Loading...
HomeMy WebLinkAbout2459+Underwood+FINALPRE-DEVELOPMENT DRAINAGE PLAN TOPO SURVEY CIVIL: COVER SHT. DRAWING NO. TITLE C-2.0 C-1.1 C-1.0 - SITE PLAN SWPPP PLAN C-3.1 SWPPP DETAILS LA PLAZA C-3.0 LA PORTE, TX 77571 2459 UNDERWOOD ROAD, LANDSCAPING PLAN DRAWING INDEX SCOPE OF WORK: PROPOSED GAS STATION WITH CANOPY, SHOPPING CENTER HOUSTON, TX 77094 P. O. BOX 940161 TEL: 713-298-0297 FAX: 281-239-2710 MAK Design & Drafting LLC JIN LEE OWNER CITY OF LA PORTE C-5.0 48 HOUR NOTICE: CONTRACTOR SHALL NOTIFY HARRIS COUNTY PRIOR TO COMMENCING CONSTRUCTION AND / OR BACKFILLING ANY UTILITIES. CONTRACTOR(S) TO CONTACT PUBLIC REVIEW DEPARTMENT @ (713-274-3931) OR PUBLIC.REVIEW@HCPCID.ORG C-2.1 DRAINAGE AREA MAP C-2.2 PROPOSED DRAINAGE PLAN C-1.3 C-1.2 PAVING PLAN SITE DETAILS C-2.3 DRAINAGE CALCULATIONS - PLAT - TRAFFIC CONTROL PLAN C-4.0 UTILITY PLAN C-4.1 DETAILS C-4.2 DETAILS C-4.3 DETAILS CBG TEXAS N PLAN SHEET C-1.0 TITLE PROJECT SITE HOUSTON, TX 77094 P.O.BOX 940161 TEL: 713-298-0297 FAX: 281-239-2710 201919 07-01-19 PROJECT NO. DATE SCALE 1 = 30- 0 JIN LEE OWNER MAK Design & NO ISSUE / REVISION DATE Drafting LLC MAK Engineering F-12117 LA PORTE, TX 77571 2459 UNDERWOOD RD. LA PLAZA NOTE: FUEL DISPENSING SHALL BE PROHIBITED WITHIN 25 FEET OF ANY SOURCE OF IGNITION (2018 IFC SECTION 5706.4.5(17)) City Approving Authority certificate: This is to certify that on ________day of _________, 20__ the City of La Porte, Texas, has approved this site plan and development of LA PLAZA in conformance with the ordinances of the City of La Porte. By: ______________________________ Director, Plannin g and Development ______________________________ City Planner _______________________________ City Engineer 16th June 21 This Drawing has been reviewed and found to be: in compliance not in compliance (see markups) -> RESUBMIT Approval of these plans does not relieve the contractor of responsibility of ensuring proper construction per City ordinances. Any deviation from approved plans must be submitted to the City for review and approval prior to construction. Date: ________________ By: 6/22/2021 X CBG TEXAS N PLAN SHEET C-1.1 TITLE PROJECT LANDSCAPING HOUSTON, TX 77094 P.O.BOX 940161 TEL: 713-298-0297 FAX: 281-239-2710 201919 07-01-19 PROJECT NO. DATE SCALE 1 = 30- 0 JIN LEE OWNER MAK Design & NO ISSUE / REVISION DATE Drafting LLC MAK Engineering F-12117 LA PORTE, TX 77571 2459 UNDERWOOD RD. LA PLAZA CBG TEXAS N PLAN SHEET C-1.2 TITLE PROJECT PAVING HOUSTON, TX 77094 P.O.BOX 940161 TEL: 713-298-0297 FAX: 281-239-2710 201919 07-01-19 PROJECT NO. DATE SCALE 1 = 30- 0 JIN LEE OWNER MAK Design & NO ISSUE / REVISION DATE Drafting LLC MAK Engineering F-12117 LA PORTE, TX 77571 2459 UNDERWOOD RD. LA PLAZA SITE 4 1/2"   ... CEMENT CONCRETE, 5 SACK CEMENT PER CUBIC YARD, 7 INCHES PROPERTY, SAID DRIVEWAYS SHALL BE SEPARATED BY A MINIMUM 10. IF MORE THAN ONE PROPOSED DRIVEWAY IS BUILT ON THE SAME DISTANCE OF 20 FEET (ROADWAYS WITH CURBS AND SIDEWALKS). SUBGRADE. (3 INCHES MANUFACTURED CHAIRS ARE REQUIRED WITH 11. REINFORCING STEEL TO BE ELEVATED A MINIMUM OF 3" ABOVE MAXIMUM SPACING OF 72 INCHES C/C EACH WAY). THICK, FROM PROPOSED SAW CUT TO RIGHT-OF-WAY LINE LAP (6"x12" W5xW4 AS ALTERNATE) FROM PROPOSED SAW CUT SPACED AT 24 INCHES C.C., EACH WAY, WITH 10 INCHES MINIMUM 4. PROPOSED DRIVEWAY REINFORCING STEEL IS TO BE #4 DEFORMED EXISTING ROADWAY REINFORCING STEEL WITH A MINIMUM LAP 5. PROPOSED DRIVEWAY REINFORCING STEEL IS TO BE TIED TO 6. PROPOSED GUTTER LINE IS TO BE MAINTAINED AT FACE OF 7. SAW CUT EXISTING CURB AT EACH END AND KNOCK OUT CURB FROM BEGINNING TO END OF PROPOSED DRIVEWAY. FROM FACE OF CURB (GUTTER LINE) AND BREAK OUT TO EXPOSE 8. SAW CUT EXISTING PAVEMENT A MINIMUM OF 12 INCHES AWAY PROPOSED SAW CUT AT EXISTING PAVEMENT TO RIGHT-OF-WAY 9. COMPACT SUBGRADE FOR PROPOSED DRIVEWAY CONNECTION FROM LINE, COMPACT TO 95% OF STANDARD PROCTOR DENSITY (+/- 2% OPT. MOISTURE). THE COUNTY ENGINEER RESERVES THE RIGHT TO REQUIRE LABORATORY TESTS TO BE CONDUCTED. (PROPERTY LINE). TO RIGHT-OF-WAY LINE. OF 8 INCHES. EXISTING CURB. EXISTING REINFORCEMENT STEEL. 1. PROPOSED DRIVEWAY, SIDEWALK, CURB, GUTTER LINE AND GRADE 2. PROPOSED SIDEWALK SHALL BE CONSTRUCTED WITH PORTLAND 3. PROPOSED DRIVEWAY SHALL BE CONSTRUCTED WITH PORTLAND CEMENT CONCRETE, 4-1/2 SACK CEMENT PER CUBIC YARD, 4-1/2 INCHES THICK AND 4 FEET MINIMUM WIDTH. SEE DRAWING NO.3 FOR ADDITIONAL INFORMATION AND DETAILS. SHALL MATCH EXISTING STREET. GENERAL NOTES: R.O.W. LINE 18" STANDARD (SEE GENERAL NOTE NO.7) 3" CLEARANCE (TYP.) 7" THICK REINFORCED CONCRETE 3" CLEARANCE 12" 6" PAVEMENT CUT UNDER EXISTING 6" 24" NEW PAVEMENT EXISTING PAVEMENT GUTTER LINE 8" STEEL OVERLAP 12" PROP. SAW CUT PREFORMED JOINT MAK Design & Drafting LLC MAK Engineering F-12117 CBG TEXAS N 0.18 A-11 0.15 A-3 0.15 A-5 0.18 A-6 0.19 A-4 0.22 A-8 0.17 A-9 0.20 A-10 0.19 0.17 A-1 A-2 0.19 A-7 ACREAGE DRAINAGE AREA AREA MAP SHEET C-2.1 TITLE PROJECT DRAINAGE HOUSTON, TX 77094 P.O.BOX 940161 TEL: 713-298-0297 FAX: 281-239-2710 201919 05-25-20 PROJECT NO. DATE SCALE 1 = 30- 0 JIN LEE OWNER MAK Design & NO ISSUE / REVISION DATE Drafting LLC MAK Engineering F-12117 LA PORTE, TX 77571 2459 UNDERWOOD RD. LA PLAZA Δ Δ Δ BOP AREA 4913 S.F. GUY WIRE OHP OHP 10.0' 10.0' 21.0' √ STM STM STM ST M STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM S TM STM STM STM STM STM STM STM ST M STM STM STM STM STM STM STM S TM STM STM STM STM STM STM STM ST M STM STM STM STM STM STM STM STM STM S TM STM STM STM STM STM STM STM ST M STM STM STM STM STM STM STM S TM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM S TM STM STM STM STM STM STM STM S TM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM ST M STM STM STM STM STM STM STM STM S TM STM STM STM STM STM STM STM ST M STM STM STM STM STM STM STM STM STM STM STM STM STM STM PROP. 90 LF 24" Ø PVC @ 0.20% SLOPE BOP ELEV. 17.0 TC 26.75 TC 26.25 TC 26.75 TC 26.75 TC 26.75 TC 26.75 8100 S.F. TP 25.75 TP 25.75 TP 25.75 TP 25.75 TP 25.75 TP 25.75 TP 25.75 TP 25.75 TP 25.75 TP 25.75 TC 26.25 TP 25.75 TC 26.25 TP 25.75 TC 26.25 TP 25.75 TC 26.25 TP 25.75 TC 26.25 TP 25.75 I = b (d + Tc)e Tc = 10A 0.1761 + 15 RAINFALL INTENSITY : INITIAL TIME OF CONCENTRATION: VELOCITY V = 1.49 n R 2/3 S1/2 PIPE DISCHARGE Q = VA WHERE, A = D 4  2 CALCULATIONS SHEET C-2.3 TITLE PROJECT DRAINAGE HOUSTON, TX 77094 P.O.BOX 940161 TEL: 713-298-0297 FAX: 281-239-2710 PROJECT NO. DATE SCALE N.T.S. OWNER MAK Design & NO ISSUE / REVISION DATE Drafting LLC MAK Engineering F-12117 1. STORM SEWER PIPE USE FOR CONNECTION TO STORM SEWER IN PUBLIC R.O.W. SHALL BE REINFORCED CONCRETE PIPE ASTM C-76, CLASS III, WITH RUBBER GASKET PER ASTM C-443 AND SHALL EXTEND TO FIRST INLET OR MANHOLE. ALL OTHER PRIVATE STORM SEWER MAY BE H.D.P.E. OR APPROVED EQUAL. 2. STORM SEWER SHALL BE CONSTRUCTED IN ACCORDANCE WITHTHE LATEST HARRIS COUNTY STANDARD CONSTRUCTION SPECIFICATIONS FOR STORM DRAINAGE INCLUDING ALL CURRENT AMMENDMENTS THERETO. 3. ALL SEWER UNDER PROPOSED OR FUTURE PAVEMENT AND TO POINT ONE (1) FOOT BACK OF ALL PROPOSED OR FUTURE CURBS SHALL BE BACKFILLED WITH 1 1 2 SACK CEMENT/C.Y. STABILIZED SAND TO WITHIN ONE (1) FOOT OF SUBGRADE. CEMENT STABILIZED SAND TO BE IN ACCORDANCE WITH THE REQUIREMENTS OF ASTM C 33, LATEST EDITION. RUN OFF Q A = CIA DETENTION PROVIDED : PARKING LOT DETENTION STORAGE VOLUME PROVIDED =0.7 AC-FT DETENTION SUMMARY TOTAL IMPERVIOUS AREA = 2.41 ACRE = 105,026 SF EXISTING PERVIOUS AREA = 0 DETENTION VOLUME REQUIRED = 2.23 AC X 0.75 AC-FT/AC PROPOSED BUILDING 20,040 S.F. FUTURE LAND DEVELOPMENT = 0 DETENTION RATE = 0.75 AC-FT/AC = 1.7 AC-FT TOTAL DETENTION STORAGE VOLUME PROVIDED = (0.7 + 1.7) AC-FT= 1.7 AC-FT DETENTION POND STORAGE VOLUME PROVIDED = 1.0 AC-FT TOTAL DETENTION STORAGE VOLUME PROVIDED = TOTAL DETENTION STORAGE VOLUME REQUIRED 24" PVC 6" PVC PIPE RESTRICTOR NOTE: 1. RESTRICTOR PIPE SHALL BE GROUTED IN PLACE FROM END TO END. CBG TEXAS N MYRTLE CREEK DRIVE UNDERWOOD ROAD NOTE: 1. WORK THIS DRAWING WITH HARRIS COUNTY PAVEMENT CNST & MARK DET. DRAWING STABILIZED CONSTRUCTION EXIT INLET PROTECTION BARRIER (IPB) LEGENDS: PROPOSED INLET SC FILTER FABRIC FENCE WORK THIS DRAWING WITH SITE PLAN FOR DETAILS. NOTE: (STAGE I AND STAGE II PROTECTION REQUIRED) 2. ALL INLETS IN PROPOSED PAVED AREA NEEDS STAGE I AND STAGE II INLET PROTECTION. IPB IPB IPB IPB IPB IPB IPB IPB IPB IPB SC SC PLAN SHEET C-3.0 TITLE PROJECT SWPPP HOUSTON, TX 77094 P.O.BOX 940161 TEL: 713-298-0297 FAX: 281-239-2710 201919 05-25-20 PROJECT NO. DATE SCALE 1 = 30- 0 JIN LEE OWNER MAK Design & NO ISSUE / REVISION DATE Drafting LLC MAK Engineering F-12117 LA PORTE, TX 77571 2459 UNDERWOOD RD. LA PLAZA Δ Δ Δ CBG TEXAS N “ ” – “ ” “ ” ’ “ ” ’ PLAN SHEET C-4.0 TITLE PROJECT UTILITY HOUSTON, TX 77094 P.O.BOX 940161 TEL: 713-298-0297 FAX: 281-239-2710 201919 07-01-19 PROJECT NO. DATE SCALE 1 = 30- 0 JIN LEE OWNER MAK Design & NO ISSUE / REVISION DATE Drafting LLC MAK Engineering F-12117 LA PORTE, TX 77571 2459 UNDERWOOD RD. LA PLAZA DETAILS SHEET C-4.1 TITLE PROJECT PROJECT NO. DATE SCALE N.T.S. OWNER NO ISSUE / REVISION DATE HOUSTON, TX 77094 PO BOX 940161 TEL: 713-298-0297 FAX: 281-239-2710 MAK Design & Drafting LLC 201918 JIN LEE 03-15-21 LA PLAZA LA PORTE, TX 77571 2459 UNDERWOOD ROAD DETAILS SHEET C-4.2 TITLE PROJECT PROJECT NO. DATE SCALE N.T.S. OWNER NO ISSUE / REVISION DATE HOUSTON, TX 77094 PO BOX 940161 TEL: 713-298-0297 FAX: 281-239-2710 MAK Design & Drafting LLC JIN LEE 03-15-21 201918 LA PLAZA LA PORTE, TX 77571 2459 UNDERWOOD ROAD MAK Engineering F 12117 SIDE VIEW PLAN VIEW INLET FROM INTERCEPTOR OUTLET TO SEWER JOINT SEALED w/ NONSHRINK GROUT JOINT SEALED w/ NONSHRINK GROUT FRONT VIEW DETAILS SHEET C-4.3 TITLE PROJECT PROJECT NO. DATE SCALE N.T.S. OWNER NO ISSUE / REVISION DATE HOUSTON, TX 77094 PO BOX 940161 TEL: 713-298-0297 FAX: 281-239-2710 MAK Design & Drafting LLC JIN LEE 03-15-21 201918 LA PLAZA LA PORTE, TX 77571 2459 UNDERWOOD ROAD MAK Engineering F 12117 36" CW20-X 36" 1D (Flags-See Note 1) Chevron SHALL be Alignment placed on (CW every 1-8L) other signs channelizing device along taper. END X ROADWORK\ 36" G20-X 18" 2 ◊ I ◊ I I . I I I I I I I I I I I I I I I I I I I I I I I I o!o ROAD END WORK I 36" G20-X 18" 2 I • • • •• I• •• I· •• I· I· ...J • * X ..... X ..... X ..... X 36" CW20-X 36" 1D (Flags-See Note 1) Chevron SHALL be Alignment placed on (CW every 1-8L) other signs channelizing device along taper. intensity Shadow Vehicle rotating, with flashing, ThtA and high (oscillating See notes or 4 strobe & 5) lights. 36" CW20-X 36" 1D (Flags-See Note 1) (See 24" CW13-Note X 24" 1P 2) A. · CW8-11 36" ee Note X 36" 2).A. ' CW20-5TR HT 36" X 36" E ED, , I I �HEAD CW16-24" X 9P 18" OR END ROAD WORK 36" G20-X 18" 2 u X ..... ..... ..... n END I ◊ . I ◊ /ROADWORK 36<i.2tf5• I • • • •• I• •• I· •• I· ,.,, • ..... ..... ..... b] • 0 �-mu � � i C �b �N cc :i C * X X X X l[M] I intensity Shadow Vehicle rotating, with flashing, ThtA and high oscillating (See notes or 4 strobe & 5) lights. 36" CW20-X 36" 1D (Flags-See Note 1) (See 24" CW13-Note X 24" 1P 2) .A. 36" CW8-X 36" 11 e Ncte 2)A. 11�11 ;�6;�: .. OR RIGHT LANE CLOSURE (5 LANE ROAD) RIGHT LANE CLOSURE ( 4 LANE BOULEVARD ROAD) NO. REVISIONS DATE NAME HARRIS COUNlY PUBLIC INFRASTRUCTURE DEPARTMENT ARCHITECTURE &: ENGINEERING DIVISION FOR INTERIM REVIEW ONLY DOCUMENT INCOMPLEIE: NOT INTENDED FOR C0NSIRIJCllON, BIDDING, OR PERMIT PURPOSES ENGINEER: NAME P.E. SERIAL No. NUMBER DAlE: / / TRAFFIC CONTROL PLAN SECTION SHALL BE COMPLETED BY ENGINEER SPACING POSlED TAPER CHANNELIZING SIGN BUFFER ROADWAY SPEED LENGTH DEVICES SPACING SPACE TAPER TANGENT LEGEND = Type 3 Barricade •• Channelizing Devices DP Heavy Work Vehicle tz§J Attenuator Truck Mounted (ThtA \ Trailer Mounted Portable Changeable i Flashing Arrow Board ® Message Sign (PCMS) ..... Sign ◊ Traffic Flow °' Flag Uo Flogger Desirable Minimum Suggested Spacing Maximum of Minimum Suggested Posted Formula Taper � en.gths "L" Sign Speed Channelizing Spacing . Devices ·x· Buffer Longitudinal Space 10· 11' 12' On a On o Distance "B" Offset Offset Offset Taper Tangent 30 ws2 150' 165' 180' 30' 60' 120' 90' -40 35 L= 60 265' 205' 225' 295' 320' 245' 35' 40' 80' 70' 160' 240' 120' 155' 45 450' 495' 540' 45' 90' 320' 195' 50 500' 550• 600· 50' 100' 400' 240' --55 60 65 L=WS 650' 600' 550' 715' 660' 605' 720' 660' 780' 60' 55' 65' 110· 120' 130' 600' 500" 700' 410' 350' 295' -70 75 700' 750' 770• 825' 840" 900' 70' 140" 800' 475' 75' 150' 900' 540' * Conventional Roads Only ** Toper lengths have been rounded off. L=Length of Toper(FT) W=Width of Offset(FT) S=Posted Speed(MPH) GENERAL NOTES 1. 2. the Flags All traffic triangle attached control symbol to devices signs are OPTIONAL. where illustrated shown are are REQUIRED, OPTIONAL. except those denoted with 3. right-Inactive of-work way line vehicles and or not other parked equipment on the paved should shoulder. be parked near the 4. to A Shadow 100 feet Vehicle in advance with a of ThtA the should area of be crew used exposure anytime without It can adversely be positioned affecting 30 Barricades the road performance or work or conditions other or channelizing quality require of the the devices work. traffic may If control workers be substituted to are remain no longer for in place, the present Shadow Twe but .3 5. Vehicle Additional and Shadow ThtA. Vehicles with ThtAs may be positioned off the paved surface, 6. next Contractor to those shall shown provide in order and install to protect traffic wider control work devices spaces. in conformance with edition part VI with of Texas revisions) Manual during on Uniform construction. Traffic Control Devices (ThtUTCD - Latest PROJECT TITLE: UNDERWOOD ROAD 45 450' 45' 320' 90' 195' MAK Design & Drafting LLC P.O.Box 940161 Houston, TX 77094 Ph. # 713-298-0297 C-5   2 OUTFLOW RESTRICTOR DESIGN: PREDEVELOPMENT PEAK FLOW TOTAL EASEMENT AREA = 7,700 S.F. 201410 05-25-20 JIN LEE LA PLAZA LA PORTE, TX 77571 2459 UNDERWOOD RD. TOTAL OUTFALL RATE FOR PROPOSED PROPERTY = 5.40 DRAINAGE ANALYSIS 2 - YEAR STORM EVENT STORM SEWER CALCULATION (PROPOSED PROPERTY) AREA PIPE RUN FROM TO RUN-OFF TOTAL AREA (AC) RUN-OFF AREA (AC) DRAINAGE "A" "A" A-2 I I A-3 A-6 2 4 I3 I6 0.17 0.36 0.15 0.15 0.16 0.30 I4 A-5 I5 I 0.14 0.14 6 A-7 I I A-9 7 8 I9 0.19 0.49 0.22 1.41 POND 0.19 1.77 I9 A-10 I10 I7 A-1 I1 0.19 0.19 A-4 I4 I8 0.19 0.70 A-8 I8 I10 0.17 1.58 A-11 POND 0.18 1.95 CONCENT. CO-EFF. RUN-OFF T (MIN) "C" I (IN.) Q (CFS) TIME OF C RAIN FALL INTENSITY TOTAL RUN-OFF A Q A (CFS) MANNING PIPE DIAM. LENGTH "n" (IN) (LF) REACH 0.01 (S) SLOPE % 0.01 0.01 128 49 85 0.01 50 0.01 0.01 0.01 60 130 80 0.01 95 0.01 94 0.01 90 VELOCITY R (FT) V (FT/SEC) "Q" HYDRAULIC RADIUS 2.86 DISCHARGE (CFS) PIPE 18.18 2.86 2.86 2.86 5.19 8.44 2.86 DISCHARGE OK 5.19 18.18 18.18 10 - YEAR STORM EVENT RUN-OFF I (IN.) Q (CFS) RAIN FALL INTENSITY TOTAL RUN-OFF Q (CFS) 0.63 1.42 A A 0.59 0.59 0.63 1.18 0.55 0.55 0.75 1.93 0.86 5.55 0.75 0.75 0.75 2.76 5.2 5.3 5.3 5.2 5.3 3.5.7 3 5.2 5.2 100 - YEAR STORM EVENT RUN-OFF I (IN.) Q (CFS) RAIN FALL INTENSITY TOTAL RUN-OFF Q (CFS) 0.93 1.97 A A 0.83 0.83 0.88 1.65 0.77 0.77 1.04 2.69 1.20 7.73 1.04 1.04 1.04 3.84 7.3 22.3 7.3 22.2 22.2 22.1 22.5 22.5 22.5 22.5 22.3 22.5 22.4 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 0.46 0.41 0.43 0.38 0.51 0.59 0.51 0.51 0.51 0.46 0.49 0.97 0.41 0.81 0.38 1.32 3.80 4.91 0.51 1.89 4.40 5.40 0.25 0.50 0.25 0.25 0.31 0.25 0.25 0.31 0.38 0.50 0.50 3.6 3.6 3.6 3.6 4.2 4.8 5.8 3.6 4.2 5.8 5.8 12" 24" 12" 12" 12" 15" 18" 12" 15" 24" 0.01 24" 47 0.20 0.67 6.22 0.75 6.97 0.71 7.68 5.3 5.2 5.2 0.93 8.66 1.04 9.70 0.99 10.69 I2 DISCHARGE OK DISCHARGE OK DISCHARGE OK DISCHARGE OK DISCHARGE OK DISCHARGE OK DISCHARGE OK DISCHARGE OK DISCHARGE OK DISCHARGE OK 7.3 7.3 7.4 7.3 7.3 7.3 7.3 7.3 7.3 AREA PROPERTIES PIPE PROPERTIES 2 YRS 10 YRS 100 YRS b d e 75.01 93.53 125.4 16.2 18.9 21.8 0.8315 0.7742 0.7500 FROM EXHIBIT 3-1 AND 3-2 HCFCD MANUAL DRAINAGE AREA = 2.23 ACRE IMPERVIOUS COVER 0% PREDEVELOPMENT PEAK FLOW : FOR 2 YRS = 1.8 CFS 10 YRS = 3.0 CFS 100 YRS = 4.8 CFS --- OUTFALL 0.18 1.95 22.4 0.75 0.01 24" 45 0.38 0.50 5.8 3.6 0.49 5.40 18.18 5.2 0.71 7.68 0.99 10.69 DISCHARGE OK 7.3 I11 I11 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 TC 26.25 TP 25.75 TC 26.25 TP 25.75 TC 26.25 TP 25.75 TC 26.25 TP 25.75 TC 26.75 TP 25.75 TC 26.25 TP 25.75 TC 26.25 TP 25.75 TC 26.25 TP 25.75 TP 25.75 TP 26.25 TP 25.75 TC 26.25 TP 25.75 STEP STEP STEP STEP STEP STEP STEP PROP. 85 LF 12" Ø PVC @ 0.20% SLOPE PROP. 60 LF 15" Ø PVC @ 0.20% SLOPE PROP. 130 LF 18" Ø PVC @ 0.20% SLOPE PROP. 80 LF 24" Ø PVC @ 0.20% SLOPE PROP. 95 LF 12" Ø PVC @ 0.20% SLOPE PROP. 128 LF 12" Ø PVC @ 0.20% SLOPE PROP. 49 LF 12" Ø PVC @ 0.20% SLOPE PROP. 94 LF 15" Ø H.D.P.E. @ 0.20% SLOPE PROP. 50 LF 12" Ø PVC @ 0.20% SLOPE PROP. 47 LF 24" Ø RCP @ 0.20% SLOPE PARKING LOT CROSS SECTION (TYP.) NOTE: FLOW LINE PARKING LOT CROSS SECTION (TYP.) 0.75' BLDG. WALL F.F. ELEV. 27.00 TC 26.25 PROP.BB-I7 TOP 25.00 FL -- 19.89 SIDE WALK TP 25.75 TC 26.25 TP 25.75 EL 26.75 MAX. WATER SURFACE ELEVATION 25.75 STEP TC 26.25 TP 25.75 TC 26.25 TP 25.75 TC 26.25 TP 25.75 STEP TC 26.75 TC 26.75 TC 26.25 TP 25.75 0.15 A-3 0.14 A-5 0.16 A-6 0.19 A-4 0.22 A-8 0.17 A-9 0.19 A-10 0.19 A-1 0.17 A-2 0.18 A-11 0.19 A-7 6" RESTRICTOR DETENTION POND CROSS SECTION (TYP.) SCALE: N.T.S. 1'-0" FREEBOARD PROP. 45 LF 24" Ø RCP @ 0.38% SLOPE MAK Design & Drafting LLC MAK Engineering F-12117 OR 1/2" NON-EXTRUDING 1" BOARD EXPANSION #4 @ 24" C/C COMPACT SUBGRADE TO 95% STANDARD PROCTOR DENSITY EXIST. CURB BACK OF 4' MINIMUM 2' NON-EXTRUDING PREFORMED JOINT 1" BOARD EXPANSION OR 1/2" 1:50 MAX CROSS SLOPE DETAILS C-1.3 SHEET TITLE PROJECT HOUSTON, TX 77094 P.O.BOX 940161 TEL: 713-298-0297 FAX: 281-239-2710 PROJECT NO. DATE SCALE N.T.S. OWNER MAK Design & NO ISSUE / REVISION DATE Drafting LLC MAK Engineering F-12117 JIN LEE 201410 05-25-20 LA PLAZA LA PORTE, TX 77571 2459 UNDERWOOD RD.