Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
101 E MAIN ST_06-0398___________
101 E MAIN CLP # 06-8207 RESTAURANT (BAR •& GRILL) City of La Porte Established 1892 Customer Service Inspection Certificate Name ofPWS C,l I Y PWSLD.#_to1001R Location of Service i Reason for Inspection: New construction ..................................... . ........ 4J/ Existing service where contaminant honrds are suspected .............. ❑ Major renovation or expansion of distribution facilities ................. ❑ I R.T. L * a� /�-T-a I— upon inspection of the private water distribution facilities connected to the aforementioned p Iic water supply do hereby certify that, to the best of my knowledge: . (1) No direct connection between the public drinking water supply and a potential source of Campaarca NonCunpnaam contamination exists. Potential sources of contamination are isolated fmmthe public water ❑ system by an air gap or an appropriate backflow prevention assembly in accordance with ^� Commission regulations. (2) No cross -connection between the public drinking water supply and a private water system ❑ exists. Where an actual air gap is not maintained between the public water supply and a private water supply, an approved reduced pressure -zone backflow prevention assembly is properly installed and a service agreement exists for annual inspection and testing by a certified backflow prevention assembly tester. (3) No connection exists which would allow the return of water used for condensing, cooling ❑ or industrial processes back to the public water supply. / (4) No pipe or pipe fitting which contains more than 8.0% lead exists in private water O" ❑ distribution facilities installed on or after July 1, 1988. — / (5) No solder or flux which contains more than 02% lead exists in private water distribution y' ❑ facilities installed on or after July I, 1988. I further certify that the following materials were used in the installation of the private water distribution facilities: Service lines Lead ❑ Copper PVC ❑ Other ❑ Soldcr Lead ❑ Lead Free Solvent Weld ❑ Other ❑ I recognize that this document shall become a permanent record of the aforementioned Public Water System and that I am legally responsible for the validity of the information I have provided. Signature oflnspector Lv /N<4rLTer Titl Date Registration Number Jr19A 114 vML Type of Registration r, n,I.m Tw,a^.7;77_Ill; . n91).171_;MII Rev 12/00 Final Inspection Chick Sheet Commercial" } Date: 317 0�� Project Address: 101 -fJ 2 i /N Contractor Name: / -e U-1 Ii�, . o n C Project Name: /' l/ / w' File Review Ws 1-9 1. Final Flood Plain Elevation Certificate (if applicable) in file 2. Form Survey (if applicable) in file dit 3. Zoning Permit in file 4. Customer Service Inspection Certificate in file N�5. Back Flow Prevention Device Test Certificates (bldg & irrigation) in file 6. Energy Code final certificate in file ✓ 7. Fire Marshal building release in file ✓ . All required permits in file 9. All inspections on log complete Field Review Ws 10-17 �P- _10. Address # visible from street I I. Sign Permit in file & in compliance (if applicable) _AAA 12. Sidewalk construction (if applicable) as per site plan /v�13. Drainage as per site plan p./r7 14.. T-Pole removed _A,A�, 15. Fence (if applicable) in compliance ._&PO -16. Landscaping as per site plan 17. Inspection ticket to identify if full of temp 30-day CO is authorized I pector signature Date SACPShveV NSPECITON DMSIONUnspecli mX tnal rnspeetion Check ShcetComNovO4.doc i.. Lew Wiggs General Construction 11709 L Plainbroob LaPorte, Texas 77571 281 471 0717 932 %9 7360 July 7.2006 City of LaPorte Inspections Department Attn. Building Official Re. Main 101 Grill and Bar R E C F.IIVIF-IQ JM 7 - M This letter is to notify you that we have terminated our relationship with Trinidad Garza dba Anson Concepts as the electrician of record on our project at 101 E. Main in La Porte. We will soon issue a contract with a new electrician who will take out a new permit. If you have any questions please contact me. Sincere Lew Wiggs cc. Trinidad Garry Lew Wiggs, Gen. Construction 11709 E. Plainbrook LaPorte, Tx. 77571 City of LaPorte • Inspections Department Attn. Building Official (281)470-5073 ----------------------- Application Number Property Address HCAD Number . . . City of La Porte 604 W Fairmont Pkv0 La Porte, Tx 77571 INSPECTION LINE: (281)470-5130 ****ZONING PERMIT**** ---------------------------- . . . . 05-00001745 . . . . 101 E MAIN ST UB . . . . 023-256-081-0002 Application type description ZONING PERMIT Subdivision Name . . . . . . LA PORTE Property Use . . . . . . . . Property Zoning . . . . . . . MAIN STREET DISTRICT Property owner . . . . . . . PARKER THOMAS E & BETTY Owner address . . . . . . . . 717 YALE LN DEER PARK TX ---------------- Date 3/17/06 J 775366209 Other struct info . . . . . SIC CODE (ZONING PERMITS) X ---------------------------------------------------------------------------- Permit . . . . . . ZONING PERMIT Additional desc . . SIC # 5812 EATING & DRINKING Permit Fee . . . . 25.00 Issue Date . . . . 11/21/05 Valuation . . . . 0 Expiration Date . . 5/20/06 Qty. Unit Charge Per BASE FEE Extension 25.00 ---------------------------------------------------------------------------- Special Notes and Comments SIC # 5812 MAIN 101 GRILL & BAR 1. MUST BE INSPECTED & APPROVED BY CITY INSPECTOR & FIRE MARSHALL PRIOR TO OCCUPANCY 2. PERMIT MUST BE OBTAINED FOR ANY PROPOSED INTERIOR MODIFICATIONS FOR RESTAURANT/BAR OCCUPANCY 3. EXTERIOR MODIFICATIONS MAY NEED PRIOR APPROVAL BY CITY PLANNER PRIOR TO COMMENCING WORK 4. COORDINATE WITH CITY SECRETARY OFFICE REGARDING REQUIRD ALCOHOL PERMIT 5. RESTAURANT WILL REQUIRE HEALTH PERMIT FROM HARRIS COUNTY HEALTH DEPT PRIOR TO OPENING 6. ADEQUATE ON -SITE PARKING IS REQUIRED;PERMITS WILL BE REQUIRED FOR ANY FUTURE PARKING LOT DEVELOPMENT..INSP ECTION PASSED 11-22-2005 - JVL;FAXED ON 2-22-2006 PER JAMES @ 11:00 A.M.;CLOSED 2-22-2006 - JR. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due -------------------- ------------------------------------- Permit Fee Total 25.00 25.00 .00 .00 Grand Total 25.00 25.00 .00 .00 ---------------------------------------------------------------------------- THIS PERMIT BECOMES INVALID WITH ANY CHANGE OF USE, OCCUPANCY, TENANCY OR OWNERSHIP OF THIS BUILDING OR LEASE SPACE. OWNER OR AGENT _DATE ZONING ADMINISTRATOR DATE City of La Porte I 604 W Fairmont Pkwy` '� � - La Porte, Tx 77571 (281)470-5073 INSPECTION *LINE: (281)470- 3 --'****ZONING PERMIT -------------------------- Application Number . . . . 05-00001745 Date 11/21/05 Property Address . . . . 101 E MAIN ST UB HCAD Number . . . . . . . . `-023-256-081-0002 Application type description —ZONING PERMIT Subdivision Name . . . . . . LA PORTE Property Use . . . . . . . . _ --.TRICTCO V rC LAy - Property Zoning . . . . . . `MAIN STREET DI S Property owner . . . . . . . PARKER THOMAS'-E &'BETTY J Owner address . . . . . . . . 717 YALE LN DEER PARK TX 775366209 Otter struct info . . . . . SIC CODE (ZONING PERMITS) X -------------------------------------------------------------- Permit . . . . . . ZONING PERMIT Additional desc SIC # 5813 DRINKING PLACES Permit Fee -Issue eu D_ate 11/21/05�� Valuation . . . . 0 Expiration Date . �5/20/06 Qty Unit Charge Per Extension BASE FEE 25.00 ---------------------------------------------------------------- Special SIC # 5 Lli TOINSPECTO& OCCUPANCY 2. PERMIT MUST BE OBTAINED FOR. -ANY -PROPOSED INTERIOR MODIFICATIONS_ ,FOR RESTAURANT/BAR OCCUPANCY 3. EXTERIOR MODIFICATIONS MAY NEED PRIOR • APPROVAL BY CITY PLANNER PRIOR TO 'COMMENCING WORK__4. COORDINATE WITH CITY SECRETARY OFFICE REGARDING REQUIRD ALCOHOL PERMIT 5. RESTAURANT WILL REQUIRE HEALTH PERMIT FROM HARRIS COUNTY HEALTH DEPT PRIOR TO OPENING 6.- ADEQUATE ON -SITE PARKING IS -REQUIRED;PERMITS WILL BE REQUIRED FOR ANY FUTURE PARKING LOT DEVELOPMENT. Fee summary Charged Paid Credited Permit Fee Total 25.00 25.00 .00 and Total 25.00 25.00 .00 Due ---------- .00 .00 THIS PERMIT BECOMES INVALID WITH ANY CHANGE OF USE, Cr' OCCUPANCY, TENANCY OR OWNERSHIP OF THIS BUILDING OR LEASE SPACE. LL;p-v OWNER OR AGE _DATE J� ZONING ADMI TOR DATE HCAD Detail Sheet Page 1 of I Thursday, March 02, 2006 HARRIS COUNTY APPRAISAL DISTRICT Tax Year: 2006 I- REAL PROPERTY ACCOUNT INFORMATION print E-mail Ownership History I Related Accounts >, Owner and Property Information Owner Name & SALTERRY INC Legal Description: LTS 22 THRU 26 ELK 181 /�i"-'!/ • Mailing Address: 2005 YORKTOWN CT LA PORTE Lo 75 SEABROOK TX 77586 Property Address: 101 E MAIN ST LA PORTE TX 77571 State Class Code Land Use Code / F1 -- Real, Commercial 4339 -- Parking Miscellaneous 111 Land Area Building Area Neighborhood Map Facet Key Map 15,625 SF 0 9703.05 6254D 540Y Value Status Information Capped Account Value Status ARB Status Shared CAD Pending All Values Pending Pending No Exemptions and Jurisdictions Exemption Type Districts Jurisdictions 2005 Rate 2006 Rate Online Tax Bill None 020 LA PORTE ISO 1.73350 040 HARRIS COUNTY 0.39986 View 041 HARRIS CO FLOOD CNTRL 0.03322 042 PORT OF HOUSTON AUTHY 0.01474 043 HARRIS CO HOSP DIST 0.19216 044 HARRIS CO EDUC DEPT 0.00629 047 SAN JACINTO COM COL D 0.14536 071 CITY OF LAPORTE 0.71000 Valuations 2005 Value 2006 Value Market Appraised Market Appraised Land 15,625 Land Improvement 3,000 Improvement Total 18,625 18,625 Total Pending Pending 5-Year Value History Building Vacant (No Building Data) http://www.hcad.org/records/details.asp?tab=1&bid=1&card=l&taxyear=2006&acct=0232560810022 3/2/2006 COMMERCIAL PLAN REVIEW NOTES 1. Call for City inspections - 281-470-5130. 2. Unload and keep materials on private property, not City right of wa®v 3. If a fence is proposed, verify with City regarding maximum height limitations. 4. Call for utility line locates at 1-800-669-8344 and also City of La Porte at 281-471-9650 for water and sewer lines. 5. Fire Marshal will need to review/ inspect prior to opening business. 6. Must obtain zoning permit prior to occupancy of lease space/building. 7. Separate permit required for all signage. 8. Sanitation facilities required on -site prior to first inspection and must remain available until completion of sanitation facilities within the lease space and/or building. 9. Silt fencing required for duration of project. 10. See notes (red lined) on contractor copy of construction drawings. 11. Fill dirt permits are required prior to placement of fill dirt. 12. Grading/dramage must be maintained throughout entire project to ensure eligibility for inspections and utility release. 13. Provide energy code compliance certification to the Inspection Division prior to occupancy. 14. Any changes to the project after building permit is issued, in writing and approved by the City prior to changes bein&%Jm 15. Provide Sample Well in accordance with "Sample Well Detail' (Available upon request) SACPSha e\ATSPECTION DIVISION\InspectionsKbMMERCIAL PLAN REVIEW N0TESnov05&c 0 IV. APPLICABLE CODES 2003 INTERNATIONAL BUILDING CODE (IBC) 2003 INTERNATIONAL PLUMBING CODE (IPC) 2003 INTERNATIONAL MECHANICAL CODE (IMC) 2003 INTERNATIONAL FUEL GAS CODE (IFGC) 2003 INTERNATIONAL RESIDENTIAL CODE (IRC) 2003 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2005 NATIONAL ELECTRICAL CODE (NEC) WITH LOCAL AMENDMENTS' (COMMERCIAL & RESIDENTIAL) 1994 SBCCI FIRE CODE 1997 LIFE SAFETY CODE NFPA 101 ADOPTED AMENDMENTS TO. FIRE CODE (AVAILABLE ON-LINE) ***On September 12, 2005, Ord #96-2079 H (which revised the city's local electrical amendments) was passed by City Council. These changes become effective November 12, 2005. SACPSham\WSPEMON DIVISIONVvsp,, io WesidentW Construction PackcAAPPUCABLE CODES-600-05 i/GAO a- �fcAD•>a3 - -7 �- 0Sl— oc0_ CITY OF LA PORTE COMMERCIALANDUSTRIAL APPLICATION FOR UTILITY SERVICE(S) (2.5 AC. & BELOW) PERSON MAKING REQUEST: STREET ADDRESS (WHERE W/S IS LEGAL DESCRIPTION: 04 L.P. PROPERTY SIZE:* *AREA DESIGNATED SHALL INCLUDE REQUIRED SETBACKS. "MUST BE AT OR BELOW 108,900 SQ. FT. TO USE TffiS FORM. WATER DEVELOPMENT FEE - $8.42 PER 100 SQ. FT. $ W eT Q WATER TAP - $388.00 (5/8-3/4" TAP ONLY) $ exls4 i a a TOTAL WATER CHARGES $ SEWER DEVELOPMENT FEE - $15.10 PER 100 SQ. FT. SEWER TAP - $315.00 (6" TAP*) $ n SEWER INSPECTION FEE $ A/ A TOTAL SEWER C GES TOTAL WATER & SEWER CHARGES $ -- SIGN OF PERSON MAKING REQUEST! ) FOR LIVESTOCK USE ONLY — WATER FRONT FOOT FEES NOT APPLICABLE AT THIS TIME. *MINIMUM SIZE TAPS AS PER P. I. C. M. SANITARY SEWER DESIGN REQUIREMENTS, CHAPTER 4, SECTION 4.03-G. NOTE: FOR LARGER TAPS CONTACT WATER/SEWER SUPERINTENDENT. DATE OF PAYMENT: RECEIPT NUMBER - CLERK'S INITIALS: SACPShareVNSPECTION DIVISIONIinVeaaamMater& Sewer tie on com-prop.doc (2.5 Ac&below) - 11-16-05 Rev. .- -- - -6- 1. CITY OF LA PORTE 604 W FAIRMONT PARKWAY0 LA PORTE, TEXAS LA PORTE TX 77571 C E R T I F I C A T E O F O C C U P A N C Y Issue Date . . . Parcel Number . . Property Address Subdivision Name Legal Description Property Zoning . Owner . . . . . . Contractor . . . Application number Description of Work Construction type Occupancy type . Flood Zone . . . . P E R M A N E N T 10/17/06 023-256-081-0002 101 E MAIN ST UB LA PORTE TX 77571 LA PORTE LTS 1 2 3 & 4 BLK 181 LA PORTE MAIN STREET DISTRICT SALTERRY INC LEW WIGGS 832 969-7360 06-00000398 000 000 REMODEL, RETAIL STORE/CUSTOMER SERVICE METAL FRAME (TYPE III) BUSINESS Approved . . . . . . . Bui ding Official VOID UNLESS SIGNED BY BUILDING OFFICIAL CL INSPECTION r DATE RESULT INSPECTOR MARKS FAXED: T POLE CONST ELEV CERT recVd if in AEIVE zone FORM SURVEY H applicable) ROUND PLUMBING D a- - u J-J" --AJn s l 7 PIERS _0 (f 1 SLAB/FOUNDATION WATER SERVICE LINE SEWER ELEC UNDERGROUND (if applicable) COVER-UP /�y(iT/DTI J~ /`5=06 eS Will, u)A41, S LEAD TEST ' -Q/p BRICK TIE DRIVEWAY SIDEWALKS FINAL DRAINAGEIGRADING FINAL ELEV CERTIFICATE RECEIVED: ELEVATION SHOWN FOR TOP OF FINISHED F� REQUIRED BFE: IS THE ELEVATION SHOWN 12" OR MORE ABOVE.BFE: (NO) GAS FINAL Cj TO v �i ' i 3 = 0 I C FAXED: FAXED: ELECTRIC FINAL' OTHER (patio, lawn o :I sprinklers, etc.) p ���D -rc n1oT ��d�f No 8.iwt.,�, Q- 8-0� TC �,y�.,� t j0-f Z -o c, cater T,uy. pLQh S1CPSHAREV SPECTIONSDMSION4NSPECTIONSVtES1IOML INSP SHEET06MXLS k GCII, to -12-0 0I TC .. �m srn� 7 rrn�m•� COMMERCIAL w.& S WORx ORDER- t DATE 3 - I % -OG NEW ADDITION ADDRESS U I E )Yn I} j 'A) ST LEGAL DESCRIPTION L 0+ t- 4 b I I L 171 / L- 100 r4 � OWNER IDS f��12+14a1iF� CONTRACTOR I DATE WATER FRONT FT FEES SEWER FRONT FT FEES SEWER TAP FLOOD ZONE PERMIT (required if AE or VE zone) BUILDING PERMIT PLAN REVIEW FEE NBC (� 7-/? pb% ELECTRICAL PERMITS ao (�(� TEMPORARY POWER POLE PLUMBING PERMIT �T `, ,(KV� CAL PERMIT . VAT f-i�ad. ' lcYN PA# ADDRESS REQUEST ZONING CLASSIFICATION FLOOD ZONE f:lll iel�7/n►b�Yb:7i 1 Y r 171 �: UTILITY EXT. AGRMT REC'D Y OR N BLDG PLANS REVIEWED. FEES PAID N/A i r � G - -161-1 29 o 6, 39E 3:� a(e lS-(a 3 " CU of La Po 7 JVG MVVHCJp O •yv INSPECTION TY �a." �( DATE: Gy THIS JOB HAS NOT. BEEN COMPL The following additions or corrections s made before the iob`will be acc e lc-� d v -P ` It is unlawful for any Carpenter, Contractor, Builder, or other persons, to cover or cause to be covered, any part of the work with flooring, lath, earth or other material, until the proper inspector has had ample time to approve the installation. r After additions or corrections have been made, 'i call 281-470-5130 4 For additional information call 281-470-5073. r PRESS HARD - USE BALL POINT PEN CITY OF LA PORTE, TX R P R I N T *** CU -._JMER RECEIPT Batch ID: PE —TEMP 9/14/06 01 Receipt no: 138731 Type SvcCd Description Amount RE REINSPECTION FEE Qty 1.00 $35.00 GRILL&BAR/101 E MAIN Tender detail CA CASH $35.00 Total tendered: $35.00 Total payment: $35.00 Trans date: 9/14/06 Time: 8:08:38 THANK YOU FOR YOUR PROMPT PAYMENT 0 FROM :AMERICAN PLUMBING .... .. •vvv V. w•Vv, , FAX NO. :2815421137 )ct. 18 2006 08:03RM P2 I IIn. IIV. I• `, � OP City of La Porte Beckflow Prevention Assembly Certtfied Test and Maintenance Report Planning and Inspacgons Publo Warka Ikpadmenl . Fax (281)470-5005. Fax (281).47p5129 PWSID8'1010010 ME OF P Ty: LLATMN PROPGRTYAPQRESS ink 1?-. W"`knAAp NEW INSTALLATION ANNUAL RETEST ❑ REPLACEMENT ❑ Pke3a cheek one MAIUNGAOOREsa: NrACT PERSO PHONE NO.: ,)o T b,ddIoY PvvvA" .u1m h dd W' ' M, 6"n'kW and NMn(ahAd m r&plryd bl TKRCO npvllrIlwm 'aO N auf!AW M W Cp�NW1yVAINn io0oPlPDie PYvrMin. .. .. .. '. TYPE OP ABSEMSLV -sib MOLWCD FMlN Amm PRINCIPLE 'QW) CJ REOUCEDPPU3UREPRIXCIPIC- DETECTOR L� 'OOUeIA CNECN VALVC(OCV) O WU4FCMaCX•DaTICTOR O PPZ88URE VACUUM OR AKEA IPVa) O WIU.-RESISTANT PRCSSUM VACWM eRLMDFt (M) MANUFACTURER A_Al i S MODEL#- SERIAL NO. 251 1/a, . LOCATED AT:�;,(Q ZpQt) iC P iRs _ DATE Ih LED F&DUC666PPIRi Pt kchkA AWE Y PREAwRa VACUUM BREAKER AM ZW DOUBLi CKECKVALVE I LY I Reu f VM.V6 CMECKei AIR MLET C-XCKVALVE CKECKPI WRLLL RA TT W=AT. '• PIID CLOSID lKlMT, ci WQO♦ PAID CLOXD 4C O AT PCID �NED 17 __ no NELD AT PSID ' LF D O LEAKED O DID NOT OPB/ ❑ DID NOI OPeN . O LSAKW ❑ WAIRO AND MATUPAMA Dam FINAL „ P i NELDA P'ST0 OPENEDAT OP OAT OAT QAT ❑ O!r TKIM PSO ...PWO _Pao MA"/MOOeL Se1tW,NQ (nSCI-376 ., CAWIRATION DATe 13 the m&% m* k4t& ed In iDDDTdWV0 YA1h DW RWwledwors roAmmm+detlons end Im WO eoddel MlMARKID TIIE AtK)YE Ia GT!R7ITTFA TO aET)ttR,(lhP lPd nPaP roKFaMto.PerNyFdAf iP/✓•INYd NslNp drDf P+y! ' CN(TIF)60 i[e74RS fWM NaIAE TIPIED Tgurn W� A" of •TESnNO PAWP ADDRESS' ' C1mTIYIEO TeeTER WWwi- J �T CMTtFIeO TXneR NO 1a PA'Iinb �t 9i PHONE MAABER WOC•bNWNVER -•pbPnr m aETgm CPRIPMWY TEST DATE —mm AtKOP mlKl N /dkMd SV PI WYd drw MeM •'1rPnE u npWwd.pon Indablbv.npM, amacPour —rESnNQ 13 REOUWAV ANNUALLY FOR NION HEALTH HAZARO LOCATIONS REV. 3aws (281)470-5073 City of La Porte 604 W Fairmont Pkr,' La Porte, Tx 7757" INSPECTION LINE:(281) 470-5130 ****PLUMBING PERMIT**** --------------------------------- Application Number . . . . Property Address . . . . . HCAD Number . . . . . . . . Alternate Search Method . . Application type description Subdivision Name . . . . . Property Use . . . . . . . Property Zoning . . . . . . Owner ---------------------------------------- 06-00001563 Date 10/11/06 101 E MAIN ST UB 023-256-081-0002 PLUMBING ONLY LA PORTE MAIN STREET DISTRICT Contractor ------------------------ SALTERRY INC ------------------------ AMERICAN PLUMBING & MAINT. 2005 YORKTOWN CT 10523 N AVE P SEABROOK TX 77586 LA PORTE TX 77571 (281) 487-2274 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING PERMIT Additional desc . . INSTALL NEW WTR SRV TO BLDG Permit Fee . . . . 26.25 Issue Date . . . . 10/11/06 Valuation . . . . 0 Expiration Date . . 4/09/07 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 7.5000 EA PL - WATER PIPE/TREATING EQUIP 7.50 1.00 3.7500 EA PL-VACCUM BREAK/BACKFLOW <6 3.75 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited -------------------- Due --------------------------- Permit Fee Total 26.25 26.25 .00 .00 Grand Total 26.25 26.25 .00 .00 ------------2� --- �7- -_-------------------------- Signa re of contractor or authorized agent Date Approved by Building Official or authorized agent !D Date PF,RMTT APPLICATION CR of ` City of La Porte Established 1892 r .. 281-470-5073 nyJ Building Mechanical *Electrical 'Plumbing. '(See back of form) Project Address: D n Lot: Owner's Street L0 E. Contractor: N n^� (L� c rA �1 V vri Phone: i1g I N 1 ZZZ q Address: Street City Zip Contractor Email address: Fax: Contact Person: &Z'c WS Engineer: Sq. Footage: # Stories Describe Work: �ti A6=�c�, uja:AA /V%J- w tad Q WRMANIi.NTI.V AT TiMF. OF FiNAI. NOT A VALID PERMPr UNTIL OWNER IS NOTIFIED OF APPROVAL & ALL APPLICABLE FEES ARE PAID IN FULL APPLICANTS SIGNATURE DATE: Occupancy Type Flood Zone Class Work Sq. Ft. Construction Type Use Zone # Stories Parking Req Last use of Building Date use ceased: Commercial Buildings Plans Only -Fire Marshal Chocked/Approved for Issuance By; CE: Special Taxes HCAD Residential driveway tie-in fee: ^//__ Parkland(New Res. Off: Zone # Fee: Permit No. /�6 "l S� 3 Permit FeePlan Check Fee: s:\CPsh=UnVeM=\Bldy a=LA.PPN2406.dw COMPLETE THIS SECTION FOR ELECTRICAL PERMITS:: NOTE: MINIMUM CHARGE ON PERMIT(S) IS $20.00 Description Charges Quantity Fees PERMIT ISSUE FEE $7.50 _$7.50 Outlets, Fixtures, Lights & Switches (1" 5 - Flat fee) $ 3.00 Above Items (All Others) .60 each Clothes Washer/ Dryer $ 2.00 each Range Receptacle $ 3.00 each Cook Top or Oven $ 1.50 each A/C, Window Unit Receptacle $ 3.00 each Water Heater $ 3.75 each Dishwasher/Garbage Disposal $ 1.50 each Meter Loop & Service (includes Temporary cut -in) $15.00 each Temporary Saw Pole (T Pole) $15.00 each Reconnection ofService $15.00 each Remspection Fee $35.00 each w MOTORS: Up to but not including %2 hp $ 1.50 each %2 hp and less than 10 hp $ 2.50 each 10 hp & up to 50 hp $ 3.50 each 50 hp and up $ 4.50 each Total Fee COMPLETE THIS SECTION FOR PLUMBING PERMITS NOTE: MINIMUM CHARGE ON PERMIT(S) IS $20.00 Description Charges Quantity Fees PERMIT ISSUE FEE $15.00 Fixtures/Drains/Traps $ 3.75 each Sewer (New, Repair, or Replacement) $ 7.50 each Septic TanVSeepage Pit/Drain Field $15.00 each Water Heater $ 3.75 each Gas Piping System (1-4 outlets,,Jlatfee) $ 7.50 Gas Piping System (over 4 outlets -each) $ 1.50 each Installation, Alteration or Repair of Water Piping and/or Water Treating Equipment $ 7.50 each Repair/Alteration - Drain or Vent $ 7.50 each Each Vacuum BreakerBackIlow Protection Each One (1-5) $ 3.75 each Each One (Over 5) $ 2.25 each 1 Remspection Fee $35.00 each Total S:1CPSb=\1NSPECI70N DMS10N\1mpeaiom\B1dg Permit Appl side2 112905.doc $15.00 City of La Porte 604 W Fairmont Pkwy r ' La Porte, Tx 77571 ` (281)470-5073 INSPECTION LINE:(281) 470-5130 ****MECHANICAL PERMIT**** ---------------------------------------------------------------------------- Application Number . . . . . 06-00000398 Date 8/22/06 Property Address . . . . . . 101 E MAIN ST UB HCAD Number . . . . . . . . . 023-256-081-0002 Alternate Search Method . . . Application type description REMODEL, RETAIL STORE/CUSTOMER SERVICE Subdivision Name . . . . . . LA PORTE Property Use . . . . . . . . Property Zoning . . . . . . . MAIN STREET DISTRICT Owner Contractor ------------------------ ------------------------ SALTERRY INC LEW WIGGS 2005 YORKTOWN CT 4638-A LAIGLE RD SEABROOK TX 77586 MANVEL TX 77578 (832) 969-7360 Other struct info . . . . . FLOOD ZONE X ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL PERMIT Additional desc . REFRIGERATION/FREEZER/WALKIN Sub Contractor JOHNSTON REFRIGERATION Permit Fee . . . . 30.00 Issue Date . . . . 8/22/06 Valuation . . . . 1000 Expiration Date . . 2/18/07 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 15.0000 THOU MECH - UP TO $1,000 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 1. AS PER PRINTS & NOTES 2. CALL FOR INS PECTION 3. UNLOAD ALL MATERIAL & EQUIPME NT ON THIS SITE NOT R.O.W. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ---------- Due ---------- ----------------- Permit Fee Total -------------------- 30.00 30.00 .00 .00 Grand Total 30.00 30.00 .00 .00 for or au zed agent by Building Official or authorized agent Da e D to - " PERMIT APPLICATION IN, 1.2 City of La Porte 281-470-5073 Mechanical *Electrical Subdivision: Block: Owner's G Established 1892 *Plumbing Zi Ci`'' ..... P ,ejc 0-r050l/ 1,7P-3-2— Street S —r— City Zip Contractor Email address: Ao / 3,2rF5� Fax f in 4e Contact Person: ) C Engineer: Building Use: , L S -7'/ e. l�. a ✓ / . Valuation: f1a le,90 Sq. Footage: # Stories . axWYL_ .Ov`- Describe Work: ufall/Z N2 GOD Lam/ Occupancy Type Flood Zone Class Work Sq. R. Construction Type Use Zone # Stories Parking Rest Last use of Bull dsg Date use ceased: Commercial Buildings Plans Only -Fire Marshal Approval Date Checked/Approved for Issuance CE: Special Residential driveway tie-in fee: IV P url�tes. Only):): Zone # Fee: Permit No. ® Permit Fce�1 p•l lJ Plan Check Fee: s:mCPshmUnsveai=\BldgPamhArv042406.ax COMPLETE THIS SECTION FOR ELECTRICAL PERMITS:: NO MINIMUM CHARGE ON PERMIT(S) IS $20.00 Description Charges Quantity Fees v PERMIT ISSUE FEE Outlets, Fixtures, Lights & Switches (10 5 — Flat fee) Above Items (All Others) Clothes Washer/ Dryer Range Receptacle Cook Top or Oven A/C, Window Unit Receptacle Water Heater Dishwasher/Garbage Disposal Meter Loop & Service c. (includes Temporary cut -in) Temporary'Saw Pole.(T Pole) Reconnection of Service \, _ Reinspection Fee MOTORS: Up to but not including Y2 hp Y2 hp and less than 10 hp 10hp&up to50hp 50 by and up $7.50 _ $ 3.00 .60 each $ 2.00 each $ 3.00 each $ 1.50 each $ 3.00 each $ 3.75 each $ 1.50 each h 1 $15.00 each $15.00 each $ B.00 each $35.00 each $ 1.50 each $ 2.50 each $ 3.50 each $ 4.50 each Total Fee COMPLETE THIS SECTION FOR PLUMBING PERMITS NOTE: MINIMUM CHARGE ON PERMIT(S) IS $20.00 Description Charges Quantity Fees PERMIT ISSUE FEE $15.00 Fixtures/Dramslrraps $ 3:75 each Sewer (New, Repair, or Replacement)- $a7.5.6eacl' - Septic Tank/Seepage Pit/Drain Field $15.00 each Water Heater $ 3.75 each Gas Piping System (1-4 outlets, flatfee) $ 7.50 Gas Piping System (over 4 outlets -each) $ 1.50 each Installation, Alteration or Repair of Water Piping and/or Water Treating Equipment $ 7.50 each Repair/Alteration — Drain or Vent $ 7.50 each Each Vacuum BreakerBackflow Protection Each One (1-5) $ 3.75 each Each One (Over 5) $ 2.25 each Reinspection Fee $35.00 each Total SACPSbme\1NSPECr10N DMSIOM[nspeaiominldg Permit App) side2 112805.doc 15.00 City of La Porte 604 W Fairmont Pl,' La Porte, Tx 775`-. F (281)470-5073 INSPECTION LINE:(281) 470-5130 ****ELECTRICAL PERMIT**** ---------------------------- ---------------------------------------- Application Number . . . . . 06-00000398 Date 7/17/06 Property Address . . . . . . 101 E MAIN ST UB HCAD Number . . . . . . . . . 023-256-081-0002 Alternate Search Method . . . Application type -description REMODEL, RETAIL STORE/CUSTOMER SERVICE Subdivision Name . . . . . . LA PORTE Property Use .. . . . . . . . Property Zoning . . . . . . . MAIN STREET DISTRICT Owner Contractor ------------------------ ------------------------ SALTERRY INC LEW WIGGS 2005 YORKTOWN CT 4638-A LAIGLE RD SEABROOK TX 77586 MANVEL TX 77578 (832) 969-7360 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL PERMIT Additional desc NEW ELECTRICAL COMMERCIAL Sub Contractor NBC ELECTRIC Permit Fee . . . . 120.50 Issue Date . . . . 7/17/06 Valuation . . . . 0 Expiration Date . . 1/13/07 Qty Unit Charge Per Extension BASE FEE 7.50 120.00 .6000 EA EL - OUTLETS, SWITCHES (OTHER) 72.00 4.00 3.0000 EA EL -.A/C, PLUG-IN UNITS 12.00 1.00 1.5000 EA EL-DISWASHER/ GARBAGE DISPOSAL 1.50 1.00 15.0000 EA EL - METER LOOP & SERVICE/TCI 15.00 5.00 2.5000 EA EL - 1/2 HP AND UP TO 10 HP 12.50 ---------------------------------------------------------------------------- Special Notes and Comments 1. AS PER PRINTS & NOTES 2. CALL FOR INS PECTION 3. UNLOAD ALL MATERIAL & EQUIPME NT ON THIS SITE NOT R.O.W. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ------------------------------ --------------------------- Permit Fee Total 120.50 120.50 .00 .00 Grand Total 120.50 120.50 .00 .00 ------- ----------- ------------------------------------------------ i Mf Contr ctor or Authorized Agent VDae D� App ov d by Building Official or Authorized Agent PERMIT APPLICATION o• .,4� City of La Porte Established 1892 281-470-5073 Building Mecbanical 'Electrical `/ *Plumbing !(See back of form) Project Address: /D / � �A /A% S T C) f2 Lot. eCQwnerIs I"iC : 8.32- 967-77360 �Kddress: =065 y0/LKi'OwN c.7 5�A(3260\4 7-758(- Street city zip is 3 Z- 375-0/- C-0 ` Address: 7//7 3it6ULP3 46USFU&-) —7706L Street City -zip Contractor Email address: Fax Contact Person Building Use: Sq. Footage: # Sto 'es Valuation: Describe Work: fly /FlfeC�/�L 2£ST�c1�24� ADDRESS NIIMBERS MUST BE POSTED DURING CONSTRUMON & PERMANENTLY AT TIME OF FINAL INSPECTION. NOT A VALID PERMIT R IS NO D OF APPROVAL & ALL APPLICABLE FEES ARE PAID IN FULL APPLICANTS SIGNA DATE: % ' / 7 _ APPLICANTS PRINTED NAME 7� -14 J A ZA JiS For City Use Only Occupancy Type Flood Zone Class Work ; . Sq. Ft Construction Type Use Zone # Stories Parking Req.- Last use ofBuildino Date use ceased: Commercial Buildings Plans Only -Fire Marshal Approval Date Checked/Approved for Issuance By: Date CE: Special Conditions: Taxes . HCAD Residential driveway tie-in fee: PA d ew Zone # Fee: Permit No. Permit Fee. ��; d Plan Check Fee: S:�crsnu U.T.M..;MldO..tAP 2406.dw COMPLETE THIS SECTION FOR ELECTRICAL PERMITS:: NOTE: MINIMUM CHARGE ON PERMIT(S) IS $20.00 Description Charges Quantity Fees PERMIT ISSUE FEE $7.50 $7.50 Outlets, Fixtures, Lights & Switches (1° 5 - Flat fee) $ 3.00 Above Items (All Others) .60 each 1";7 C) Clothes Washer/ Dryer $ 2.00 each Range Receptacle $ 3.00 each Cook Top or Oven �.,.$'1.50 each A/C, Window Unit Receptacle $ 3.00 each Water Heater I $ 3.75 each Dishwasher/Garbage Disposal $ 1.50 each i Meter Loop & Service (includes Temporary cut -in) $15.00 each Temporary Saw Pole (T Pole) $15.00 each Reconnection of Service $15.00 each Reinspection Fee $35.00 each MOTORS: Up to but not including '/2 hp $ 1.50 each %2 hp and less than 10 hp $ 2.50 each 5 10 hp & up to 50 hp $ 3.50 each 50 hp and up $ 4.50 each Total Fee COMPLETE THIS SECTION FOR PLUMBING PERMITS NOTE: M]NIMUM CHARGE ON PERM[T(S) IS $20.00 Description ChargesQuantity Fees PERMIT ISSUE FEE ' $15.00 $15.00 FixfiuiWDrams/Iraps $ 3.75 each Sewer (New, Repair, or Replacement) $ 7.50 each Septic Tank/Seepage PiuDrain Field $15.00 each Water Heater $ 3.75 each Gas Piping System (1-4 outlets, flatfee) $ 7.50 Gas Piping System (over 4 outlets -each) $ 1.50. each Installation, Alteration or Repair of Water Piping and/or Water Treating Equipment $ 7.50 each Repair/Alteration - Drain or Vent $ 7.50 each Each Vacuum BreakerBackflow Protection Each One (1-5) $ 3.75 each Each One (Over 5) $ 2.25 each Reinspection Fee $35.00 each Total .. S:1CPShzreVNSPECIT0N DMSIONVnspeuio \Bldg Permit Appl side2 112805.dec City of La Porte i604 ,W Fairmont MY 0 La Porte, Tx 77571 (281)470-5073 INSPECTION LINE:(281) 470-5130 ****MECHANICAL PERMIT**** ---------------------------------------------------------------------------- Application Number . . . . . 06-00000398 Date 5/12/06 Property Address . . . . . . 101 E MAIN ST UB HCAD Number . . . . . . . . . 023-256-081-0002 Alternate Search Method . . . Application type description REMODEL, RETAIL STORE/CUSTOMER SERVICE Subdivision Name . . . . . . LA PORTE Property Use . . . . . . . . Property Zoning . . . . . . . MAIN STREET DISTRICT Owner Contractor ------------------------ ------------------------ SALTERRY INC LEW WIGGS 2005 YORKTOWN CT 4638-A LAIGLE RD SEABROOK TX 77586 MANVEL TX 77578 (832) 969-7360 Other struct info . . . . . FLOOD ZONE X ---------------------------------------------------------------------------- Permit . . . . . . MECH. PERMIT - VENT HOOD Additional desc INSTALL VENT HOOD/FIRE SYSTEM Sub Contractor SPECIALIZED FIRE & SAFETY Permit Fee . . . . 72.00 Issue Date . . . . 5/12/06 Valuation . . . . 15000 Expiration Date . . 11/08/06 Qty Unit Charge Per Extension BASE FEE 30.00 14.00 3.0000 THOU MECH - $1001 & UP 42.00 ---------------------------------------------------------------------------- Special Notes and Comments 1. AS PER PRINTS & NOTES 2. CALL FOR INS PECTION 3. UNLOAD ALL MATERIAL & EQUIPME NT ON THIS SITE NOT R.O.W. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 72.00 72.00 .00 .00 Grand Total 72.00 72.00 .00 .00 -----------F-------------------------------------------------------------- of cnvt�ractor or by Building Official agent Date rized agent Date PERMT APPLICATION �iq cFi f�( AO• Mqy O L City of La Porte Esth�ars9z 3 200 81-470-5073 10 06 uddin a cal 'Electrical *Plumbing *(See back of form) Project Address: ) 0l Z W0 rQ Lot: 3 -I Subdivision 7a(),.P-, Block: Owner's Name: ETC C Phone: ' 713 - -- - Street -/ T Contractor: . Stec•,, Z� `1 rlil Address: Ill /70. A /a �4 Street city y - Zip le,l, Phone: Of - /_ 0 /, le / Zip . Contractor Email address: Fax Contact Person: - 7F i &-., Engineer: Building Use: Valuation: INSPECTION. Occupancy Type 6 !-9 A, Construction Type Last use of Building For City Use Flood Zone X Use Zone Ns�&Jv- Commercial Buildings Plans Only -Fire Marshal Checked/Approved for I Permit No. o� — Permit Sq. Footage: # Describe -v-o6 Class Work ReO* Sq. Ft. # Stories Parking Req- dA/A use ceased: a C \t il COMPLETE THIS SECTION FOR ELECTRICAL PERMITS:: NOTE: MIND" CHARGE ON PERMIT(S) IS-$20.Q Description Charges Quantity -Fes PERMIT ISSUE FEE $7.50 Outlets, Fixtures, Lights & Switches (1" 5 - Flat fee) $ 3.00 Above Items (All Others) .60 each Clothes Washer/ Dryer $ 2.00 each Ranieleceptacle $ 3.00 each Cook Top or Oven $ 1.50 each A/C, Window Unit Receptacle $ 3:00 each Water Heater $ 3.15 each Dishwasher/Garbage Disposal $ 1.50 each Meter Loop & Service (includes Temporary cut -in) $15.00 each Temporary Saw Pole (T Pole) $15.00 each Reconnection of Service $15.00 each Reinspection Fee $35.00 each MOTORS: Up to but not including %2 hp $ 1.50 each %2 hp and less than 10 hp $ 2.50 each 10 hp & up to 50 hp $ 3.50 each 50 hp and up $ 4.50 each Total Fee COMPLETE THIS SECTION FOR PLUMBING PERMITS NOTE: MINIMUM CHARGE ON PERMIT(S) IS $20.00 Description Charges Quantity . Fees PERMIT ISSUE FEE $15.00 Fixtures/Drams/traps $ 3.75 each Sewer (New, Repair, or Replacement) $ 7.50 each Septic Tank/Seepage Pit/Drain Field $15.00 each Water Heater $ 3.75 each Gas Piping System (1-4'outlets, flatfee) $ 7.50 ' Gas Piping System (over 4 outlets -each) $ 1.50 each Installation, Alteration or Repair of Water Piping and/or Water Treating -Equipment $' 7.50 each Repair/Alteration - Drain or Vent $ 7.50 each Each Vacuum BreakerBackflow Protection Each One (1-5) $ 3.75 each Each One (Over 5) $ 2.25 each. _ Reinspection Fee $35.00 each _ Total SACPShueUNSPEC TON DIVISIONUnspectioosUdldg Permit Appi side2 112805.doc 7.50 15.00 LA PORTE FIRE MARSHAL'S OFFICE PLAN REVIEW Main 101 Grill & Bar 101 E. Main Vent Hood Suppression System Date: 05 / 03 / 2006 Reviewed by: Clif Meekins, Fire Marshal Approved: Yes, With Noted Chages The following items are identified by the Fire Marshal's Office during the plan review: 1) The suppression system must have an audible alarm tied into it. 2) The Fire Marshal must witness a function test of the vent hood suppression system. 3) Contact the Fire Marshal's Office 24hrs in advance to schedule a vent hood suppression system function test. 4) Ensure that a Class "K" Fire Extinguisher is in place 604 West Fairmont Parkway La Porte, TX 77571 Office: 281-867-4603 Fax: 281470-5005 44fe, le r, ' �'7 f eR 46s R- � 03�O 1006' • b � J ♦ l b1i � aft 3 ' �N ►r 4 �� oveol City of La Porte 604 W Fairmont Pk( La Porte, Tx 7757 (281)470-5073 INSPECTION LINE:(281) 470-5130 ****PLUMBING PERMIT**** --------------- Application Number . . . . Property Address . . . . . HCAD Number . . . . . . . . Alternate Search Method . . Application type description Subdivision Name . . . . . Property Use . . . . . . . Property Zoning . . . . . . Owner ------------------------ SALTERRY INC 2005 YORKTOWN CT SEABROOK TX ----------------- 06-00000398 Date 4/12/06 101 E MAIN ST UB 023-256-081-0002 REMODEL, RETAIL STORE/CUSTOMER SERVICE LA PORTE MAIN STREET DISTRICT Contractor ------------------------ LEW WIGGS 4638-A LAIGLE RD 77586 MANVEL TX 77578 (832) 969-7360 ----------------------------------------------- Permit . . . . . . PLUMBING PERMIT Additional desc . . GREASE TRAP & SAMPLE WELL Permit Fee . . . . 22.50 Issue Date . . . . 4/12/06 Valuation . . . . 0 Expiration Date . . 10/09/06 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 3.7500 EA PL - FIXTURES/DRAINS/TRAPS 7.50 --------------------------------------------------------------------------- Special Notes and Comments 1. AS PER PRINTS & NOTES 2. CALL FOR INS PECTION 3. UNLOAD ALL MATERIAL & EQUIPME NT ON THIS SITE NOT R.O.W. ---------------------------------------------------------------------- Fee summary Charged ---------- Paid ---------- Credited Due -------------------- ----------------- Permit Fee Total 22.50 22.50 .00 .00 Grand Total 22.50 22.50 .00 .00 rye f co tractor or authorized agent Date 2 3 by Building Official or authorized agent aD to PERMIT APPLICATION City of La Porte Established 1892 281-470-5073 Building Mechanical 'Electrical Thumbing Subdivision Block Owner's Name: Phone: CY.,00r rity 7.in Street ulty zip Building Use: Sq. Footage: # Stones Valuation: Describe Work �G For City Use Only Occupancy Type Flood Zone Class Work Sq. Ft. Constriction Type Use Zone # Stories Parking Commercial Buildings Plans only -Fire Marshal Approval Date CE: Special Taxes- on & Residential�1eway tie-in fee: Permit No Permit Fe j) �" Plan Check Fee: S:Wesshmev�peai=U94BPamdAPp102505Am 604 W. Fairmont Pkwy. • La Porte, Texas 77M • (281) 471-5020 COMPLETE THIS SECTION FOR ELECTRICAL PERMITS:: NOTE: MINIMUM CHARGE ON PERMTT(S) IS $20�00 Description Charges Quantity Fees PERMIT ISSUE FEE $7.50 Outlets, Fbitures, Lights & " Switches (Id 5 - Flat fee) $ 3.00 Above Items (All Others) .60 each Clothes Washer/ Dryer $ 2.00 each Range Receptacle $ 3.00 each Cook Top or Oven $ 1.50 each A/C, Window Unit Receptacle $ 3.00 each Water Heater $ 3.75 each Dishwasher/Garbage Disposal $ 1.50 each Meter Loop & Service (includes Temporary cut -in) $15.00 each Temporary Saw Pole (T Pole) $15.00 each Reconnection of Service $15.00 each Remspedion Fee $35.00 each MOTORS: Up to but not including %, hp $ 1.50 each hp and less than 10 hp $ 2.50 each 10 hp & up to 50 by $ 3:50 each 50 hp and up $ 4.50 each Total Fee COMPLETE THIS SECTION FOR PLUMBING PERMITS NOTE:, MINIMUM CHARGE ON PERMIT(S) IS $20.00 Description Charges Quantity Fees PERMIT ISSUE FEE $15.00 . Fildures/Drains/Traps $ 3.75 each Sewer (New, Repair, or Replacement) $ 7.50 each Septic Tank/Seepage Pit/Drain Field $15.00 each Water Heater $ 3.75 each Gas Piping System (1-4 outlets, flatfee) $ 7.50 Gas Piping System (over 4 outlets -each) $ 1.50 each Installation, Alteration or Repair of Water Piping and/or Water Treating Equipment ... $ 7.50 each Repair/Alteration - Drain or Vent $ 7.50 each Each Vacuum Breaker/Backflow Protection Each One (1-5) $ 3.75 each Each One (Over 5) $ 2.25 each Reinspection Fee $35.00 each Total S. CPSbwvUNSPWn0N DIVISIONUngsc6a Bl ft Pamrt Appl ci& a 112805.dx 7.50 15.00 City of Lra Porte 604 W Fairmont Pkwy La Porte, Tx 77571 (281)470-5073 INSPECTION LINE:(281) 470-5130 ****MECHANICAL PERMIT**** Application Number . . . . . 06-00000398 Date 4/05/06 Property Address . . . . . . 101 E MAIN ST UB HCAD Number 023-256-081-0002 Alternate Search Method . . . Application type description REMODEL, RETAIL STORE/CUSTOMER SERVICE Subdivision Name . . . . . . LA PORTE Property Use . . . . . . . . Property Zoning . . . . . . . MAIN STREET DISTRICT Owner ------------------------ SALTERRY INC 2005 YORKTOWN CT SEABROOK TX 77586 Other struct info Contractor ------------------------ LEW WIGGS 4638-A LAIGLE RD MANVEL TX 77578 (832) 969-7360 FLOOD ZONE X ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL PERMIT Additional desc HVAC Sub Contractor LABILLS SERVICE CENTER Permit Fee . . . . 72.00 Issue Date . . . . 4/05/06 Valuation . . . . 15000 Expiration Date . . 10/02/06 Qty Unit Charge Per Extension BASE FEE 30.00 14.00 3.0000 THOU MECH - $1001 & UP 42.00 ---------------------------------------------------------------------------- Special Notes and Comments 1. AS PER PRINTS & NOTES 2. CALL FOR INS PECTION 3. UNLOAD ALL MATERIAL & EQUIPME NT ON THIS SITE NOT R.O.W. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 72.00 72.00 .00 .00 Grand Total 72.00 72.00 .00 .00 ------7 ------------------------------------------------ ------------ Signatur f contractor or authorized agent Date / Approved by Building Official or authorized age r /4 Date V f PERma APPLICArnaA City of La Porte Established 1892 291-470-5073 Brulding Mechanical (� *Electrical *Phrmbing *(See back of form) Subdivision Bloc Owner's Name: rN �� `� eP� Phone: /. % 0 9-1 f c 01. Contact, Lo �(A 15 Sa ✓ULcp �tiu� � � � � 2 b � Phone: a 5 9 6 ' 4'S 00 0,f3� 5 )7ZC Sa!ex7 cq W4 City 0 Btnlding Use R� 57Qv,� Sq: Footage: 3 on 0 , t- # Stodes�- TO, Valuation l b i 096 gy mac' ozy �y. -; _ Describe Wodc - l/ i Z For Cq Use Only Occupancy Type . Flood Zone Grass Wo>jc Sq. Ft Construction Type Use Zone # Stories. Pig R �. . Comramc is l B ildings Plans On -Fire Marshal Approval Checb5d/Approved for Issuance By Date CB:y�Specxal Conditions: Taaes B:CAD Residen/b'i-al'drive'w\ay tie-in fee: . Permit No. Permit Fee 1y� Phan CheckFm &rcrshzv r rr102505A. 604 W. Fairmont Pkwy. La Porte, Texas 775t • (281) 471-5020 COMPLETE THIS SECTION FOR ELECTRICAL PERDIITS:: NOTE: MWIM 1M CHARGE ON PERMITS) IS $20.00 Description Charges Quantity Fees PERMIT ISSUE FEE $7.50 $7.50 Outlets, Fiuues, Lights & Switches (1` 5 - Flat fee) $ 3.00 Above Items (All Others) .60 each Clothes Washer/ Dryer $ 2.00 each Range Receptacle $ 3.00 each Cook Top or Oven $ 1.50 each A%C, W`rudow Unit Receptacle $ 3.00 each Water Heater $ 3.75 each DishwashedGarbage Disposal $1.50 each Meter Loop & Service (includes Temporary cut4n) $15.00 each Temporary Saw Pole (T Pole) $15.00 each Reconnection of Service $15.00 each Reinspection Fee $35.00 each MOTORS: Up to but not including'/s hp $ 1.50 each hp avd less than 10 hp $ 250 each 101p&up to50hp $3.50each 50 hp and up $ 450 each Total Fee "* COMPLETE THIS SECTION FOR PLUMBING PERMITS NOTE: MINIMUM CHARGE ON PERMLT(S) IS $20.00 _.... ._ Description - Charge§ Quantity Fees _.....,—PERMIT ISSUE FEE .... $15:00.....,..,,....,, Fihaures/Drains/Traps $$ 3.75 each -Sewer (New, Repair, or Replacement) $ 750 each ``Septic Tank/Seepage Pit/Diain Field $15.00 each WaterHeater $ 3.75 each Gas PT System (1-4 outle[r,; flaifee) .$ 7.50 Gas Piping System (over 4 outlets -each) $ 150 each ' Installation, Altecatioa or Repair of Water Piping and/or water _ Tag. Equipment ........... $ 7.50 each ..._ RepaidAh mation - Drain or Vent $ 7.50 each Each Vacuum Breaker/Backflow Protection "- Eacli One (1-5) $ 3.75 each ' _ Each Ode (Over 5) $- 2.25 each Reinspection Fee $35.00 each Total S:%CPSLmaNSPECr10N DIV ONZ pint onsU4P�d Appl adez 1129DSA. ... — D4015WillbeinCtAllCaVIIy Ex;S};nJ (�n�1 ®%EXi67ingV UGnf$ /` IIVen•15 N `CTLI-a4�4S��.�OGFI�I ISz4 jm GFA1 I C 1�xf�RC.rs*/a 6661 LA61LLS 5erv,u Cen-zr Pd Box 577cU WUSs r, -cYa5 q75" TALL 6.4D( �Te 1: aIi- I16-)50d HVAC Plane for Maj'6 6r;Y �gjr Vent fan Araw1h roof Page 1 Commercial Heat Loss and Heat Gain Calculation 2/26/2006 Report Prepared By: LABILLS Service Center PO Box 57726, Webster, TX 77598 TACL B2612C Tel: 281-996-9500 For: Kitchen Main 101 Grill & Bar 101 East Main LaPorte, TX 77572 Design Conditions: Houston Latitude: 29: Time 4:00 PM Indoor: Summer temperature: 75 Winter temperature: 72 Relative humidity: 50 Total Cooling Load: Sensible: Latent: Total Heating Load 90,197 BTUH ( 7.5 tons) 76,335 13.862 23,081 BTUH 0 Outdoor: Summer temperature: 95 Winter temperature: 33 Summer grains of moisture: 113 Daily temperature range: 18 HVAC-Calc Commercial 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calwlations are estimates only, wwal locos may vary dua to waatbr and ronsaomion ddlerances. Page 1 Commercial Heat Loss and Heat Gain Calculation 2126/2006 Report Prepared By: LABILLS Service Center PO Box 57726, Webster, TX 77598 TACL B2612C Tel: 281-996-9500 For: Dining Room Main 101 Grill & Bar 101 East Main LaPorte, Texas 77572 Design Conditions: Houston; Latitude: 29; Time 4:00 PM Indoor: Outdoor: Summer temperature: 75 Summer temperature: 95 Winter temperature: 72 Winter temperature: 33 Relative humidity: 50 Summer grains of moisture: 113 Daily temperature range: 18 Total Cooling Load: 126,374 BTUH ( 10.5 tons) Sensible: 57,682 Latent: 68,692 Total Heating Load: 95,747 BTUH HVAC-Calc Commercial 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load dalW latims we estimates only. Actual loads may vary tlus 10 vroamer eM CwstnKtion dieeianaas City of La Porte 1-1 604 W Fairmont PkN,,, I.Porte, Tx 77571�: (281)470-5073 INSPECTION LINE:(281) 470-5130 ****PLUMBING PERMIT**** ---------------------------------------------------------------------------- Application Number . . . . . 06-00000398 Date 3/31/06 Property Address . . . . . . 101 E MAIN ST UB HCAD Number . . . . . . . . . 023-256-081-0002 Alternate Search Method . . . Application type description REMODEL, RETAIL STORE/CUSTOMER SERVICE Subdivision Name . . . . . . LA PORTE Property Use . . . . . . . . Property Zoning . . . . . . . MAIN STREET DISTRICT Owner Contractor ------------------------ ------------------------ SALTERRY INC LEW WIGGS 2005 YORKTOWN CT 4638-A LAIGLE RD SEABROOK TX 77586 MANVEL TX 77578 (832) 969-7360 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING PERMIT Additional desc NEW PLUMBING -RESTAURANT Sub Contractor BROCK PLUMBING Permi Fee . . . . 163.50 Issu Date . . . . 3/31/06 Valuation . . . . 0 Exp' ation Date . . 9/27/06 Qty Unit Charge Per Extension BASE FEE 15.00 27.00 3.7500 EA PL - FIXTURES/DRAINS/TRAPS 101.25 1.00 7.5000 EA PL - SEWER-NEW,REPAIR,REPLACE 7.50 2.00 3.7500 EA PL - WATER HEATER 7.50 1.00 7.5000 EA PL - GAS SYSTEM (1-4 OUTLETS) 7.50 4.00 1.5000 EA PL-GAS OUTLETS,OVER 4 (EA OUT) 6.00 1.00 7.5000 EA PL - WATER PIPE/TREATING EQUIP 7.50 1.00 7.5000 EA PL - REPAIR/ALT.-DRAIN OR VENT 7.50 1.00 3.7500 EA PL-VACCUM BREAK/BACKFLOW <6 3.75 ---------------------------------------------------------------------------- Special Notes and Comments 1. AS PER PRINTS & NOTES 2. CALL FOR INS PECTION 3. UNLOAD ALL MATERIAL & EQUIPME NT ON THIS SITE NOT R.O.W. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 163.50 163.50 .00 .00 Grand Total 163.50 163.50 .00 .00 --------------- --/,� ------------------------ Signaibur -,ef 6ontract&f or authorized agent ilding Official or authorized agent Dat Da 0 ` • PERNffr APPLICATION Biding Mechanical City of La Porte Established 1892 281-470-5073 *EElectrical °Phmnbing " •(See back of form) Owner's Name: Phone: Address: Streetcity zip5, Contractor' O C L f C_ G Phone: Address: Street City zip. Engineer «r"f �►/old%„ .. r . - Valuation: Describe -Work For City Use Only Occupancy Type Flood Zone Class Work Sq- Ft Construction Type Use Zonp� # Stories Parking Rea Commensal Buildings Plans 0&-Fire Marsbal Approval P Checked/Approved for Issuance By Date CE: Special Conditions: Taxes HCAD Permit woo �RV Permit 604 W. Fairmont Pkwy. • La Porte, Texas 77571 • (281) 471-5020 COMPLETE THIS SECTION FOR ELECTRICAL PERMITS:: NOTE: MINIMUM CHARGE ON PERMIT(S) IS $20.00 Description Charges Quantity Fees' PERMIT ISSUE FEE $7.50 $7.50 Outlets, Fib, Lights & Switches (la 5 — Flat fee) $ 3.00 Above Items (All Others) .60 each Clothes Washer/ Dryer $ 2.00 each Range Receptacle $ 3.00 each Cook Top or Oven $ 1.50 each A/C, Window Unit Receptacle $ 3.00 each Water Heater $ 3.75 each ` Dishwasher/Garbage Disposal $ 1.50 each Meter Loop & Service (includes Tempormy cut in) $15.00 each Temporary Saw Pole (T Pole) $15.00 each Reconnection of Service $15.00 each Reinspection Fee $35.00 each MOTORS: Up to but not including V, hp $ 1.50 each Y2 by and less than 10 hp $ 2-50 each 10 lip & up to 50 hp $ 3.50 each 50 hp and rip $ 4.50 each �'Total,Fee'• COMPLETE THIS SECTION. FOR PLUMBING, PERMITS V NOTE: MINIMUM CHARGE ON PERMIT(S) LS $20.00 Description Charges Quantity Fees PERMIT ISSUE FEE $15.00 1$ 5.00 Fhau es/Drains/Traps $ 3.75 each d- 7 Sewer (New, Repair, or Replacement) $ 7.50 each P Septic Tank/Seepage Pit/Drain Field $15.00 each 6�) Water Heater $ 3.75 each Gas Piping System (1-4 outlets, flatfee) $ 7.50O Gas Piping System (over 4 outlets -each) $ 1:50 each Installation, Alteration or Repair of Water Piping and/or Water / Treating Fquipmem $ 7.50 each Repair/Alteration — Drain or Vent $ 7.50 each / Each Vacuum Breaker/Backflow Protection Each One (1-5) $ 3.75 each Each One (Over 5) $ 2.25 each Reinspection Fee $3.5.00 each Total . S'SOPS.h.=WgSPWHONDMSIONVagia4=%BXg Pc-i[APPI 50411M5-dw City of La Porte ,604 W Fairmont Pkr t La Porte, Tx 77571-) (281)470-5073 INSPECTION LINE:(281) 470-5130 ****ELECTRICAL PERMIT**** ---------------------------------------------------------------------------- Application Number . . . . . 06-00000398 Date 3/24/06 Property Address . . . . . . 101 E MAIN ST UB HCAD Number . . . . . . . 023-256-081-0002 Alternate Search Method . . . Application type description REMODEL, RETAIL STORE/CUSTOMER SERVICE Subdivision Name . . . . . LA PORTE Property Use . . . . . . . . Property Zoning . . . . . . . MAIN STREET DISTRICT Owner ------------------------ SALTERRY INC 2005 YORKTOWN CT SEABROOK TX 77586 Contractor ------------------------ LEW WIGGS 4638-A LAIGLE RD MANVEL TX 77578 (832) 969-7360 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL PERMIT Additional desc ELECTRICAL ON NEW BUSINESS Sub Contractor ANSOM CONCEPTS Permit Fee . . . . 120.50 Issue Date . . . . 3/24/06 Valuation . . . . 0 Expiration Date . . 9/20/06 Qty Unit Charge Per Extension BASE FEE 7.50 1.00 3.0000 EA EL - OUTLETS,SWITCHES (1ST 5) 3.00 115.00 .6000 EA EL - OUTLETS, SWITCHES (OTHER) 69.00 4.00 3.0000 EA EL - A/C, PLUG-IN UNITS 12.00 1.00 1.5000 EA EL-DISWASHER/ GARBAGE DISPOSAL 1.50 1.00 15.0000 EA EL - METER LOOP & SERVICE/TCI 15.00 5.00 2.5000 EA EL - 1/2 HP AND UP TO 10 HP 12.50 ---------------------------------------------------------------------------- Special Notes and Comments 1. AS PER PRINTS & NOTES 2. CALL FOR INS PECTION 3. UNLOAD ALL MATERIAL & EQUIPME NT ON THIS SITE NOT R.O.W. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited -------------------- Due ----------------- Permit Fee -------------------- Total 120.50 120.50 .00 .00 Grand Total 120.50 120.50 .00 .00 ---------------------------------------------------------------------------- Signature of Contractor or Authoriz Agent I D'L� 3 �- Approved by Building Offici thorized Agent Date PEWWr APPLICATION Porte Established 1892 281-470-5073 "Bledlical Subdivision Blocic Ta=s Street - .. HCAD Residenfkd'ddvewayte-m fee: �o' ' T Plan CheckFem_ *Plambing T.PnIta.Texas77571 • (281)471-5020 COMPLETE THIS SECTION FOR ELECTRICAL PERMITS:: NOTE: M WaW CHARGE ONPERMI'T(S) IS $20.00 . Description Charges Quantity Fees PERMIT ISSUE FEE Outlets, Fixtures, Lights & Switches (14 5 — Flat fee) Above Items (All Others) Clothes Washer/ Dryer Range Receptacle Cook Top or Oven A/C, Window Unit Receptacle Water Heater DishwashedGarbage Disposal Meter Loop & Service (fnchrdes Temporary cut -in) Temporary Saw Pole (T Pole) Reconnection of Service Reinspection Fee MOTORS: Up to but not including %: hp %by and less than 10 hp 10 hp & up to 50 hp 50 by and up $7.50 $ 3.00 .60 each $ 2.00 each $ 3.00 each $1.50 each $ 3.00 each $ 3.75 each $ 1.50 each $15.00 each $15.00 each $15.00 each $35.00 each $ 1.50 each $ 2.50 each $ 3.50 each $ 4.50 each Total Fee :^. COMPLETETHISSECPIONFOR PLUMBING PERMITS NOTE: mDmviUM CHARGE ON PERMITS) LS $20.00 Description :.; Charges. Quantity Fees PERIri1TISSUEFEE '.. $15:00 Fixftues/Drains/Traps $ 3:75'each` Sewer (New Re 7 orRepTacement) $ 7.50 each ;..:..,_. Pro . ...:... , Septic Tank/Seepage PWD'iain Field' $15.00 each WaterHpater $ 3.75 each 0a"sPiping,System(1-4oudets;-J&2f*) $ 7.50 Gas Piping System (over 4 outlets -each) $ 1.50 each __.,..,Installation, Alteration or Repair of Water Piping and/or Wafer Treating Equipment $ 7.50 each >_. _.. Repa&Alteration — Drain or Vent $ 7.50 each Each Vacuum BreakerBaddlow Protection "Fae]i Oiie (15) $ 3.75 each Each One' (Over 5) $ 225 each ::. Peinspection Fee $35:00 each Total .: _...., S:ICPS6 WSPEMONDIVMON%.p..d—Udg Pemi[ApAside2 il=5-doc $7.50 . 15.00 (281)470-5073 City of La Porte 604 W Fairmont Pk%n- La- Porte, Tx 77571 ` INSPECTION LINE:(281) 470-5130 ****BUILDING PERMIT**** ---------------------------------------------------------------------------- Application Number . . . . . 06-00000398 Date 3/17/06 Property Address . . . . . . 101 E MAIN ST UB HCAD Number . . . . . . . . . 023-256-081-0002 Application type description REMODEL, RETAIL STORE/CUSTOMER SERVICE Subdivision Name . . . . . . LA PORTE Property Use . . . . . . . . Property Zoning . . . . . . . MAIN STREET DISTRICT Application valuation . . . . 60000 Owner Contractor ------------------------ SALTERRY INC ------------------------ LEW WIGGS 2005 YORKTOWN CT 4638-A LAIGLE RD SEABROOK TX 77586 MANVEL TX 77578 (832) 969-7360 -------------------------- Structure Information 000 000 ----------------- Construction Type . . . . . METAL FRAME (TYPE III) Occupancy Type . . . . . . BUSINESS Other struct info . . . . . FLOOD ZONE X ---------------------------------------------------------------------------- Permit . . . . . . BLDG PERMIT -COMMERCIAL REMODEL Additional desc . . REMODEL Permit Fee . . . . 447.50 Plan Check Fee 223.75 Issue Date . . . . 3/17/06 Valuation . . . . 60000 Expiration Date . . 9/13/06 Qty Unit Charge Per Extension BASE FEE 387.50 10.00 6.0000 THOU BLDG - 50,001 - 100,000 60.00 ---------------------------------------------------------------------------- Special Notes and Comments 1. AS PER PRINTS & NOTES 2. CALL FOR INS PECTION 3. UNLOAD ALL MATERIAL & EQUIPME NT ON THIS SITE NOT R.O.W. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ---------- Due ---------- ----------------- Permit Fee Total -------------------- 447.50 447.50 .00 .00 Plan Check Total 223.75 223.75 .00 .00 Grand Total 671.25 671.25 .00 .00 ------ ----------------------------------------------- �� i (SI NATURE OF CONTRACTOR OR AUTHORIZED GENT (APPROVED BY BUILDING OFFICIAL OR l7l� 0•* M 0•+ 223.75 + 447.50+ 671.250* LL ��eTO Fes. `i PERIVITT APP ICATION Bmldmg 1 Project Address Subdivision Owner's Name:a�e Aii&m-- Street r L Mechanical RECEIVED RECEIVE. FEB 0 9 2006 4*44 RECEIVED City of La Por/teo 9 2006 Established 1892 CRY 281-470-5073 *Electrical *(See back of form *Phnnbing Street City zip Building Use: O S V ��OS Yayvec: - ;':: $q: Footage: L o o. `T Stories_ Valuation Desmi>e Work For City use only, Occupancy TypeWort _ FloodZone /� : is S4•.,. construction Type :3 Use Zone. esReq . . 69 Commercial Buildings Plans On -Fire Marshal App Checked?Anvmved �l'ssuance Taxes u Residential'drivewaytieinf �✓ J3 1 6 s Permit No. 1 Permit Fee �' µ 7 �� � Ptan Check Fee. 2 2 �5 ? s:�crs�v>��da�n�lassos� 604 W. Fairmont Pkwy. • La Porte, Texas 775t 0 (281) 471-5020 COMPLETE THIS SECTION FORELECTR NOTE: M NINf M CHARGE ONPMd IT( Description . Charges Al PERMIT ISSUE FEE Oatlets, Fixtures, Lights & Switches (1s` 5 — Flat fee) Above Items (Alt Others) Clothes Washer/ Dryer Range Receptacle — Cook Top or Oven VC, Window Unit Receptacle Water Heater Dishwasher/Garbage Disposal Meter Loop & Service (includes Temporary cut -in) Temporary Saw Pole (T Pole) Reconnection ofService Reinspection Fee MOTORS: Up to but not including %hp hp and less than 10 hp 10hp&up to50lip 50 hp and up Fees $7.50 $7.50 $ 3.00 60 each $ 2.00 each $ 3.00 each $1.50 each $ 3.00 each $ 3.75 each $1.50 each $15,00 each $15.00 each $15.00 each $35.00 each $ 1.50 each $ 250 each $ 3.50 each $ 4.50 each Total Fee COMPLETE THIS SECTION FOR PLIAMING PERM[TS NOTE- MROMUM CHARGE ON PERMIT(S) IS $20.00 Description Charges Quantity Fees —PERMIT ISSUE FEE Fixtures/Drains/Traps $ 3.75 each Sewer (New, Repair, orReplacemerrt) $ 750 each Septic TanVSecpage PWPiaig Field $15.00 each Water Heater $ 3.75 each Gas Piping System (1-4 outlets _flatfee) .$ 7.50 Gas. Piping System (over 4 outlets -each) $ 150 each - InstallatioA AIieratioil or Repair of Water Piping and/or Water Treating Fgmpment $ 7.50 each, Repair/Alteration —Drain or Vent $ 7.50 each. Each Vacuum BreakerBackflow Protection FachOne (I-5) $ `3.75each " Each One (Over 5) $ '2:25 each ._ ... Reinspecfion Fee $35,00 each Total .. S_ICPSBaze1FNSPECTIONDIVSSFON{7nspeclions�BldgPermit Appl side211=5.dw T ADDRESS: OWNER'S NAME: PROJECT TYPE: COADIERCIAL PLAN REVIEW COVER SHEET e HCAD#: 6a3 - as 6 - (INTERNAL USE) NEW: 00O2 /o/ Ail �yri7� f 6sj-.� FLOOD ZONE: Ov -i,o� Y/N SUB /DATE RETURNED .*. r�cv • (Appllcable on Demo, Addn, or Remodel) 4& "'"' PR019F OF [.iTm (Applicable to Comm. Or Ind.) . R (If yes, permit cannot be issued.) (If yes, permit cannot be issued.) M nnn utcnaffFIfEEBPBr4 �M (If yes, figure fees. If no, use w/s form to explain why they are not.) TAXES UP TO DATE?: 0KG DATE OF REVIEW: of - a 1= O 6 INSPECTOR: T" C, N ITEMS NEEDED FOR ISSUANCE OF PERMIT: 'Ill: - CURRENT INSURANCE CERT. (if applicable) OK rwhe w o9x 7 I • �.3ii � t I OWNER OR CONTRA OR NOTIFICATION DATE TEWE NAME OF PERSON CONTACTED / / SACPSb=\INSPECRON DMSION\laipectj n \COML PLAN COVER SHU7.doc Rev. -0(, 0 rl. I .f INSPECTION SERVICES BUILDING PERMIT CHECKLIST (COMMERCIAL) Job Address: f o /%%A/.1/ HCAD#: C%,23 —,?, .S (o — O V _ 0o O 2 Owner Name: 70- e- 6f rfv $ h !. Flood Zone: iC Type of Work: New Date Received in Inspections: 2 - 9 -C ra // p Legal Description: of5 i- f �//� Zoning:y D dA,_q Allowable Use(DOR N Street/Alley Closing Action? Ord. #s: Complete and accurate construction drawings (all phases) are one of the most important steps in completing your project. They will be used to cost out the job, get estimates from any subcontractors, show details in legal documents, and to obtain necessary permits. FORMAT Survey of Property / (SBC 104.2.5))44)Ye No Certified S' Ian to Scale indicating:/ (Dev Ordinance 1No required by PlanningDepartment) (Appendix E) • N Arrow (Dev Ordinance 1No (Appendix E) • 1 existing & proposed construction (Dev Ordinance 1No(Appendix E) • 1 required building setback lines (Dev Ordinance 1No (Appendix E) Easements/Alleys, Streets (sho applicable) (Dev Ordin No _(tlpp n ix E) • Distance for propose rudure to propy �me�s (Dev Ordinance 1444) Yes or No /,, (Appendix E) ti Commer I - Residential Lew Wiggs General Construction 4638 A Laigle Road Manvel, Texas 77578 281 489 1446 832 969 7360 Inspections Division Building Permit Checklist Page 2 �Z6nii4g-Pefinit—�?ij!�� r - F NB - 4 Yes or No e Yes or No (CLP Resolution) Yes or No o (City Ord 106-141) Yes or No c) (City Ord 106-141) Yes or No rn t A Request *T ea a--G�� „�a (City Ord 106-141) -Yes or No Fill Dirt Permit (if ppli hIe)- (City Ord 1444-A) Yes or No r--= ? :b D rmitiagpksa>�1e)— , o (City Ord 1501-R5) Yes or No FI d D ahi DevelopnientPem*- A -v (City Ord 194-63) Yes or No ® (Ord 759-F) Yes or No -*--Gmpleted4letitl9n4o-liP nn fn j o Ryisting Wato_Te wepMains— (Ord 759-F) Yes or No (ex «f.aJ -1 r—Tr-) (City Ord 74-121(c) Yes or No 0 •�struction Drawings with Engineer's Seal (if applicable) •—Founds on lans — i✓e� (State Law) es (State Law) s r No or No tructural-FramingP}an-- Mcco •• Fxtel;;o Pl — No lestieai-Brawings,� --W _s P-lumhingBrawingsw..-j o :,. eehanieal-Drawings-,-) I ej k Drainage 4an- o .'• Qlnh FIeyatjgn-(ifappfigbfe) .-r o (State Law) Ye or No (State Law) Yes or No (State Law) Yes r No (State Law) Yes o No (State Law) Yes. or No State Law Yes or, o (State Law) Yes DIVISIONUnspections\Bldg P Checklist ComlNovOSdoc r MINOR DEVELOPMENT SITE PLANS BUILDING PERMIT RELEASE FORiVI Development Name: I O l Gl.& �Qi✓ Address: I D I E. Mavn. S - RECEIVE® W!;P'EGTJOKJS 3-/S-D 6 CLP Project No. ii6 - 912 4 % Date Project Reproducible Received: 3 - 12 —D Date Reproducible is Forwarded to Director for Signature: 3 - /,--9 Date Reproducible is Filed in Drafting Div.: Date Release Form Provided to Inspection Services Div.: 3 — / F4� The site plan for the proposed project has been approved -and released by the Planning Department. The project is now eligible for the issuance of construction permits once all applicable code, regulations, and fees have been satisfied. PLACE COMPLETEDRFrEA EFORMINCONSMUC77ONJOBFILE S:\CPS =Unspectfons\SUE PLAN RELEASE SR FORMdoc I01-2000 Rcv. RC/ QUALITY NOTICE THE FOLLOWING DOCUMENT(S) REFLECT THE POOR QUALITY OF THE ORIGINAL DOCUMENT(S) a u n o a, d z 0 m s V U AJ a 0 c _ 0 o+ c w v 0 Q � c 'a a� In m N 0 D 0 C N � 3 a �O 0 ` roE Q i Q. 0 t a)C W L O F- :r, O C O E T w O C 3 C 0 0 J 0 y 0 Q 1 W Z a) 7 N L In W I— O T O y. T a Em y rc'i7ED r,.- 'VOL. 83 PG. 345 HARRIS COI,..�'f DEED RECORDS.- pd� rat: under Copyright Laws, Title 11 United States Code 101 and 102. NI violators will be prosecutad to hex ent of the law. This survey is being provided solely for the use of the recipients named herein; and no license has no, created, express or Implied, to cgpy the survey except as Is necessary In conjunction with the original transaction; which shall take place within thirty (30) days from the date adjacent to the signature line hereon. Bearings based on recorded plat. Found or set Iron rods at all comers. - D� 6 eR0goy./9' ° y �o r • u ° .67. ° a ° aeA o IIL N I II ! 4a I s I �. ..� °.< � °. `gym•, r Z --------------- s Q H N N VIRGINIA C1 r O i RECEaVED SURVEY LOTS 1 ' — 4 & 22 — 26, BLOCK 181, LA PORTE HARRIS COUNTY, TEXAS Scale: 1-30' ` Date: 10/07/05 THIS PLAT"IS_;AN'ACCURATE REPRESENTATION OF THAT Revised: SURVEY MADE •ON,I�THE GROUND UNDER MY SUPERVISION. Survey By: B.S. Drawn, By: C.H. THERE ARE Nd APPARENT ENCROACHMENTS OR CONFLIC��jjgg ACROSS PROPERTY' LINES AT THE TIME OF THIS SURVEYti.C-�1v� For: JOE BERTUGRIA EXCEPT AS SHOWN HERON. t� �ol O Purchaser: Job No. 34703 BILLY SHANKS R.P.L.S. #1821 !t, 1414 VECREST LN. 281-488-1486 L. SHANKS HOUST N. TEXAS 77062 FAX 281-488-5526 Will BP100I01 CITY OF LA PORTE 3/01/06 }Land Master File Inquiry;`) 17:28:04 i HCAD Number 023-256-081-0002 Alternate Search Method Location ID nbr 31476 Street address 101 E MAIN ST UB CLP LA PORTE TX 77571 Subdivision . . . . : LA PORTE Current owner . . . : PARKER THOMAS E & BETTY J Person/Company P 717 YALE LN Phone DEER PARK TX 775366209 Plat/Book/Page . . : Zoning . . . . . . : MS MAIN STREET DISTRICT Variance . . . . . . Fire zone . . . . . Press Enter to continue. F3=Exit F4=Appl inq F13=Disp sections F15=Valuations F10=Legal desc More... F12=Cancel F17=User defined BP100I03 CITY OF LA PORTE P' ;d Legal Description Inqui. ` Property 101 E MAIN ST UB CLP 023-256-081-0002 Legal Description LTS 1 2 3 & 4 BLK 181 LA PORTE Press Enter to continue. F3=Exit F12=Cancel 3/01/06 17:28:17 BP100I01 CITY OF LA PORTE Land Master File Inquiry HCAD Number 023-256-081-0022 Alternate Search Method Location ID nbr 6234 Street address 101 E MAIN ST LA PORTE Subdivision . . . . LA PORTE Current owner . . . PARKER BETTY J 717 YALE IN DEER PARK Plat/Book/Page CLP TX 77572 3/01/06 17:40:47 Person/Company P Phone TX 775366209 Zoning . . . . . . GC COMM - GENERAL Variance . . . . . . Fire zone . . . . . Press Enter to continue. F3=Exit F4=Appl inq F10=Legal desc F13=Disp sections F15=Valuations More... F12=Cancel F17-User defined BP100I03 CITY OF LA PORTE 1"NI Legal Description Inqui> Property 101 E MAIN ST CLP 023-256-081-0022 Legal Description LTS 22 THRU 26 BLK 181 LA PORTE Press Enter to continue. F3=Exit F12=Cancel as�Xizs x �_ l5J 625 3/01/06 17:27:05 " MAP OR PLAT RECORDED^ C-iVOL. 83 PG. 345 HARRIS COU'k r 'DEED RECORDS. X �• , This original work is protected under Copyright laws, Title 17 United States Code 101 arLX102. All violators will be prosecuted to the fullest extent of the law. This survey is being provided solely for the use of the recipients named herein, and no license has y been created, express or Implied, to copy the survey except as is necessary in conjunction with the original transaction, which c shall take place within thirty (30) days from the date adjacent to the signature line hereon. N Bearings based on recorded plat. Found or set Iron rods at all comers. Co 1-1 O °a B19 6 O d O° r� ° a ° a ° ee.1a O I I � ~ I fxd; I.R. 0 ° p �r�Rlll .° e 0 N Z u ° ° 8 ° a r -1 q U + --------------- r H N U I �.iT: _..- - .. - Fed• I•� RECEIVED APIGNA - SURVEY LOTS 1 - 4 & 22 - 26, BLOCK 181, LA PORTE HARRIS COUNTY, TEXAS Scale: 1=30' Dote: 10/07/05 Revised: Survey By: B.S. Drawn By: C.H. For: JOE BERTUGRIA I Purchaser: THIS PLAT IS AN ACCURATE REPRESENTATION OF THAT SURVEY MADE ON THE GROUND UNDER MY SUPERVISION. THERE ARE NO APPARENT ENCROACHMENTS OR CONFLICTS, E\'4 E13 ACROSS PROPERTY LINES AT THE TIME OF THIS SURVEIL;.' EXCEPT AS SHOWN HERON. 9 1fl�6 F tv6 p Job No. 34703 BILLY SHANKS R.P.L.S. #1821 BILLY L. SHANKS 1414 VECREST LN. 281-488-1486 uAIMIT N TFYdC 770A') FAX 281-488-5526 ,? ;z o o G f, < ;2,- Poo/- 3 W, 1' 7 , i-- R R f of .7 A T r_ s1 i 5 //-"A T. o f�v-•A / o t 14) s T< t, C- Tv Je, -W7 . ,�--I�t TW .s p (i T S . o✓ --� 13vs1cl Fae DwjsWm ix W11 _u Ala d6T $ lleo'va;l � MILLS 6erv,re Cen, r PO Box 577ou wck5 r, TKas 1751f TACL 71: ol- M-9500 `6x4 je�GFtMt 1 r 1 -0 1� r r CX S��nq uE» A!I vents WTLI—a+�451u GFA IF APPROV ANS A M0X' { D, A NEW BMI Tr TO THE CITY IS REQUIRED PR OR TO THbHANGE DCRING HVAC Plan for Main 1016r;V agar vtnt fan 1�ro*roof AnrruJAXgroffi rage i of z Texas Department of Licensing and Regulation Architectural Barriers Project Registration Confirmation Page Wednesday. February 22, 200S EABPRJA6609845 PERSON FILING FORM Name: Joseph Bertuglia Email. lbertuolia@hou8ton.ff.com Phone: 713-294-SWB Project Name: Main 101 Gfii and Bar Project Address: Main 101 Grill and Bar 101 E. Main St. La Porte, TX 77571 County: Harris TENANT Name: Main 101 Grill and Bar Phone: 281-4704HU Tenant Address: 101 E. Main SL, Le Porte, TX 775?1 Contact Name: Joseph Bertuglia Phone: 713-29443668 Contact Address: 2005 Yorktown CL, Seabrook, TX 77686 BUILDINGIFACILITY Name: Main 101 Grill and Bar FACILITY Owner. Joseph Bedglia Phone. 713.2944w8 Owner Address: 2005 Yorktown Ct., Seabrook, Tx 77686 Contact Name: Joseph Bertuglia Phone: 713-294-8868 Contact Address: Some DESIGN FIRM Name: (Caren Hamilton Phone: 281-328-0074 Firm Address: PO Box 705, Seabrook, TX 775M Designer Name: Karen Hamilton Email: Karen@karenhamiilon.net Type of License: Other Ucense Number. PROJECT DESCRIPTION Data Construction Documents Issued: 02/22/2006 Start Date: t12120W Completion data: 04=W Estimated Cost: $80,000.00 Type of Work: Renovation/ABeration Does this building(*) have more than one level? No Are there any elevators, escalators, or platform ilffs In this building? No Type of Funds; This project Is privately funded, on private land for private use. Slate Lease No.: Scope of Werk: Convet existing Tea Room into Full service restaurant I will submit this AS Confirmation Page with a complete set of construction documents and applicable fees to a Registered Ac ooWbility Specialist (RAS) or Contract Provider. I hereby notify the Texas Department of Ucensing and Regulation of the described project and of my Intent to perform, or cause to be performed, all services necessary to design said project in accordance with the previsions of Texas Government Code, Chapter 469.1 certify that I am the registered design professional with overall responsibility for the design of the project and whose seal Is afted to the construction documents. I hereby notify the Texas Department of Ucenakig and Regulation of my intent to comply with the provision of Texas Government Code, Chapter 469. rorr.2R• ror Signature of RAS OR Name of CP RAS/CPB Date Construction Documents Received by RAS r L js Fo Enter Another Project Print this Page I ��p6 htip://www.license.state tx.us/abprojectregistrabion/ABProjRegFormVerification.aspx?strP... 2W2006 nDrrUJAWUnn k L) rage L Or L Texas Department of Licensing and Regulation Architectural Barriers Project Registration Confirmation Page Wednesday, February 22, 2006 EAEPRJA6809845 PERSON FILING FORM Name: Joseph Bertha Small: jbertuglia@houston.moorn Phone: 713-204-MM Project Name: Main 101 Grill and Bar Project Address: Main 101 Grill and Ber 101 E. Main St. La Porte, TX 77571 County: Hams TENANT Name: Main 101 Grill and Bar Phone: 281-470-8484 Tenant Address: 101 E. Main SL, La Porte, TX 77571 Contact Name: Joseph Bertuglia Phone: 713-2948688 Contact Address: 2005 Yorktown CL, Seabrook, TX 77586 BUILDINGIFACILITY Name. Main 101 Grill and Bar FACILITY Owner: Joseph Bertuglla Phone: 713-294.8888 Owner Address: 2005 Yorktown CL, Seabrook, Tx 77686 Contact Name: Joseph Bertuglia Phone: 713-294.8868 Contact Address: Same DESIGN FIRM Name: Karen Hamilton Phone: 281-328-0074 Finn Address: PO Box 705, Seabrook, TX 775M Designer Name: Karen Hamilton Email: Karen@karerthandlion.net Type of License: Other License Number. PROJECT DESCRIPTION Date Construction Documents Issued: 0?J22I2008 Start Date: 02=W Completion data: 042008 Estimated Coat: $80,000.00 Type of Work: Renovation/Alteradon Does this building(s) he" more than one level? No Are there any elevators, escalators, or platform tins in this building? No Type of Funds: This project Is privately funded, on private land for private use. State Lease No. : Scope of Work. Comet existing Tea Room Into Full service restaurant I will submit this AB Confirmation Page with a complete set of oonstruCWn documents and applicable fees to a Registered Accessibility Specialist (RAS) or Contract Provider. I hereby notify the Texas Department of Licensing and Regulation of the described project and of my Intent to perform, or cause to be performed, all services necessary to design said project in accordance with the previsions of Texas Government Code, Chapter 469.1 certify that I am the registered design professional with overall responsibility for the design of the project and whose seal is affixed to the construction documents. I hereby nobly the Texas Department of Licensing and Regulation of my intent to comply with the provision of Texas Government Code, Chapter 489. m Signature of RAS OR Name of CP RASfCP# Enter Another Project I Print this Page RR,. W r Date Construction DoctuW10, Received by RAS 9P, li'O <0�6 http:JJwww.license.state.tx.»s/abprojecfregisuudonlABProjRegFormVerificadoaaspx?&P... 2=2006 SUB TOTAL LOAD 120V LOAD 240V/1 SINGLE PHASE LOAD 240V/3 THREE PHASE LOAD 120V LOAD SPLIT A & B PHASE Calculated Loads Per Phase REPRESENTED IN AMPS Ansom Concepts 113840.6 33084 12528 68228.6 16542 90428.6 256.64 80756.6 68228.6 12528 68228.6 68228.6 16542 90428.6 68228.6 256.64 164.1 Page 1 of 1 F Page 1 Commercial Heat Loss and Heat Gain Calculation Report Prepared By: LABILLS Service Center PO Box 57726, Webster, TX 77598 TACL B2612C Tel: 281-996-9500 For: Kitchen Main 101 Grill & Bar 101 East Main LaPorte, TX 77572 Design Conditions: Houston; Latitude: 29; Time 4:00 PM Indoor: Summer temperature: 75 Winter temperature: 72 Relative humidity: 50 Total Cooling Load: Sensible: Latent: Total Heating Load: 90,197 BTUH ( 7.6 tons) 76.335 13,862 23,081 BTUH Outdoor: 2/26/2006 Summer temperature: 95 Winter temperature: 33 Summer grains of moisture: 113 Daily temperature range: 18 HVAC-Calc Commercial 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Losd "Wationa we asdmatas only. weal losds my vuy dw to wsaNrt and m Uwtion diff n s. Page 1 Commercial Heat Loss and Heat Gain Calculation 2/26/2006 Report Prepared By: LABILLS Service Center PO Box 57726, Webster, TX 77598 TACL B2612C Tel: 281-996-9500 For: Dining Room Main 101 Grill & Bar 101 East Main LaPorte, Texas 77572 Design Conditions: Houston; Latitude: 29; Time 4:00 PM Indoor: Outdoor: Summer temperature: 75 Summer temperature: 95 Winter temperature: 72 Winter temperature: 33 Relative humidity: 50 Summer grains of moisture: 113 Daily temperature range: 18 Total Cooling Load: 126,374 BTUH ( 10.5 tons Sensible: 57,682 Latent: 68.692 Total Heating Load: 95,747 BTUH HVAC-Calc Commercial 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load ukuWom "udmatss wly. a ,*' load, may vM' dus W wthw wn onmwc0a+ diff s . Limited Building Inspection Report for Asbestos -Containing Building Materials Main 101 Grill and Bar 101 E. Main Street LaPorte, Texas 77571 Prepared for: Mr. Joe Bertuglia 101 E. Main LaPorte, Texas 77571 C �WTY PROJECT NO: AESD-05-16 Prepared by: Austin Environmental, Inc. Environmental Consultants P.O. Box 832 Seabrook, Texas 77586 281-474-1131 1 December 19, 2005 RECEIVED REC�IV� FEB 0 9 2006 AUSTIN ENVIRONMENTAL, INC. P.O. BOX 832 sEABROOK TX 77805 (201) 474-1131 s • December 19, 2005 Mr. Joe Bertuglia Main 101 Grill and Bar 101 E. Main LaPorte, Texas 77571 AUSTIN RECEIV, ENVIRONMENTAL, INC. P.O. Box 832 Seabrook, Texas 77586 (281) 474-1131 RE: Limited Asbestos Survey for Main 101 Grill and Bar, 101 E. Main Street LaPorte, Texas 77571 Dear Mr. Bertuglia, On December 15, 2005, at your request, Mr. Stephen Dehlinger, a Licensed Individual Asbestos Management Planner, of Austin Environmental, Inc., conducted a limited asbestos survey of the future Main 101 Grill and Bar, 101 East Main, LaPorte, Texas, 77571 for the presence, location, and the condition of suspect asbestos -containing building materials (ACBM) prior to renovation activities. The asbestos inspection of Drywall Tape and Texture and 12' x 12' floor tile and mastic will satisfy inspection requirements of the State of Texas and local building officials for the proposed remodeling. The purpose of the limited inspection was to determine the presence and location of suspect friable and non -friable asbestos -containing building materials prior to disturbing drywall material along with floor covering. Renovation activities in the center of the building and restroom installation on site require this inspection. No other properties were tested. RECEIVE` FEB 0 9 2006 AUSTIN ENVIRONMENTAL, INC. P.O. BOX 832 SEABROOV, TX 77805 (281) 474-1131 December 19, 2005 Page 2 The federal National Emission Standard for Hazardous Air Pollutants (NESHAP) 40 Code of Federal Regulations (CFR) Part 61, subpart M, and the Texas Asbestos Health Protection Act and Rules (TAHPA) requires that prior to any renovation or demolition of a commercial or public building that it must be inspected for the presence of suspect asbestos -containing building materials (ACBM). The scope of work and services provided include: ♦ Field investigation and visual observations • Sampling of suspect asbestos -containing building materials that will be disturbed ♦ Analysis of suspect asbestos -containing building materials (ACBM) • Collect information on the friability of the asbestos -containing materials if present Suspect ACBM was physically handled to determine friability and bulk samples were obtained for analysis. The inspection involved sampling of nine (9) suspect asbestos - containing building materials and analyzing them under Polarized Light Microscopy with Dispersion Staining (PLM/DS), EPA Method 600/R-93/116. The PLM/DS results are attached to this report. SURVEY The survey was conducted on a homogenous -area basis. The survey homogeneous areas were the walls in the small office and restroom, the ceiling in the office and restroom and floor tile and mastic throughout. The State of Texas requires three samples to prove that the suspect material is free of asbestos. No other materials were tested. RESULTS All suspect building materials sampled and tested were determined to be None Detected for asbestos content. AUSTIN ENVIRONMENTAL, INC. P.O. BOX 832 SEABROOK, TX 77805 (281) 474-1131 a December 19, 2005 Page 3 RECEIVED "FR A 4 onnC Friable asbestos -containing material refers to material, which contains more that one (>1%) percent asbestos by weight and when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. Non -friable asbestos -containing material is any material containing more than one (1%) percent asbestos by weight and when dry, cannot be crumbled, pulverized or reduced to powder by hand pressure. All materials detected/uncovered during present or future renovations or demolitions that are not listed, as being sampled on the Chain of Custody Form and will be disturbed, must be sampled and analyzed prior to disturbance. All additional samples and assessments are to be conducted by property licensed individuals. New building materials should be addressed to ensure that they do not contain asbestos. Manufactures labels or material safety data sheets (MSDS) should be reviewed and documented to ensure that any asbestos containing building products are not used during future construction. LIMITATIONS This report only applies to the scope of work described herein. This report describes existing conditions at the time of services. Conditions of asbestos -containing materials may change as a result of damage, deterioration or other disturbance and may increase the potential for elevated fiber levels. This report applies only to accessible areas observed during our field services. Asbestos -containing materials may exist in concealed inaccessible enclosures, such as areas enclosed by permanent partitions, chases, shafts, equipment etc. Material locations and quantities may vary. RECEIVED FEB 0 9 2006 AUSTIN ENVIRONMENTAL, INC. P.O. BOX 632 SEABROOK, TX 77805 (281) 474-1131 i� December 19, 2005 Page 4 Although a good -faith effort was made to locate asbestos -containing building materials in the area within the scope of work, extensive destructive inspection and/or testing was not conducted due to the expense, potential exposure hazards and/or potential regulatory violations. All surfaces, paints, wire insulation, heat shields, electrical panels, fire rated doors and panels, furnishings, Heating Ventilation and Air Conditioning (HVAC) Systems, fixtures and similar materials and equipment were not sampled and analyzed due to safety concerns and expense. Inspection and testing for lead -based paint, PCB containing light ballast and/or other hazardous and/or regulated materials was not included in Austin Environmental Inc.'s survey. Roofing materials were not included in the scope of work of this limited asbestos inspection. Per the TDH TAHPR this document (asbestos survey report) may not be used as a design (specification) for asbestos abatement. Design and/or abatement air monitoring services were not included in Austin Environmental Inc.'s scope of work. Austin Environmental Inc. makes no warranty and assumes no liability for the inappropriate use or misuse of this document. We appreciate the opportunity to provide you with this limited asbestos survey. Should you need any further asbestos related services, please don't hesitate to contact us at (281) 474-1131 or (979) 229-4385. Sincerely, AUSTIN ENVIRONMENTAL, INC. Stephen E. Dehlinger Individual Asbestos Management Planner License No. 20-5548 Paul Dehlinger, R.S. Individual Asbestos Consultant License No. 10-5523 Asbestos Consultant Agency License No. 10-0313 FFR-- n . of ed P00 WOW RECEIVED FEB 0 9 2066 AUSTIN ENVIRONMENTAL, INC. P.O. BOX 932 SEABROOK. TX 77808 (281) 474.1131 r-_1 LJ �..i PLM REPORT Sieve Moody Micro Services, Inc. NVLAP Lab No. 102056 1510 Randolph, Suite 602 TDH License No. 30-0084 Carrollton, Texas 75006 (972) 446-9482 PAT ID # 102577 Client : Austin Environmental, Inc. Lab Job No.: x5B-10283 Project: Joe Bertuglla, Main 101 Grill and Bar Report Date: 12/1712005 Project # : AESD-05-16 Sample Date: 12115/2005 Identification: Asbestos, Bulk Sample -Analysis Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) EPA Method 600 / R-93 / 116 Page I of 2 On 12/162005, nine (9) bulk nnterial sarripla were submitted by Stephen Dehlinger of Austin Environmental, Inc. for asbestos analysis by PLM/DS. Copits of the lab data sheets are attached; additional information may be found therein. The results are surtmtanzed below: Sample Number Client Sample Description / Location Asbestos Content MG -IA Drywall, Texture, Compound, Storage Closet, South Wall None Detected - Drywall Material None Detected - Joint Cmpd / Texture MG-1 B Drywall, Texture, Compound, Storage Closet, North Wall None Detected - Drywall Material None Detected - Joint Cmpd / Texture MG -IC Drywall, Texture, Compound, Restroom, North Wall None Detected - Drywall Material None Detected - Joint Cmpd / Texture MG-2A Drywall, Texture, Compound, Storage Closet, Ceiling South None Detected - Drywall Material None Detected - Joint Cmpd / Texture MG-213 Drywall, Texture, Compound, Storage Closet, Ceiling North None Detected - Drywall Material None Detected - Joint Cmpd / Texture MG-2C Drywall, Texture, Compound, Restroom, Ceiling North None Detected - Drywall Material None Detected - Joint Compound None Detected - Texture MG-3A 12" x 12" Floor Tile (Off-white), Dining Room None Detected - Floor Tile None Detected - Yellow Mastic MG-3B 12" x 12" Floor Tile (Off-white), Restroom None Detected - Floor Tile None Detected - Yellow Mastic MG-3C 12" x 12" Floor Tile (Off-white), Kitchen None Detected - Floor Tile None Detected - Yellow Mastic RECEIVED CCCIVL J FEB 0 9 2006 FEB a 9nn PLM REPORT Steve Moody Micro Services, Inc. N V LAP Lab No. 102056 1510 Randolph, Suite 602 TDH License No. 30-0094 Carrollton, Texas 75006 (972) 446-9482 PAT ID # 102577 Client: Austin Environmental, Inc. Lab Job No.: x5B-10283 Project : Joe Bertuglia, Main 101 Grill and Bar Report Date: 12117/2005 Project # : AESD-05-16 Sample Date : 12115/2005 Identification: Asbestos, Bulk Sample.Analysis Test Method: Polarized Light Microscopy / Dispersion Staining (PLM/DS) EPA Method 600 / R-93 / 116 Page 2 of 2 On 12/1612005, nine (9) bulk material samples were submitted by Stephen Dehlinger of Austin Environmental, Inc. for asbestos analysis by PLM/DS. Copies of the lab data sheets are attached; additional information may be found therein. The results are summerimd below: Sample Number Client Sample Description / Location Asbestos Content RECEIVED FrP n a ')nn; CEIV' RT FEB 0 `� Z000 Theo samples were analysed by layers. Quantification, unless otherwise noted, is perfumed by calibratedvisual estimate. Results may not be reproduced except in full. This test report relates only to the samples tested. These test results do not imply endorsement by NVLAP or any agency of the US. Government. Accredited by the National Voluntary laboratory Accreditation Program fa Bulk Asbestos Fiber Analysis under tab%10205M6.CodeAnalyst : Erik Barnes Lab Director: Steve Moody Approved Signatory: ___ ___ _______ ____________ __________ flnrd yourmchoosirysI Moody Mien Ser Cka Steve Moody Micro Services, Inc. Bulk Asbestos Analysis Sheet TDH License No. 30-0094 EPA Method 600 / R-93 / 116 Client: Austin Environmental, Inc. Project : Joe Bertuglia, Main 101 Grill and Bar Project # : AESD-05-16 Lab Job# : x5B-10283 Sample # : MG-1 A Client Sample Description: Drywall, Texture, Compound, Storage Closet, South Wall Layer 1 Drywall Material PI M Faamina,im, Page 1 of 1 C u X +/. M Color / Pkochroisrrt Parallel Ref. Index I Perpendicular Ref. I .Extinction Sign of lElongationj Ilulose Fibers rlbbow high ypsum / Binders 9 Non�lbrow Prep(ueamKnt : mechanical separation Asbestos Content: None Detected -------------------------------------------------- Layer 2 DW Paper Facing PLM Fxamirutinn Components Llo�l Morphology Color / Pkoctuoism PanIICI Ref. Index Kolar Rcf. I= Bi Extinction Angle _� SI of Elongation ellulose Fibers Abbom highL Reytrcument : mechanical separation Asbestos Content : 'None Detected Layer 3 Joint Cmpd / Texture Stereoscopic Exam PI_M Fxamimtinn 117 Cobr Parallel Perpendicular Extinction Signor Corrrponenu X H—+/-- MoryMbgy_ I Pkochroism Ref. Index _ — Ref. Index Bircf AngleI Tale / Binders 10 Man -Fibrous I Prephrctrnent : mechanical separation Asbestos Content: None Detected ------------------------------------------------- RECEIV€D FEB 0 9 2006 RECEIVED FFR n LV VU Continents : Analyst: Erik Barnes Date Analyzed: 12/17/2005 j/1 Bulk Asbestos Client: Austin Environmental, Inc Project : Joe Bertuglla, Main 101 Grill and Bar Project # : AESD-05.16 lab Job# : x5B-10283 Sample # : MG-1 B Client Sample Description : Drywall, Texture, Compound, Storage Closet, North Wall Page 1 of 1 Layer I Drywall Material PI M Fxaminatitm Compon" )IOU Color Pkochroism Parallel Ref. Inckx Perpendicular I Ref. Index Bin:f .Extinction _ Arrgk Sign of Elongation eiluese Fibers rlDDons high sum / Binders 1 9 NoMlbroua Preptwitmem : mechanical separation Asbestos Content: None Detected -------------------------------------------------- Layer 2 DW Paper Facing PLM E: iwion Components % +/- MorpWo -- Color I Pkochroism Panikl Ref. Index Perpendicular Ref. Irdat I Bimf Extinction An Ie ��_� Si of Elon tion ellulose Fibers 1 _ ribborts hi h Pmpttreaanent : mechanical separation Asbestos Content: None Detected -------------------------------------------------- Layer 3, Joint Cmpd / Texture Stereoscopic Exam PLM Examination Color Parallel Perperdicular Extinction Sign of CompoxnuTI%OC Morptalo�y /Pleochroian Ref. Idex Ref Index Biref �—� Angk Elodonalette/Tale/Binders Non-Flbrous _ _�� Preyueatment : mechanical separation Asbestos Content : None Detected -------------------------------------------------- Comments: RECEIVED FEB 0 9 2006 RECEIVED FEB u 8 LUDO Analyst: Erik Barnes C(l. Date Analyzed: 12/17/2005 Ll/ Steve Moody Micro Services. Inc. Bulk Asbestos Analysis Sheet TDH Licarse No. 30-0084 EPA Method 600 / R-93 / 116 NVLAP lab No. 102056 Client: Austin Environmental, Inc. Project : Joe Bertuglia, Main 101 Grill and Bar Project # : AESO-05-16 Lab Job# : x5B•10283 Sample # : MG -IC Client Sample Description: Drywall, Texture, Compound, Restroom, North Wall Page 1 of 1 Layer 1 Drywall Material PLM Examination coinw=ts % +/- M Cobr / Pleochroisn Parallel Ref. Indnc Perpendicular Ref. Index Biref Extinction Angle e Sign of 02gnion Ilutose Fibers rlbborts high Pypsum / Binders NonJibrow Pmplmntment : mechanical separation Asbestos content: None Detected — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Layer 2 DW Paper Facing Stereoscopic Exam PLM Examination Color n Con onents X +/-I Morphology / Pleochroisrn R�Indea RP cf Idndu� I Angie Elongation allulose Fibers log rlbboro Prep%rcatment: Irechanleal separation Asbestos content: None Detected ------------------------------------------------ Layer 3 Joint Cmpd / Texture Stereoscopic Exam PI M Fmmimrim. Co unders % +/- M logy Color / Pkochroism I Parallel Rcf. Index Perpendicular Ref. Indexk�l � Extinction Angle Sign of El—tion I J Palette / Talc /CBI 1 Nonfibrous __ Prep/aeaunmt : mechanical separation Asbestm Content: None Detected ------------------------------------------------ REC��v Ep FEg 0 9 1p06 RECEIVEQ LU o inn Comments: Analyst: Erik Berries Very thin Texture layer. Date Analyzed: 12117/200l 5 ` 6 Steve Moody Micro Services. Inc. Bulk Asbestos Analysis Sheet TDH License No. 30-0084 EPA Method 600 / R-93 / 116 NVLAP lab No. 10203E Client: Austin Environrnentel, Inc. Project: Joe Bertuglla, Main 101 Grill and Bar Project # : AESD-05.18 lab Jot# : x5B-10283 Sample # : MG-2A Client Sample Description : Drywall, Texture, Compound, Storage Closet, Ceiling South Page 1 of 1 Layer 1 Drywall Material Stenwscopic Exam PI M F�nminnrinn Ology Color / Pleochroism Parallel Ref. Irdex Perpendicular RcL Irda Biref 'Extinction _ An a Sign of Elongatton liuloss Fibers rlbtwns hl h ypsum / Binders Nonfibrous Preytratmeru : mechanical separation Asbestos Content: None Detected -------------------------------------------------- Layer 2 DW Paper Facing Stereoscopic Exam PLM Fzaminarinn Components % N- MoryMloKy / Pkocluoisof m Reef I'cd'" RReefe.hdda Biter ExuI7tinction_I Ebb lion Iluloao Finara� —� rlbborg I high Prep( atmem : mechanical separation Asbestos Content : None Detected ------------------------------------------------- Layer 3 Joint Cmpd / Texture Stereoscopic Exam PLM Fxamirorirm Color ilel I Sign of omponenb % +/-I M /Pleochroism Ref.IndexI RPeef�ida Biref Angien Ebngmion �gldte // Tak /Binders 1 Non flo]oU -Fibrous : mechanical separation Asbestos Content : None Detected ------------------------------------------------- IVED 1 L� � •[ �VVU Comments : Analyst: Erik Bames f Date Analyzed: 12117/2005 %X7 Steve Moody Micro Services, Inc. Bulk Asbestos Analysis Sheet TDH License No. 30-0094 EPA Method 600 / R-93 / 116 Client: Austin Environmental, Inc - project: Joe Bertuglia, Main 101 Grill and Bar Project p : AESD-05-16 Lab lob# : x5B-10283 Sample H : MG-2B Client Sample Description: Drywall, Texture, Compound, Storage Closet, Ceiling North Layer 1 Drywall Material PLM Examination Page 1 of 1 Components % +/- M Color /Pkochroisn Pamlld Ref. lMu Perpendicular Ref. IrWex Bire! .ExtirxYion Angle Sign of Elongation Ilulose Fliers rtbborrs high ypsum / Binder p Nonlibrous Prep/brataw t : mechanical separation Asbestos Convent: None Detected -------------------------------------------------- Layer 2 DW Paper Facing PLM Examination CorlWonertts X +/- lo MorphogX— /P Ckochroisrrr Ref Index ndex Biref ExtinctionExtinctionESrgo ion lCallulose Fiber 1 _ rihbons Alph PmpAnslmem : mechanical separation Asbestos Content; None Detected -------------------------------------------------- Layer 3 Joint Cmpd / Texture PI M Fxaminarim, MI Color PRef.I Extinction Signof Comparcrtts X_ +/- Morpho ' /Pkocltmism Ref. Ref. hMu dex Ref. Index I Bvef An Ige I Elongation Uts /Talc / Bltrdsr 70 —� Non{Ibrous Prcpftrcamx" : mechanical Separation Asbestos Content: None Detected -------------------------------------------------- Comments: : Thin Texture layer. RECEIVED Analyst: Erik Bames / r Date Analyzed : 12/17/2005 �7 Steve Moody Micro Services, Inc. Bulk Asbestos Analysis Sleet Toll License No. 30-0094 EPA Method 600 / R-93 / 116 Client: Austin Environmental, Inc. Project : Joe Bertuglia, Main 101 Grill and Bar Project # : AESD-05-16 Lab Job# : x5B-10263 Sample # : MG-2C Client Sample Description : Drywall, Texture, Compound, Restroom, Ceiling North Layer 1 Drywall Material Stereoscopic Exam iaeV,axmrrnre Page 1 of 1 C % +/• M Color /Pleochroism ParaIIN Ref. Irrdea Perperdinslar Ref. Index Biref Extinction Angle Sign of El on ion liulose Fibers Abboro nigh ypsum / Binders 9 Non -fibrous Prephesurcnt : mechanical separation Asbestos Conten : None Detected -------------------------------------------------- Layer 2 DW Paper / Tape Stereoscopic Exam PI M Faamimrinn Ckocluoism erIrdaelar �AngleEbngation Components % +/- Mo hobg� / P Ref Index I Ref. Bic f Iluloss Flbana 1 rtbbom nl h Reytreatment : mechanical separation Asbestos Content: None Detected -------------------------------------------------- Layer 3 Joint Compound Stereoscopic Exam PI M F�mminaNm Color lel Signn of Components % +I- Mor�bgy_ / Pkoclwism Repf�lydas I Recta. Idndu Bire! I AnglExtinction Ebngmion cite / Talc I Binders 1 Noniibrous Preproearmcm : mechanical separation Asbestos Content: None Detected -------------------------------------------------- Layer 4 Texture Stereoscopic Exam Color _Texitrre INomoeenrousA FihroMR_Asbestosfff. of SameM PI M Finmimrim Components I%+/- Morphology /Pkroehroism I R 1lndex IP�id lar Biref I Extinction Sip Elongation ICalcits / Talc I Binders I 1 Non -Fibrous Prcpltreatmrnt : mechanical separation Asbestos Content : Nolte Detected Comments: _IVED C r ` n a 91n �0 F� Analyst: Erik Barnes !� Date Analyzed: 12/17/2005 Steve Moody Micro Services, Inc. Bulk Asbestos Analysts Sheet • TDH License No. 30-OM • EPA Method 600 / R-93 / 116 • N V LAP Lab No. 102( Client: Austin Environmental, Inc. Project : Joe Bartuglia, Main 101 Grill and Bar Project # : AESD-05-16 Lab Job# : x5B-102113 Sample # : MG3A Client Sample Description: 12" x 12" Floor Tile (Off-white), Dining Room Page 1 of 1 Layer 1 Floor Tile PI M Fewm:nntim, Color Parallel Perpeldicular Extinction Sign of C n % +I- Morphology / Pl ocluoism Ref Itdat Rcf. Index Biref Angle Elon ion aletta / Vhryl Blnden 1 _ Non�ibrous hi0h —' — Prep/treatment : heat / melt Asbestos Content : None Detected ------------------------------------------------ Layer 2 Yellow Mastic Stereoscopic Exam PLM E=ni=ion C mponents % 1 +l- M b Nonbrorra Color / Pleochroian Parallel Ref. Index Perpendicular Ref Index Biref Extinction Sign of Angle IElong;nion lup Blndars _ Pt :Wftca menl : heat / melt Asbestos Canent : None Detected ------------------------------------------------ F?ECEIVEO FEB n Comments: I Analyst: Erik Barnes Date Analyzed: 12/17/2005 7N Micro Services. Inc. TDH License No. 30-0094 EPA Method 600 / R-93 / 116 NVLAP lab No. 1020 . - . Client: Austin Environmental, Inc. Project : Joe Bartuglla, Main 101 Grill and Bar Project # : AESD-05-16 Lab Job# : x5B-10283 Sample N : MG-3B Client Sample Description: 12" x 12" Floor Tile (Off-white), Restroom Page 1 of 1 Layer I Floor Tile PLM Examimtion Exam _ Componotts % +/- MapholoRy Color / Pleachroism Parallel Ref. index PerpendicuLv Ref. Ittdex Biref Fntinction Anale Sign of Elonxation �alcl s / VInyl Binders 1 NoMlimous��� PrcyOeatment : heat / melt Asbestos Content: None Detected ------------------------------------------------- Layer 2 Yellow Mastic Stereoscopic Exam PLM Fxamirddim tobv Color /Pleochroisrt IICI Ref. Ind" PRef. Index Bhef Extinction IEsortgation lua Blrtdbra 104 1 Non4lbrous Pmpkrcw mt : heat I melt Asbestos Content: None Detected ------------------------------------------------ ..-EIVED rF° v 3 2�Co Comments: Analyst: Erik Barrias Date Analyzed: 12/17/2005 Z4) Steve Moody Micro Services, Inc. Bulk Asbestos Analysis Sheet - Toll Lkm= No. 30-0094 I EPA Method 600I R-93 / 116 ' NV LAP Lab No. 1020 Client: Austin Environmental, Inc- ' Project : Joe Bertuglia, Main 101 Grill and Bar Project # : AESD-05.16 Lab Job# : XSB-10283 Sample # : MG-3C Client Sample Description: 12" x 12" Floor Tile (Oft -white), Kitchen Page 1 of 1 Layer 1 Floor Tile PI M Fxaminatixm Exam Components % +/- M logy Co or I Pbochmiun Parallel Ref. Index Perpendicular Ref. Index Biref - Extinction Angle Sign of Elora Ion r—alcft / Vinyl Binders 1 Nonllbrous high Prcp✓awtment : heat / melt Asbestos Content: None Detected ------------------------------------------------- layer 2 Yellow Mastic Stereoscopic Exam DI M Frnminaf inn u ICJIIe % -F�Ref. Color /Pkochsoistn Parallel Index Perpendicular Ref.lydea Bhef Extraction Angle____IEbngmion Sign of BIsMma Prephreatmcnt : heat / melt Asbestos Content: None Detected ------------------------------------------------- J1p F RECEIVED FEB ^ 2006 Comments: Analyst: Erik Barnes `n Date Analyzed : 12/17/2005 �{J (Please print legibly) Page _i— of Your Name : Company Nei Client/Project Date Sampled: Turnaround Requested: _ Rush Normal Sampled by: S, l7ENl //VGEt Contact Information: fo Name: Ye M —E-mail: (address) r /%MLIAK Eft Ci MY=e m Positive stop: _ Yes -i- No -A- Hard copy: (address) *** Please note a handling fee may be applied to submittals with uncontained or improperly pa-,kaged samples. smms Lab Job # Bulk PLM--q-- Lab Use Lab Job # Air PCM only Lab Job # TEM Telephone (phone no.) _f`an- ner} .5,P6NLrNCrG2 P AW61V4/ RK CaA4 Sample No. Sample Description Air Volume Field Notes ' Srod Gtl It t. It ,e / t /Y 1l /t - ol 1 r a - -a )t iL it V'20, it L It , 1 ! / �` O / Nc 3B tt 1, It it tt ft ES 3G tt 1, It ,, t /�/, re Rel DaWrime: 1 2-15-4!� 5,15 r Received Bye Dawrime: Released by: Dawrime: Received By: as 7 �r�vv.r Date rime: Notes: (:AST Ail✓ LANPR74XLtS iykk B.45 /4% c MA A] Initials: LSED Date: �_U_ S/eve rlloodi' k1icro Services, Inc. - 1510 Randolph, Suite 601- Carrollton, Texas 75006 - (971)446-9 81-FAX (972 446-9870 - NVLAP Lab# 102056 - TOHLiame# 30-0084 [Asbestos COC ver. 1.1] :RU'T[N EIk1IPON1d1fRL SFFmDOL4< FRK NO. :2614411. ; -Xec. 19 2005 10:25PM P2 No. J FAO • ENGINEERING UAL uuTIONS °i1e A2 Ptdlminan _/_ ..lD50 Final flap S1r CAk. ..__.... ... .... .'-._.. _.. ......_. _.._ v... �4- � y IA RE��11[€8.;... FEB O� r��- * * * Control No 9 1' TEXAS` * # 8331*6 Depa&nent of ,;tat,, Health Services artment of State ices certifies that: WDIMPLE DEL R Planner License Number: From: To: ul a A 205548 12/14/1004 12/13/2005 i I RECEIVE RECE 'TEXAS * Control No: �c ,t 83GY WIN Slaty I i!•ahb Scrvi, vs Department of State Health Services certifies that: PAUL B DEHLINGER is Licensed as an: l:+Ii+iiLl;ii :�ri2c��iv.', ltu�uilant License Number: 105523 From: 02/02/2005 To: 02/01/2607 I rn n n rn LJ . r� �I DEPARTMENT OF STATE HEALTH SERVICES BE IT KNOWN THAT AUSTIN ENVIRONMENTAL INC. is licensed and authorized to perform as an Asbestos Consultant Agency in the State of Texas within the purview o l % e, chapter 1954, so long as this license is not suspended or revoked and is renewed�aaglg p r�u e9Prscggy the Texas Board of Health. 100313 Liccuw Number 6/2005 n Issue Date o F9 0 6/ ' 007 Co Eiiijiration Date oTWcertificate is void after m * 'Ir 7. Todd F. Wino, P.E. y' Chief, Asbestos Programs Branch I� Toxic Substances Control Division Eduardo 1. Sanchez, M.D., M.P.H. Commissioner of Health <<IRINNING <<i�JAY SERVICES PLAN REVIEWS - INSPECTIONS ACCESSIBILITY - BUILDING CODE - ENERGY - FIRE MARCH 16, 2006 CITY OF LA PORTE 604 W FAIRMONT PARKWAY LA PORTE, TEXAS 77571 ATTN: MS. DEBBIE WILMORE - CBO CHIEF BUILDING OFFICIAL PROJECT: MAIN 101 GRILL & BAR 101 E MAIN LA PORTE, TEXAS REFERENCE: l INTERNATIONAL ENERGY CODE PLAN REVIEW �� DEAR MS WILMORE, P.O. Box 750953 Houston, Texas 77275 OFFICE 281.922-0700 PAGER 281.278.1833 TOLL FREE 1.866.922.7260 E-MAIL bill0wfnninaway.net 2006-0315057 THIS IS TO CONFIRM THAT A PLAN REVIEW FOR THE REFERENCED FACILITY HAS OCURRED. THE REVIEW OF THE PLANS AND APPROVAL OF PLANS IS INDICATED BY THE ATTACHED COM-CHECK COMPLIANCE REPORT. THE PLANS USED THE 3.2 VERSION OF COM-CHECK USING THE ASHRAE STANDARDS FOR ALTERATIONS FOR AN EXISTING BUILDING. THE REVIEW REQUIRED BOTH A LIGHTING REPORT FOR THE DINING AND AN ENVELOPE WITH LIGHTING AND HVAC FOR THE KITCHEN AREA THE SITE INSPECTION OF THE FACILITY WILL CHECK TO CONFIRM THAT ALL SPECIFICATIONS LISTED ON THE PLANS - SPECIFICATIONS ARE INCORPORATED INTO THE CONSTRUCTION AND COMPLETED BUILDING. A SITE INSPECTION AT THE COVER AND FINAL INSPECTIONS, BY THIS COMMERCIAL ENERGY INSPECTOR, WILL ASSURE THAT COMPLIANCE IS AS REQUIRED. IF THERE ARE ANY QUESTIONS, PLEASE FEEL FREE TO CALL BILL WINNING AT WINNING WAY SERVICES, INC. WITH THE OFFICE NUMBER OF 281-922-0700. RESPECTFULLY SUBMITTED, WILLIAM T. WINNING III - C.ClEAMINER WINNING WAY SERVICES, I ICC COMMERCIAL ENERGY ICC COMMERCIAL ENERGY INSPECTOR CC: JOE BERTGULIA RFC' MAIN 101 GRILL & BAR 414 KAREN HAMILTON 6 KAREN HAMILTON - CUSTOM RESIDENTIAL DESIGN 1��6 Permit p Permit Date COMcheck Software Version 3.2.0 Lighting and Power Compliance Certificate Standard 00.1-2001 Report Date: 03/16/06 Data filename: C:Oowments and Settings%WILLIAM WINNINGW1y DocumentslMAIN 101 GRILL & BAR - DINING - LIGHTING.wk Section 1: Project Information _ A Project Title: MAIN 101 GRILL & BAR Construction Site: Owner/Agent: signer/Contractor: 101 E MAIN JOE BERTGULIA KAREN HAMILTON LA PORTE, TX 77571 MAIN 101 GRILL & BAR KAREN HAMILTON - CUSTOM 2005 YORKTOWN RESIDENTIAL DESIGN SEABROOK, TX 77586 PO BOX 725 713-294-8668 SEABROOK , TX 77586 281-326-0074 Section 2: General Information Building Use Description by: Activity Type Project Type: Alteration Activity Area Compliance Exemption Qualifications Total Wattage Total Pro -Alt. 0 Fixtures Activity Area Pro -Alt. Post -Alt. Fixtures ReplJAdded Common Space Types:Dining Area_(2482 sq.ft.): — — — — Compliance required. Common Spars Types:Restrooms (270 sq.ft.): — — — Compliance required. �c^ Section 3: Requirements Checklist C Interior Lighting: 0 1. Total actual watts must be less than or equal to total allowed watts. �QO6 Allowed Watts Actual Watts Complies 3745 3664 Passes Exterior Lighting: ❑ 2. Minimum efficacy of 60 lumen/watt for lamps greater than 100W. ❑ 3. Lighting power for canopies, entrances, and exits meets the following criteria (tradeoffs allowed among these applications): (i) Lighting power for free-standing canopy areas or building entrances with canopies Is less than or equal to 3 watts per square foot. (il) Lighting power for building entrances without a canopy is less than or equal to 33 watts per linear foot of door width. (iII) Lighting power for building exits Is less than or equal to 20 watts per linear foot of exit door width. 0 4. Lighting power for building facades is less than or equal to 0.25 watts per square foot of the Illuminated area. Exceptions: Controlled by motion sensor, signal or advertising signage, highlighting features of historic monuments and buildings, or Page 1 of 3 required for safety or se, Controls, Switching, and Wiring: ❑ 5. Independent manual or occupancy sensing controls for each space (remote switch with indicator allowed for safety or security). ❑ 8. Automatic shutoff control for lighting in >5000 sq.8 buildings by time -of -day device, occupant sensor, or other automatic control. Exceptions: 24 hour operation lighting. ❑ 7. Master switch at entry to hotel/motel guest room. ❑ 8. Separate control device for displayieccent lighting, case lighting, task lighting, nonvisual lighting, lighting for sale, and demonstration lighting. ❑ 9. PhotocelVastronomlcal time switch on exterior lights. Exceptions: Covered vehicle entrancelexit areas requiring lighting for safety, security and eye adaptation. ❑ 10. Tandem wired one -lamp and three4amp ballasted luminaires (No single -lamp ballasts). Exceptions: Electronic high -frequency ballasts; Luminaires not on same switch; Recessed luminaires 10 ft. apart or surface/pendant not continuous; Luminaires on emergency circuits. Voltage Drop: ❑ 11. Feeder conductors have been designed for a maximum voltage drop of 2 percent. ❑ 12. Branch circuit conductors have been designed for a maximum voltage drop of 3 percent. ❑ 13 Voltage drop analysis must include the pans of the existing system extending to the point of electrical supply at the transformer or service equipment entrance. Section 4: Compliance Statement Compliance Statement: The proposed lighting alteration project represented in this document is consistent with the building plans, specifications and other calculations submitted with this peril application. The proposed lighting alteration project has been designed to meet the Standard 90.1-2001. Chapter 8, requirements in COMcheck Version 3.2.0 and to comply with the mandatory requirements in the Requirements Checklist. Principal Lighting Designer -Name Signature Section 5: Post Construction Compliance Statement Record Drawings and Operating and Maintenance Manuals Date Construction documents with record drawings and operating and maintenance manuals provided to the owner. Project Notes: INFORMATION SUPPLIED BY OWNER - SUPPLEMENTED DRAWINGS Page 2 of 3 Permit # Permit Date COMcheck Software Version 3.2.0 Lighting Application Worksheet Standard 90.1-2001 Report Date: Data filename: C:\Documents and Settings\WILLIAM WINNING\My Documents\MAIN 101 GRILL 8 BAR - DINING - LIGHTING.cck Section 1: Allowed Lighting Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (1`12) Watts / f112 (B x C) Common Space Types:Dining Area 2482 1.4 3475 Common Space Types:Restrooms 270 1.0 270 Total Allowed Watts = 3745 Section 2: Actual Lighting Power Calculation A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp I Ballast Lampa/ # of Fixture (C X D) _ Fixture Fixtures Waft ;Common Space Types:Dining Area (2482 sq.R.) --� Incandescent 1: LITE FIXTURE / Incandescent BOW 1 9 60 540 Incandescent 2: RECESSED LITE / Incandescent 45W 1 36 45 1620 Incandescent 3: EYEBALL SPOT / Incandescent 4OW 1 9 40 360 Incandescent 4: FAN WITH 4 BULB / Incandescent 25W 4 7 100 700 ,Common Space Types:Restrooms (270 sq_ft.). , Incandescent 1: LITE FIXTURE / Incandescent 60W 1 1 60 60 Linear Fluorescent 1: 2X4 3TS-32 / 48' T8 32W / Electronic 3 4 96 384 Total Actual Watts = 3664 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero, the building complies. Total Allowed Watts = 3745 Total Actual Watts = 3664 Project Compliance = 81 Lighting PASSES Page 3 of 3 Permit # Permit Date COMcheck Software Version 12.0 Envelope Compliance Certificate Standard 90.1-2001 Report Date: 03/16/06 Data filename: C:\Documents and Settings\WILLIAM WINNING\My Document5NMAIN 101 BAR & GRILL - KITCHEN.cck Section 1: Project Information Project Title: MAIN 101 GRILL & BAR Construction Site: 101 E MAIN LA PORTE. TX 77571 Owner/Agent: JOE BERTUGLIA MAIN 101 BAR & GRILL 2005 YORKTOWN SEABROOK, TX 77586 713.294-8668 Section 2: General Information Building Location (for weather data): La Porte, Texas Heating Degree Days (base 65 degrees F): 1550 Cooling Degree Days (base 50 degrees F): 7026 Building Type for Envelope Requirements: Non -Residential Project Type: Alteration Activity Tvoefsl Floor Area Hospitality and Food Service:Bar Lounge/Leisure Dining Area 907 Section 3: Requirements Checklist Climate -Specific Requirements: a3't4lrrap6 Desig ntractor: KAREN HAMILTON KAREN HAMILTON - CUSTOM RESIDENTIAL DESIGN PO BOX 725 SEABROOK, TX 77586 281-326-0074 R-Value Proposed Max. Allowed Post -Alteration Assembly Cavity Cont. U-Factor SHGC U-Factor SHGC Roof 1: Insulation Entirely Above Deck — 19.0 0.051 — 0.063 — Exterior Wall 1: Metal Building Wall 13.0 4.5 0.075 — 0.113 — Door 1: Unirisulated Single -Layer Metal, Non -Swinging — — 0.350 — 1.450 — Floor 1: Slab-On-Grade:Unheated — — — — — — Exemption: No cavity will be created Insulation: i ❑ 1. Open -blown or poured loose -fill Insulation has not been used in attic roof spaces with ceiling slope greater thary9yin 12( � ❑ 2. Wherever vents occur, they are baffled to deflect Incoming air above the Insulation. '9� Ci ❑ 3. Recessed lights, equipment and ducts are not affecting insulation thickness. ✓ L ❑ 4. No roof Insulation Is installed on a suspended ceiling with removable ceiling panels. ❑ 5. All exterior Insulation is covered with protective material. Q ❑ 6. Cargo and loading dock doors are equipped with weather seals. -17 MAIN 101 GRILL & BAR Page 1 of 9 Fenestration and Doors! -1 ❑ 7. Windows and skylights are labeled and certified by the manufacturer for U-factor and SHGC. ❑ S. Fixed windows and skylights unlabeled by the manufacturer have been site labeled using the default U-factor and SHGC. ❑ 9. Other unlabeled vertical fenestration, operable and fixed, that are unlabeled by the manufacturer have been site labeled using the default U-factor and SHGC. No credit has been given for metal frames with thermal breaks, low -emissivity coatings, gas fillings, or insulating spacers. Air Leakage and Component Certification: ❑ 10. All joints and penetrations are caulked, gasketed, weather-stripped, or otherwise sealed. ❑ 11. Windows, doors, and skylights certified as meeting leakage requirements. ❑ 12. Component R-values & U-factors labeled as certified. ❑ 13. Insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value without compressing the insulation. Section 4: Compliance Statement Compliance Statement: The proposed envelope alteration project represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed envelope alteration project has been designed to meet the Standard 90.1-2001 requirements in COMcheck Version 3.2.0 and to comply with the mandatory requirements in the Requirements Checklist. Principal Envelope Designer -Name Signature Date Project Notes: ADDITIONAL INFORMATION - AS ADVISED BY THE OWNER - CONTRACTOR - SUPLEMENTED THE DRAWINGS SUPPLIED. MAIN 101 GRILL & BAR Page 2 of 9 Permit # Permit Date COMcheck Software Version 3.2.0 Lighting and Power Compliance Certificate Standard 90.1-2001 Report Date: 03/16/06 Data filename: C:\Documents and Settings\WILLIAM WINNING\My Documents\MAIN 101 BAR & GRILL - KITCHEN.cck Section 1: Project Information Project Title: MAIN 101 GRILL & BAR Construction Site: Owner/Agent: 101 E MAIN JOE BERTUGLIA LA PORTE, TX 77571 MAIN 101 BAR & GRILL 2005 YORKTOWN ' SEABROOK, TX 77586 713-294-8668 Section 2: General Information Building Use Description by: Activity Type Project Type: Alteration Activity Area Compliance Exemption Qualifications Designer/Contractor: KAREN HAMILTON KAREN HAMILTON- CUSTOM RESIDENTIAL DESIGN PO BOX 725 SEABROOK. TX 77586 281-326-0074 Total Wattage Total Pre -Alt. # Fixtures Activity Area Pre -Alt. Post -Alt. Fixtures Repl./Added Hospitality and Food Service:Bar Loungell-eisure Dining Area (907 — — — — sq.R.): Compliance required. Section 3: Requirements Checklist Interior Lighting: ❑ 1. Total actual watts must be less than or equal to total allowed watts. Allowed Watts Actual Watts Complies 1088 1084 Passes Exterior Lighting: 4' 1 `<// I6 O <P0,96 ❑ 2. Minimum efficacy of 60 lumen/watt for lamps greater then 100W. .03. Lighting power for canopies, entrances, and exits meets the following criteria (tradeoffs allowed among these applications): (I) Lighting power for free-standing canopy areas or building entrances with canopies is less than or equal to 3 watts per square fool (it) Lighting power for building entrances without a canopy is less than or equal to 33 watts per linear foot of door width. (Ili) Lighting power for building exits Is less than or equal to 20 watts per linear foot of exit door width. ❑ 4. Lighting power for building facades is less than or equal to 0.25 watts per square foot of the illuminated area. Exceptions: Controlled by motion sensor, signal or advertising signage, highlighting features of historic monuments and buildings, or required for safety or security. MAIN 101 GRILL & BAR Page 3 of 9 I Controls, Switching, an6 e:iring: Cl 5. Independent manual or occupancy sensing controls for each space (remote switch with Indicator allowed for safety or security). ❑ 8. Automatic shutoff control for lighting In >5000 sq.ft buildings by fimeof-day device, occupant sensor, or other automatic control. Exceptions: 24 hour operation lighting. ❑ 7. Master switch at entry to hotellmotel guest room. ❑ 8. Separate control device for display/accent lighting, case lighting, task lighting, nonvisual lighting, lighting for sale, and demonstration lighting. ❑ 9. Photocell/astronomical time switch on exterior lights. Exceptions: Covered vehicle entrance/exit areas requiring lighting for safety, security and eye adaptation. ❑ 10. Tandem wired one -lamp and three -lamp ballasted luminaires (No single4amp ballasts). Exceptions: Electronic high -frequency ballasts; Luminaires not on same switch; Recessed luminaires 10 ft. apart or surface/pendant not continuous; Luminaires on emergency circuits. _ Voltage Drop: ❑ 11. Feeder conductors have been designed for a maximum voltage drop of 2 percent. ❑ 12. Branch circuit conductors have been designed for a maximum voltage drop of 3 percent. ❑ 13 Voltage drop analysis must include the parts of the existing system extending to the point of electrical supply at the transformer or service equipment entrance. Section 4: Compliance Statement Compliance Statement: The proposed lighting alteration project represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting alteration project has been designed to meet the Standard 90.1-2001, Chapter 8, requirements in COMchack Version 3.2.0 and to comply with the mandatory requirements in the Requirements Checklist. Principal Lighting Designer -Name Signature Date Section 5: Post Construction Compliance Statement Record Drawings and Operating and Maintenance Manuals Construction documents with record drawings and operating and maintenance manuals provided to the owner. J6' �O MAIN 101 GRILL 8 BAR Page 4 of 9 Permit If Permit Date COMcheck Software Version 3.2.0 Lighting Application Worksheet Standard 90.1-2001 Report Date: Data filename: C:WDocuments and SetdngsWWILLIAM WINNINGWMy DocumenfsWMAIN 101 BAR 8 GRILL - KITCHEN.cck Section 1: Allowed Lighting Power Calculation A Area Category B C D Floor Area Allowed Allowed Watts (M) Watts I M (B x C) Total Section 2: Actual Lighting Power Calculation 1088 A B C D E Fixture ID : Description I Lamp / Wattage Per Lamp I Ballast Lamps/ 0 of Fixture (C X D) Fixture Fixtures Watt. .Hospitpllty and Food-Service:Bar Lounge/Lelsure Dlning Area (917 aq.R)_ Linear Fluorescent 1: 48' TB 32W / Electronic 3 9 96 864 Incandescent 1: Incandescent 100W 1 1 100 100 Incandescent 2: Incandescent 60W 1 2 60 120 - Total Actual Watts = 1084 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Actual Watts Is greater than or equal to zem, the !wilding complies. Total Allowed Watts = 1088 Total Actual Watts = 1084 Project Compliance = 4 Lighting PASSES �9916'C/Gf <006' MAIN 101 GRILL 8 BAR Page 5 of 9 tJ Pennit # Permit Date COMcheck Software Version 3.2.0 Mechanical Compliance Certificate Standard 90.1-2001 Report Date: 03/16/06 Data filename: C:\Documents and Settings\WILLIAM WINNING\My Documents\MAIN 101 BAR & GRILL - KITCHEN.cck Section 1: Project Information Project Tifle: MAIN 101 GRILL & BAR Construction Site: Owner/Agent: Designer/Contractor: 101 E MAIN JOE BERTUGLIA KAREN HAMILTON LA PORTE, TX 77571 MAIN 101 BAR & GRILL KAREN HAMILTON - CUSTOM 2005 YORKTOWN RESIDENTIAL DESIGN SEABROOK, TX 77586 PO BOX 725 713-294.8668 SEABROOK, TX 77586 281-326-0074 Section 2: General Information Building Location (for weather data): Le Porte, Texas Heating Degree Days (base 65 degrees F): Ism Cooling Degree Days (base 50 degrees F): 7026 Project Type: Alteration Section 3: Mechanical Systems List Quantity System Type & Description 1 HVAC System 1: Cooling: Split System, Capacity <65 kBhA, Air -Cooled Condenser / Single Zone Compliance required. Section 4: Requirements Checklist Requirements Specific To: HVAC System 1 : ❑ 1. Equipment minimum efficiency: Split System: 10.0 SEER Generic Requirements: Must be met by all systems to which the requirement Is applicable: ❑ 1. Load calculations per 2001 ASHRAE Fundamentals ❑ 2. Thermostatic controls has 5 degrees F deadband • Exception: Thermostats requiring manual changeover between heating and cooling ❑ 3. Hot water pipe Insulation: 1 In. for pipes <=1.5 in. and 2 In. for pipes >1.5 in. Chilled water/refrigerant/brine pipe Insulation: 1 In. for pipes <=1.5 in. and 1.5 In. for pipes >1.5 in. Steam pipe Insulation: 1.5 In. for pipes <=1.5 In. and 3 in. for pipes >1.5 In. - Exception: Piping within HVAC equipment - Exception: Fluid temperatures between 55 and 105 degrees F - Exception: Fluid not heated or cooled - Exception: Runouts W 8 in length ❑ 4. Where separate thermostats are used for heating and cooling, acceptable measures are used to prevent simultaneous C� heating and cooling ❑ S. Stair and elevator shaft vents are equipped with motorized dampers f6' ❑ 6. Acceptable measures used to prevent simultaneous humidification and dehumidification - Exception: Desiccant systems and systems for uses requiring specific humidity levels (approval required) 0�6' MAIN 101 GRILL & BAR Page 6 of 9 ❑ 7. Automatic controls for free 'dection systems present ❑ 8. Automatic ventilation controls (e.g., CO2 controls) or exhaust air heat recovery present for high design occupancy areas (>100 person/1000 fit) with >3,000 cfm outside air capacities ❑ 9. Duct, plenum, and piping insulation surfaces suitably protected from weather, moisture, or likely damage ❑ 10. R-6 supply and return air duds in unconditioned spaces R-8 supply and return air ducts outside the building R-8 insulation between duds and the building exterior when ducts are part of a building assembly R-3.5 supply and return air ducts insulation underground ❑ 11. Dud Seating: Pressure sensitive tape Is not used as the primary sealant Longitudinal and transverse seams for duds in unconditioned spaces Longitudinal and transverse seams and dud wall penetrations for duds outside the building Transverse seams on burled duds ❑ 12. Humidlstat controls prevent reheating, recooling, and mixing of mechanically heated air with mechanically cooled air ❑ 13. Exhaust air heat recovery included for systems 5,000'cfm or greater with more than 70% outside air fraction or specifically exempted ❑ 14. Kitchen hoods >5,000 chn provided with 50% makeup air that is uncooled and heated to no more than 60 degrees F unless specifically exempted ❑ 15. Buildings with fume hood systems must have variable air volume hood design, exhaust heat recovery, or separate makeup air supply meeting the following: a) 75% make up air quantity, and /or b) within 2 degrees F of room temperature and/or c) no humidification d) no simultaneous heating and cooling Section 5: Compliance Statement Compliance Statement: The proposed mechanical alteration project represented In this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed mechanical alteration project has been designed to meet the Standard 90.1-2001, Chapter 8, requirements In COMchack Version 3.2.0 and to comply with the mandatory requirements in the Requirements Checklist. Principal Mechanical Designer -Name Signature Section 6: Post Construction Compliance Statement Date ❑ HVAC record drawings of the actual installation and performance data for each equipment provided to the owner within 90 days after system acceptance. ❑ HVAC O&M documents for all mechanical equipment and system provided to the owner within 90 days after system acceptance. ❑ Written HVAC balancing report provided to the owner. The above post construction requirements have been completed. Principal Mechanical Designer -Name MAIN 101 GRILL 8 BAR Signature Date J 6' <�006, . Page 7 of 9 COMcheck Software Version 3.2.0 Mechanical Requirements Description Standard 90.1-2001 Report Date: Data filename: C.\Documents and Settings\WILLIAM WINNING\My Documents\MAIN 101 BAR & GRILL - KITCHEN.cck The following list provides more detailed descriptions of the requirements in Section 4 of the Mechanical Compliance Certificate. Requirements Specific To: HVAC System 1 : 1. The specified heating and/or cooling equipment is covered by ASHRAE 90.1-2001 Standard and must meet the following minimum efficiency: Split System: 10.0 SEER Generic Requirements: Must be met by all systems to which the requirement is applicable: 1. Design heating and cooling loads for the building must be determined using procedures in the ASHRAE Handbook of Fundamentals or an approved equivalent calculation procedure. 2. Thermostats controlling both heating and cooling must be capable of maintaining a 5 degrees F deadband (a range of temperature where no heating or cooling is provided). - Exception: Deadband capability is not required if the thermostat does not have automatic changeover capability between heating and cooling. 3. All pipes serving space -conditioning systems must be insulated as follows: Hot water piping for heating systems: 1 in. for pipes <=1 1/2-in. nominal diameter 2 in. for pipes >1 1/2-in. nominal diameter. Chilled water, refrigerant, and brine piping systems: 1 in. insulation for pipes <=1 1/2-in. nominal diameter 1 1/2 in. insulation for pipes >1 1/2-in. nominal diameter. Steam piping: 1 1/2 in. insulation for pipes <=1 1/2-in. nominal diameter 3 in. insulation for pipes >1 1/2-in. nominal diameter. - Exception: Pipe insulation is not required for factory -installed piping within HVAC equipment. - Exception: Pipe insulation is not required for piping that conveys fluids having a design operating temperature range between 55 degrees F and 105 degrees F. - Exception: Pipe insulation is not required for piping that conveys fluids that have not been heated or cooled through the use of fossil fuels or electric power. - Exception: Pipe insulation is not required for runout piping not exceeding 4 ft in length and 1 in. in diameter between the control valve and HVAC coil. 4. Where zone heating and cooling are controlled by separate zone thermostats, means (such as limit switches, mechanical stops, or, for DDC systems, software programming) must be provided to prevent simultaneous heating and cooling to the zone. 5. Stair and elevator shaft vents must be equipped with motorized dampers capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. All gravity outdoor air supply and exhaust hoods, vents, and ventilators must be equipped with motorized dampers that will automatically shut when the spaces served are not in use. Exceptions: - Gravity (non -motorized) dampers are acceptable in buildings less than three stories in height above grade. - Ventilation systems serving unconditioned spaces. 6. Where a zone is served by a system(s) with both humidification and dehumidification capability, means (such as limit switches, mechanical stops, or software programming) must be provided to prevent simultaneous operation of humidification and dehumidification equipment. - Exception: Zones served by desiccant systems, used with direct evaporative cooling in series; Systems serving zones where specific humidity levels are required. 7. All freeze protection systems, including self-regulating heat tracing, must include automatic controls capable of shutting off the systems when outside air temperatures are above 40 degrees F or when the conditions of the protected fluid will prevent freezing. Snow- and ice -melting systems must include automatic controls capable of shutting off the systems when the pavement temperature is above 50 degrees F and no precipitation is falling, and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40 degrees F. 8. Systems with design outside air capacities >3,000 cfm serving areas having an average design occupancy density exceed! n0, 100 people per 1000 ft2 must include means to automatically reduce outside air intake below design rates when spaces are, �O partially occupied. Ventilation controls must be in compliance with ASHRAE Standard 62 and local standards. 9. Duct and pipe insulation exposed to weather must be suitable for outdoor service; e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water' is MAIN 101 GRILL & BAR Page 8 of 9 retardant and provides shiek - :xn solar radiation that Can cause degradation of the 'tal.lnsulation covering chilled water piping, refrigerant auction piping, or cooling ducts located outside the conditioned space must include a vapor retardant located outside the insulation (unless the insulation is inherently vapor retardant), all penetrations and joints of which must be sealed. 10. R-6 supplyandreturn air ducts in unconditioned spaces R-8 supply and return air ducts outside the building R-8 insulation between ducts and the building exterior when ducts are part of a building assembly R-3.5 supply and return air ducts Insulation underground 11. Duct Sealing Requirements: - Pressure sensitive tape prohibited as the primary sealant - Longitudinal and transverse seams for ducts in unconditioned spaces - Longitudinal and transverse seams and duct wall penetrations for ducts outside the building - Transverse seams on buried ducts 12. Where humidistatic controls are provided, such controls must prevent reheating, mixing of hot and cold air streams, or other means of simultaneous heating and cooling of the same air stream. Exceptions: - capability to first reduce flow rate - coding capacity <80 kStWh and capability to unload cooling equipment - cooling capacity <40 kBtuth - rigid humidity requirements - site -recovered or site -solar energy sources or - use of a desiccant systems. 13. Individual fan systems with a design supply air capacity of 5000 cfm or greater and minimum outside air supply of 70% or greater of the supply air capacity must have an energy recovery system with at least a 50% effectiveness. Exceptions: - Systems serving spaces that are not cooled and heated to <60 degrees F. - Commercial kitchen hoods (grease) classified as Type 1 by NFPA 96 - Systems exhausting toxic; flammable, paint, or corrosive fumes or dust If an air economizer is also required, heat recovery must be bypassed or controlled to permit air economizer operation. 14. Individual kitchen exhausthoods larger than 5000 cfm must be provided with make-up air sized for at least 50% of exhaust air volume that Is uncooled and either unheated or heated to no more than 60 degrees F Exceptions: - Where foods are used to exhaust ventilation air that would otherwise exfiltrate or be exhausted by other fan systems. - Certified grease extractor hoods that require a face velocity no >60 fpm. 15. Buildings with fume hood systems having a total exhaust rate >15,000 cfm must either have variable air volume hood design, exhaust air heat recovery, or separate make up air supply meeting the following makeup air requirements: - at least 75% of exhaust flow rate - heated to no more than 2 degrees F below room setpoint temperature - cooled to no lower than 2 degrees F above room setpoint temperature - no humidification added - no simultaneous heating and cooling 11006' E`O 6' MAIN 101 GRILL 8 BAR Page 9 of 9 City Of La Porte Fire Marshal's Office Plan Review C 10TY Main 101 Grill & Bar IF THE APPROVED PLANS C ® py 101 E. Main ARE MODIFIED, A NEW SUBMITTAL TO THE CITY IS REQUIRED PRIOR TO THE CHANGE OCCURRING Date: 9 February 2006 Reviewed by: Clif Meekins, Fire Marshal Approved: Yes No With noted Changes XX The following items are identified by the Fire Marshal's Office during the plan review: 1) Fire Extinguishers shall be installed according to the NFPA requirements and/or every 75 foot of travel. 2) A K-type fire extinguisher shall be mounted in the kitchen. 3) Submit drawings and separate permit for vent hood fire suppression system. The suppression system must have an audible alarm tied into it. 4) Reverse the direction of the Front Entry door and the exit door from the Covered Patio labeled as (#3) by the Fire Marshal's Office to open in the direction of egress as indicated on drawing (2). 5) Install emergency lights as indicated on drawing (2). 6) Install EXIT sign with emergency light as indicated on drawing (2). 7) Install EXIT sign as indicated on drawing (2). 8) Occupant load for dinning room and bar area is 100 604 West Fairmont Parkway La Porte, TX 77571 Office: 281-8674603 Fax:281-470-5005 m cc -.ice iro m A j Tv ew• a w0 ae O` 2 : 87 p4i dam- D .cam-a_..c�2------ it , - -- I r fl il• nl.• / JJ AC023 -08(-0002 Lis /—Y B�K /Q/ 4CiAv�*C>z3 ZS(o eq O4o Le+S INSPECTION SERVICES MINOR DEVELOPMENT. SITE PLAN CHECKLIST L , Job Address: 10 1 E, Moo,", Sr�• Development Name: M !+ i Q 1 G r A R / \ Type of Business/Development: GornerciA 9ts-6vraat ( IE—:x p Ar6ton) j New 0J CLP Project No.: # 0 Date Rcv'd. in Inspections: 3 - I — fl Legal Description: Lao S 151 K 181 - L T. Zoning: /✓1 S OV cJ93 SIC No.: # 5812 Allowable Use OR N P & Z and/or C.C. Action? Ord./Permit #s: Street/Alley Closing Action? Ord. #s: /V ,,!�- FORMAT Engineer or Surveyor Sealed (Dev. Ord #1444; App. E) Yes Or No Development Name Shown (Dev. Ord #1444,-App. E) Yes or No Development Type Shown (Dev. Ord #1444; App. E) Yes or No Legal Description Shown (Dev. Ord #1444, App. E) Yes or No Job Address Shown (Dev. Ord #1444, App. E) es or No Building Footprint Shown (D.ev. Ord #1444; App. E) or No Scale of Plat Shown (Dev. Ord #1444; App. E) Yes or No North Arrow Shown (Dev. Ord #1444; App. E) Yes Or NO Utility Easement leys — Shown? (Dev. Ord #1444; App. E) (IfApplicab e Flood Zone - "�" - Shown? (Dev. Ord #1444; App. E) Yes or No B.F.E. - - Shown? (If Applicable) Flo6d Plain Development Permit Required? Received? N/A Inspection Division Site Plan Checklist SPECIAL PERMITS Driveway/Culvert Permit Required? (State or County or City) Drainage Permit Required? (State or County or City) (Obtain Copy) (Obtain Copy) UTILITIES Utility Verification Completed? Results: a) Water Available w/o Extension b) Sewer Available w/o Extension c) Utility Extension Agreement Needed? d) Utility Easement Agreement Needed? Water Development Fees - (Ord # 759 F) Water Tap Size Q- S N (Ord # 759E) Irrigation Size - (T ) (Ord #759 E) Sewer Development Fees - (Ord #759-F) Sewer Tap Size — MiS4 it, (Ord # 759F) *includes sewer inspectio ee charge On & Off -Site Utilities Shown: a) Water Line Size/Routing b) Sewer Line Size/Routing c) Gas Line Size/Routing d) Electric Line Routing (O.H. or Undgd.) Page 2 �0 o � �r�y was _ ,_ $cL 9 wee er--l+le .✓//JVea 1 1 , g ex1S+'( + Grease Trap/Sample Well Shown? (Ch 74 of Code of Ord) Yes or See Sample Well Detail Sheet for Installation (Note: Gray water to tie-in downstream of grease trap.) No No No No No Inspections Division Site Plan Checklist Page 3 ZONING (Chapter 106 of the City's Code of Ordinances) $d % Maximum Lot Coverage Confirmed? Y or No Sect. 106-443, Table B (Commercial) and Sect. 106-522, Table nd;t t' al) Required Building Setbacks Adequate? Yes r No Sect. 106-443, Table B (Commercial) and Sect. 106-522, Table B ndustrial) d Front - O Rear 20 Side O S IC, / op� Signage in Compliance? (Location, height, size) (Sect. 106-871 thru 879) Parking Regulations Surface is Dust -Free? (Sect. 106-835[I7) Yes or No Driveway(s) & Approaches in Compliance? Yes or No — Al �24_/ (Sect. 106-835, Fig. 10-3 and [e]) (Location, Number, Size, Etc.)g- Curbing/Curbstops Okay? (Sect. 106-835[il) Yes)or Nopt Size of Spaces & Aisles - Adequate? Yes or No (Sect. 106-835[a][c-4] and[d]) Regular- 10'X18'; Accessible- 14'X20'; Parallel- 10'X22' (� Circulation Aisle - 28' (90-degree parking) 18' (60 & 45-degree) "U a C�_5 Ratio of Spaces Adequate? (T. 1106.1 Of 2003 Ed of MIT Bldg. Code) Regular No S:\CPShare\INSPECnON DMSION\Insp=Uons\Ins Services Site Plan Ckhstdoc Rev. 11-29-04 dsw Memo TO: Rodney Slaton; Engineering Masood Malik; Planning Curtis Herrod; Public Works Champ Dunham; Fire/EMS Mark Huber, Inspections Frw= Traci Koenig; Planning Data March 1, 2006 Re: Main 101 Grill & BaCCLW06--8207 Gentlemen: Planning Department RECEIVED INSPECTIONS 0,3-0 1-6 G Included in this memo is the site plan submittal for the proposed Main 101 Grill & Bar. Please submit your comments via e-mail to me. Thanks _tk 1 Sunflower .a M Page 1 of 1 Jennings, Sherry From: Wise, Sandra Sent: Monday, September 11, 2006 2:17 PM To: Jennings, Sherry; Chavez, Ramona Y Subject: 101 E. Main FM Insp passed on 9/11/06 101 E. Main Thank you, Sandia Wiee Secretary to the Fire Marshal City of La Porte 604 W. Fairmont Pkwy La Porte, TX 77571 281470-5078/Fax 281470-5005 9/12/2006 ANSOM CONCEPTS 4219 WINTERBORNE DRIVE PASADENA, TEXAS 77505 Office: 832-230-5342 Cell: 832-878-1806 ansomconcepis ehhouston.mcom ME-44164 CL-21222 City of La Porte. Electrical Inspection Dept. LaPorte, Texas 77571 Ref: Electrical Permit @ 101 E. Main Street LaPorte, Texas 77571 Gentlemen, Due to non-payment, additions, inconsistencies, and changes in construction plans, it has caused me, TRINIDAD GARZA, dba, ANSOM CONCEPTS to withdraw my Electrical Permit permanently and remove my responsibilities concerning Main 101 Bar and Grill Electrical installation. I, TRINIDAD GARZA have not been on the said property since June 20, 2006. Service conductors, conductors feeding the single phase portion of the distribution, A/C condenser units, three phase ice -machine, compressor units under the bar, walk-in cooler/freezer compressor units, exterior lighting fixtures, ceiling fans, lighting fixtures in bathrooms and kitchen, fixtures in bar area, and fixtures in patio areas had not been installed. If there are any further items to discuss, you can contact me at 832-878-1806 or at the above address. Respectfully, / i i / Existing Landscaping F.I,in, ' �F,i-tirr=l lip li7ii H i ,.,ri, � ' /2 Proposed Landscaping t W yler m 2 m Z W Adam St. W Polk t. \ tree 65 �5 _ �a\� L t '2 C 1 z z z z z 5ti P T ��5\ W A St. d G W B St. y 65 in '2 43 to Y 1-t co � N N to co Cn E _=tits=l P-il, i 0 i / F rfp:-i lh 1I-=ii; O E- -tm�a Fi �dt^i_I �a•ii 0 `-------------------------------------------------------------------- ------ ------ ------------ —---�—Ms—w—M—Ms—�—■»—■»—�—w—w—�—�»—■»—�—w—�—w—w—�—rr—as-.—�Ie—w—■s—�r—w—�—�—�—w—�—w—�—�—�—w—�—�—�_w—w—w—�_�—M—Ms—�—w—w—�—w—�—�—�—�—Ms—N—�� _ Existing Gas Service V Manhole Existing 8" Sewor Line Manhole I Existing SS Tap — — _I_ Existing Overhead Electrical Service — � — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Gz7— — — — —OQ — — — —UF PP�IFound LP_-----1I�04�'oo"E 169.93' ound I.P. Q------------------- Exi tinK d ant / Du�sit I I I o yoe I I I I I o I I / Exist. Conc. I I I 9 I I M S D 10' Setback - --{- - 1 1 1 1 t 1' 1 1 'LI --------- ----- -------I—' -------- -- _} — ---------- -� — — +-------------------�---- -- • ---- ---- -------------- �., Vicinity a ; -Slope Par mg i 1 6 1 1 I I I I I l , , 1,, 1 �; .1. � / Existing SS IC�an-out 26 -� o> 1 / Proposed Gray Water Cleanout �O = Gasl er 0 o Q 0 - - o sg U � v v -_�� o cv �o •°� v O 0 � '� o +, o Z O o Q �p IL`. Q) Lv z c r_ X v ai (1) (1)w F-- LLJ0 q c O F- •� o v Q to 00 d- (1)V) U) D N +� ~ z c (n.00 o O O cn E':-:3 >10 LJL_ H>- � a) �}�- v P E 8 O, Existing Drive 20' Wide ' -0 fTl , Existing 200 amp service / 0 x I entrance �cb -3 I Existing Telephone Service /LO /Ln I I I I I 1 1 ' II Slope I 1 I I 11. , 1, ( 1, 1 ,I, ,I, L.i 8 Slope 12 j fZWat r Meter / I I I 1 Existing I I I I I 1 11 I I Bed I Of I I 1 13 1 1 1 I I 1 1 1. I, I+ I; 1; i Monkey----- i Grass .c� I Slope Entry I I °' G�� I I Area for ADA I 14 pro, / requirements. R10 I I I I I I 1 i o • 4 NI 5 1 o / o +J 1 Ln v O 1 O/--N -I--' c I ICLI I ;n I I II I I I I MI I I I ++ Slope Slope I N Existing Drive ' lix! I I 11 P I I 1 1 I I iI I' 1: I 025' Wide 4� I I I I 1 W `— �-, , I S/0 e _ Slope I X W p Q 1 16 11 I 1 1 I 1 O Name of Development Main 101 Grill and Bar Development Type: Commercial restaurant Zoning MSD (overlay) Legal Address: 101 E. Main, LaPorte, Texas 77571 Owner: Joseph Bertuglia Developer: Joseph Bertuglia Lots 1-4 and 22-26,. Block 181, La Porte, Harris County, Texas (1) I ) I I I I i i Existing Sq. Footage 3321 Sq. Ft. L I, 1 l �; 1, 1 1; �,. 1 Proposed Addtion 518 _ �° I I Slope I Slope I o, I I Total Footprint 3839 S Ft. /I I �-' I 1 I L I L I I 1 19 I 1 , , I I , ,, 11 I� 4 p q — -� — —�--_— — -----a --- — — — — r - -- --- -- — —-----------}-------------------}------J # Existing Parking Spa ----------- -- — -- --- — N ----- -- c----------------------- __-_-- � of Existi P rk' Spaces 20 / I , 1 2 3 1 I I� I 1 �=� ' 1 ' MSD 110' Setback' w ( I I I I I Lot Footage 25,245 Sq. Ft. I Lot 4 1 Lot 3 I Lot 2 I 11 - in Lo I ( Lot 26 I Lot 25 20 I 1. ,Lot 24 1 1 , 1 Lot, 23 I I I. I Lot 22 1 0I 1 ----L 1 —1 1--J----1 ----- 1-- 1 - 1 _"' I I �l�f_ .�----� - --- Landscaped Area 2250 Sq. Ft. -------------------- ---- ---0- Found I. » ' �� � - -- - --- -- ----- -- -- ----- Found I.P. 8.9% Ot N 62 45 00 E 234.01 2s•-�" 18' Instead of traditional grease trap, an upgraded AGI EE t 2� W�meDrive (Automatic Greese Interceptor) System will be installed and utilized with sample well. �1o. 0 CITY APPROVING AUTHORITY CERTIFICATE This is to certify that the City of La Porte, Texas. has approved this site plan and development EMain of MAIN 101 GRILL AND BAR in conformance with the YOrdinances of the Cit of La Porte. Street 100' ROW By -- ---- — ----- 3-�5�-� ------------------- Director, PlannDepartment SITE PLAN ACCURACY CERTIFICATE I, Billy L. Shanks, R.P.L.S. #1821, am registered under the laws f the State of Texas to practice the profession of surveying and hereby ce that the above plat or site plan Is true and correct; and that all bearings, distances, angles, curve radii, and central angles are accurately shown the plat. BILLY Wo 182" Q►, f ,�►�°�►�,f��oO' Billy L./Shanks sJOB NO. 34703 i L !r x r plan number 2,53 . i description Fla „ = 09 date released ed sheet number 11 11 1_.. l.J .._ . _ �_ _. -� —- � __.. _ ._tea. .fie �_•1� �� _.I.e_ .�_ _. _ � ..a ._ ... Typical Foundation and Wall Section at Additions in = it —on 4040 FG and 4014 FG Arch typical to all four sides of tower I Hardi Board Will HIM IS, 11001 ................... Hardi Board Left Side Elevation Rear Elevation Jim = i I —on Thin Stone Veneer Rio! � � Side Elevation Front Elevation �77 A 7- 71;1'.7 17 Lr) X C) 0) Q) 0 C C N �- 0 x 0 0 N 0 CO 0 CZ 0.0 CO CU 00 0 0 LC N E 0 -mle ==Mond plan number 2836 description Exterior Elevations date released revised sheet number 11 0 11 0 0 a 0 Field Verify All Dimensions Prior to Demolition/Construction. All new construction shall be indicated by shaded walls. 21'-Ow 4*-0" Proposed Slab under Cooler Cooler rzr 6 Proposed Sample Well 1,14 r- 109-3m Hand Floor Sink Sink 0 f I C, e, Drain 0 I L0 3600 0 Oven Convectio i M DbI 4) 0 c 0 X 0 60X30 :3z Chargrill in ml ZP 0 0 00 it MI — — — — — — — — — — — — — — — — - X 'D @L E @ 'D0ian a E -2 0 W I.W91 -ovide 9' Billing at tchen. (56) P, S-2j' ce Mqcjh0e---M w/ FI F or I I I c,j Sink Yrildor I I 63x35er Line of Existing BalconyL � Ad Fry Prep Area I Mixer 1 o ■ L- - - - 1 *C4 I ,e 21'-8* T-00 1 79'-4* 7R-Ow 1 V-8- � 2#-60 1 �10 89-00 it 20-6* 1 39-80 'Stone Clad Columns -10, 6050 !HS 6050 �HS -605C Z _10) Covered Dinincj Tile Entry 0_�f' B' Ceiiiing 'rile 2 10' Ceiling 0 25'-2a 0 1 101-00 4--7j- W 0 30-4" 39-40 4'-6 29-100 5'-0" 5'-0"99-00 0 3060 FG 3060! FG 3060 FG 0 (j-0) 1 '42" Wall with 42* Wall with Wood Cap Wood Ca LD 4r- 10,-1j. Iv Ix A(1* Remove exi sting Wads _____/v /00 N Ba r Drain 70-010 These clrawincj5 are not intended to enumerate each and every pie -cc of lumber, ecluipment, material or other necessary component recluired for the proper construction of this facility. Care shall be tAen at the job -site to ensure that construction meets or exceeds all applicable buildincj, codes. Karen Hamilton, Dimcn51Or14''9"i'n' DC51cjn, 15 not and does not claim to be an encj,inq_ehncj, firm. All recluired engineering Shall be done by other's and 15 not 15 thi5 contract. Procurement Of stamped, -certified engineering clrawinCJ5 Will be the re5pon5lbility of the ,General Contractor. 9#-40 80 7P-0w 40-00 4'-8* 40-80 Occupancy: 150 6050 HS �HS 4060 !SH 6050 Covered Patio Lattice Wall to 6- Tile 20' Ceiling 8' CeiiIing to 24'-100 3*-4m 39-4* 9*-2n 200 3061]1 FG 306� FG 3060 FG J; I Cf) 0 VL Remove Existing Bay window 0 0 0 \X 0 to 0 Floor /\x/\ to Sink < X 00 LL 73 r 0 J f- 00 > 0 *00 % Y\ to X For��Utp, �ia6o`qi 1 Soda I I Coffee I r All II I Remove Existing Walls-' Dininii� 3' minimum aisle 0 X N59-4" U 0 0 Co r l o r \< Remove Existing Drain (Existing) Lo Door and Sidelights. 01 >/ 0 dIC5 5' Turning ca ODrain Radius o-��30 ............... 0 0 0 .............. 5'-0* V-47 49-0* 00 ®0 , e V M 5' Turning Radius ro Drain N.� �_ <\ Replace with JVUO 0 00/ go Ext. Door with Self -Closing Hinge. > Weatherstrip U) 0 N Remove Existing U) 0 to x, > Bay Window 0 /N /<1 v �� �� �� ��� ���� ���� < X 0 Stone7,Clad Wall with Fountain, by others, AV` 04 CAD 0 0 . . . . . . . . . . . . . . 5050 HS Exit 69AM 13--1 01- 49-Ow 20'-2" 59'-10N 34--4ju 3'-1100 4'-2" 89-on 1-THE THE -fir'- T, A plan number 283G description Floor Flan X" date released revised sheet number 2 Kitchen Notes: Verify height of electrical and gas outlets. Provide electrical to vent system as required. Provide GFCI as required. Determine number and voltage of required outlets at Front Line. Determine and provide necessary voltage/amperage requirements for all large equipment. i �------------ ,� G IEE I I I I I I I I I 1 L---------------- Restroom Notes: Provide Electrical for Hand Dryers if required. Provide exhaust system as required. Provide Electrical for all Required "Exit" Signs as required by Code. Required. Design by Others. Add to Existing Electrical to Provide 8 total outlets at perimeter of Dining Area M Electrical Legend $ switch 3 way switch 4 way switch outlet switched outlet computer outlet sur("retented) Ve fy SeNer type an re RJ45 Connectoror4 0: gfci outlet ® weatherproof outlet 220 volt outlet light fixture ri wall mounted light ® recessed lite Q eyeball spot 40 mini —cans Irr = _ _ _ _ �1 24x48 I I j surface —mount IL------ JI fluo. fixture )—�- fluorescent ® heat, vent, light __0 doorbell pushbutton MD doorbell chimes N phone jack 0 smoke detector 0 exhaust fan N outlet verify service type p� garage door opener 'ng—fan-avith—G ceiling fan only O ` +�+ stub and brace for ceiling fan over light double ad'ustable gas Ocentral vacuum intercom ® exit sign emergency light ® fire extinguisher ® K—rated extinguisher plan number 283G description Electrical Plan date released revised sheet number W W IAdam� St. 1 N I N St. B St. !CC01 U co / Existing Landscaping Existing Grass Existing Indian Ha,/.thorn ' Proposed Landscaping E>:isting Heavenl�� Bamboo � IExist;-,g Trumpet Plant I , Proposed Palm Tree , ,; � _ Existing Sago PalYlr CExisting _repe Myrtle , i , I Proposed Nandina i O Existing H�-=-kherry O Existing Bradford Pe^r Proposed Crepe Myrtle,fit , 0 i L----------------------------------------------------------------- ------ ------ ------------ ------------ ------------� - —w—w—w—w w w w w w w w w w w w w w w w w ■e w w w Existing Gas S6NICe w—Ms—Ms—w—�s—w—w—Ms—w—Ms—Ms—w—w—Ms—w—w—rs—Ms—Ma—�r—w—rr—Ms—Ms—rs—Ms—Ms—w—w�- Manhole _ —=Existing 8" Sew rLine _ - - _ - _ Manhole _ _ _ Existing SS Tap _ _ _ _ _ _ ^ _ _ _ _ _Existing Overhead Electrical Service _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ —o — PP — — — — ' N 62° 45' 00" E 169.93Found I.P. FoundI.P. —" -------------------- ------ ---�----------- --4-1-------- --�--- ------------- ,------�- i--------- 1 s Exi fina Fire ; Du�pster °oe ----------I ----_----- °' l; W1/ I-�I - -- -- ydran° °90 - 1 MSD 10 Setback 1 Exis Conc. ------ ---J4------A----------- - --------------- \� I; ■ ■ ■ � Par ing _ Slope A-1111111111116 I " I I �� . �� I A / � � ( A/ =t � Vicinity I .Existing SS IC6-out 26 - rn , Proposed Gray Water Cleanout � (, Gasl Mqter I Q o �' ° o � Q a� Q v :2 O U W Il +' v c c o 0) -P L- o > % v c v 010 _ v — 3 O o O v U �-- 1--OU T N W (!) ,cam v w t I— N Q) Q v� c -Y •cn o -0 � � U O o t > z oao 60 N 0 O~� O co D a N E':-3 lei �>-� rn v �� v E v luIauny 1 1 v { j I i �o I I Slope 1 Slope 1 c> O (D ------------------------------- ------------------ I------------------------J • - }- � 1 2 1 3 // �� � 0 � 10 I 1 � ��MSD 10 Setback 'x I v'j.Lot 22-� ' Lot 3 I Lot 2 �� F� Lo I Lot 26 I Lot 25 20 I Lot 24 I Lot�23 Lot 1 1 , 1.-'------L__ —=�—� -�-- -----� - -- � Found I.P. Found 1.423 N 62" 45' 00 E 234.01 26'_,0 18' Instead of traditional grease trap, an upgraded AGI xti� Drive (Automatic Grease Interceptor) System will be y installed and utilized with sample well. 0- CITY APPROVING AUTHORITY CERTIFICATE Texas has approved this site plan and development ■ This is to certify that the City of La Porte, Main Street City of La Porte. E. of MAIN 101 GRILL AND BAR in conformance with the Ordinances of the y (1001 ROW) By: ----------------------------------------- Director, Planning Department SITE PLAN ACCURACY CERTIFICATE I, Billy L. Shanks, R.P.L.S. #1821, am registered under the laws of the State of Texas to practice the profession of surveying and hereby certify that the above plat or site plan is true and correct; and that all bearings, distances, angles, curve radii, and central angles are accurately shown_S, the plat. t► �G� s rf9��,�► BILLY L. SHANKB ,..� SZ•+y........r.�... 9 9��t1S1�? Billy L. , 4,,, hanks JOB NO. 34703 Name of Development: Main 101 Grill and Bar Development Type: Commercial restaurant Zoning MSD (overlay) Legal Address: 101 E. Main, La Porte, Texas 77571 Owner: Joseph Bertuglia Developer: Joseph Bertuglia Lots 1-4 and 22-26, Block 181, La Porte, Harris County, Texas Existing Sq. Footage 3321 Sq. Ft. Proposed Addtion 518 Total Footprint 3839 Sq. Ft. # of Existing Parking Spaces 20 Lot Footage 25,245 Sq. Ft. Landscaped Area 2250 Sq. Ft. 8.9% of total lot area TO 7 T a - r, Ems= 0��,:� plan number 283G description Plot Plan 1" _ 10, date released revised sheet number Field Verify All Dimensions Prior to Demolition/Construction. All new construction shall be indicated by shaded walls. 11 0 I C0 R 0 1 b M 0 I 0 79P_4. These drawings are not Intended to enumerate each and every piece of lumber, equipment, material or other necessary component required for the proper construction of this facility. Care shall be taken at the job -Site to ensure that construction meets or exceeds all applicable building codes. Karen Hamilton, Dimensions in Design, 15 not and does not claim to be an engineering firm. All required engineering shall be done by others and is not 15 this contract. Procurement of stamped, certified engineering drawings will be the re5pon5lblllty of the General Contractor. Occupancy: 150 1 11 00 go I I I N O O 10 O 1 i` to in O R O I N � R I O cop M R O I i� (n x plan number 283G description Floor Plan Y4w a 1 Pion date released revised sheet number 0 Kitchen Notes: Verify height of electrical and gas outlets. Provide electrical to vent system as required. Provide GFCI as required. Determine number and voltage of required outlets at Front Line. Determine and provide necessary voltage/amperage requirements for all large equipment. �-------------`� I I I I I I I 1 I EE IL---------------- Re5troom Notes: Provide Electrical for Hand Dryers if required. Provide exhaust system as required. Provide Electrical for all Required "Exit" Signs as required by Code. Provide Electrical for Fountain/Water Wall as Required. Design by Others. Add to Existing Electrical to Provide 8 total outlets at perimeter of Dining Area ,: IV , 1 = � •y Electrical Legend $ switch 3 way switch 4 way switch outlet --- switched outlet computer outlet 4 _verurfy s rrottrctede and-netwo[k - RJ45 Connector C-1 gfci outlet ® weatherproof outlet 220 volt outlet light fixture --------- -- -- ------------------- ® Q wall mounted light recessed lite eyeball spot mini —cans r — — — — — — 2448 Il ll surface —mount LL — ----JJ fluo. fixture —�( fluorescent ® heat, vent, light —o doorbell pushbutton ® doorbell chimes H phone jack ® smoke detector exhaust fan N outlet ven'fSr service type O� o garage door opener ceiling -fan- with -light- ceiling fan only stub and brace for ceiling fan over light double ad' stable aferprooMloodlights - gas — — Ocentral vacuum .� intercom ® ® exit sign emergency light fire extinguisher ® K—rated extinguisher plan number 2(53(S description Electrical Plan X" = i r�On date released revised sheet number Z �t W m • a m S3 o Er- 0- i z Z Cu to La aD w = m �Z cc z� • a Gzi � 00 8 a w KEY MAP LOCATION: 540Y MINOR DEVELOPMENT SITE PLAN ANTIQUES BY PARKER/TWO SISTERS TEA ROOM 101 EAST MAIN �---- TOWN OF La PORTE, HARRIS COUNTY, TEXAS TYPE OF DEVELOPMENT: FA ADDITION OF NEW PARKING DUE TO CHANGES IN BUILDING USE CODES OWNER: DEVELOPER: OWNER - TOM PARKER ZONED: COMMERCIAL 0 LEGEND LOT 23 2--- SS SANITARY SEWER (SIZE NOTED) -W WATER LINE (SIZE NOTED) 2---G NATURAL GAS LINE (SIZE NOTED) P--2 OVERHEAD ELECTRICAL POWER LINES(EXISTING) LOT 24 EXISTING FIRE HYDRANT T FH TREES - NEW w N TREES - EXISTING X7, N 27. 15' W 125.00' xZc ar cv 0- SHRUBS - EVERGREEN TYPE EXISTING 2 3 4 5 6 7 8 9 10 11 12 13 _ SHRUBS - SCREEN FOR DUMPSTER EXISTING w -- s� w o �X EXISTING ISTING ELEVATION o F o o B o <� 0 9' X 18' o EL. n.ts' X PROPOSED ELEVATION Lr)(TYP. 13) Ln CD LOT 25 �-E ELECTRICAL POWER LINES(NEW) w_.__ __._- - -�-- -- WATER METER �-------------------------- Lu w w © GAS METER z PROPOSED NEW SLOPE SLOPE o B _ o I SLOPE SLOPE _ Z - Q �: NOTES -----:- ASPHALT PARKING o N 3:: Z T N 1. THIS SITE PLAN IS NOT A SURVEY, BUT RATHER PREPARED FROM SURVEY DONE BY BILLY SHANKS, JOB #96-34703 DATED 10/30/96 Q LOT 26 0 2. THIS TRACT DOES NOT LIE. WITHIN THE 100 YEAR FLOOD PLAIN. 0-o J (ZONE X, PANEL# 48201 CO945J, REV. 11-6-96) B J (n EXIST. N 27' 15' W 125.00' SS TAP W W 3. LAND TO BE DEVELOPED AT THIS TIME CONSISTS OF S W LANDSCAPE LOTS 26 and 25, BLOCK 181, La PORTE, HARRIS COUNTY, TEXAS E O (EXISTING) Lo T 6" CO " ¢ 4. EXISTING DEVELOPED LAND - 8602.5 SO. FT., BUILDING = 3320 SO. FT., LANDSCAPED AREA = EXISTING N y y 6 200 AMP 317 SQ. FT. REQUIREMENT. CCnSLOPE SERVICE ENTRANCE EXISTING- ADD NEW TREE W y 5. EXISTING BUILDING CONSIST OF TWO OFFICES, SHOP & SHOWROOM EXISTING 4 SS EXISTING BUILDING OFFICE ONE = 306 sq. ft , DINNING RM = 510 sq. ft. B J EMPLOYEE TELEPHONE , 30, 20'-p„ 60 x 40 + 20 X BLDG, SET SHOWROOM = 1339 sq. ft , SHOP = 940 sq. ft. KITCHEN = 162 sq. ft. W y SERVICE 3000 SQ. FT. BACK o Q N CD6. PARKING SPACES ARE: 7 (EXISTING) EXISTING FIN FL EL. - 20.00' � TOTAL ADDITIONAL PARKING SPACES = 13 PARKING - GRASS AREA. (EXISTING) O DUMPSTER Ln LANDSCAPE -.4- THIS IS TO CERTIFY THAT THE CITY OF LA PORTE, TEXAS HAS ®r.� 0?" HC RAMP APPROVED THIS SITE PLAN AND DEVELOPMENT OF TOM PARKER (EXISTING) `� Z /TWO SISTERS TEA ROOM IN CONFORMANCE WITH THE ORDINANCES � OF THE CITY OF LA PORTE. �s sL-4— p � �^ ^ ^ C.". OPE B B: / x uP o--3v-� L'�/ I DIR CTOR, ANNING DEPARTMENT I PP + RASS 0 _ X ADD NEW TREE / , 4 x - w > R15X 1 , R35' tN Cl- EXISTING XISTING SLOPE -: �' PARKING O0 (^ AM REGISTERED UNDER TH LAWS OF THE STATE OF _ v J i, BILLY L. SHANKS, SURVEYOR AND HEREBY FI�YDRANT H 5 TEXAS TO PRACTICE THE PROFESSION OF LAND EXIST. WATER METER ART 18'-0" 31'-0# 18'-0a CERTIFY THAT ABOVE SITE PLAN IS TRUE AND CORRECT; AND THAT ALL cep., h' 2 ` BEARINGS, DISTANCES, ANGLES, CURVE RADIUSES, AND CENTRAL ANGLES I 4p61' SLOPE I ARE ACCURATELY SHOWN ON THE PLAT. OF Q 0 3 f� BILLY L. HANKS R.P.L.S. # 1821 BILLY-L. SHANKS 6 ��� , •+ tszt is T> •Al}J `� J DATE: IF %'Os8S'% {0 14 EXIST. EXISTING CONC. DRIVEWAY WATER TAP \ y y FILE: E:\PROJECTS\2001\103\TP-SPI-B.DWG SITE LOCATION B 1/01 2001103 ADDED LOTS 26 & 25 PARKING; UPDATED SITE PLAN TJG NO, DATE ACC'T. DESCRIPTION BY APP'D. REVISIONS 1 B Tech —Sys Cad Design B D o EXISTING CONC. DRIVEWAY � • PH: 281-541-5459 3814 Tripoli Dr., Pasadena, Texas 77505 �- MINOR SITE PLAN — ANTIQUES & GIFTS OD� BY PARKER/ TWO SISTERS TEA ROOM �-- - 4�-� ` 101 E. MAIN ST., LA PORTE 1. / DATE II96 DRAWN T. GEORGE � DWG. NO. REV, N0. CHECKED `I'p SCALE P = 10' 1 APPROVED Tp ACC'T. 2OOl lO3 S P — 1 APPROVED EST. t G r i u - „y,� n, � KEY MAP LOCATION: 540Y MINOR DEVELOPMENT SITE PLAN _ ANTIQUES BY PARKER 100 EAST MAIN TOWN OF La PORTE, HARRIS COUNTY, TEXAS TYPE OF DEVELOPMENT: OFFICES OWNER: TOM PARKER 310 W. MAIN ST. LA--PORTE, TEXAS 77571 281-470-6614 PROPOSE SS TAP i G T PROPOSED 200 AAUP ro w :.n G.o 7/7/ / J// / / -- PROPOSED TEEFHONE SERVICE PROPOSED 4"SS N 27' 15 W 125.00 v--y---...►_--.�yr .I-���I' - W V' 1' `V \ Y W W W W W J L W _J.33' _ _ _ '77-7_ _ EL. 1"3.33' ► c�=���_$ b+ c i�V� F/ 717 6 co r, ^ 6 W Y y r,y y = PROPOSED NF-W BUILDING y w W° .. ' y W W y J 68x 40 + 20 x 30' V JJ -1 V ��•� 3320 SO. F1'. FIN FL EL. = 20.00' X X EL 19,33' y y GRASS AREk y - W V J. y W Y '1 y V' GF1(►� O HC RAMP y W W y y v may/ � In REY y J 'YY y y 1 '+ `Co �4t(+Jl' EL 19.33' X lip y y y b5 c4�sy Y`�r�s LTV p%jAl'� L�•y _, b•I I'�. �Q� .—._fir..— W 3, •V J��, 4�V 'GRASS ����i„ r:,y ri ,}, i, V, LEGEND 2--- SS SANITARY SEWER (SIZE NOTED) r--- W ---� WATER LINE (SIZE NOTED) �--i NATURAL GAS LINE (SIZE NOTED) r P- OVERHEAD ELECTRICAL POWER LINES(EXISTING) 4 -X-X-x-A A 6' CHAIN LINK FENCE W/1' BARB a ` WIRE ON TOP Y_ EXISTING FIRE HYDRANT +FH SHRUBS - EVERGREEN TYPE SHRUBS - SCREEN FOR DUMPSTER �IX EXISTING ELEVATION EL.17.16'X FROPOSED ELEVATION Y �- EELECTRICAL POWER LINES(NEW) ry' WATER METER R © GAS METER p i5 NOTES.. _ # - - - 1. THIS SITE PLAN IS NOT A SURVEY, BUT RATHER PREPARED FROM SURVEY DONE BY BILLY SHANKS, JOB #96-34703 DATED 10/30/96 2. THIS TRACT DOES NOT LIE WITHIN THE 100 YEAR FLOOD PLAIN. (ZONE X, PANEL# 4-854870340G, 9-28-90) 3. LAND TO BE DEVELOPED AT THIS TIME CONSISTS OF LOTS 1 THRU 4, BLOCK 181, La PORTE, HARRIS COUNTY, TEXAS 4. DEVELOPED LAND = 8602.5 SQ. FT., BUILDING = 3320 SQ. FT., LANDSCAPED AREA 317 SO. FT. REQUIREMENT. o� ► 5. PROPOSED BUILDING SHALL CONSIST OF TWO OFFICES, SHOP & SHOWROOM f / OFFICE ONE _ 306 sq. ft , OFFICE TWO = 63 sq. ft. ��/ SHOWROOM ._ 1360. sq. ft , SHOP = 920 sq. ft. , KITCHEN = 162 sq. ft. F PAPVINr CPA(Fq ARF• WMIN) PFR PI AN RFVIFW I coo 96 - SZ2s W Tyler. c�a 0 m z W Adam 5 St. W PolkE t. i c 6 t z v 14 z z z I z 12 9� P N W A St d W B St. vi i in co C0 Ti Cl) N L11 U) coU) I I __j Vicinity Map O 4-j a C Cn _C: W o -� U ++ Boa) c t� +j +, L- O >%0 c 0 �p 4- c O = :3 O � 0 O O _O +, -, L .j Za 0 X to :3 -0 p L.LJ Lt.l 00 ~ Q 0-� ON O .� to O •- U O p 00 -0 mot' V) -t ++ U O O O- _O LL Z C: 0 N N o p cnoaN o0 i cn>v � >-� a) 0 �>- 0 I1— E o Z� '0. Found I. R10' 1 / Existing Landscaping Existing Grass I / Existing Indian Hawthorn Proposed Landscaping Existing Heavenly Bamboo Existing Trurrpet Plant I , / Q Proposed Palm Tree i i bisling Palm I �� � Existing Crepe �'yrtle ' ^ I / Proposed Nandina I IL ' \ 1 / 0 Existing HackberryExisting Bradford Pear 0 Proposed Crepe Myrtle -----------------------------------------------------------------------------------------------------------------� - Existing Gas Service Manhole Existing 8" Sew r Line Manhole — Gu3uoiy JJ fuN Cxisting Wemeaa CIeCLrIWI aervico — SZN PP Found I.P. 15• sample well N 620 45' 00" E o 169.93'---------0\7 o o Found I P. 44Z Grease _, Exi> ing SSea�nou )EAin�gg Fire ; Dumpstler ;Trap I ( ' I °oe Hydrant 1 I /.7\0 '0� 1 I I `D 9 I I MSD 10 Setback I �I -------- ling C nc.-------%-------�----------------�---------------------- -------------------=------ PaI cn --�z I _slope I6° Prolrfosed Gray Water Existing Drive / 20 Wide Q X - • 0 c fi 1 1 1 26'-Of Cleanout ' I 0-Gas er I 10 ;; I Existing 200 amp service I ' entrance I Existing Telephone Service I ; 1 1 I I I �n I 0 o ° I, 0 I 1 f Slope / I II I LLJ Q I I I i I z q1 I Slope I Slope I `jr q,ajI I , � O on- 19 L--- - - - - - - - - - ---- -- --- - -- -------- --- ------ -------- r ------------------------------}-------------------------------------}------J I 'X 1 2 I 3 I ._ o I I I tMSD 10 Setback I ``J Lot 3 1 LOt 2 Lo I Lot 26 1 Lot 25 20 1 Lot 24 � I Loti23 (� Lot 22� Lot 4 W 1 I ------------ --- —=T � ,� , I I Found I.P. N 62e 45 00 E 234.01 Instead of traditional grease trap, an upgraded AGI (Automatic Grease Interceptor) System will be installed and utilized with sample well. 26'-7" %Mna,Drive 0 CITY APPROVING AUTHORITY CERTIFICATE This is to certify that the City of La Porte, Texas has approved this site plan and development of MAIN 101 GRILL AND BAR in conformance with the Ordinances of the City of La Porte. E. Main Street (1001 ROW) By: ----------------------------------------- Director, Planning Department 18' Name of Development: Main 101 Grill and Bar Development Type: Commercial restaurant Zoning MSD (overlay) Legal Address: 101 E. Main, LaPorte, Texas 77571 Owner. Joseph Bertuglia Developer: Joseph Bertuglia Lots 1-4 and 22-26, Block 181, La Porte, Harris County, Texas Existing Sq. Footage 3321 Sq. Ft. Proposed Addtion 518 Total Footprint 3839 Sq. Ft. # of Existing Parking Spaces 20 Lot Footage 25,245 Sq. Ft. Landscaped Area 2250 Sq. Ft. 8.9% of total lot area SITE PLAN ACCURACY CERTIFICATE I, Billy L. Shanks, R.P.L.S. #1821, am registered under the laws of the State of Texas to practice the profession of surveying and hereby certify that the above plat or site plan is true and correct; and that all bearings, distances, angles, curve radii, and central angles are accurately shown on the plat. Billy L. Shanks JOB NO. 34703 plan number 283G description Plot Plan in — 10, date released revised sheet number To C -- (::) K— 7) 3 2- 9 tf 84; 6 e Le. w La4_j 3 2- q 6 � ---1) 6 0