Loading...
HomeMy WebLinkAbout1301 S. 16th Page 4OFFICEWAREHOUSETOTAL1,772 SQ FT107,203 SQ FT108,975 SQ FTNOPARKING NOPARKINGNOPARKINGPROVIDE NEW EDGE OF DOCK LEVELER WHERE NOTED - COPPERLOYMECHANICAL 30K CAPACITYPROVIDE NEW PIT LEVELER WHERE NOTED - GENISYS ML986 MECHANICAL 30KCAPACITY - RE: STRUCTURALPROVIDE NEW EXHAUST FANS IN WAREHOUSE PER CODEW1W2WAREHOUSE KEY NOTESW3FIRE ALARM & DETECTION SYSTEMS - SPRINKLEREDEXISTING ALARM SYSTEM FOR MONITORING SPRINKLERS AND NOTIFYINGOCCUPANTS - SYSTEM TO COMPLY WITH NFPA 72WAREHOUSENON-ACOFFICE AREARE: 9/A2.02EXISTING RAMP EXISTING RAMP OPEN TO DECKW1W2W1W1W2W2W2W3EXISTING DOORREQUIRED EXITEXISTING DOORREQUIRED EXITEXISTING DOOREXISTING DOOREXISTING DOORREQUIRED EXITEXISTING DOOREXISTING DOOREXISTING DOORREQUIRED EXITEXISTING DOORREQUIRED EXITEXISTING DOORREQUIRED EXITEXISTING DOORREQUIRED EXITEXISTING DOORREQUIRED EXITEXISTING DOOREXISTING DOOREXISTING DOOR E-1LC E-1LC E-3LC E-3LC E-3LC E-3LC E-3LC E-3LC E-3LC E-3LC E-3LC E-3LC E-3LC E-3LC E-3LCMAX EXIT TRAVELDISTANCE 204 '-7"MAX EXIT TRAVELDISTANCE 211'-2"NOTE: DOOR IS AT GRADE. PROVIDE HANDICAPSIGNAGE AT INTERIOR AND EXTERIORDISPLAYING INTERNATIONAL SYMBOL ANDWORDING INDICATING ACCESSIBILITY. REFERTO CIVIL PLANS FOR SIDEWALKS AND LANDINGSAT GRADE. MAINTAIN SAME ELEVATION BOTHSIDES OF THRESHOLD PER IBC SECTION 1008.THRESHOLD MUST NOT EXCEED 1/2" IN HEIGHT.44'-3 1/8"40'-0 1/4" 305'-7 1/4"406'-0"DENOTES FIRE EXTINGUISHER LOCATIONS - MAXIMUM TRAVELDISTANCE TO EXTINGUISHER IS 75 FEETFIRE EXTINGUISHERSEMERGENCY EGRESS LIGHTING LEGENDNEW LED ILLUMINATED EXIT SIGNEXISTING EXTERIOR EGRESS LIGHTING (GC TO PROVIDE IF NOTEXISTING)INDICATES NEW WALLINDICATES NEW WALL WITH INSULATIONWALL LEGENDNEW LED 35,000 LUMEN HIGH BAY, SIX LAMP FIXTURE - TO BE MOUNTEDTO THE BOTTOM OF THE JOISTWAREHOUSE LIGHTING LEGEND2118 LAMAR ST., SUITE 200 HOUSTON, TEXAS 77003 (713)842 - 7500TL:DATE:PROJECT:SHEET:REVISIONS:DE:/SHEET:METHOD ARCHITECTURE, PLLC COPYRIGHT 2020 THESE DRAWINGS ARE THE PROPERTY OF METHOD ARCHITECTURE, LLC AND MAY NOT BE REPRODUCED, MODIFIED, NOR USED IN ANY WAY WITHOUT THE EXPRESSED WRITTEN PERMISSION OF METHOD ARCHITECTURE, PLLC. C111/10/20 REVISED PER PRICINGINFO212/03/20 ISSUED FOR REVIEW2026312/16/2020312/15/20 ISSUED FOR PERMIT412/16/20 ISSUED FOR PERMIT12/03/20A2.01DH1301 SOUTH 16TH STREET MAKE READY 1301 SOUTH 16TH STREET SUITE 100 LA PORTE, TEXAS 77571M202018AMOVERALL PLANAND NOTESNLOCATION PLAN1NOT TO SCALEFIRE NOTES4KEY NOTES3NOFFICE AND WAREHOUSE PLAN51/32" = 1'-0"LEGENDS2