Loading...
HomeMy WebLinkAboutLA PLAZA SITE PLANPRE-DEVELOPMENT DRAINAGE PLAN TOPO SURVEY CIVIL: COVER SHT. TITLEDRAWING NO. C-2.0 C-1.1 C-1.0 - SITE PLAN SWPPP PLAN SWPPP DETAILSC-3.1 LA PLAZA C-3.0 LA PORTE, TX 77571 2459 UNDERWOOD ROAD, LANDSCAPING PLAN DRAWING INDEX SCOPE OF WORK: PROPOSED GAS STATION WITH CANOPY, SHOPPING CENTER HOUSTON, TX 77094 P. O. BOX 940161 TEL: 713-298-0297 FAX: 281-239-2710 MAK Design & Drafting LLC JIN LEE OWNER CITY OF LA PORTE C-5.0 48 HOUR NOTICE: CONTRACTOR SHALL NOTIFY HARRIS COUNTY PRIOR TO COMMENCING CONSTRUCTION AND / OR BACKFILLING ANY UTILITIES. CONTRACTOR(S) TO CONTACT PUBLIC REVIEW DEPARTMENT @ (713-274-3931) OR PUBLIC.REVIEW@HCPCID.ORG DRAINAGE AREA MAPC-2.1 PROPOSED DRAINAGE PLANC-2.2 C-1.3 C-1.2 PAVING PLAN SITE DETAILS DRAINAGE CALCULATIONSC-2.3 PLAT - - TRAFFIC CONTROL PLAN C-4.0 UTILITY PLAN C-4.1 DETAILS C-4.2 DETAILS C-4.3 DETAILS CBGTEXASNPLAN SHEET C-1.0 TITLE PROJECT SITE HOUSTON, TX 77094P.O.BOX 940161TEL: 713-298-0297 FAX: 281-239-2710201919 07-01-19 PROJECT NO. DATE SCALE 1 =30- 0 JIN LEE OWNERDATEISSUE / REVISIONNOMAK Design &Drafting LLC MAK EngineeringF-12117LA PORTE, TX 77571 2459 UNDERWOOD RD. LA PLAZA NOTE: FUEL DISPENSING SHALL BE PROHIBITED WITHIN 25 FEET OF ANY SOURCE OF IGNITION (2018 IFC SECTION 5706.4.5(17)) City Approving Authority certificate: This is to certify that on ________day of _________, 20__ the City of La Porte, Texas, has approved this site plan and development of LA PLAZA in conformance with the ordinances of the City of La Porte. By: ______________________________ Director, Plannin g and Development ______________________________ City Planner _______________________________ City Engineer 16th June 21 This Drawing has been reviewed and found to be: in compliance not in compliance (see markups) -> RESUBMIT Approval of these plans does not relieve the contractor of responsibility of ensuring proper construction per City ordinances. Any deviation from approved plans must be submitted to the City for review and approval prior to construction. Date: ________________ By: 6/22/2021 X CBGTEXASNPLAN SHEET C-1.1 TITLE PROJECT LANDSCAPINGHOUSTON, TX 77094P.O.BOX 940161TEL: 713-298-0297 FAX: 281-239-2710201919 07-01-19 PROJECT NO. DATE SCALE 1 =30- 0 JIN LEE OWNERDATEISSUE / REVISIONNOMAK Design &Drafting LLC MAK Engineering F-12117LA PORTE, TX 77571 2459 UNDERWOOD RD. LA PLAZA CBGTEXASNPLAN SHEET C-1.2 TITLE PROJECT PAVING HOUSTON, TX 77094P.O.BOX 940161TEL: 713-298-0297 FAX: 281-239-2710201919 07-01-19 PROJECT NO. DATE SCALE 1 =30-0 JIN LEE OWNERDATEISSUE / REVISIONNOMAK Design &Drafting LLC MAK Engineering F-12117LA PORTE, TX 77571 2459 UNDERWOOD RD. LA PLAZA SITE 4 1/2"   ... CEMENT CONCRETE, 5 SACK CEMENT PER CUBIC YARD, 7 INCHES PROPERTY, SAID DRIVEWAYS SHALL BE SEPARATED BY A MINIMUM 10. IF MORE THAN ONE PROPOSED DRIVEWAY IS BUILT ON THE SAME DISTANCE OF 20 FEET (ROADWAYS WITH CURBS AND SIDEWALKS). SUBGRADE. (3 INCHES MANUFACTURED CHAIRS ARE REQUIRED WITH 11. REINFORCING STEEL TO BE ELEVATED A MINIMUM OF 3" ABOVE MAXIMUM SPACING OF 72 INCHES C/C EACH WAY). THICK, FROM PROPOSED SAW CUT TO RIGHT-OF-WAY LINE LAP (6"x12" W5xW4 AS ALTERNATE) FROM PROPOSED SAW CUT SPACED AT 24 INCHES C.C., EACH WAY, WITH 10 INCHES MINIMUM 4. PROPOSED DRIVEWAY REINFORCING STEEL IS TO BE #4 DEFORMED EXISTING ROADWAY REINFORCING STEEL WITH A MINIMUM LAP 5. PROPOSED DRIVEWAY REINFORCING STEEL IS TO BE TIED TO 6. PROPOSED GUTTER LINE IS TO BE MAINTAINED AT FACE OF 7. SAW CUT EXISTING CURB AT EACH END AND KNOCK OUT CURB FROM BEGINNING TO END OF PROPOSED DRIVEWAY. FROM FACE OF CURB (GUTTER LINE) AND BREAK OUT TO EXPOSE 8. SAW CUT EXISTING PAVEMENT A MINIMUM OF 12 INCHES AWAY PROPOSED SAW CUT AT EXISTING PAVEMENT TO RIGHT-OF-WAY 9. COMPACT SUBGRADE FOR PROPOSED DRIVEWAY CONNECTION FROM LINE, COMPACT TO 95% OF STANDARD PROCTOR DENSITY (+/- 2% OPT. MOISTURE). THE COUNTY ENGINEER RESERVES THE RIGHT TO REQUIRE LABORATORY TESTS TO BE CONDUCTED. (PROPERTY LINE). TO RIGHT-OF-WAY LINE. OF 8 INCHES. EXISTING CURB. EXISTING REINFORCEMENT STEEL. 1. PROPOSED DRIVEWAY, SIDEWALK, CURB, GUTTER LINE AND GRADE 2. PROPOSED SIDEWALK SHALL BE CONSTRUCTED WITH PORTLAND 3. PROPOSED DRIVEWAY SHALL BE CONSTRUCTED WITH PORTLAND CEMENT CONCRETE, 4-1/2 SACK CEMENT PER CUBIC YARD, 4-1/2 INCHES THICK AND 4 FEET MINIMUM WIDTH. SEE DRAWING NO.3 FOR ADDITIONAL INFORMATION AND DETAILS. SHALL MATCH EXISTING STREET. GENERAL NOTES: R.O.W. LINE 18" STANDARD (SEE GENERAL NOTE NO.7) 3" CLEARANCE (TYP.) 7" THICK REINFORCED CONCRETE 3" CLEARANCE 12" 6" PAVEMENT CUT UNDER EXISTING 6" 24" NEW PAVEMENT EXISTING PAVEMENT GUTTER LINE 8" STEEL OVERLAP 12" PROP. SAW CUT PREFORMED JOINT OR 1/2" NON-EXTRUDING 1" BOARD EXPANSION #4 @ 24" C/C COMPACT SUBGRADE TO 95% STANDARD PROCTOR DENSITY EXIST. CURB BACK OF 4' MINIMUM 2' NON-EXTRUDING PREFORMED JOINT 1" BOARD EXPANSION OR 1/2" 1:50 MAX CROSS SLOPE DETAILS C-1.3 SHEET TITLE PROJECT HOUSTON, TX 77094P.O.BOX 940161TEL: 713-298-0297 FAX: 281-239-2710PROJECT NO. DATE SCALE N.T.S. OWNERDATEISSUE / REVISIONNOMAK Design &Drafting LLC MAK Engineering F-12117JIN LEE 201410 05-25-20 LA PLAZA LA PORTE, TX 77571 2459 UNDERWOOD RD. MAK Design &Drafting LLC MAK Engineering F-12117 CBGTEXASN0.18 A-11 0.15 A-3 0.15 A-5 0.18 A-6 0.19 A-4 0.22 A-8 0.17 A-9 0.20 A-10 0.19 A-10.17 A-2 0.19 A-7 ACREAGE DRAINAGE AREA AREA MAP SHEET C-2.1 TITLE PROJECT DRAINAGEHOUSTON, TX 77094P.O.BOX 940161TEL: 713-298-0297 FAX: 281-239-2710201919 05-25-20 PROJECT NO. DATE SCALE 1 =30-0 JIN LEE OWNERDATEISSUE / REVISIONNOMAK Design &Drafting LLC MAK Engineering F-12117LA PORTE, TX 77571 2459 UNDERWOOD RD. LA PLAZA Δ Δ Δ BOP AREA 4913 S.F. GUY WIRE OHPOHP10.0'10.0'21.0' √STMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMPROP. 90 LF 24" Ø PVC @ 0.20% SLOPE BOP ELEV. 17.0 TC 26.75 TC 26.25 TC 26.75 TC 26.75TC 26.75TC 26.758100 S.F.TP 25.75TP 25.75TP 25.75TP 25.75TP 25.75 TP 25.75 TP 25.75 TP 25.75TP 25.75TP 25.75TC 26.25 TP 25.75 TC 26.25 TP 25.75 TC 26.25 TP 25.75 TC 26.25 TP 25.75 TC 26.25 TP 25.75 TC 26.25 TP 25.75 TC 26.25 TP 25.75 TC 26.25 TP 25.75TC 26.25TP 25.75TC 26.75 TP 25.75 TC 26.25 TP 25.75 TC 26.25 TP 25.75 TC 26.25 TP 25.75 TP 25.75 TP 26.25 TP 25.75TC 26.25 TP 25.75 STEPSTEPSTEPSTEPSTEP STEP STEP PROP. 85 LF 12" Ø PVC @ 0.20% SLOPE PROP. 60 LF 15" Ø PVC @ 0.20% SLOPE PROP. 130 LF 18" Ø PVC @ 0.20% SLOPE PROP. 80 LF 24" Ø PVC @ 0.20% SLOPE PROP. 95 LF 12" Ø PVC @ 0.20% SLOPE PROP. 128 LF 12" Ø PVC @ 0.20% SLOPE PROP. 49 LF 12" Ø PVC @ 0.20% SLOPE PROP. 94 LF 15" Ø H.D.P.E. @ 0.20% SLOPEPROP. 50 LF 12" Ø PVC @ 0.20% SLOPEPROP. 47 LF 24" Ø RCP @ 0.20% SLOPE PARKING LOT CROSS SECTION (TYP.) NOTE: FLOW LINE PARKING LOT CROSS SECTION (TYP.)0.75' BLDG. WALL F.F. ELEV. 27.00 TC 26.25 PROP.BB-I7 TOP 25.00 FL -- 19.89 SIDE WALK TP 25.75 TC 26.25 TP 25.75 EL 26.75 MAX. WATER SURFACE ELEVATION 25.75 STEP TC 26.25TP 25.75 TC 26.25 TP 25.75 TC 26.25 TP 25.75STEP TC 26.75TC 26.75TC 26.25 TP 25.75 0.15 A-3 0.14 A-5 0.16 A-6 0.19 A-4 0.22 A-8 0.17 A-9 0.19 A-10 0.19 A-1 0.17 A-2 0.18 A-11 0.19 A-7 6" RESTRICTOR DETENTION POND CROSS SECTION (TYP.) SCALE: N.T.S.1'-0" FREEBOARDPROP. 45 LF 24" Ø RCP @ 0.38% SLOPE MAK Design &Drafting LLC MAK Engineering F-12117 I = b (d + Tc)e Tc = 10A + 150.1761 RAINFALL INTENSITY : INITIAL TIME OF CONCENTRATION: VELOCITY V =1.49 n 2/3R S1/2 PIPE DISCHARGE Q = VA WHERE, A = D 4 2 CALCULATIONS SHEET C-2.3 TITLE PROJECT DRAINAGEHOUSTON, TX 77094P.O.BOX 940161TEL: 713-298-0297 FAX: 281-239-2710PROJECT NO. DATE SCALE N.T.S. OWNERDATEISSUE / REVISIONNOMAK Design &Drafting LLC MAK Engineering F-121171. STORM SEWER PIPE USE FOR CONNECTION TO STORM SEWER IN PUBLIC R.O.W. SHALL BE REINFORCED CONCRETE PIPE ASTM C-76, CLASS III, WITH RUBBER GASKET PER ASTM C-443 AND SHALL EXTEND TO FIRST INLET OR MANHOLE. ALL OTHER PRIVATE STORM SEWER MAY BE H.D.P.E. OR APPROVED EQUAL. 2. STORM SEWER SHALL BE CONSTRUCTED IN ACCORDANCE WITHTHE LATEST HARRIS COUNTY STANDARD CONSTRUCTION SPECIFICATIONS FOR STORM DRAINAGE INCLUDING ALL CURRENT AMMENDMENTS THERETO. 3. ALL SEWER UNDER PROPOSED OR FUTURE PAVEMENT AND TO POINT ONE (1) FOOT BACK OF ALL PROPOSED OR FUTURE CURBS SHALL BE BACKFILLED WITH 1 1 2 SACK CEMENT/C.Y. STABILIZED SAND TO WITHIN ONE (1) FOOT OF SUBGRADE. CEMENT STABILIZED SAND TO BE IN ACCORDANCE WITH THE REQUIREMENTS OF ASTM C 33, LATEST EDITION. RUN OFF Q = CIAA DETENTION PROVIDED : PARKING LOT DETENTION STORAGE VOLUME PROVIDED =0.7 AC-FT DETENTION SUMMARY TOTAL IMPERVIOUS AREA = 2.41 ACRE = 105,026 SF EXISTING PERVIOUS AREA = 0 DETENTION VOLUME REQUIRED = 2.23 AC X 0.75 AC-FT/AC PROPOSED BUILDING 20,040 S.F. FUTURE LAND DEVELOPMENT = 0 DETENTION RATE = 0.75 AC-FT/AC = 1.7 AC-FT TOTAL DETENTION STORAGE VOLUME PROVIDED = (0.7 + 1.7) AC-FT= 1.7 AC-FT DETENTION POND STORAGE VOLUME PROVIDED = 1.0 AC-FT TOTAL DETENTION STORAGE VOLUME PROVIDED = TOTAL DETENTION STORAGE VOLUME REQUIRED 24" PVC 6" PVC PIPE RESTRICTOR NOTE: 1. RESTRICTOR PIPE SHALL BE GROUTED IN PLACE FROM END TO END.   2 OUTFLOW RESTRICTOR DESIGN: PREDEVELOPMENT PEAK FLOW TOTAL EASEMENT AREA = 7,700 S.F. 201410 05-25-20 JIN LEE LA PLAZA LA PORTE, TX 77571 2459 UNDERWOOD RD. TOTAL OUTFALL RATE FOR PROPOSED PROPERTY = 5.40 DRAINAGE ANALYSIS 2 - YEAR STORM EVENT STORM SEWER CALCULATION (PROPOSED PROPERTY) AREA PIPE RUN FROM TO RUN-OFF TOTAL AREA (AC) RUN-OFF AREA (AC) DRAINAGE "A" "A" A-2 I I A-3 A-6 2 4 I3 I6 0.17 0.36 0.15 0.15 0.16 0.30 I4 A-5 I5 0.14 0.14I6 A-7 I I A-9 7 8 I9 0.19 0.49 0.22 1.41 0.19 1.77POND I9 A-10 I10 I7 A-1 I1 0.19 0.19 A-4 I4 0.19 0.70I8 A-8 I8 0.17 1.58I10 0.18 1.95A-11 POND CONCENT.CO-EFF.RUN-OFF T (MIN)"C"I (IN.)Q (CFS) TIME OF C RAIN FALL INTENSITY TOTAL RUN-OFF Q (CFS)A A MANNING PIPE DIAM.LENGTH "n"(IN)(LF) REACH 0.01 (S) SLOPE % 0.01 0.01 128 49 85 0.01 50 0.01 0.01 0.01 60 130 80 0.01 95 0.01 94 0.01 90 VELOCITY R (FT)V (FT/SEC)"Q" HYDRAULIC RADIUS 2.86 DISCHARGE (CFS) PIPE 18.18 2.86 2.86 2.86 5.19 8.44 2.86 DISCHARGE OK 5.19 18.18 18.18 10 - YEAR STORM EVENT RUN-OFF I (IN.)Q (CFS) RAIN FALL INTENSITY TOTAL RUN-OFF Q (CFS) 0.63 1.42 A A 0.59 0.59 0.63 1.18 0.55 0.55 0.75 1.93 0.86 5.55 0.75 0.75 0.75 2.76 5.2 5.3 5.3 5.2 5.3 3.75.3 5.2 5.2 100 - YEAR STORM EVENT RUN-OFF I (IN.)Q (CFS) RAIN FALL INTENSITY TOTAL RUN-OFF Q (CFS) 0.93 1.97 A A 0.83 0.83 0.88 1.65 0.77 0.77 1.04 2.69 1.20 7.73 1.04 1.04 1.04 3.84 7.3 7.322.3 22.2 22.2 22.1 22.5 22.5 22.5 22.5 22.3 22.5 22.4 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 0.46 0.41 0.43 0.38 0.51 0.59 0.51 0.51 0.51 0.46 0.49 0.97 0.41 0.81 0.38 1.32 3.80 4.91 0.51 1.89 4.40 5.40 0.25 0.50 0.25 0.25 0.31 0.25 0.25 0.31 0.38 0.50 0.50 3.6 3.6 3.6 3.6 4.2 4.8 5.8 3.6 4.2 5.8 5.8 12" 24" 12" 12" 12" 15" 18" 12" 15" 24" 24"0.01 47 0.20 0.67 6.22 0.75 6.97 0.71 7.68 5.3 5.2 5.2 0.93 8.66 1.04 9.70 0.99 10.69 I2 DISCHARGE OK DISCHARGE OK DISCHARGE OK DISCHARGE OK DISCHARGE OK DISCHARGE OK DISCHARGE OK DISCHARGE OK DISCHARGE OK DISCHARGE OK 7.3 7.3 7.4 7.3 7.3 7.3 7.3 7.3 7.3 PIPE PROPERTIESAREA PROPERTIES 10 YRS2 YRS 100 YRS b d e 93.5375.01 125.4 18.916.2 21.8 0.77420.8315 0.7500 FROM EXHIBIT 3-1 AND 3-2 HCFCD MANUAL DRAINAGE AREA = 2.23 ACRE IMPERVIOUS COVER 0% PREDEVELOPMENT PEAK FLOW : FOR 2 YRS = 1.8 CFS 10 YRS = 3.0 CFS 100 YRS = 4.8 CFS 0.18 1.95OUTFALL---18.1822.4 0.75 3.6 0.49 5.400.50 5.824"0.01 45 0.38 0.71 7.685.2 0.99 10.69 DISCHARGE OK7.3 I11 I11 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 CBGTEXASNMYRTLE CREEK DRIVEUND ER WO OD ROAD NOTE: 1. WORK THIS DRAWING WITH HARRIS COUNTY PAVEMENT CNST & MARK DET. DRAWING STABILIZED CONSTRUCTION EXIT INLET PROTECTION BARRIER (IPB) LEGENDS: PROPOSED INLET SC FILTER FABRIC FENCE WORK THIS DRAWING WITH SITE PLAN FOR DETAILS. NOTE: (STAGE I AND STAGE II PROTECTION REQUIRED) 2. ALL INLETS IN PROPOSED PAVED AREA NEEDS STAGE I AND STAGE II INLET PROTECTION. IPB IPB IPB IPB IPBIPB IPB IPB IPB IPB SCSCPLAN SHEET C-3.0 TITLE PROJECT SWPPP HOUSTON, TX 77094P.O.BOX 940161TEL: 713-298-0297 FAX: 281-239-2710201919 05-25-20 PROJECT NO. DATE SCALE 1 =30-0 JIN LEE OWNERDATEISSUE / REVISIONNOMAK Design &Drafting LLC MAK Engineering F-12117LA PORTE, TX 77571 2459 UNDERWOOD RD. LA PLAZA Δ Δ Δ CBGTEXASN“ ” – “ ” “ ” ’ “” ’ PLAN SHEET C-4.0 TITLE PROJECT UTILITY HOUSTON, TX 77094P.O.BOX 940161TEL: 713-298-0297 FAX: 281-239-2710201919 07-01-19 PROJECT NO. DATE SCALE 1 =30-0 JIN LEE OWNERDATEISSUE / REVISIONNOMAK Design &Drafting LLC MAK Engineering F-12117LA PORTE, TX 77571 2459 UNDERWOOD RD. LA PLAZA DETAILS SHEET C-4.1 TITLE PROJECT PROJECT NO. DATE SCALE N.T.S. OWNERDATEISSUE / REVISIONNOHOUSTON, TX 77094PO BOX 940161TEL: 713-298-0297 FAX: 281-239-2710MAK Design &Drafting LLC201918 JIN LEE 03-15-21 LA PLAZA LA PORTE, TX 77571 2459 UNDERWOOD ROAD DETAILS SHEET C-4.2 TITLE PROJECT PROJECT NO. DATE SCALE N.T.S. OWNERDATEISSUE / REVISIONNOHOUSTON, TX 77094PO BOX 940161TEL: 713-298-0297 FAX: 281-239-2710MAK Design &Drafting LLCJIN LEE 03-15-21 201918 LA PLAZA LA PORTE, TX 77571 2459 UNDERWOOD ROAD MAKEngineering F 12117 SIDE VIEW PLAN VIEW INLET FROM INTERCEPTOR OUTLET TO SEWER JOINT SEALED w/ NONSHRINK GROUT JOINT SEALED w/ NONSHRINK GROUT FRONT VIEW DETAILS SHEET C-4.3 TITLE PROJECT PROJECT NO. DATE SCALE N.T.S. OWNERDATEISSUE / REVISIONNOHOUSTON, TX 77094PO BOX 940161TEL: 713-298-0297 FAX: 281-239-2710MAK Design &Drafting LLCJIN LEE 03-15-21 201918 LA PLAZA LA PORTE, TX 77571 2459 UNDERWOOD ROAD MAKEngineering F 12117 CW20-1D 36" X 36" (Flags-See Note 1) Chevron Alignment (CW 1-8L) signs SHALL be placed on every other channelizing device along taper. END X ROADWORK \G20-2 36" X 18" ◊I ◊ I I. I I I I I I I I I I I I I I I I I I I I I I I I o!o END I ROAD WORK G20-2 36" X 18" I • • • I• •• I· •• I· •• I· ...J • * X ..... X ..... X ..... X CW20-1D 36" X 36" (Flags-See Note 1) Chevron Alignment (CW 1-8L) signs SHALL be placed on every other channelizing device along taper. Shadow Vehicle with ThtA and high intensity rotating, flashing, oscillating or strobe lights. (See notes 4 & 5) CW20-1D 36" X 36" (Flags-See Note 1) CW13-1P 24" X 24" (See Note 2) A. · CW8-11 36" X 36" ee Note 2).A. ' CW20-5TR HT 36" X 36" E ED, , I I CW16-9P �HEAD 24" X 18" OR END ROAD WORK G20-2 36" X 18" u X ..... ..... ..... n END I I /ROADWORK ◊. ◊36<i.2tf5• I • • • I• •• I· •• I· •• ,.,, • ..... ..... ..... b] • mu 0 � C �-� i �b �N cc :i C * X X X X l[M]I Shadow Vehicle with ThtA and high intensity rotating, flashing, oscillating or strobe lights. (See notes 4 & 5) CW20-1D 36" X 36" (Flags-See Note 1) CW13-1P 24" X 24" (See Note 2) .A. CW8-11 36" X 36" e Ncte 2)A. 11�11 ;�6;�: .. OR RIGHT LANE CLOSURE (5 LANE ROAD) RIGHT LANE CLOSURE ( 4 LANE BOULEVARD ROAD) NO. REVISIONS DATE NAME HARRIS COUNlY PUBLIC INFRASTRUCTURE DEPARTMENT ARCHITECTURE &: ENGINEERING DIVISION FOR INTERIM REVIEW ONLY DOCUMENT INCOMPLEIE: NOT INTENDED FOR C0NSIRIJCllON, BIDDING, OR PERMIT PURPOSES ENGINEER: NAME P.E. SERIAL No. NUMBER DAlE: / / TRAFFIC CONTROL PLAN SECTION SHALL BE COMPLETED BY ENGINEER SPACING POSlED TAPER CHANNELIZING SIGN BUFFER ROADWAY SPEED LENGTH DEVICES SPACING SPACE TAPER TANGENT LEGEND = Type 3 Barricade ••Channelizing Devices DP Heavy Work Vehicle tz§J Truck Mounted Attenuator (ThtA \ Trailer Mounted Portable Changeable i Flashing Arrow Board ® Message Sign (PCMS) ..... Sign ◊Traffic Flow °' Flag Uo Flogger Minimum Suggested Maximum Minimum Desirable Spacing of Suggested Posted Formula Taper �en.gths "L" Sign Speed Channelizing Spacing Longitudinal . Devices ·x· Buffer Space 10· 11' 12' On a On o Distance "B" Offset Offset Offset Taper Tangent 30 ws2 150' 165' 180' 30' 60' 120' 90' 35 205' 225' 245' 35' 70' 160' 120' -L= 60 265' 295' 40' 40 320' 80' 240' 155' 45 450' 495' 540' 45' 90' 320' 195' 50 500' 550• 600· 50' 100' 400' 240' 55 L=WS 550' 605' 660' 55' 110· 500" 295' -60 600' 660' 720' 60' 120' 600' 350' -65 650' 715' 780' 65' 130' 700' 410' 70 700' 770• 840" 70' 140" 800' 475' -75 750' 825' 900' 75' 150' 900' 540' *Conventional Roads Only ** Toper lengths have been rounded off. L=Length of Toper(FT) W=Width of Offset(FT) S=Posted Speed(MPH) GENERAL NOTES 1. Flags attached to signs where shown are OPTIONAL. 2. All traffic control devices illustrated are REQUIRED, except those denoted with the triangle symbol are OPTIONAL. 3. Inactive work vehicles or other equipment should be parked near the right-of-way line and not parked on the paved shoulder. 4. A Shadow Vehicle with a ThtA should be used anytime It can be positioned 30 to 100 feet in advance of the area of crew exposure without adversely affecting the performance or quality of the work. If workers are no longer present but road or work conditions require the traffic control to remain in place, Twe .3 Barricades or other channelizing devices may be substituted for the Shadow Vehicle and ThtA. 5. Additional Shadow Vehicles with ThtAs may be positioned off the paved surface, next to those shown in order to protect wider work spaces. 6. Contractor shall provide and install traffic control devices in conformance with part VI of Texas Manual on Uniform Traffic Control Devices (ThtUTCD -Latest edition with revisions) during construction. PROJECT TITLE: UNDERWOOD ROAD 45 450'45'320'90'195' MAK Design & Drafting LLCP.O.Box 940161 Houston, TX 77094Ph. # 713-298-0297 C-5