43"43"43"211"
43"
43"
2"
331.7
2"
445.3
2"
38.85
2"
728.9
2"
841.9
2"
45.29
221"
43"43"43"43"43"43"
"1"1211"
"143""1
"1
2"
34.06
HUNTER SOLAR-SYNC
43"43"
221"
"4 "4
"1
"1
211"
211"
211"
43""1
2"
138.2
2"
225.3
43""1
211"
43"
"1
211"43"
43"
6"43"
43"
"1
211"
43"221"
211"
"1
2 "211"
2 "
"1
"1
2 "
"1
"1
43"
43"
211"
211"
43"
211"
43"
43"43"
43"
211"
"1 211"211"
"1 "1
43"
43"
43"
43"
43"
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI
Hunter PROS-04-CV 5` strip spray
Turf Spray, 4.0" Pop-Up. With Drain Check Valve.
Co-molded wiper seal with UV Resistant Material.
12 20
Hunter PROS-04-CV ADJ
Turf Spray, 4.0" Pop-Up. With Drain Check Valve.
Co-molded wiper seal with UV Resistant Material.
109 20
Tree Bubbler Hunter PCN Flood Bubbler
(TWO PER TREE) See TREE BUBBLER DETAIL for
proper installation. Provide separate zone for all tree
bubblers, do not connect to shrub, tree, or sod zones.
68 15
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI GPM RADIUS
Hunter PGP-04-MPR
Turf Rotor, 4.0" Pop-Up. Adjustable to Full Circle.
MPR Nozzle.
36 25 32'
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
Hunter ICV-G
1", 1-1/2", 2", and 3" Plastic Electric Remote Control
Valves, Globe Configuration, with NPT Threaded
Inlet/Outlet, for Commercial/Municipal Use.
8
Febco 765 1-1/2"
Pressure Vacuum Breaker, brass with ball valve SOV.
Install 12" (305MM) above highest downstream outlet
and the highest point in the downstream piping.
1
Hunter ACC-1200
12 Station Outdoor Modular Controller. No Module
Required. High-End Commercial Use. Metal Cabinet.
1
Hunter WSS
Wireless Solar, rain freeze sensor with outdoor
interface, connects to Hunter PCC, Pro-C, and I-Core
Controllers, install as noted. Includes 10 year lithium
battery and rubber module cover, and gutter mount
bracket.
1
Water Meter 1-1/2"
City Tap
1
Irrigation Lateral Line: PVC Class 200 SDR 21 2,855 l.f.
Irrigation Lateral Line: PVC Class 200 SDR 21 1,138 l.f.
Irrigation Mainline: CPVC Schedule 40 693.5 l.f.
Pipe Sleeve: CPVC Schedule 40 406.1 l.f.
BF
C
RS
Hunter PROS-12 5` strip spray
Shrub Spray, 12.0" Pop-Up. Co-molded wiper seal with
UV Resistant Material.
23 20
IRRIGATION SCHEDULE
P.O.C. NUMBER: 01
Water Source Information:City Tap
FLOW AVAILABLE
Water Meter Size:1-1/2"
Flow Available:75.00 gpm
PRESSURE AVAILABLE
Static Pressure at POC:50.00 psi
Elevation Change:5.00 ft
Service Line Size:2"
Length of Service Line:20.00 ft
Pressure Available:47.00 psi
DESIGN ANALYSIS
Maximum Station Flow:45.29 gpm
Flow Available at POC:75.00 gpm
Residual Flow Available:29.71 gpm
Critical Station:6
Design Pressure:25.00 psi
Friction Loss:4.19 psi
Fittings Loss:0.42 psi
Elevation Loss:0.00 psi
Loss through Valve:0.80 psi
Pressure Req. at Critical Station: 30.40 psi
Loss for Fittings:0.19 psi
Loss for Main Line:1.90 psi
Loss for POC to Valve Elevation: 0.00 psi
Loss for Backflow:2.59 psi
Loss for Water Meter:1.69 psi
Critical Station Pressure at POC: 36.77 psi
Pressure Available:47.00 psi
Residual Pressure Available:10.23 psi
CRITICAL ANALYSIS
VALVE
SCHEDULE
NUMBER MODEL SIZE TYPE GPM PSI @ POC
1 Hunter ICV-G 2" Turf Rotor 0.00
2 Hunter ICV-G 2" Shrub Spray 25.30
3 Hunter ICV-G 2" Turf Rotor 31.65 36.37
4 Hunter ICV-G 2" Turf Spray 45.29 33.90
5 Hunter ICV-G 2" Turf Spray 38.84 32.24
6 Hunter ICV-G 2" Bubbler 34.00
7 Hunter ICV-G 2" Turf Rotor 28.90 36.77
8 Hunter ICV-G 2" Turf Spray 41.87 35.08
9 Hunter ICV-G 2" Turf Spray 45.17 36.74
WALL MOUNTED CONTROLLER
NO SCALE
CONTROLLER AS SPECIFIED
HARD WIRE 117 VOLT A.C. POWER OUTLET BEHIND
CONTROLLER
KEYED LOCK OR PAD LOCK
PLAN
ELEVATION
SCHEDULE 80 PVC MALE CONNECTOR
11/4" RIGID STEEL CONDUIT
STEEL SPLICE ACCESS PANEL
RIGID STEEL CONDUIT- set plumb
SCHEDULE 80 PVC COUPLING
SCHEDULE 80 PVC SWEEP ELL
6' LONG COPPER GROUND ROD-
connect to ground terminal on the controller
WALL
LAG BOLTS OR EXPANSION BOLTS AS REQUIRED
CONTROLLER BOX
HARD WIRE 117 VOLT A.C. POWER SUPPLY
BEHIND CONTROLLER IN FLUSH BOX
1/2" STEEL CONDUIT
10
5
NO SCALE
RAIN SENSOR
CONDUIT THROUGH WALL BY
ELECTRICAL CONTRACTOR.
J-BOX BY ELECTRICALCONTRACTOR
PARAPET COPINGPLACE RAIN SENSORJUST BELOW PARAPET
COPING.
RAIN SENSOR: HUNTERMINI-CLIK-C WITHFEMALE THREADED INLET.
ELECTRICAL CONDUIT TO
RAIN SENSOR BYIRRIGATION CONTRACTOR.
ROOF OF BUILDING
CONDUIT W/ PULL WIRE TOCONTROLLER BY ELECTRICAL
CONTRACTOR.
NO SCALE
REMOTE CONTROL VALVE DETAIL
PEA GRAVEL
REMOTE CONTROL VALVE
W/24" LONG LOOP OF CONTROL WIRE
45 DEGREE ELBOW
SCHEDULE 40 PVC
FITTING
MAINLINE
VALVE BOX FLUSH WITH FINISH GRADE
7
FINISH GRADE
SPECIFIED SPRAY BODY AND NOZZLE
CLASS 200 PVC LATERAL LINE
HIGH-POP SPRAY HEAD DETAIL
NO SCALE
PVC SCHEDULE 40 OUTLET TEE OR ELL
RAINBIRD SWING ASSEMBLYMODEL SA 127575:1/2" BY 12" LONG
ORHUNTER SWING JOINTMODEL SJ-712:
1/2" BY 12" LONG
8
NO SCALE
FINISH GRADE
CLASS 200 LATERAL LINE
GEAR DRIVEN ROTOR HEAD
GEAR DRIVEN ROTOR HEAD AS SPECIFIED
set top of body flush with finish grade
SCH 40 PVC TEE
RAINBIRD SWING ASSEMBLYMODEL SA 127057:
3/4" BY 12" LONG
ORHUNTER SWING JOINTMODEL SJ-512:
3/4" BY 12" LONG
6 GATE VALVE DETAIL
NO SCALE
FINISH GRADE
6" PVC PIPE
VALVE BOX
GATE VALVE - LINE SIZE
PEA GRAVEL
BRICK (2 TOTAL)
PVC MAIN LINE
PEA GRAVEL (6" DEPTH)
3
NO SCALE
BACKFLOW VALVE COVER2
GUARD SHACK VANDAL &THEFT RESISTANT ENCLOSURE,
'LIFT OFF MODEL' COLOR TOBE GREEN. INSTALL PERMANUFACTURERS SPECS.
COMPACTED
SUBGRADE
CONCRETE PAD,PER MANUFACUTERSSPECS.
NO SCALE
COPPER NIPPLE
COPPER 90 DEGREE
ELBOW
COPPER NIPPLE
COPPER UNION
COPPER NIPPLE
(LENGTH AS REQUIRED)
ADAPT INLET AND
OUTLET AS REQUIRED
MAINLINE FROM SOURCE12" MINIMUM 30" MAX.BACKFLOW PREVENTOR
NOTE: WRAP ALL ABOVE
GROUND COMPONENTS
WITH INSULATION FORFREEZE PROTECTION ORINSTALL INSULATED
FIBERGLASS ENCLOSURE.
1
WYE STRAINER
VALVE BOX FLUSH WITH FINISH GRADE
PVC MAIN LINE
SCH 40 PVC TEE
SCH 80 ELL
QUICK COUPLING VALVE DETAIL
NO SCALE
1/2" x 24" STEEL STAKE
3/4" x 12" GALVANIZED STEEL NIPPLE
QUICK COUPLING VALVE
3/4" x 3" SCH 80 NIPPLE
4
FINISH GRADE
9
FINISH GRADE
ROOT BALL
4" DIA. PVC INSPECTION
TUBE -
see tree planting detail
BUBBLER HEAD - Place
bubbler head on top of rootball,
two bubblers per tree
SCH 40 PVC NIPPLE
SCH 40 PVC TEE OR ELL
PVC LATERAL LNE
BUBBLER DETAIL
NO SCALE
1/2" FLEX PVC
ENGINEER'S CERTIFICATIONFLOOD PLAIN STATUSFLOOD CONTROL DISTRICT CRITERIADESCRIPTION OF PROPERTYHCED SIGNATURE BLOCK COMMERCIAL / OTHER SITE DRAINAGEWATER AND WASTEWATERHARRIS COUNTYENGINEERING DEPARTMENTREVIEW SHEETHARRIS COUNTY FLOOD CONTROL DISTRICTENGINEERING DIVISIONPAVINGDRIVEWAYS (in H.C. ROW only)TRAFFIC CONSIDERATIONS RESIDENTIAL / SUBDIVISION DRAINAGE1.3.4.5.2.7.8. CURBING FIRE APPARATUS ACCESS ROADCURB RAMPS 11.****(2001 ADJ.)6.STORMWATER QUALITY WORK IN HCFCD RIGHT-OF-WAY9.LANDSCAPING 12.PERMITS REQUIRED10. WORK IN HARRIS COUNTY R.O.W.IF YES, CHECK THE BOX THAT APPLIES TO THIS PROJECTTO BE FILLED OUT BY HARRIS COUNTYNOTE: ALL EXISTING AND PROPOSED UTILITIES MUST BEACCURATELY SHOWN & LABELED ON THE SITE PLANS.NOTE: SEPTIC SYSTEMS REQUIRE H.C. WASTE WATER REVIEWNOTE: PUBLIC UTILITIES REQUIRE A LETTER FROM THE DISTRICT/MUNICIPALITY AUTHORIZING SERVICE & CONNECTION.THIS IS REQUIRED FOR PLAN APPROVAL.NOTE: ALL ROADSIDE DITCH OUTFALLS REQUIRE EROSION CONTROL MEASURES.RIPRAP IS NOT ALLOWED AS AN EROSION CONTROL MEASURE IN HARRIS COUNTY ROW.ALL PUMPED DETENTION OUTFALLS TO ROADSIDE DITCHES REQUIRE MANHOLE W/ LEADS.DOES THE PROPERTY HAVE ANY VIOLATIONS? IF SO PLEASE PROVIDEALL VIOLATION NUMBERS.DESIGNTHICKNESSOF PAVINGSTABILIZEDSUBGRADEDEPTHDESIGNSTRENGTHOF CONCRETESTEEL SPACINGLONG. TRANS.(IN.)(IN.)(PSI)(IN.) (IN.)NOTE: ALL APPROVED, FINAL PLATS AND ASSOCIATEDCPC101 FORMS MUST BE INCLUDED WITH PLAN SUBMITTAL.OFFSITE SHEET FLOW: (100 YEAR)OFFSITE SHEET FLOW MAPPING, TOTAL DISCHARGE CALCULATIONS, ANDDESIGN ACCOMODATIONS ARE SHOWN ON SHEET _____ OR, AS PRESENTEDIN THE APPROVED DRAINAGE STUDY ENTITLED _________________________.TOTAL ACREAGE = _____TOTAL DISCHARGE = _____NOTE: ALL OFFSITE SHEET FLOW FROM ADJACENT PROPERTIES MUST BEIDENTIFIED AND PROPERLY ACCOUNTED FOR IN THE PROJECT. THE SIGNINGENGINEER HEREBY CERTIFIES THAT THESE AREAS HAVE BEEN ADDRESSED.NOTE: A COPY OF TCEQ APPROVAL FOR PRIVATE WATER &WASTE WATER SYSTEMS IS REQUIRED FOR PLAN APPROVAL.BENCHMARK REQUIREMENTS FORPROPOSED BRIDGES AND OR NEW RESIDENTIAL SUBIDIVSIONSWhen the County Engineer has determined that a new benchmark will be required to be established forthe proposed project, the developer shall be required to install a benchmark per section 8.0, part 2 of theHarris County Infrastructure Regulations.Is a new Benchmark required for this project? (to be determined by Harris County) [__] yes [__] noIf a new Benchmark is required, the proposed benchmark information is shown on sheets ____NOTE: DEDICATED UNDERGROUND FIRE LINES MUST BE SUBMITTED TOTHE HARRIS COUNTY FIRE PROTECTION GROUP FOR REVIEW ANDPERMITTING BY THE UNDERGROUND FIRE LINE CONTRACTOR. CIVILREIVEW DOES NOT REVIEW OR APPROVE UNDERGROUND FIRE LINES FORTHE FIRE PROTECTION SYSTEMS.(#4 MIN.)REINFORCESTEELSIZE
³
³
³
Ɵon that is privileged and confidenƟal
ELEVATION SOUTH NORTH EAST WEST TOTAL SF
PERCENT OF BRICK PROVIDED
PERCENT OF BRICK REQUIRED
Ɵon that is privileged and confidenƟal
EXTERIOR MATERIALS SCHEDULE
CODE MATERIAL MANUFACTURER DESCRIPTION COLOR REMARKS
Ɵon that is privileged and confidenƟal
EXTERIOR MATERIALS SCHEDULE
CODE MATERIAL MANUFACTURER DESCRIPTION COLOR REMARKS
Ɵon that is privileged and confidenƟal
EXTERIOR MATERIALS SCHEDULE
CODE MATERIAL MANUFACTURER DESCRIPTION COLOR REMARKS