HomeMy WebLinkAboutFIVE POINTS PLAZA EXPANSION SITE PLAN (2020)ENGINEER'S CERTIFICATION FLOOD PLAIN STATUS DESCRIPTION OF PROPERTY COMMERCIAL / OTHER SITE DRAINAGE WATER AND WASTEWATER HARRIS COUNTY ENGINEERING DEPARTMENT REVIEW SHEET PAVING DRIVEWAYS (in H.C. ROW only) TRAFFIC CONSIDERATIONS RESIDENTIAL / SUBDIVISION DRAINAGE1.3.4. 5. 2. 7. CURBING FIRE APPARATUS ACCESS ROAD CURB RAMPS 8. * **** (2001 ADJ.) 6.STORMWATER QUALITY LANDSCAPING 9. PERMITS REQUIRED10. WORK IN HARRIS COUNTY R.O.W. FOR PROJECTS LOCATED IN ANY FLOODPLAIN Development constructed or placed in accordance with these plans will comply with all provisions of the Regulations of Harris County, Texas for Floodplain Management. No net fill is allowed in the flood plain and no fill is allowed in the floodway. FOUNDATION NOTES: (Applies to only buildings or building additions requiring a class II permit) All water heaters, furnaces, air conditioning units, electrical distribution panels, and any other mechanical or electrical equipment must be elevated in accordance with Section 4.05 of Harris County Floodplain regulations. Any electrical circuit serving a light switch or outlet located below the base (100-year) flood elevation shall be dropped from above and be on a separate breaker. All materials used below the (100-year) base flood elevation are on approved FEMA Technical Bulletin 2-08 as Class 5 water-resistant, and approved in accordance with FEMA Technical Bulletin 1-08 for foundation openings. Critical facilities located in the 0.2% or 500yr floodplain or 1% or 100yr floodplain shall have the lowest floor elevated to 3 feet or more above the 0.2% flood elevation, or 24 inches above the crown of the adjacent road, which ever results in a higher elevation. Floodproofing and sealing measures must be taken to ensure that toxic substances will not be displaced by or released into floodwaters. Access routes elevated to or above the level of the base flood shall be provided to all critical facilities to the extent possible. A completed as-built certificate must be submitted after the structure is complete and before it is occupied. The County Engineer's Office will post a final inspection notice on the structure once all requirements have been met. No fill may be used to elevate structures in the 1% or 100yr flood plain. Structures may be constructed on an open foundation, such as piers, or on continuous foundation walls with properly sized and located openings. All foundations are required to be designed by a registered professional engineer. All structures shall be designed to withstand a three second gust basic wind speed of 120mph. Completed *Elevation Certificates to be submitted: one at permitting, a second after the slab is poured or sub-floor is installed and before the framing starts, and a third is required once construction is finished. *(PER CURRENT FIRM PANEL) to the Harris County Engineering Department, 10555 Northwest Freeway, Suite 120, Houston, TX 77092 IF YES, CHECK THE BOX THAT APPLIES TO THIS PROJECT NOTE: ALL EXISTING AND PROPOSED UTILITIES MUST BE ACCURATELY SHOWN & LABELED ON THE SITE PLANS. NOTE: SEPTIC SYSTEMS REQUIRE H.C. WASTE WATER REVIEW NOTE: PUBLIC UTILITIES REQUIRE A LETTER FROM THE DISTRICT/ MUNICIPALITY AUTHORIZING SERVICE & CONNECTION. THIS IS REQUIRED FOR PLAN APPROVAL. NOTE: ALL ROADSIDE DITCH OUTFALLS REQUIRE EROSION CONTROL MEASURES. RIPRAP IS NOT ALLOWED AS AN EROSION CONTROL MEASURE IN HARRIS COUNTY ROW. ALL PUMPED DETENTION OUTFALLS TO ROADSIDE DITCHES REQUIRE MANHOLE W/ LEADS. DOES THE PROPERTY HAVE ANY VIOLATIONS? IF SO PLEASE PROVIDE ALL VIOLATION NUMBERS. DESIGN THICKNESS OF PAVING STABILIZED SUBGRADE DEPTH DESIGN STRENGTH OF CONCRETE STEEL SPACING LONG.TRANS. (IN.)(IN.)(PSI)(IN.)(IN.) NOTE: ALL APPROVED, FINAL PLATS AND ASSOCIATED CPC101 FORMS MUST BE INCLUDED WITH PLAN SUBMITTAL. OFFSITE SHEET FLOW: (100 YEAR) OFFSITE SHEET FLOW MAPPING, TOTAL DISCHARGE CALCULATIONS, AND DESIGN ACCOMODATIONS ARE SHOWN ON SHEET _____ OR, AS PRESENTED IN THE APPROVED DRAINAGE STUDY ENTITLED _________________________. TOTAL ACREAGE = _____ TOTAL DISCHARGE = _____ NOTE: ALL OFFSITE SHEET FLOW FROM ADJACENT PROPERTIES MUST BE IDENTIFIED AND PROPERLY ACCOUNTED FOR IN THE PROJECT. THE SIGNING ENGINEER HEREBY CERTIFIES THAT THESE AREAS HAVE BEEN ADDRESSED. NOTE: A COPY OF TCEQ APPROVAL FOR PRIVATE WATER & WASTE WATER SYSTEMS IS REQUIRED FOR PLAN APPROVAL. BENCHMARK REQUIREMENTS FOR PROPOSED BRIDGES AND OR NEW RESIDENTIAL SUBIDIVSIONS When the County Engineer has determined that a new benchmark will be required to be established for the proposed project, the developer shall be required to install a benchmark per section 8.0, part 2 of the Harris County Infrastructure Regulations. Is a new Benchmark required for this project? (to be determined by Harris County) [__] yes [__] no If a new Benchmark is required, the proposed benchmark information is shown on sheets ____ NOTE: DEDICATED UNDERGROUND FIRE LINES MUST BE SUBMITTED TO THE HARRIS COUNTY FIRE PROTECTION GROUP FOR REVIEW AND PERMITTING BY THE UNDERGROUND FIRE LINE CONTRACTOR. CIVIL REIVEW DOES NOT REVIEW OR APPROVE UNDERGROUND FIRE LINES FOR THE FIRE PROTECTION SYSTEMS. (#4 MIN.) REINFORCE STEEL SIZE WASTEWATER TREATMENT PLANTS IS THE PROPOSED PROJECT A NEW WWTP SITE OR A REHAB/EXPANSION OF AN EXISTING WWTP SITE?YES NO IF YES, IS A HARRIS COUNTY DOMESTIC WASTEWATER TREATMENT PLANT EXPRES REVIEW SHEET ATTACHED AND COMPLETED ACCORDING TO INSTRUCTIONS? YES NO REFER TO: WWW.ENG.HCTX.NET/PERMITS/WASTEWATER/REGULATIONS-STANDARDS-DETAILS FOR DOMESTIC WWTP ERS FORM HARRIS COUNTY ENGINEERING DEPARTMENT - PERMIT OFFICE NOTE: THE PERMIT MANAGER SIGNATURE REPRESENTS THE FOLLOWING: ·THE COMPLETION OF REVIEW OF THESE PLANS ·INTERPOSE NO OBJECTION TO THE PROPOSED DESIGN ON PRIVATE PROPERTY ·APPROVAL OF WORK IN HARRIS COUNTY MAINTAINED RIGHT OF WAY ·APPROVAL OF WORK IN PROPOSED HARRIS COUNTY RIGHT OF WAY THAT IS TO BE ACCEPTED BY THE COUNTY LICENS E DPRO F ESSIONA L E N G INEERSTA T E OF TEX ASHuitt-Zollars Inc. Firm Registration No. F-761 CRAIG A. HAJOVSKY 115699 TG=17.59' TYPE 'A' INLETTYPE 'A' INLET TG=17.63' TYPE 'A' INLET TG=17.55' FL 18"(SW)=-1.95 TYPE 'A' INLET TG=17.75' FL 18"(NE)=-1.81 FL 18"(SW)=-1.81 TYPE 'A' INLET TG=19.39' FL 36"(NW)=13.67 FL 36"(SE)=13.67 TYPE 'A' INLET TG=19.33' FL 36"(NW)=13.61 FL 36"(SE)=13.44 TYPE 'A' INLET TG=19.67' FL 36"(NW)=13.70 FL 36"(SE)=13.64 TYPE 'A' INLET TG=17.69' FL 18"(NE)=-1.99 TYPE 'A' INLET TG=17.60' FL 18"(NE)=-1.96 FL 18"(SW)=-1.96 STM MH RIM=20.22' FL 36"(SE)=13.72' FL 24"(NW)=13.78' FL 24"(NW)=13.87' SAN MH RIM=18.23' FL 8"(SW)=7.79' FL 8"(NW)=7.33' FL 8"(NE)=8.99' EXIST LPAWA WATERLINE 26.5' 36.9' 23.2' 33.8' 23.2' EXIST ASPHALT EXIST CONCRETE APPROX. CONC. TO ASPHALT TRANSITION APPROX. GUTTER LINE 22.4' EAST MAIN STREET (100' R.O.W)S BROADWAY STREET(100' R.O.W)APROX R.O.W.S VIRGINIA STREET280.9' FROM FIRE HYDRANT 282.9' FROM FIRE HYDRANT CADFILE: \\hzhouston\projects\r311838.01 - five points plaza-design-bidding-ca\10 cadd & bim\10.1 autocad\sheet files\C-104 OVERALL SITE PLAN.dwg Plotted: Fri. Jul. 10, 2020 @ 2:54 PM By: edayatoOF DESIGNED BY: CHECKED BY:PROJECT NO: DRAWN BY:SURVEYED BY: R311838.01 REV DATE DRAWING SCALE SHEET NUMBER OWNER/CLIENT: SHEET TITLE: N/A CAD DWG FILE: C-104 OVERALL SITE PLAN.dwg HA HA CH CITY OF LA PORTE 5 POINTS PLAZA PROJECT 102 E MAIN STREET LA PORTE, TX 77571 (281) 470-7275 AS NOTED Huitt-Zollars, Inc. TPBE Reg. No. F-761 10350 Richmond Ave., Suite 300 Houston, Texas 77042-4248 Phone (281) 496-0066 Fax (281) 496-0220 L ICEN S E DPRO F ESSIONA L E N G INEERSTA T E O F TEX ASHuitt-Zollars Inc. Firm Registration No. F-761 CRAIG A. HAJOVSKY 115699 49 1 ISSUE FOR BID 07/10/2020 OVERALL SITE PLAN C-104 1 OVERALL SITE PLAN NPROPOSED PAVILION NOTE 1.SANITARY AND WATER TAPS TO BE INSPECTED BY THE CITY OF LA PORTE ACCEPTANCE. 2.CITY OF LA PORTE (COLP) STAFF WILL INSTALL THE WATER METER FOR SIZES 2” AND UNDER. CONTRACTOR TO MAKE WATER TAP. PLEASE COORDINATE WITH COLP STAFF. PROPOSED RESTROOM F.F. ELEVATION = 20.63' 163.0' 100.0' 102.3' 25.0' 51.2' 72.0' 25.0' 7.2' 5.9' PROP STM SWR MANHOLE (TIE INTO EXIST STM SWR SYSTEM) 19.0' 19.0' 49.9' 24.0' 24.5' 5.5' 9.5' 18.5' 10.0' 9.0' (TYP.) 11.0' 5.0' 57.0' 7.3' 9.0' (TYP.) 9.5'9.5'25.1' 13.5' 19.5' 44.6'PROP 5' SIDEWALKPROP 4 ADA ACCESSIBLE SPACES PROP ADA ACCESSIBLE ISLE (TYP.) 5.5' PROP GRATE INLET PROP GRATE INLET PROP GRATE INLET PROP GRATE INLET PROP GRATE INLET PROP STM SWR MANHOLE PROP PAVILION COLUMN (TYP.) (BY OTHERS) PROP LED LIGHT FIXTURES. REF E-101 4" WHITE STRIPE (TYP) 4" TRAFFIC YELLOW STRIPE SPACED DIAGONALLY 45° TWO FEET PARALLEL (TYP) PROP STM SWR MANHOLE PROP 5' SIDEWALK FUTURE SIDEWALK (BY OTHERS) 7.1' PROP STAIRS PROP WHEELCHAIR RAMP REF A-101 13.4' 9.5' 37.0' 18.1' 140' 38.5' R12.0'R12.0' R12.0' R12.0' R15.0' R7.0' (TYP.)R3.4' (TYP.) PROP WHEELSTOP (TYP.) PROP 72 LF ZURN Z886 CLASS A (HPP) TRENCH DRAIN OR APPROVED EQUAL SEE DETAIL SHEET C-116 21.0' 9.0' (TYP.) 35.0' 29.9' R15.0' PROP DRIVEWAY FLOODPLAIN STATEMENT: ACCORDING TO THE FEDERAL EMERGENCY MANAGEMENT AGENCY (FEMA) FLOOD INSURANCE RATE MAP (FIRM) FOR HARRIS COUNTY, TEXAS MAP NO. 48201C0945M REVISED JANUARY 6, 2017, THE SUBJECT TRACT APPEARS TO BE OUT OF THE 100-YEAR FLOODPLAIN AND PARTIALLY WITHIN SHADED ZONE "X" DEFINED AS AREA OF AN 0.2% ANNUAL CHANGED FLOOD. 24' E.E. 24.0' F.F. 266.0' 125.0' 9.0' F.F. 9.0' 9.0' 5.0' EXIST SIGN AND FOUNTAIN PROP. 2" WATER LINE PROP. 4" SANITARY SEWER R15.0' PROP. RAMPS 16.0'' ALLEY PROP. 12" STM SWR EXIST STM CULVERT AND DRIVEWAY R15.0' PROJECT BENCHMARK: BM #1 NGS BENCHMARK J1006; ALUMINUM DISK SET IN CONCRETE NEAR THE SOUTHEAST CORNER OF THE INTERSECTION OF E. MAIN ST. & S. BROADWAY ST., ±6.5' SOUTHEAST OF A LIGHT POST, ±15' NORTHEAST OF AN ELECTRIC PULLBOX AND ±16.6' NORTHWEST OF A BOLLARD. TEMPORARY BENCHMARKS ARE AS FOLLOWS: TBM #1 5/8-INCH IRON ROD WITH RED PLASTIC CAP SET ON THE EAST SIDE OF S. BROADWAY ST., APPROXIMATELY 165' SOUTHEAST OF THE SOUTHEAST CORNER OF THE INTERSECTION OF E. MAIN ST. & S. BROADWAY ST., ±22.4' SOUTHEAST OF THE SOUTHWEST CORNER OF A RECTANGULAR FOUNTAIN, ±20.8' SOUTHEAST OF A LIGHT POST AND ±26.6' SOUTHWEST OF A STORM INLET. TBM #2 5/8-INCH IRON ROD WITH RED PLASTIC CAP SET ON THE NORTH SIDE OF E. MAIN ST., APPROXIMATELY 261' NORTHEAST OF THE NORTHEAST CORNER OF THE INTERSECTION OF E. MAIN ST. & S. BROADWAY ST. AND ±12.4' NORTHWEST OF THE EDGE OF ASPHALT PAVING AT THE NORTHWEST CORNER OF THE INTERSECTION OF E. MAIN ST. AND N. VIRGINIA AVE. R15.0' EXIST LIGHT POLES 7.8' 20.9' 9 10.0' PROP RAMP 7.0' N PROJECT LOCATION CITY NOTES: LIGHTING AND GLARE. ANY LIGHTING USED SHALL BE ARRANGED SO AS TO DEFLECT LIGHT FROM ANY ADJOINING RESIDENTIAL ZONE OR FROM PUBLIC STREETS. DIRECT OR SKY-REFLECTED GLARE, WHERE FROM FLOODLIGHTS OR FROM HIGH TEMPERATURE PROCESSES SUCH SUCH AS COMBUSTION OR WELDING SHALL NOT BE DIRECTED ONTO ANY ADJOINING PROPERTY. THE SOURCE OF LIGHTS SHALL BE HOODED OR CONTROLLED IN SOME MANNER SO AS NOT TO LIGHT ADJACENT PROPERTY. BARE INCANDESCENT LIGHT BULBS SHALL NOT BE PERMITTED IN VIEW OF ADJACENT PROPERTY OR PUBLIC RIGHT-OF-WAY. ANY LIGHT OR COMBINATION OF LIGHTS WHICH CAST LIGHT ON A PUBLIC STREET SHALL NOT EXCEED ONE FOOTCANDLE (METER READING) AS MEASURED FROM THE CENTERLINE OF SUCH STREET. ANY LIGHT OR COMBINATION OF LIGHTS WHICH CAST LIGHT ON RESIDENTIAL PROPERTY SHALL NOT EXCEED 0.4 FOOTCANDLES (METER READING) AS MEASURED FROM SUCH PROPERTY. RADIATION AND ELECTRICAL EMISSIONS. NO ACTIVITIES SHALL BE PERMITTED THAT EMIT DANGEROUS RADIOACTIVITY BEYOND ENCLOSED AREAS. THERE SHALL BE NO ELECTRICAL DISTURBANCE ADVERSELY AFFECTING THE OPERATION AT ANY POINT OF ANY EQUIPMENT OTHER THAN THAT OF THE CREATOR OS SUCH DISTURBANCE. SMOKE. THE EMISSION OF SMOKE BY ANY USE SHALL BE IN COMPLIANCE WITH AND REGULATED BY THE APPROPRIATE FEDERAL, STATE OR LOCAL AGENCY. DUST OR OTHER PARTICULATE MATTER. THE EMISSION OF DUST, FLY ASH OR OTHER PARTICULATE MATTER BY ANY USE SHALL BE IN COMPLIANCE WITH AND REGULATED BY THE APPROPRIATE FEDERAL, STATE OR LOCAL AGENCY. ODORS. THE EMISSION OF ODOR BY ANY USE SHALL BE IN COMPLIANCE WITH AN REGULATED BY THE APPROPRIATE FEDERAL, STATE OR LOCAL AGENCY. EXPLOSIVES. NO ACTIVITIES INVOLVING THE STORAGE, UTILIZATION, OR MANUFACTURE OF MATERIALS OR PRODUCTS SUCH AS TNT OR DYNAMITE WHICH COULD DECOMPOSE BY DETONATION SHALL BE PERMITTED EXCEPT SUCH AS ARE SPECIFICALLY LICENSED BY THE CITY COUNCIL. NOISE. ALL NOISE SHALL BE MUFFLED SO AS NOT TO BE OBJECTIONABLE DUE TO INTERMITTENCE, BEAT FREQUENCY OR SHRILLNESS AND AS MEASURED AT ANY PROPERTY LINE IN ACCORDANCE WITH THE DECIBEL LEVELS OUTLINED IN SECTION 106-310 OF THE CITY CODE OF ORDINANCES. CITY APPROVING AUTHORITY CERTIFICATE: THIS IS TO CERTIFY THAT ON __ DAY OF _________________________ ,20 _____ THE CITY OF LA PORTE, TEXAS, HAS APPROVED THIS SITE PLAN AND DEVELOPMENT OF _5 POINTS PLAZA_ IN ACCORDANCE WITH THE ORDINANCES OF THE CITY OF LA PORTE. BY: ___________________________________________ DIRECTOR, PLANNING AND DEVELOPMENT ___________________________________________ CITY PLANNER ___________________________________________ CITY ENGINEER 2" PVC UNDERGROUND CONDUIT REF E-100 APPROX. LOCATION OF EXIST. FIRE HYDRANT ALL DIMENSIONS ARE FROM BACK OF CURB, UNLESS NOTED OTHERWISE PROP. 6" CURB R15.0' 3.1% SLOPE PROP ASPHALT DRIVEWAY 3.3% SLOPE 2" WATER METER 2" REDUCED PRESSURE ZONE BACKFLOW PREVENTER 27.0' PROP. SANITARY CLEANOUTS REF C-107 THIS PROJECT IS LOCATED IN THE MAIN STREET OVERLAY. PER THE CITY OF LA PORTE, TX CODE OF ORDINANCES SECTION 106-240 PASSED AND APPROVED ON NOVEMBER 10, 2014, PROJECTS IN THE MAIN STREET OVERLAY HAVE EXCEPTIONS TO THE MINIMUM BUILDING SETBACKS. PROP CONC. PROP ASPHALT 4.3% SLOPE 1.0% SLOPE 0.3% SLOPE July10th 20 TG=17.59' TYPE 'A' INLETTYPE 'A' INLET TG=17.63' TYPE 'A' INLET TG=17.55' FL 18"(SW)=-1.95 TYPE 'A' INLET TG=17.75' FL 18"(NE)=-1.81 FL 18"(SW)=-1.81 TYPE 'A' INLET TG=19.67' FL 36"(NW)=13.70 FL 36"(SE)=13.64 TYPE 'A' INLET TG=17.69' FL 18"(NE)=-1.99 TYPE 'A' INLET TG=17.60' FL 18"(NE)=-1.96 FL 18"(SW)=-1.96 STM MH RIM=20.22' FL 36"(SE)=13.72' FL 24"(NW)=13.78' FL 24"(NW)=13.87' EXIST LPAWA WATERLINE 26.5' 36.9' 23.2' 33.8' 23.2' EXIST ASPHALT EXIST CONCRETE APPROX. GUTTER LINE 22.4' EAST MAIN STREET (100' R.O.W)S BROADWAY STREET(100' R.O.W)S VIRGINIA STREETPROP STM SWR MANHOLE (MH1) RIM = 18.95 8" FL = 16.20 (E) 6" FL = 16.40 (S) 18" FL = 14.40 (NE) 18" FL = 14.40 (SW)CADFILE: \\hzhouston\projects\r311838.01 - five points plaza-design-bidding-ca\10 cadd & bim\10.1 autocad\sheet files\C-105 STORM SEWER AND DRAINAGE PLAN.dwg Plotted: Fri. Jul. 10, 2020 @ 2:41 PM By: edayatoOF DESIGNED BY: CHECKED BY:PROJECT NO: DRAWN BY:SURVEYED BY: R311838.01 REV DATE DRAWING SCALE SHEET NUMBER OWNER/CLIENT: SHEET TITLE: N/A CAD DWG FILE: C-105 STORM SEWER AND DRAINAGE PLAN.dwg 1 HA HA CH CITY OF LA PORTE 5 POINTS PLAZA PROJECT 102 E MAIN STREET LA PORTE, TX 77571 (281) 470-7275 AS NOTED Huitt-Zollars, Inc. TPBE Reg. No. F-761 10350 Richmond Ave., Suite 300 Houston, Texas 77042-4248 Phone (281) 496-0066 Fax (281) 496-0220 L ICEN S E DPRO F ESSIONA L E N G INEERSTA T E O F TEX A SHuitt-Zollars Inc. Firm Registration No. F-761 CRAIG A. HAJOVSKY 115699 49 1 ISSUE FOR BID 07/10/2020 C-105 1 STORM SEWER AND DRAINAGE PLAN NPROP TYPE "A" INLET (DA1) TG = 18.0 12" FL = 15.50 (NW) 104 LF 8" HDPE STM SWR LINE @ 1% MIN SLOPE 52 LF 18" HDPE STM SWR LINE @ 0.43% 61 LF 12" HDPE STM SWR LINE @ 0.59% 92 LF 12" HDPE STM SWR LINE @ 0.38% 63 LF 12" HDPE STM SWR LINE @ 0.40% 61 LF 12" HDPE STM SWR LINE @ 0.41% PROP TYPE "A" INLET (DA4) TG = 18.0 12" FL = 15.25 (SE) 12" FL = 15.25 (SW) PROP TYPE "A" INLET (DA5) TG = 18.0 12" FL = 14.90 (NE) 12" FL = 14.90 (SW) 15" FL = 14.90 (S) PROP TYPE "A" INLET (DA2) TG = 18.0 12" FL = 15.15 (W) PROP TYPE "A" INLET (DA6) TG = 18.2 15" FL = 14.74 (NE) 12" FL = 14.74 (SE) 18" FL = 14.74 (W) PROP TYPE "A" INLET (DA3) TG =18.0 12" FL = 15.10 (NW) PROP STM SWR MANHOLE (MH2) TIE-IN TO EXIST 24" STM SWR RIM = MATCH EXIST GRADE PROP 18" FL = 14.10 (NE) EXIST 24" FL = 13.87 (N) EXIST 24" FL = 13.87 (S) STORM SEWER AND DRAINAGE PLAN PROPOSED RESTROOM F.F. ELEVATION = 20.63' PROPOSED PAVILION DA 7 0.13 0.55 DA 6 0.11 0.47 DA 5 0.11 0.45 DA 4 0.08 0.34 DA 3 0.10 0.43 DA 2 0.13 0.53 DA 1 0.10 0.41 48 LF 18" HDPE STM SWR LINE @ 0.63% PROP STM SWR MANHOLE RIM = 18.95 18" FL = 14.62 (E) 18" FL = 14.62 (SW) 30 LF 6" HDPE STM SWR LINE @ 3% MIN SLOPE CONNECT TO ZURN Z886 TRENCH DRAIN PROP 72 LF ZURN Z886 CLASS A (HPP) TRENCH DRAIN OR APPROVED EQUAL SEE DETAIL SHEET C-116 SEE MEP FOR CONTINUATION REF P-101 37 LF 12" RCP STM SWR LINE @ 0.5% FL = 16.2 FL = 16.4 STORM SEWER CALCULATION SUMMARY (5-YR STORM) STORM SEWER CALCULATION SUMMARY (100-YR STORM) 28 LF 18" HDPE STM SWR LINE @ 0.43% SEE MEP FOR CONTINUATION REF P-101 PROP. PAVILION COLUMN REF S-101 10 APPROX CONC. TO ASPHALT TRANSITION 51 LF 15" HDPE STM SWR LINE @ 0.31% NOTE 1.CITY OF LA PORTE (COLP) STAFF WILL INSTALL THE WATER METER FOR SIZES 2” AND UNDER. CONTRACTOR TO MAKE WATER TAP. PLEASE COORDINATE WITH COLP STAFF. 4.3% SLOPE 1.0% SLOPE 0.3% SLOPE