HomeMy WebLinkAbout100 W MAIN (CHAMBER BUILDING) SITE PLANJ
0
J
r
Abbreviations/Legend:
A.F.F.
ABOVE FINISH FLOOR
F.F.
FINISH FLOOR
PROP.
PROPOSED
RE:
REFERENCE
TYP.
TYPICAL
U.N.
UNLESS NOTED
E./E.T.R.
EXISTING
N.
NEW
R.
REPLACE EXIST.
D.
DEMOLITION (REMOVE EXIST,)
BUILDING LINE
CONC, PAVING
(PROP.)
SOD, LANDSCAPE/GRASS
(PROP.)
SOD, LANDSCAPE/GRASS
(EXIST.)
--------------->----
6" H.D.P.F.
srNMNf�s^r
6' METAL FENCE
6' WOOD FENCE
- f 1
OVERHEAD POWER LINE
- - --
PROPERTY LINE
S.S. (PRIVATE)
SANITARY SEWFR LINE
' - ' - ' - - - -
(PRIVATELY OWNED)
S.S. (CITY)
- - -
SANITARY SEWER MAIN LINE
- - - - - - - - _
(CITY OWNED)
S.D.
M■■■■■■■■W
STORM DRAIN LINE
W.L. (PRIVATE)
WATERLINE
(PRIVATELY OWNED)
W.L. (CITY)
WATER MAIN LINE
(CITY OWNED)
SET IRON ROD
0
Opp
ELEVATION - EXISTING
-I- 00.00
ELEVATION - PROPOSED
4-F.IT.
FIRE HYDRANT
C
GUY WIRE
GRADING SLOPE LINE
M.C.
METER CAN
O M.H•
S.S. MANHOLE COVER
P.O.A.
POINT OF ATTACHMENT
0 P.P.
POWER POLE
T.C.
TOP OF CURB
GM
GAS METER
Key Map:
W POLX ST.
PROJECT
LOCATION - --_ 4r
0
a-
M
cn z
W MAIN ST,
Performance Standards:
LIGH71NG & GLARE; ANY LIGHTING USED SHALL BE ARRANGED 50 AS
TO DEFLECT LIGHT AWAY FROM ANY ADJOINING RESIDENTIAL ZONE OR
FROM PUBLIC STREETS, DIRECT OR SKY -REFLECTED GLARE, WHERE
FROM FLOODLIGHTS OR FROM HIGH TEMPERATURE PROCESSES SUCH
AS COMBUSTION OR WELDING SHALL NOT BE DIRECTED ONTO ANY
ADJCINING PROPERTY. THE SOURCE OF LIGHTS SHALL BE HOODED OR
CONTROLLED IN SOME MANNER SO AS NOT TO LIGHT ADJACENT'
PROPERTY. BARE INCANDESCENT LIGHT BULBS SHALL NOT BE
PERMITTED IN VIEW OF ADJACENT PROPERTY OR PUBLIC
RIGHT-OF-WAY. ANY LIGHT OR COMBINATION OF LIGHTS WHICH CAST
LIGHT ON A PUBLIC STREET SHALL NOT EXCEED ONE FOOTCANDLE
(METER READING) AS MEASURED FROM THE CENTERLINL OF SUCHH
STREET. ANY LIGHT OR COMRENATION OF LIGHTS WHICH CASTS LIGHT
ON RESIDENTIAL PROPERTY SHALL NOT EXCEED 0.4 FOOTCANDLES
(METER READING) AS MEASURED FROM SUCH PROPERTY, I
RADIATION AND ELECTRICAL EMISSIONS: NO ACTIVITIES SHALL BE
PERMITTED THAT EMIT DANGEROUS RADIOACTIVITY BEYOND ENCLOSED
AREAS. THERE SHALL BE NO ELECTRICAL DISTURBANCE ADVERSELY
AFFECTING THE OPERATION AT ANY POINT OF ANY EQUIPMENT OR
OTHER THAN THAT OF THE CREATOR OF SUCH DISTURBANCE.
DUST OR PARTICULATE MATTER: THE EMISSION OF DUST, FLY, ASH,
OR OTHER PARTICULATE MATTER BY ANY USE SHALL BE IN
COMPLIANCE WITH AND REGULATED BY THE APPROPRIATE FEDERAL,
STATE, OR LOCAL AGENCY.
ODORS: THE EMISSION OF ODOR BY ANY USE SHALL BE IN
COMPLIANCE WITH AND REGULATED BY THE APPROPRIATE FEDERAL,
STATE, OR LOCAL AGENCY.
EXPLOSIVES: NO ACTIVITIES INVOLVING THE STORAGE, UTILIZATION, OR
MANUFACTURE OF MATERIALS OR PRODUCTS SUCH AS TNT OR
DYNAMITE WHICH COULD DECOMPOSE BY DETONATION SHALL BL
PERMITTED EXCEPT SUCH AS ARE SPECIFICALLY LICENSED BY THE CITY
COUNCIL,
NOISE: ALL NOISE SHALL BE MUFFLED SO AS NOT TO BE
OBJECTIONABLE DUE TO INTERMITTENCE, BEAT FREQUENCY, OR
SHRILLNESS AND AS MEASURED AT ANY PROPERTY LINE IN
ACCORDANCE WITH THE DECIBEL LEVELS OUTLINED IN SECTION
106-310 OF THE CITY CODE OF ORDINANCES.
Texas Accessibilitv Guidelines:
Landscape Chart:
(PER THE CITY OF LA PORTE - CODE OF ORDINANCES)
Occupancy Calculations:
OCCUPANCY TYPE: MIXED USE OCCUPANCY
(PER SECTION 508) GROUP B = BUSINESS (4,151 SF.)
GROUP R-3 = RESIDENTIAL (3,070 SF.)
OCCUPANT LOAD: GROUP B = 1 CO SF./OCCUPNAT
(PER SEC, 1004.1) 4,151 SF./100 SF. = 42
GROUP R-3 = 200 SF./OCCUPANT
3,070 SF./200 SF. = 16
TOTAL~ OCCUPANT LOAD: 58 PERSONS
Site Giadinii Notes:
1. LOT SHALL BE GRADED TO PROVIDE A POSITIVE DRAINAGE PATH AWAY FROM
FOUNDATION, THE FALL SHALL BE A MINIMUM 6 INCHES IN THE FIRST 10 FEET
5% SLOPE PER 2012 IBC.
2. WHERE LOT LINES OR OTHER PHYSICAL BARRIERS PREVENT SLOPING AWAY
FROM THE STRUCTURE AT A MINIMUM OF 5% FOR 10 FEET (6 INCHES); SLOPE
AWAY AT A MINIMUM OF 5% INTO A SWALE THAT IS SLOPED TO PROVIDE POSITIVE
DRAINAGE AWAY FROM THE BUILDING TO THE STREET R,O.W. THE FINISHED FLOOR
ELEVATION SHALL BE AT LEAST 12 INCHES ABOVE THE HIGHEST ELEVATION OF
THE BOTTOM OF THIS SWALE.
3, FINISH FLOOR ELEVATION SHALL BE 12 MIN. INCHES ABOVE THE NEAREST
SANITARY SEWER MANHOLE OR 4 INCHES ABOVE CROWN OF THE STREET PER
LANDSCAPING NOTES: 2012 IBC.
1. LANDSCAPING PER SECTION 106-800. _
2. LANDSCAPE FRONTAGE PER 106-443 FOR COMMERCIAL DEVELOPMENT,
3, PLANTING STRIP PER SECTION 106-800(C.i.B&C) '=
cc
i
_ Ii I __ , REPLACE EXST.
C. OF LP EAST/WEST ALLEY _ M.H. ! _ _ _ _ _ _ _ = 8" 5.5. (CITY) - - - - - - - - - - - - _j i
(EXIST. A'_PHAIT DRIVE)- - - i - - �' M.H.
3/4" METER I "
W/PROP. 2" TAP �c
10" W.L. (CITY) 8" W.L. CITY ii ' P.P. & METER W RPZ I `"
---------_--------- v------- ---------------------------------->------------------------------- _ /
------------------------- - -------------------------------------------------------------------
- -'�- S BACKFLOW I
' OVERHEAD PREVENTOR
PROP. 6" � i
POWER
S.S. TAP EAST 125,00' ii LINE
P.P' PROP. (4) PROP. (2) J1i J
i v l PROP. 2 i l i
() H.C. RE-SEALMETER CANS 12 w x 0.0
METAL GATES
GATE W/SIGNAGE PAVING
PROP. 16'w. o PARKING SPACES (ASPHALT) °°' _ I =? I
y a
PROP. 6" i i ° % PROP. ¢ 7
ii
PROP. PRO BALCONY ,� ;o / ,1 8" W L CITY �i
S.S. LINE �.0. al - S -0' 8'- STRIPE APT,-2 �G �G �G �G ,i __ _._O.A, ®�� W.L.
._. (CITY) _
f� PROP. 6�•5.5.� W,61, ______________
PROP. CONC. 5�' - --,- ----•- - ---,-,--
WHEEL5TOP5, i _ VAN H.C.
TYP
CP-
4ti
TY
U.N.
i
I PROP • �� '
LANDSCAPE TABLE:
I
I
SYMBOL:
COMMON NAME:
SCIENTIFIC NAME:
SIZE;
# EXIST,
# REO'D:
# PROP:
# TOTAL:
(MIN. 5 GAL.
'
SHRUBS, 2"
CALIPER TREES)
+ +
+ + +
GRASS
-
-
-
-
PLANTING
O
180 SF.
200 SF,
200 ST.
STRIP
LIVE OAK
QUERCUS
36" CALIPER
2
2
0
i
2
VIRGINIANA
BOXWOOD
BUXUS
HT. 18"-22"
0
20
20
20
SHRUB
SEMPERVERINS
1 PER 3' O.C.
PARKING LOT REQUIREMENTS
PER SECTION 106-800(c.1.e)
NUMBER OF PARKING SPACES
PROVIDED:
3
NUMBER OF TREES REQUIRED
(1 TREE PER 10 PARKING SPACES) =
2
SPECIES OF SHADE TREES PROVIDED AS PARKING LOT LANDSCAPING:
4
PLANTERS REQUIRED (135 SF.
PER 10 PARKING SPACES) _ (135 SF.) x
(1.3) =
180 SF.
PROP. 5'w. (CONC.) WALK
I 8
75
4
3
o
o
4'w
GM
i
I
MTL.
STAIR
1-1
13
PROP. (2)
GAS METERS syty
-�-'.
L
GMAT 2
P.O.A.
�44
a
6't. WD.
.'.'.' ._ .
DEMO &
(GONG.)
titi
PROP. 5'w.
_
:._FENCE-
REPLACE
• 'i�
�jA[F�
(CONC.) WALK
r
of i.
PROP ".'.'_'.'.
2nd FLOOR
ROOF
12
J
,o
PLAYGROUND
.'.'.`.'.'.'.'_ _
-
v z
o � I
'P�20f�. LANDSCAPE ...
P. -
LANDSCAPE - -
( )' -
1 1
PROP. SAMPLE
-. -
PROP.:.' . ' .BALCONY
APT,-1
EXIST.
O'O
WELL AFTER
- _ CREASE TRAP
J
c.
2-STORY
I NRY &
MASO WD
1G
EXISTEAL
L
I
�� REPLACE EXIST. 1-STORY WD
U
I
PH T A5 AL 5
FRAME BLDG. (CONC. SLAB E.T.R) I FRAME BLDG. PARKING O C�
TYPE III-B (2,112 SF.) I I TYPE III-B --D SPACES I�
PROP. 300 I PROP. 5' CONC. I I (4,104 SF.) 0 9 7�
GAL. GREASE LANDING W/H.C. RAMP
TRAP -- ------ -
4 . i -
BUILDING AND FACILITIES SHALL BE WITH DESIGNED AND CONSTRUCTED IN ACCORDANCE
I W 101-336 HIGHLIGHTED AS FOLLOWED. 3: Buildin Blocks. �• '•-� 1 WALK
ANSI A 1171 AND A.D.A.PUBLIC LA g i �•J�, /•
302 Floor or Ground Surfaces
302.1 General - Floor and ground surfaces shall be stable, firm, and slip resistant and shall comply with 302.
302.2Carpet - Carpet or carpet file shall be securely attached and shall have a firm cushion, pad, or hacking or no cushion or pad.
Carpet or carpet tile shall hove a level loop, textured loop, level cut pile, or level cut/uncut pile texture. Pile height shall be 1/2 inch
(13 mm) maximum. Exposed edges of carpet shall be fastened to floor surfcces and shall have trim on the entire length of the exposed
edge. Carpet edge trim shall comply with 303.
303 Changes in Level
303.1 General - Where changes in level are permitted in floor or ground surfaces, they shall comply with 303
303.2Verticol - Changes in level of 1/4 inch (6.4 mm) high maximum shall be permitted to be vertical.
303.313eveled - Changes in level between 1/4 inch (6.4 mm) high minimum and 1/2 inch (13 mm) high maximum shall be beveled with
a slope not steeper than 1:2.
303.4Remps - Changes in level greater than 112 inch (13 mm) high shall be ramped, and shall comply with 405 or 406.
Chaster 4: Accessible Routes.
403 Walking Surfaces.
403,1 General - Walking surfaces that are a part of an accessible route shall comply with 403.
403.2FIoor or Ground Surfaces - Floor or ground surfaces shall comply with 302.
403.3SIope - The cross slope of walking surfaces shall not be steeper than 1:48-
403AChanges in Level - Changes in level shall comply with 303-
403.5 Clearances - Walking surfaces shall provide clearances complying with 403.5.
403.5.1 Clear Width - Except as provided in 403.5.2 and 403.5.3, the clear width of walking surfaces shall be 36 inches (915 mm)
minimum.
404 Doors, Doorways, and Gates.
404.2.5 Thresholds - Thresholds, if provided at doorways, shall be 1/2 inch (13 mm) high maximum. Raised thresholds and changes
in level at doorways shall comply with 302 and 303.
Chapter 7: Communication Elements and Features.
216.4.1 Exit Doors - Doors at exit p❑ssagewoys, exit discharge, and exit stairways shall be identified by tactile signs complying with
703,1, 703.2, and 703,5.
703 Signs.
703.2Raised Characters - Raised characters shall comply with 703.2 and shall be duplicated in braille complying with 703.3. Raised
characters shall be installed in accordance with 703.4.
703.2.1 Depth - Raised characters shall be 1/32 inch (0.8 mm) minimum above their background.
703.2.2 Case Characters shall be uppercase.
703.2.3 Style - Characters shall be sans serif. Characters shall not be italic, oblique, script, highly decorative, or cf other unusual
forms.
703.41nstollation Height and Location. Height Above Finish Floor or Ground - Tactile characters on signs shall be located 48 inches
(1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches
(1525 mm) maximum above the finish floor or ground surface, measured from the baseline of the highest tactile character. Where a
tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Signs containing tactile characters shall
be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile
beoj� jhe orc of any door swing between the closed position and 45 degree open position.
70o�f�lt°Pf�oTiz�ku�ly characters shall comply with 703.5. EXCEPTION: Where visual characters comply with 7D3.2 and are
act �n� SbyP rail' Vg)pI&g with 703.3, they shall not be required to comply with 703.5,2 through 703.5.9. Finish and Contrast -
Characters and their ac ground shall' have a non -glare finish. Characters shall contrast with their background with either light characters
on -a �arFc�acicground or dark charocters on a light background.
(CdNC.)
WEST 125,00'
SiD
ALK
-- _
--4 L_,_ _ ____ __
-. - -I
-
RAMP
i
-
0
-
_
--
--- ----- --------- ------
35'
0"
18" 18" S.D. I
CLOSE EXIST. DRIVEWAY
PROP. 5'w. (MIN.)
REMOVE EXIST. ASPHALT &
PROP. 2nd FLR.
STORM DRAIN
■
APPROACH. PROP.
CONC. CURB H.C. RAMP & WALK
REPLACE W/PROP. SOD &
BALCONY W/(4)
INLET #F212-0329
■
& SIDEWALK TO MATCH EXIST,
TO SIDEWALK
LANDSCAPING (700 51`.)
COLUMNS & METAL
AWNING (APT,-1)
-
Main
St.
(60'R.O.W.)
------------------------
-� ____ ____W.
t
I■
I ■
I
Construction Site Plan
D' 40' = Q
NOTE:
1. ALL ITEMS ARE EXIST. UNLESS NOTED PROP.
Design Criteria:
DESIGN WIND LOAD:
150 MPH
(2015 IBC, CHAPTER 26)
INCIDENTAL USE AREA:
NONE
(TABLE 508.2, PG. 80)
FIRE RATING OF
0 HOURS
BUILDING COMPONENTS:
(TABLE 601, PG, 87)
WALL RATING AS
REQUIRED FOR DISTANCE
0 HOURS
SEPARATION TO PROP.
LINE: (TABLE 602, PG. 138)
MAX. BLDG. AREA:
23,000 SF.
(SECTION 503, PG. 76)
MAX. BLDG. HT.:
4 STORIFS
(SECTION 503, PG. 76)
DESIGN FLOOR LOAD:
125 LBS. to 250 LBS.
(TABLE 1607.1, PG. 286)
DESIGN ROOF LOAD:
UNIFORM LOAD = 20 PSF,
CONCENTRATED = 300 PSF.
(TABLE 1 607.1 , PG. 285)
1ST FLOOR:
BUSINESS = (5,151 SF.)
2ND FLOOR: APARTMENT-1 = 1,800 SF. _ (3,135 SF.)
APARTMENT-2 - 1,335 SF.
BUILDING AREA (TOTAL):
(5,286 SF.)
BUILDING HEIGHT:
2-STORY
BUILDING TYPE:
DI-B % SPRINKLER PER IBC 903.2.8
BUILDING GROUP:
1ST FLOOR: GROUP 8 100% (WITH R-3 ABOVE)
1ST FLOOR: GROUP B 0% (1-STORY BLDG ONLY)
2ND FLOOR: GROUP R3 100% (ENTIRE 2ND FLOOR)
FIRE SEPARATION:
0.5-HR. HORIZONTAL BETWEEN FLOORS (PER IBC 711.2.4.3 EXCEP.)
O.5-HR VERTICAL BETWEEN APARTMENTS (PER IBC 708.3)
Index (Minor Site Plan):
Al -- CONSTRUCTION SITE PLAN
A4 - EXTERIOR ELEVATIONS
Scone of Work:
1. DEMO 2,112 SF. 1-STORY BLDG.
2. PROP, 2,112 SF. 1-STORY BLDG.
3. INTERIOR REMODEL OF 2-STORY EXIST. BLDG.
4. REPLACE EXIST. 2ND FLOOR FLOORING SYSTEM.
3- REPLACE EXIST. 2ND FLOOR ROOF.
4. RE -STRIPE EXIST. CONCRETE PAVING.
5- PROP. MECHANICAL (HVAC) SYSTEMS.
6. PROP_ ELECTRICAL SYSTEM.
7. PROP, PLUMBING SYSTEM.
8. PROP. RESTROOMS
Flood Statement:
THIS TRACT IS IN FLOOD ZONE: 'X'
AND IS WITHIN THE 100--YEAR FLOOD PLAIN ACCORDING
TO F.E.M.A. MAP � 48201CO945M, DATED JANUARY 06,
2017.
Parkin
(PER THE CITY OF LA PORTE - CODE OF ORDINANCES)
PARKING TABLE
STANDARD PARKING SPACES REQUIRED:
B
R3
TOTAL:
GROUP B (4 MIN.) + (1 PER 1,000 SF.)
GROUP R3 (2 PER RESID.) x (2 RESID.)
9
+
4
=
13
STANDARD PARKING SPACES PROVIDED
9
+
4
=
13
ACCESSIBLE PARKING SPACES REQUIRED
1
+
0
=
2
PARKING NOTES:
1, STANDARD PARKING SPACE - 9' x 18' W/25' (MIN.) DRIVE AISLES,
2. PARKING REQUIREMENTS AS OUTLINED PER ARTICLE VI, CHAPTER 106.
3, PARKING RATIO PER SECTION 106-839.
4. ACCESSIBLE PARKING PER ADA/TEXAS ACCESSIBILITY STANDARDS,
DRIVEWAY NOTES:
1. DRIVEWAY ACCESS PER HARRIS COUNTY AND/OR TXDOT APPROVAL
FOR ALL ACCESS ONTO PUBLIC ROADWAYS MAINTAINED BY SAID
ORGANIZATION.
2. DRIVEWAY ACCESS POINTS PER SEC. 106-835, FIG. 10-2 & 10-3.
3. DRIVEWAY APPROACH SHALL BE (MAX. 5%) SLOPE.
City GIMS Mapping
(NOT TO SCALE)
Site Data
Table:
NAME OF DEVELOPMFIVT:
THE CHAMBERS BUILDING
TYPE OF DEVELOPMENT:
REMODEL EXIST.
MIXED USE BUILDING
LEGAL DESCRIPTION:
LOTS 18 19 20 & 21 & S
14 FT OF LOT 22 BLOCK 60
LA PORTE, TX.
ADDRESS OF SITE:
100 W MAIN ST.
LA PORTE, TX 77571
SIZE OF LOT/PROPERTY:
14,250 SF. (0.327 AC.)
BUIDLING FOOTPRINT:
5,151 SF.
LOT COVERAGE:
36.1 %
ZONING OF THE SITE:
MAIN STREET DISTRICT
AUTHORIZED AGENT:
MRGINIA & BILLY JACK TALTON, JR.
HCAD:
0231930000042
NAILS CODE:
(REAL ESTATE PURPOSES ONLY)
SPEC BUILDING
Building Codes:
2012 INTERNATIONAL BUILDING CODE (IHC)
2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
2012 UNIFORM MECHANICAL CODE (UMC)
2012 UNIFORM PLUMBING CODE (UPC)
2011 NATIONAL ELECTRICAL CODE (NEC) W/LOCAL AMENDMENTS
2015 INTERNATIONAL FIRE CODE (IFC)
W/ADOPTED AMENDMENTS TO FIRE CODE
City Approving Authority Certificate:
This is to certify that on ---------- day of ---------- 2020 the City of Lo Porte,
Texas, has approved this site plan and development of THE CHAMBERS BUIDLING in conformance
with the ordinances of the City of Lo Porte.
By: - - - - --------
Director, Planning & Development
By: iyvp
--------------
anner
Y. ` --- - - - -
City 7 eer w-
Owners Certificate:
I MARIOS S. CAMPISE, as Owners of the 14,250 SF. (0.327 AC.) track
described in the above and foregoing site plan of THE CHAMBERS BUILDING
do hereby establish said development of said property according to all lines, dedications,
restrictions and notations on said site plan, I MARIOS S. CAMPISE further certify that all
improvements shown on said site plan shall be constructed in the
locations shown.
ADDITIONAL PARAGRAPHS TO BE ADDED AS APPROPRIATE
- When development contains natural drainage ways surh as bayous, creeks, gullies, ravines,
draws or drainage ditches:
FURTHER, Owners agree to keep all of the property within the boundaries of this site plan and
adjacent to any drainoge easement, ditch, drainage ways and easements clear of fences,
buildings, planting and other obstructions to the operations and maintenance of the drainage
facility and that such abutting property shall not be permitted to drain directly into this
eosement except by means of an approved drainage structure.
- When private streets and utilities are established with n the site plan:
FURTHER, Owners agree that those streets and utilities located within the boundaries of this site
plan specifically noted as private, shall be maintained as private streets and utilities by the
owners, heirs, successors and assigns and, further, that said private streets shall always be
available for the general use of the public for firemen, firefighting equipment, police and other
emergency vehicles of whatever nature at oil times.
When owner is on individual or individuals
WITNESS my (or our) hand in the City of ______________, -------------- this day
of_ --------- 2020,
(Name of Owner/s)
When owner is ❑ company or corporation In TESTIMONY WHEROF, the (Name of company) has
caused these presents to be signed by (Name of President), its President thereunto authorized,
attested by its Secretary (or authorized trust officer), (Nome of Secretary of `llr� trust
officer), and its common seal hereunto affixed by this ---------- day � �-xj
2020.
or
(name of owner) - MARIOS S. CAMPISE ;;00
i
�R g
g8
d
No
C
�o\ASS I oN N"-:
Civil Engineer.
�J_i_L -
I, __� � � f �M REGISTERED UNDER THE LAWS
TQ OF TEXAS PRACTICE THE PROFESSION OF ENGINEERING IQ,
AND HEREBY CERTIFY THAT THIS MINOR SITE PLAN IS
TRUE AND CORRECT AS TO PROPOSFD SITE IMPROVEMENTS.
V D
OCT 0 6 2020
BY:
TEXAS REGt
TION NO. -7-L-q 7S
This is to certify that the City of La Porte, Texas has approved this
site plan and development of THE CHAMBERS BUILDING
in conformance with the laws of
the State of Texas and the ordinances of the City of La Porte.
Design:
_ B. Jack Talton Jr.
1906 Du Barry Ln,
Houston, TX 77C18
ARCHITECTURE 713.320-9780
DEsnvc;rnERMrrTLvc�
bill yjacktalton@hotmail.com
Engineering:
TRINITY BAY ENGINEERING
General Contractor:
ASPENDORA
CONTRACT®RS
Owner:
MARIGN S
S. CAMPISE
Project
THE
�HAMB�RS
BUILDING
Legal Description:
LOTS 18 19 20 &
21 & S 14 FT OF
LOT 22 BLOCK 60
LA PORTE, HCAD:
0231930000042
Issued For:
Sheet Name:
Construction Site Plan
02.11,20 P.A.K. MTG.
10,06.20 MINOR SITE PLAN, RE-SUBMITTAL-3
02.24.20 ECONOMIC DEVELOPMENT REVIEW
Scale:
07.15.20 ENHANCEMENT GRANT PROGRAM
Rodney Siaton, P.E,
911 S. 8th STREET
LA PORTE, TEXAS 77571
281.515.10fi5/281.827.3929 cell
rodney@trinitybayengirieering.com TBPE # 18351
�
MARTY
1902 Roscoe
LaPorte, TX 77571
713.283,4013
camp isemart @ aho0.com
Bryan Moore
511 South Utah St,
LaPorte, TX 77571
281 .9 32.3128
brycn@ospendore.com
07-27.20 MINOR SITE PLAN, SUBMITTAL-1
Sheet NLlmber.
A I
08.03,20 MINOR SITE PLAN, SUBMITTAL-1
(REV. PER H.C. R.O.W. REVIEW)
08.17.20 MTG @ CHAMBER of COMMERCE
100 W Main Street, La Porte, TX. 77571
09.15.20 MINOR SITE PLAN, RE-SUBMITTAL-2
1
Abbreviations: Key Map:
Site Data Table:
aZ5�1 WQL
%
Performance Standards:
eft 'A 4=1
r..r-
e4
Fe -
gend:
Scope of Work:
�!n w.". 111Y QV-
ILV 06' 11US5 NOTE 1R��
..........
Flood Staternmr.
Parking:
I XIST
MOY
WIIRY
- ------
MAW ULM
Texas Accessibility Gui&fines.
OTI
9 1 TF—
I.dAw,.4q
I
W. Main SI - -------
--- - - -------------
---------
L =XI
■
Plot Plan
PP-1
ea+(o Cw er