Loading...
HomeMy WebLinkAboutSNAPP USA SITE PLANNURSERY GROWN CONTAINERIZED TREES SHRUB/GROUND COVER SOLID SOD - COMMON BERMUDA HYRDOMULCH - COMMON BERMUDA L E G E N D 1 PREMIUM BED MIX' BY THE GROUND UP CONTACT AT 832-247-2574 CONTACT AT 713-466-7360 OR 281-342-6113 2 3 4 5 6 7 BIDDING CONTRACTORS BE ADVISED THAT ALL NEW TREE MATERIAL IS TO BE CONTAINER GROWN, CORRESPONDING TO STATED ROOT BALL SIZES AS RECOGNIZED BY INDUSTRY STANDARDS. THIS SHALL EXCLUDE ALL B&B, MACHINE MOVED, OR TRANSPLANTED TREES FROM THE BIDDING PROCESS UNLESS OTHERWISE INDICATED ON THE PLAN. THE INSTALLATION CONTRACTOR SHALL BE PREPARED TO PROVIDE PHOTOGRAPHS OF INTENDED PLANT MATERIAL ALONG WITH SIGNED CLARIFICATION THAT PLANT MATERIAL MEETS THESE REQUIREMENTS AND THAT NO VARIATIONS OR SUBSTITUTIONS HAVE BEEN MADE. OR LANDSCAPE MIX (GROUND LEVEL ONLY) ALL TREES PLANTED ADJACENT TO ACCESSIBLE ROUTES AND ACCESSIBLE AREAS SHALL NOT HAVE LIMBS BELOW 80" (IN) A.F.F. ALL DISTURBED AREAS ARE TO RECIVE 4" (IN) OF TOPSOIL, TOPPED WITH MULCH, SOD, OR HYDROMULCH (DEPENDING ON THE AREA), AND IS TO BE WATERED UNTIL A HEALTHY STAND OF GRASS IS ESTABLISHED. CONTRACTOR IS RESPONSIBLE FOR THE GRADING OF PARKING LOT ISLANDS AND SETBACKS. GRADE CHANGES SHALL RANGE FROM 8" (IN) TO 15" (IN) ABOVE THE CURB, DEPENDING ON THE SIZE OF THE ISLAND. SELECT TOPSOIL SHALL BE USED FOR THESE BERMS. SEE PARKING ISLAND TREE DETAIL. IF THE PLANTING PLAN DOES NOT AGREE WITH THE PLANT LIST, THE QUANTITIES INDICATED GRAPHICALLY ON THE PLANTING PLAN SHALL GOVERN. THE LANDSCAPE CONTRACTOR DOING THE INSTALLATION OF THIS WORK SHALL SUBMIT TO KUDELA & WEINHEIMER INFORMATION REGARDING SOURCING OF PLANT MATERIAL. ALL PLANT MATERIAL MUST BE CONTAINER GROWN AND APPROVED AT THE SOURCE OF GROWTH BY KUDELA & WEINHEIMER. TREE MATERIAL MEETING THE SPECIFICATIONS WILL BE TAGGED WITH A SERIALIZED LOCKING TAG AT THE NURSERY BY KUDELA & WEINHEIMER. PLANTS ARRIVING AT THE JOB SITE WITHOUT THESE TAGES WILL BE CATEGORICALLY REJECTED AT THE CONTRACTOR'S EXPENSE. P L A N T I N G N O T E S "ULTRA SOIL" BY LIVING EARTH TECHNOLOGY GROUP PLANTING SOIL MIXTURE SHALL BE ONE OF THE FOLLOWING: ON GRADE ONLY NURSERY GROWN CONTAINERIZED TREES SHRUB/GROUND COVER SOLID SOD - COMMON BERMUDA HYRDOMULCH - COMMON BERMUDA L E G E N D I R R I G A T I O N N O T E S IRRIGATION SYSTEM SHALL COMPLY WITH THE FOLLOWING: 1) NEW COMPONENTS OF IRRIGATION SYSTEM SHALL INCLUDE: CONTROLLER, IRRIGATION VALVES, ADDITIONAL 2 1/2" PVC MAINLINE, PVC LATERAL LINES SIZING 2" TO 3/4", RAIN SENSOR, WIRING, GATE VALVES, VALVES BOXES, QUICK COUPLERS, 2" (IN) METER AND BACKFLOW PREVENTER: AND ALL OTHER COMPONETS FOR A COMPLETE IRRIGATION SYSTEM. SYM. BOTANICAL NAME / COMMON NAME CAL. HEIGHT SPREAD MIN. ROOT REMARKS TREES LO QUERCUS VIRGINIANA LIVE OAK 2 1/2" - 3 1/2" 12' - 14' 8' - 10' 30 GAL. MATCHED, WELL ROOTED LO1 QUERCUS VIRGINIANA 'CATHEDRAL' CATHEDRAL LIVE OAK 2 1/2" - 3 1/2" 12' - 16' 6' - 7' 30 GAL. MATCHED, WELL ROOTED SHRUBS WL LIGUSTRUM JAPONICUM WAX LEAF LIGUSTRUM 24" 24" 5 GAL. FULL, WELL ROOTED 30" O.C. OL NERIUM OLEANDER COMMON OLEANDER 18" 15" 3 GAL. FULL, WELL ROOTED 30" O.C. GROUNDCOVER GL LIRIOPE MUSCARI 'GIGANTEA' GIANT LIRIOPE 12" - 14" 12" 3 GAL. FULL, WELL ROOTED 18" O.C. NG LANTANA SP. 'NEW GOLD' NEW GOLD LANTANA 10" 8" 1 GAL. FULL, WELL ROOTED 18" O.C. TURF CYNODON DACTYLON COMMON BERMUDA HYRDROMULCH CYNODON DACTYLON COMMON BERMUDA SOLID SOD P L A N T L I S T 1 A. Street Name Lineal Feet Tree Planting Requirement FAIRMONT PARKWAY 845 / 20 42 B. PARKING LOT TREES: Sec. 106-800 € > Parking lot with minimum 20 spaces shall provide a planter at the ratio of one for every ten parking spaces. Total # of Proposed Parking Spaces # of Spaces Tree Planting Requirement Planters Sq. Ft. Planters Required Total Sq. Ft. 52 52 / 10 6 135 x 6 810 Total # of Proposed Parking Spaces # of Spaces Tree Planting Requirement Total Trees Planted 52 52 / 10 6 6 C. SHRUBS: Sec. 106-800 ( c) >Shrubs are required in the planting strip adjecent to the right-of-way and shall be placed at three feet on center. Equivalent Credits Total Trees Planted CITY OF LA PORTE TREE ORDINANCE LANDSCAPE ANALYSIS FORM NON-SINGLE FAMILY RESIDENTIAL TREE AND SHRUB PLANTING REQUIREMENTS STREET TREES: Sec. 33-126 (a) Length of property in lineal feet as measured along each street separately 0 42 TOTAL STREET TREES 42 > Planters (minimum 135 sq ft) each required planter shall have one shade tree. Trees shall be dispersed throughout the parking lot to maximize shadding BF CONTROLLER: 1 1/2" BACKFLOW PREVENTER HUNTER ACC RAIN SENSOR: 1 1/2" WATER METER C RS 6" 6" 6"6"6"6"6"6" 6" NOTE: COMPONENTS ARE SHOWN FOR DESIGN AND BIDDING PURPOSES. EXACT LOCATION SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. "1 "1 "1211"211""1 211""1"1211"211"211" 211" 43" 43" 211" 43"43" 43" 43"43"43""1 "143" 43"43"43"43"211" 43" 43" 2" 331.7 2" 445.3 2" 38.85 2" 728.9 2" 841.9 2" 45.29 221" 43"43"43"43"43"43" "1"1211" "143""1 "1 2" 34.06 HUNTER SOLAR-SYNC 43"43" 221" "4 "4 "1 "1 211" 211" 211" 43""1 2" 138.2 2" 225.3 43""1 211" 43" "1 211"43" 43" 6"43" 43" "1 211" 43"221" 211" "1 2 "211" 2 " "1 "1 2 " "1 "1 43" 43" 211" 211" 43" 211" 43" 43"43" 43" 211" "1 211"211" "1 "1 43" 43" 43" 43" 43" SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI Hunter PROS-04-CV 5` strip spray Turf Spray, 4.0" Pop-Up. With Drain Check Valve. Co-molded wiper seal with UV Resistant Material. 12 20 Hunter PROS-04-CV ADJ Turf Spray, 4.0" Pop-Up. With Drain Check Valve. Co-molded wiper seal with UV Resistant Material. 109 20 Tree Bubbler Hunter PCN Flood Bubbler (TWO PER TREE) See TREE BUBBLER DETAIL for proper installation. Provide separate zone for all tree bubblers, do not connect to shrub, tree, or sod zones. 68 15 SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI GPM RADIUS Hunter PGP-04-MPR Turf Rotor, 4.0" Pop-Up. Adjustable to Full Circle. MPR Nozzle. 36 25 32' SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY Hunter ICV-G 1", 1-1/2", 2", and 3" Plastic Electric Remote Control Valves, Globe Configuration, with NPT Threaded Inlet/Outlet, for Commercial/Municipal Use. 8 Febco 765 1-1/2" Pressure Vacuum Breaker, brass with ball valve SOV. Install 12" (305MM) above highest downstream outlet and the highest point in the downstream piping. 1 Hunter ACC-1200 12 Station Outdoor Modular Controller. No Module Required. High-End Commercial Use. Metal Cabinet. 1 Hunter WSS Wireless Solar, rain freeze sensor with outdoor interface, connects to Hunter PCC, Pro-C, and I-Core Controllers, install as noted. Includes 10 year lithium battery and rubber module cover, and gutter mount bracket. 1 Water Meter 1-1/2" City Tap 1 Irrigation Lateral Line: PVC Class 200 SDR 21 2,855 l.f. Irrigation Lateral Line: PVC Class 200 SDR 21 1,138 l.f. Irrigation Mainline: CPVC Schedule 40 693.5 l.f. Pipe Sleeve: CPVC Schedule 40 406.1 l.f. BF C RS Hunter PROS-12 5` strip spray Shrub Spray, 12.0" Pop-Up. Co-molded wiper seal with UV Resistant Material. 23 20 IRRIGATION SCHEDULE P.O.C. NUMBER: 01 Water Source Information:City Tap FLOW AVAILABLE Water Meter Size:1-1/2" Flow Available:75.00 gpm PRESSURE AVAILABLE Static Pressure at POC:50.00 psi Elevation Change:5.00 ft Service Line Size:2" Length of Service Line:20.00 ft Pressure Available:47.00 psi DESIGN ANALYSIS Maximum Station Flow:45.29 gpm Flow Available at POC:75.00 gpm Residual Flow Available:29.71 gpm Critical Station:6 Design Pressure:25.00 psi Friction Loss:4.19 psi Fittings Loss:0.42 psi Elevation Loss:0.00 psi Loss through Valve:0.80 psi Pressure Req. at Critical Station: 30.40 psi Loss for Fittings:0.19 psi Loss for Main Line:1.90 psi Loss for POC to Valve Elevation: 0.00 psi Loss for Backflow:2.59 psi Loss for Water Meter:1.69 psi Critical Station Pressure at POC: 36.77 psi Pressure Available:47.00 psi Residual Pressure Available:10.23 psi CRITICAL ANALYSIS VALVE SCHEDULE NUMBER MODEL SIZE TYPE GPM PSI @ POC 1 Hunter ICV-G 2" Turf Rotor 0.00 2 Hunter ICV-G 2" Shrub Spray 25.30 3 Hunter ICV-G 2" Turf Rotor 31.65 36.37 4 Hunter ICV-G 2" Turf Spray 45.29 33.90 5 Hunter ICV-G 2" Turf Spray 38.84 32.24 6 Hunter ICV-G 2" Bubbler 34.00 7 Hunter ICV-G 2" Turf Rotor 28.90 36.77 8 Hunter ICV-G 2" Turf Spray 41.87 35.08 9 Hunter ICV-G 2" Turf Spray 45.17 36.74 WALL MOUNTED CONTROLLER NO SCALE CONTROLLER AS SPECIFIED HARD WIRE 117 VOLT A.C. POWER OUTLET BEHIND CONTROLLER KEYED LOCK OR PAD LOCK PLAN ELEVATION SCHEDULE 80 PVC MALE CONNECTOR 11/4" RIGID STEEL CONDUIT STEEL SPLICE ACCESS PANEL RIGID STEEL CONDUIT- set plumb SCHEDULE 80 PVC COUPLING SCHEDULE 80 PVC SWEEP ELL 6' LONG COPPER GROUND ROD- connect to ground terminal on the controller WALL LAG BOLTS OR EXPANSION BOLTS AS REQUIRED CONTROLLER BOX HARD WIRE 117 VOLT A.C. POWER SUPPLY BEHIND CONTROLLER IN FLUSH BOX 1/2" STEEL CONDUIT 10 5 NO SCALE RAIN SENSOR CONDUIT THROUGH WALL BY ELECTRICAL CONTRACTOR. J-BOX BY ELECTRICALCONTRACTOR PARAPET COPINGPLACE RAIN SENSORJUST BELOW PARAPET COPING. RAIN SENSOR: HUNTERMINI-CLIK-C WITHFEMALE THREADED INLET. ELECTRICAL CONDUIT TO RAIN SENSOR BYIRRIGATION CONTRACTOR. ROOF OF BUILDING CONDUIT W/ PULL WIRE TOCONTROLLER BY ELECTRICAL CONTRACTOR. NO SCALE REMOTE CONTROL VALVE DETAIL PEA GRAVEL REMOTE CONTROL VALVE W/24" LONG LOOP OF CONTROL WIRE 45 DEGREE ELBOW SCHEDULE 40 PVC FITTING MAINLINE VALVE BOX FLUSH WITH FINISH GRADE 7 FINISH GRADE SPECIFIED SPRAY BODY AND NOZZLE CLASS 200 PVC LATERAL LINE HIGH-POP SPRAY HEAD DETAIL NO SCALE PVC SCHEDULE 40 OUTLET TEE OR ELL RAINBIRD SWING ASSEMBLYMODEL SA 127575:1/2" BY 12" LONG ORHUNTER SWING JOINTMODEL SJ-712: 1/2" BY 12" LONG 8 NO SCALE FINISH GRADE CLASS 200 LATERAL LINE GEAR DRIVEN ROTOR HEAD GEAR DRIVEN ROTOR HEAD AS SPECIFIED set top of body flush with finish grade SCH 40 PVC TEE RAINBIRD SWING ASSEMBLYMODEL SA 127057: 3/4" BY 12" LONG ORHUNTER SWING JOINTMODEL SJ-512: 3/4" BY 12" LONG 6 GATE VALVE DETAIL NO SCALE FINISH GRADE 6" PVC PIPE VALVE BOX GATE VALVE - LINE SIZE PEA GRAVEL BRICK (2 TOTAL) PVC MAIN LINE PEA GRAVEL (6" DEPTH) 3 NO SCALE BACKFLOW VALVE COVER2 GUARD SHACK VANDAL &THEFT RESISTANT ENCLOSURE, 'LIFT OFF MODEL' COLOR TOBE GREEN. INSTALL PERMANUFACTURERS SPECS. COMPACTED SUBGRADE CONCRETE PAD,PER MANUFACUTERSSPECS. NO SCALE COPPER NIPPLE COPPER 90 DEGREE ELBOW COPPER NIPPLE COPPER UNION COPPER NIPPLE (LENGTH AS REQUIRED) ADAPT INLET AND OUTLET AS REQUIRED MAINLINE FROM SOURCE12" MINIMUM 30" MAX.BACKFLOW PREVENTOR NOTE: WRAP ALL ABOVE GROUND COMPONENTS WITH INSULATION FORFREEZE PROTECTION ORINSTALL INSULATED FIBERGLASS ENCLOSURE. 1 WYE STRAINER VALVE BOX FLUSH WITH FINISH GRADE PVC MAIN LINE SCH 40 PVC TEE SCH 80 ELL QUICK COUPLING VALVE DETAIL NO SCALE 1/2" x 24" STEEL STAKE 3/4" x 12" GALVANIZED STEEL NIPPLE QUICK COUPLING VALVE 3/4" x 3" SCH 80 NIPPLE 4 FINISH GRADE 9 FINISH GRADE ROOT BALL 4" DIA. PVC INSPECTION TUBE - see tree planting detail BUBBLER HEAD - Place bubbler head on top of rootball, two bubblers per tree SCH 40 PVC NIPPLE SCH 40 PVC TEE OR ELL PVC LATERAL LNE BUBBLER DETAIL NO SCALE 1/2" FLEX PVC ENGINEER'S CERTIFICATIONFLOOD PLAIN STATUSFLOOD CONTROL DISTRICT CRITERIADESCRIPTION OF PROPERTYHCED SIGNATURE BLOCK COMMERCIAL / OTHER SITE DRAINAGEWATER AND WASTEWATERHARRIS COUNTYENGINEERING DEPARTMENTREVIEW SHEETHARRIS COUNTY FLOOD CONTROL DISTRICTENGINEERING DIVISIONPAVINGDRIVEWAYS (in H.C. ROW only)TRAFFIC CONSIDERATIONS RESIDENTIAL / SUBDIVISION DRAINAGE1.3.4.5.2.7.8. CURBING FIRE APPARATUS ACCESS ROADCURB RAMPS 11.****(2001 ADJ.)6.STORMWATER QUALITY WORK IN HCFCD RIGHT-OF-WAY9.LANDSCAPING 12.PERMITS REQUIRED10. WORK IN HARRIS COUNTY R.O.W.IF YES, CHECK THE BOX THAT APPLIES TO THIS PROJECTTO BE FILLED OUT BY HARRIS COUNTYNOTE: ALL EXISTING AND PROPOSED UTILITIES MUST BEACCURATELY SHOWN & LABELED ON THE SITE PLANS.NOTE: SEPTIC SYSTEMS REQUIRE H.C. WASTE WATER REVIEWNOTE: PUBLIC UTILITIES REQUIRE A LETTER FROM THE DISTRICT/MUNICIPALITY AUTHORIZING SERVICE & CONNECTION.THIS IS REQUIRED FOR PLAN APPROVAL.NOTE: ALL ROADSIDE DITCH OUTFALLS REQUIRE EROSION CONTROL MEASURES.RIPRAP IS NOT ALLOWED AS AN EROSION CONTROL MEASURE IN HARRIS COUNTY ROW.ALL PUMPED DETENTION OUTFALLS TO ROADSIDE DITCHES REQUIRE MANHOLE W/ LEADS.DOES THE PROPERTY HAVE ANY VIOLATIONS? IF SO PLEASE PROVIDEALL VIOLATION NUMBERS.DESIGNTHICKNESSOF PAVINGSTABILIZEDSUBGRADEDEPTHDESIGNSTRENGTHOF CONCRETESTEEL SPACINGLONG. TRANS.(IN.)(IN.)(PSI)(IN.) (IN.)NOTE: ALL APPROVED, FINAL PLATS AND ASSOCIATEDCPC101 FORMS MUST BE INCLUDED WITH PLAN SUBMITTAL.OFFSITE SHEET FLOW: (100 YEAR)OFFSITE SHEET FLOW MAPPING, TOTAL DISCHARGE CALCULATIONS, ANDDESIGN ACCOMODATIONS ARE SHOWN ON SHEET _____ OR, AS PRESENTEDIN THE APPROVED DRAINAGE STUDY ENTITLED _________________________.TOTAL ACREAGE = _____TOTAL DISCHARGE = _____NOTE: ALL OFFSITE SHEET FLOW FROM ADJACENT PROPERTIES MUST BEIDENTIFIED AND PROPERLY ACCOUNTED FOR IN THE PROJECT. THE SIGNINGENGINEER HEREBY CERTIFIES THAT THESE AREAS HAVE BEEN ADDRESSED.NOTE: A COPY OF TCEQ APPROVAL FOR PRIVATE WATER &WASTE WATER SYSTEMS IS REQUIRED FOR PLAN APPROVAL.BENCHMARK REQUIREMENTS FORPROPOSED BRIDGES AND OR NEW RESIDENTIAL SUBIDIVSIONSWhen the County Engineer has determined that a new benchmark will be required to be established forthe proposed project, the developer shall be required to install a benchmark per section 8.0, part 2 of theHarris County Infrastructure Regulations.Is a new Benchmark required for this project? (to be determined by Harris County) [__] yes [__] noIf a new Benchmark is required, the proposed benchmark information is shown on sheets ____NOTE: DEDICATED UNDERGROUND FIRE LINES MUST BE SUBMITTED TOTHE HARRIS COUNTY FIRE PROTECTION GROUP FOR REVIEW ANDPERMITTING BY THE UNDERGROUND FIRE LINE CONTRACTOR. CIVILREIVEW DOES NOT REVIEW OR APPROVE UNDERGROUND FIRE LINES FORTHE FIRE PROTECTION SYSTEMS.(#4 MIN.)REINFORCESTEELSIZE ³ ³ ³ Ɵon that is privileged and confidenƟal ELEVATION SOUTH NORTH EAST WEST TOTAL SF PERCENT OF BRICK PROVIDED PERCENT OF BRICK REQUIRED Ɵon that is privileged and confidenƟal EXTERIOR MATERIALS SCHEDULE CODE MATERIAL MANUFACTURER DESCRIPTION COLOR REMARKS Ɵon that is privileged and confidenƟal EXTERIOR MATERIALS SCHEDULE CODE MATERIAL MANUFACTURER DESCRIPTION COLOR REMARKS Ɵon that is privileged and confidenƟal EXTERIOR MATERIALS SCHEDULE CODE MATERIAL MANUFACTURER DESCRIPTION COLOR REMARKS