HomeMy WebLinkAbout1101 S BROADWAY ST_17-2014___________1101 S BROADWAY ST i City of La Porte 604 W Fairmont Pkwy La Porte, Tx 77571 (281)470-5073 INSPECTION LINE:(281) 470-5130 ****BUILDING PERMIT**** ------Pp---------------- ----------- --------- Application Number . . . 17-00002014 ----------- Date 1/04/18 Property Address . . . . . . 1101 S BROADWAY ST HCAD Number: 024-189-010-0001 Alternate Search Method: Application type description ADDN, TANK INSTALLATION Subdivision Name . . . . . . LA PORTE Property Use . . . . . . . . REAL COMMERCIAL Property Zoning . . . . . . . COMM - GENERAL Application valuation . . . . 150000 ------ ------------ Type of Work underground storage tank ---------------------------------------------------------------------------- Owner Contractor ------------------------ --------- -------- JACKS PLAZA LLC GEO ENVIRONMENTAL CONSULTANTS 1101 S BROADWAY ST 40 LYERLY LA PORTE TX 77571 HOUSTON TX 77022 (713) 695-4708 -------------- Structure Information 000 000 - ------------ Construction Type . . . . . NON-COMBUSTIBLE II Occupancy Type . . . . . . MERCANTILE Flood Zone . . . . . . . . ZONE AE ---------------------------------------------------------------------------- Permit . . . . . . BLDG PERMIT -FIRE SUPPRESSION Additional desc . . UNDERGROUND STORAGE TANK Permit pin number . 556878 Permit Fee . . . . 912.50 Plan Check Fee 456.25 Issue Date . . . . 1/04/18 Valuation . . . . 150000 Expiration Date . . 7/03/18 Qty Unit Charge Per Extension BASE FEE 687.50 50.00 4.5000 THOU BLDG - 100,001 - 500,000 225.00 ---- ------------------ Special Notes and Comments Under Ground Storage Tank 1. Call for inspection .2. As per Fire Marshall plan review and notes. 3. This permit is for underground storage tank. 4. Contractor/owner responsible for removal of all construction debris. S. A building permit and all its applicable sub permits may be based on the remainder of the work to be done. However if the work is not completed City of La Porte 604 W Fairmont Pkwy La Porte, Tx 77571 (281)470-5073 INSPECTION LINE:(281) 470-5130 • ****BUILDING PERMIT**** ------------------------------------------------------- e 2 Page Application Number . . . . . 17-00002014 -------- ----- Date 1/04/18 ------------------- Special Notes and Comments within the allotted time of the renewal period, the building permit and all applicable sub permits must be applied for as a new permit, and all permit fees will be calculated from the original permit valuation. ------------------------------------ --------------------------- Fee summary Charged Paid ---------- -- Credited Due - ----- ----------------- ---------- Permit Fee Total 912.50 912.50 .00 .00 Plan Check Total 456.25 456.25 .00 .00 Grand Total 1368.75 1368.75 .00 .00 OF CONTRACTOR OR AUTHORIZED AGENT (APPROVED BY BUILDING OFFICIAL OR AUTHORIZED %LTT) DATE Y Md.... SebcI PoU� ,wmoa onm_ ' Parcel Inquiry Address: MULTIPLE ADDRESSES WERE FOUND AT THIS PARCEL Main address: 1101 S BROADWAY ST CUP ub 1 Sub 2 Blk Lot 24 189 010 0001 parcel processing code: Effective date, status: 0/00/00 Active PARCEL OWNER 1101 S BROADWAY ST LA PORTETX 77571 i L2EGEIVE, 2017 COMMERCIAL PLAN REVIEW COVER SHEET (INTEPNAL USE ADDRESS: I o J S 1A0,4 - .* � e OWNER'S NAME:6 17:7Nv!A..,, _44 ( Cast.. (.4� s PROJECT TYPE: Pnr k NEW: ADDN: HCAD#: HTE LOC#: FLOOD ZONE: USE ZONE: Y/N SUB /DATE RETURNED TIRZ ZONE? SM VISIT (DRAINAGE) ZONING PERMIT CERT. SITE PLAN APPROVAL ASBESTOS SURVEY RECEIVED TAS (ADA) PROOF OF SUBMITTAL F101 RESOL. APPLICABLE?: F216-00-00 RESOL. APPLICABLE?: FILL DIRT APPL/PERMIT CLEARING PERMIT NEE, DED? FLOOD PERMIT NEEDED?: W/S FEES APPLICABLE?: 100% MASONRY/GLASS STORM WATER QUALITY PERMIT TAXES UP TO DATE?: DATE OF REVIEW: ITEMS NEEDED FOR ISSUANCE OF 1. CURRENT INSURANCE CERT. (if (Applicable on Demo, Addn, or Remodel) (Applicable to Comm. Or Ind.) (If yes, permit cannot be issued.) (If yes, permit cannot be issued.) (If yes, figure fees. If no, use w/s form to explain why they are not.) OK OWNER OR CONTRACTOR NOTIFICATION DATE TIME NAME OF PERSON CONTACTED —Eo0•'l pall PJ1gs MAf I S:\CPShue\WSP=ON DMSION\1mpecdom\COML PLAN REVIEW COVER SHEET.doc Rev. FEB2012 INSPECTION SERVICES BUILDING PERMIT CHECKLIST (COMMERCIAL) Job Address: Owner Name: Flood Type of Work: New Remodel Addition Date Received in Inspections: Legal Description: Zoning: Allowable Use? Y OR N a Street/Alley Closing Action? Ord. #s: Complete and accurate construction drawings (all phases) are one of the most important steps in completing your project. They will be used to cost out the job, get estimates from any subcontractors, show details in legal documents, and to obtain necessary permits. FORMAT Furnish two sets of construction documents including the following items: Survey of Property (SBC 104.2.5) Yes or No Certified Site Plan to Scale indicating: (Dev Ordinance 1444)Yes or No (If required by Planning Department) (Appendix E) • North Arrow (Dev Ordinance 1444)Yes or No (Appendix E) • All existing & proposed construction (Dev Ordinance 1444) Yes or No (Appendix E) • All required building setback lines (Dev Ordinance 1444) Yes or No (Appendix E) • Utility Easements/Alleys, Streets (show if applicable) (Dev Ordinance 1444)) Yes or No (Appendix E) • Distance for proposed structure to property lines (Dev Ordinance 1444) Yes or No (Appendix E) Inspections Division Building Permit Checklist Page 2 • TIRZ Zone? • 100% Masonry/Glass • Storm Water Quality Permit • Zoning Permit • Asbestos Survey (if applicable) • Energy Code Analysis (if applicable) • TAS (ADA) Proof of Submittal • F101 Resolution applicable • F216-00-00 Resolution applicable • Utility Verification Needed (CDR) • Address Request Needed (CDR) • Culvert Request Needed (CDR) • Harris County Driveway/ Culvert permit received? • Harris County Health Dept. (Restaurants) approved "Plans Review Information Report" received from Hams County? • Fill Dirt Permit (if applicable) • Clearing Permit (if applicable) • Flood Plain Development Permit (if building is in "AE" or "VE" flood zone) • Water & Sewer Fees Applicable • Completed Petition to Tie on to Existing Water/Sewer Mains • Sample Well Proposed? • Current Certificate of Insurance • Construction Drawings with Engineer's Seal (if applicable) Foundation Plans d• Structural Framing Plan ❖ Exterior Elevation Plan Electrical Drawings ❖ Plumbing Drawings ❖ Mechanical Drawings ❖ Drainage Plan ❖ Slab Elevation (if applicable) Yes or No Yes or No Yes or No (City Ord 106-142) Yes or No (State Law) Yes or No (State Law) Yes or No (State Law) Yes or No (CLP Resolution) Yes or No (CLP Resolution) Yes or No (City Ord 106-141) Yes or No (City Ord 106-141) Yes or No (City Ord 106-141) Yes or No Yes or No Yes or No (City Ord 1444-A) Yes or No (City Ord 1501-R5) Yes or No (City Ord 194-63) Yes or No (Ord 759-F) Yes or No (Ord 759-F) Yes or No (City Ord 74-121(c) Yes or No (City Ord 82-35) Yes or No (State Law) Yes or No (State Law) Yes or No (State Law) Yes or No (State Law) Yes or No (State Law) Yes or No (State Law) Yes or No (State Law) Yes or No (State Law) Yes or No (State Law) Yes or No SACPSh=\INSPECTION DIVISIONUnspectionsUdg P Checklist Coml.docJu12011 1101 S. Broadway Underground Storage Tank 1. Call for inspection 2. As per Fire Marshall plan review and notes 3. This permit is for Underground Storage Tank 4. Contractor/owner responsible for removal of all construction debris 5. A building permit (and all its applicable sub permits) may be based on the remainder of the work to be done. HOWEVER, if the work is not completed within the allotted time of the renewal period, the building permit (and all applicable sub permits) must be applied for as a NEW permit, and all permit fees will be calculated from the original permit valuation. liTy copy ONINn10n IM110 9H101 1Viild NlS IVIO V '!JOV1 aav Sfdtlln u3Ji`vZo�� �;;1 �I LA PORTE FIRE MARSHAL'S 1°'1Ir t OFFICE FF:: "PLAN REVIEW" Date 01/02/2016 Business Name Jack's Groceries #14 Address I101 S. Broadway Type of Review Underground Storage Tank (UST) Contractor TBD Reviewed by Clif Meekins, Fire Marshal City Permit # 17-2014 Approval YES The Applicant shall be responsible to ensure me design speclbcations and plans am complete and In compliance wlm me requirements set roan in me zaio International Fire Code (IFC) and Local Amendments as well as the applicable referenced Standards listed in Chapter a5 of the 2015 IFC. This plan review is not intended to be fully inclusive as other requirements may be imposed as warranted by the Fire Marshal or as deemed necessary during on -site inspections by the Fire Marshal's Office. 1) CONTRACTOR SHALL CONTACT THE FIRE MARSHAL'S OFFICE FOR INSPECTIONS OF: a) Underground tank excavation and observation of tanks BEFORE placing in the ground. b) Pressure test shall be done in accordance to the manufactures instruction. A copy the manufactures instruction/test procedure shall be onsite for Fire Marshal's Office testing. c) Final inspection of monitoring system sensors, emergency/automatic shut -offs, overspill/overfill prevention equipment, protective bollards (if applicable), and signage. 2) A licensed technician shall be on site the day of Fire Marshal's Office testing 3) Approved (Stamped) copy of the plans shall be on the job site and available to the Fire Marshal Inspector at any time during installation. 4) Remote fuel shut-off shall be installed in a conspicuous place and clearly labeled. The remote fuel shut-off CANNOT be controlled by a computer or by having to access the cash register. )AN 0 3 2018 } '(0 flit �rvv`. 125 South T'Street, La Porte, TX 77571 * Office: 281-867-4603 * Fax: 281-867-4629 4 G E O Environmental Consultants. Inc. _® 40 Lyerly Street, Houston, Texas 77022 Contractor: Geo Environmental Consultants, Inc. Contact: Marco Alegre (713) 695-4708 geoarch 1 @geoenvconsultants.com Site Address: 1101 S Broadway St LaPorte, Texas 77571 Scope of Work: Phone:(713)695-4708 Fax:(713)695-5736 1. This site is an existing convenience store 2. Removal of three (3) Underground Storage Tank (UST) 3. Installation of one (1) underground fuel storage tank of 30,000 (18+6+6) gallons 4. Installation of double wall fiberglass, underground product lines, and steel Bollards 5. Installation of four (4) fuel dispensers Please find the attached: Manufacture Specs. SitePlan ........................................................................................SP1 Fuel Tank Details...............................................................................FPI FuelTank Notes.................................................................................FP2 FuelDetails.........................................................................................FP3 FuelDetails.........................................................................................FP4 ECEIV�= i DEC 2 Z 2017 LJ L--iJ O d d p UV U LJ9 DR3 �a UV a f1 U Parking: Standard size is 9'x18' with 25' dr' 9 Ive aisles. Parking requirements are outlined in Article VI of:Chapter 106 of the city's Code of Ordinances. Accessible parking required in accordance, with ADA/Texas Accessibility -- --—CEN1ERLINE h,R ROAD Standards. Include parking table. 1 Not : Loois ^P wit 4 tr s 7A,1.) A Iq A 9 PARKING TABLE Parking Spaces Required (Include parking ratio from Section 106-839): 4+10 = 14 Parking Provided: 22 Accessible Parking Spaces Required: 01 Accessible Parking Spaces Provided: 01 Q dolt IV Tr A EXISTING CONCRETE DRIVEWAY EXISTING CONCRETE DRIVEWAY LIB' ------------ -- SIDEWALK N87002'28 "E - 166.68' o .� r- even, .w...., ,. ...... F ,L EXISTING r I ibe 2d' �O'L�j�tC 43'-8" g' CONCRETE 36, 4 a 20' BUILDING LINE 0 I 'Q w 15 �w .--�-- `41 � P•.WAa.iaw• _ ee.® p r I Q x kd.� 27'-5" i � - wI nQ 5�:�.r Q � ► I C� w l W ck:�I U M� 1 z �1 d I k • �' ••• ; � pP 'D o zl > I I a X1 Y � d •� I o w Q r t i ( 7 3� ram_ �9 ` o° (/) U X Z ° C7 kQ• �• I °- o, I 1 ��A A • I I - 40 I EXISTING CONV. EE STORE 3,200 Sq.Ft. I (1 STORY) I I L dL- I 4 SPACES 18' TYP. I {Co m tV PROPOSED: 1000 GREASE TRAP 7:,0 GAL. & 7 SAMPLE WELL BLOCK 1110 TOWN OF LA PORTE rec. in Vol. 60, Pg. 115 H.C.D.R. r� I � D I o i 1 ` NO DRIVE THRU ON PROVIDE EX STD ' TFIIS PROJECT o CA i DUMPSTER i a Li �I Lol CURB TO BE--------,-_—.� LOWER TO EXISTING GRADE. I SUBJECT TRACT 0.693 V t I ACRES or 30 181.09 S . Ft I I 15' I EXISTING ( 1 q �. , �_..• CONCRETE I LOTS -E�k � t t hr u 6 8 31 & ' N 1 (( �I i TRACKS 7A, 12A, 14A, 30A 81 Track "A' ' W ! (PT ABANDONED 16-ft ALLEY) ZO LA PORTEEXI' iTly 16' 8' IL � — —EXISTING CONCRETE— — — — `- — — — — — — — -- -- CONCRETE TO E REPLACED WITH NEW - �,�� ; EXISTING CONCR Q 24 -� NEW CONCRETE CONCRETE AT SAME GRADE. OPOSED TANK LOCATI�V TANKS &CANOPY AREA -- ---- - - - N I F EL SYSTEM PERMITTE I 111 SPACESI { ' 6 �� 1 BSE' ARATE4Y i 6 9' SIDE SETBACK I i } 1TYP.VEINS 2001011 ' n S 7°O1'00"W '-- 48.59' NO3°36' 4" - 7. 00 01 s E ILA i� N — ... o r !r S87 00 27 W 118.07 w : ;,.' EXIST. TREE IF T E APPROVED PLANS ARE MO FIED, ANEW SUBMITTAL ; `;' < 1 1 TO THE ITY IS REQUIRED PRIORI TO T E CHANGE OCCURINC- TOWN OF BLOCK PO LA FORTE Z ( rec. in Vol. 60, Pg. 115 H.C.D.R. I r= i wi JOHNSON HUNTER SURVEY, ABSTRACT 35 SCOPE OF WORK: EXTERIOR & INTERIOR IMPROVEMENT / REMODELING. S. W. Q, P- # 17-82 ZONING PERMIT # 17-81 ANY NEW OR PROPOSE SIGNAGE SHALL BE UNDER SEPARATE PERMIT. MINN LIGHTING AND GLARE: ANY LIGHTING USED SHALL BE ARRANGED SO AS TO DEFLECT LIGHT AWAY FROM ANY ADJOINING RESIDENTIAL ZONE OR FROM PUBLIC STREETS. DIRECTOR SKY-REFELCTED GLARE, WHERE FROM FLOODLIGHTS OR FROM HIGH TEMPERATURE PROCESSES SUCH AS COMBUSTION OR WELDING SHALL NOT BE DIRECTED ONTO ANY ADJOINING PROPERTY. THE SOURCE OF LIGHTS SHALL BE HOODED OR CONTROLLED IN SOME MANNER SO AS NOT TO LIGHT ADJACENT PROPERTY. BARE INCANDESCENT LIGHT BULBS SHALL NOT BE PERMITTED IN VIEW OF ADJACENT PROPERTY OR PUBLIC RIGHT-OF-WAY. ANY LIGHT OR COMBINATION OF LIGHTS WHICH CAST LIGHT ON A PUBLIC STREET SHALL NOT EXCEED ONE FOOTCANDLE (METER READING) AS MEASURED FROM THE CENTERLINE OF SUCH STREET. ANY LIGHT OR COMBINATION OF LIGHTS WHICH CASTS LIGHT ON RESIDENTIAL PROPERTY SHALL NOT EXCEED 0.4 FOOTCANDLES (METER READING) AS MEASURED FROM SUCH PROPERTY. RADIATION AND ELECTRICAL EMISSIONS: NO ACTIVITIES SHALL BE PERMITTED THAT EMIT DANGEROUS RADIOACTIVITY BEYOND ENCLOSED AREAS. THERE SHALL BE NO ELECTRICAL DISTURBANCE ADVERSELY AFFECTING THE OPERATION AT ANY POINT OF ANY EQUIPMENT OTHER THAN THAT OFTHE CREATOP -)F SUCH DISTURBANCE. SMOKE: THE EMISSION OF SMOKE BY ANY USE SHALL 13E IN COMPLIANCE WITH AND REGULATED BY THE APPROPRIATE FEDERAL, STATE OR LOCAL AGENCY. DUST OR OTHER PARTICULATE MANNER: THE EMISSION OF DUST, FLY ASH OR OTHER PARTICULATE MATTER BY ANY USE SHALL BE IN COMPLIANCE WITH AND REGULATED BY THE APPROPRIATE FEDERAL , STATE OR LOCAL AGENCY. ODORS: THE EMISSION OF ODOR BY ANY USE SHALL BE IN COMPLIANCE M11TH AND REGULATED BY THE APPROPRIATE FEDERAL, STATE OR LOCAL AGENCY. EXPLOSIVES: NO ACTIVITIES INVOLVING THE STORAGE, UTILIZATION, OR MANUFACTURE OF MATERIALS OR PRODUCTS SUCH AS TNT OR DYNAMITE WHICH COULD DECOMPOSE BY DETONATION SHALL BE PERMITTED EXCEPTSUCH AS ARE SPECIFICALLY LICENSED BY THE CITY COUNCIL. NOISE: ALL NOISE SHALL BE MUFFED SO AS NOT TO BE OBJECTIONABLE DUE TO INTERMITTENCE, BEAT FREQUENCY OR SHRILLNESS AND AS MEASURED AT ANY PROPERTY LINE IN ACCORDANCE WITH THE DECIBEL LEVELS OUTLINED IN SECTION 106-310 OF r f 1 t rr .a.. a 4• };0 1-' SITE.`,' 4 'Z'I ir', tr I: ��itit �`Jtulr ` .�..•?y7�I'IwI:Ii r }}=w y '}6klrllt� St �lll(�tll •� E ,Ili I t}V, '.ai•,: r,iJ ll. �!-. rr1`:.i,tJ' '•y i' a fr '{''+t 4 f : 1 Ef� I�r � Jl�yjjJ ) I� •.1 t (�•r•I'�rlt,Ul��lh,•Ilhi � I •'�; 11I •'I:EBRASkA. TI.i✓Z., ,..-- _•!,:iri L!R14r1.: Ran. !�I. ..•..,, '.rri, ar..Jffig IN :;:; •: ,.4r. •,,.L:uorrEarecu' ':''i .r f. + 1 1 41 h+ 1 '.1 {r T,� ti 11 • a , _ I I+ ti ".. I • h rl + 'd'NC,T•"r•a I•DflD' .. •;};,.i,�(;%)11j?l,I;{!;{Wit 1tl .1G r 3'.� •� '.y ,il llil li i�:{il'};l �it"r ililllripil LrJ K1'r174 1 R.i jld!jl;'`;;;i.;lill ! )1 r •1:'d �)'I1�'1°+';G?tlN i.�4iflr�; ;I � }_. •,,;''l, (t;lt!ill P: ... �• . •. .. etr v :: I��' j.li mil w. r Ir.,!'j�t'V'+ IIlii {� Gti, Ia.;aYa� 1 ft f i"4ie { �plll�(;ll�lll�i}I'Jiall'li� ilr {� :;' •. iIT i�kr I,Ij 5It, IPjid {r �r 1. ,r 1 t ,r''}� ri E!i �(• 'I; td 1 i II "� t j� �:r4,Ai�14�,'4 � '1 •I'i° -,�` t14 nA pDur +', s, n : � . dl� l i' 11 I Ij �(•l r , lj}�, ,.�.� t + l� �j ltil� llY�l�! .:td KEY MAP: 580-G NAP SCALE L- . SOW FIRM FLOW NUFANCF RAIE w 11A N1111. CD m Yr5' a„. ' er PANELf1i CF It5t FIRM: 48201 C-0945M FLOODPLAIN NOTE: THE SUBJECT PROPERTY LIES WHOLLY THE LIMITS OF 100-YEAR FLOOD HAZARD ZONE ACCORDING TO THE MAP PUBLISHED BY FEDERAL EMERGENCY MANAGEMENT AGENCY, AND HAS A ZONE "AE" RATING AS SHOW BY MAP No, 48201C-0945M DATED JANUARY 6, 2017 BASE FLOOD ELEVATION IS 14.0 FEET OWNERS CERTIFICATE: I IQBAL ABDULLAH PRIES., JACK'S PLAZA LLC., AS OWNER OF THE 0.693 ACRE TRACT DESCRIBED IN THE ABOVE AND FOREGOING SITE PLAN OF JACK'S GROCERY NO.14 DO HEREBY ESTABLISH SAID DEVELOPMENT OF SAID PROPERTY ACCORDING TO ALL LINES, DEDICATIONS, RESTRICTIONS AND NOTATIONS ON SAID SITE PLAN. I (WE) FURTHER CERTIFY THAT ALL IMPROVEMENTS SHOWN ON SAID SITE PLAN SHALL BE CONSTRUCTED IN THE LOCATIONS SHOWN. IN TESTIMONY WHEROF, THE JACK'S PLAZA LLC HAS CAUSED THESE PRESENTS TO BE SIGNED BY IQBAL ABDULLAH, IT'S PRESIDENT THEREUNTO AUTHORIZED, ATTESTED BY IT'S SECRETARY, ZAHID RAZA, AND IT'S COMMON SEAL HEREUNTO AFFIXED BY THIS 0'�4 DAY OF Se>i�- . 2017. BY: 4� 6,4W , , AUK 5 HLAZA LLC, ATTEST: �-11-----' I y"\ r 11 AZA, SECRETARYI CITY APPROVING AUTHORITY CERTIFICATE: THIS IS TO CERTIFY THAT ON DAY OF 2017 THE CITY OF LA PORTE, TEXAS HAS APPROVED THIS SITE PLAN AND DEVELOPMENT OF IN CONFORMANCE WITH THE ORDINANCES OF THE CITY OF LA FORTE. BY: • DIRECTOR, ?ro7-- PLANNING AND DEVELOPMENT ~CITY PLANNER NAME OF DEVELOPMENT: JACKS GROCERY TYPE OF DEVELOPMENT: MERCANTILE- — RETAIL ZONING: GENERAL COMMERCIAL OWNER: JACKS PLAZA, LLC DEVELOPER: AXIS DEVELOPMENT HCAD PROPERTY ID: 0241 8901 00002 LEGAL DESCRIPTION: LTS 1 THRU 6 & 31 & TRS 7A 143-A 14A 30A & TR A (PT ABND 16 FT ALLEY) LA PORTE N.A.I.C.S. NO. 447110 — Gasoline 'stations with convenience sores SPECIAL VARIANCE: #17-93 000 001 FILING DATE: umamlvlI WP PEN! a 4ANYARrt nff ® ■ y i , ! 4 A a.n4.., CISNERG DESIGN r GROUP 2501 W 11 th S,,% HOUSTON Try 77000 A OFFICE: V i 713. 524. 2B80 FAX: 713. 524. 9E103 1 f. F. eMAIL: ;+ cisneros @ ciis-axiis.corn Il SEAL: OF *' w ' L Jonar= LU15 :. 4 5 I JORGE L. TREVINO, P.E. JL Trevino & Assoc. TX F-10510 9800 Northwest Frwy., Suite Houston, TX 77092 — (281)433-6 66 J LU } L 1 1 W U 0 2 LU Ito * Ig ■ � 1 a LU U 0 Tm V U W O ir a ME r o REVISIONS & DAT 1) 06/26/2017 08/10/2017 08/22/2017 DRAFTER: GERARDO DATE: May 2nd, 2016 I ' C i SCALE: 1 = 20' SHEET NO. I 1. DEC 2 7 1 FUEL VENT PIPES TO GO THROUGH CANOPY COLUMN MIN 35' TO PROPERTY LINE c� T.O. CANOPY CIA EL.: 19'-0" A,F.F. 1 B.O. CANOPY `o EL.: 15-9" A.F.F, 16-0„ HEIGHT OF CONTROLS EL.: 52" A.F.F. MAX. CANOPY ELEVATION SCALE: 1" = 10' DEVELOPMENT SITE PLAN SCALE: 1 " = 30' 7IVTA9 -1 1101 SCALE: 1 " = ate' - 18" 0 x 3/8" ROUND COLUMNS (TYPICAL) FUEL DISPENSERS 6" BOLLARDS I TANK NOTES I • THE FACILITY SHALL COMPLY WITH NFPA 30A. • INSPECTION WILL BE REQUIRED FOR THE DELIVERY AND INSTALLATION OF THE UNDERGROUND FUEL STORAGE TANKS AND PIPING. • THE GAS TANKS SHALL BE DOUBLE WALLED FIBERGLASS AS MENUFACTURED BY CONTAINMENT SOLUTIONS. I A.D.A. NOTE: I THE HIGHEST OPERABLE PART OF CONTROLS, DISPENSERS & RECEPTACLES SHALL BE PLACED WITHIN AT LEAST ONE OF THE REACH RANGE SPECIFIED IN SECTION 4.2.5 AND 4.2.6 OF THE TEXAS ACCESSIBILITY STANDARDS. FA�G3Ci�'vOf�i� p1�1G3f�n,�7 �su��5i� ENT SITE PLAN #11 o d Goa Wago M.&MpD TOWN OF LA PORTE t$c. In Vol. 50, Pg. 115I1.C.DA. 4Y 8" CONCRETE WITH #4's @ 12" O.C.E.W. VEL BACKFILL 12" TALL x 24' WIDE x 47-4" LONG DEADMAN w (2) #6's CONTINUOUS & STIRRUPS EVERY 7-0" I cIlTY.PCIAL SECTION VIEW 11 SCALE: 1" = 10' 301000 GALLON TANK 141-91 CITY COPY 12" TALL-x 12" WIDE x 47-4" LONG DEADMAN w/ (4) #4's CONTINUOUS & STIRRUPS EVERY 7'-011 [ TYP. BOTH SIDES ] IF THE APPROVED PLANS ARE MODIFIED, A NEW SUBMITTAL TO THE CITY IS REQUIRED PRIOR TO THE CHANGE OCCURING 8" CONCRETE WITH #4's @ 12" O.C.E.W. 1 b 11 TYPICAL PROFILE VIEW_ 11 SCALE: 1 !1= 10' Kml 1 !-IL I VI\ i .JLI 1 L1LL/ I IL. L-1\../ ► 7 1 ,, .i I IN"I J PROVIDED BY TANK MANUFACTURER (8 TOTAL PIER TANK) VA Q 9 27 e CISNEROS DESIGN GROUP 2501 W 11 th St HOUSTON, TX 77008 OFFICE: 713. 524. 2880 eMAIL: cisn'�e' r�+os /� cis-axis.conl SEAL: N qt= -0 a 0 x �c Z ° UA >0 VJ v 1 rl a h N c 0 Z x x x w 0 0 o d w r Q of N ci i t < N 0 0 w 0 o V� IL t" REVISIONS & DATE X DRAWN BY: GERARDO DATE: 01/1'1 /2017 SCALE: < NOTED > SHEET NO: FP1 ..-.-.�.-...r---T-�.-.r•--�-rrr-r:��c..rr-*r--�'r--r-^..ra*+.rr..n-rr•,t'r7'��?T1�.r.c-r!!?*?rr'^,-�'^--n-s,,..w�-� -- SCOPE OF WORK -- UST CONTRACTOR SHALL: • PERFORM TEXAS COMMISSION ON ENVIRONMENT QUALITY 30-DAY NOTIFICATION AND AQUIRE ALL LOCAL FIRE DEPARTMENT PERMITS. PROVIDE SAFETY DEVICES TO CORDON OFF AREA OF CONSTRUCTION. « EXCAVATE NEW TANK HOLE TO ACCOMMODATE NEW UNDERGROUND FUEL TANKS AND TRENCH FOR PIPING. SPOILS TO BE HAULED TO APPROVED LOCATION. • PROVIDE AND INSTALL (1) 30,000 GALLON FUEL TANK (SPLIT (1) 20,000 GALLON UNLOADED, 5,000 GALLON DIESEL & 5,000 GALLON PREMIUM). UNDERGROUND STORAGE TANKS MANUFACTURED BY MODERN WELDING COMPANY WITH 30-YEAR WARRANTY. TANKS TO BE UNLOADED WITH HYDRAULIC CRANE. « PROVIDE AND INSTALL DEAD MAN TANK ANCHORING SYSTEM INCLUDING FACTORY SUPPLIED STRAPS, CONCRETE ANCHOR BEAMS, TURNBUCKLES, CABLE, AND CLAMPS. PROVIDE AND INSTALL (2) LOCKABLE MONITOR WELLS FOR MANUAL LEAK DETENTION. • PROVIDE AND INSTALL (4) F.E. PETRO SUBMERSIBLE PUMPS AND CONTROL BOXES, (1) 2 HP. FOR AUTO DIESEL, (1) 2 HP. VARIABLE SPEED FOR UNLEADED, (1) 2 HP. VARIABLE SPEED FOR SUPER UNLEADED GASOLINE. (VERIFY WITH OWNER). « PROVIDE AND INSTALL FIBERGLASS CONTAINMENT SUMPS FOR SUBMERSIBLE CONTAINMENT (AS REQ.) PROVIDE AND INSTALL 38" COMPOSITE TOP MANHOLES FOR ACCESS TO TURBINES (AS REQ.) • PROVIDE AND INSTALL OVERSPILL CONTAINMENT WITH DRAIN VALVES ON (3) UNDERGROUND TANK FILL PORTS. • PROVIDE AND INSTALL (3) PRODUCT IDENTIFICATION TAGS. • PROVIDE AND INSTALL (3) 4" STEEL RISERS, ROTATABLE FILL ADAPTERS, LOCKABLE CAPS AND ALUMINUM DROP TUBES. • PROVIDE AND INSTALL (3) 4" STEEL RISERS, EXTRACTOR TE'S, AND 2" X 16" BALL FLOATS FOR OVERFILL PROTECTION. « PROVIDE AND INSTALL (2) ROTATABLE VAPOR ADAPTERS, AND LOCKABLE CAPS FOR STAGE 1 VAPOR RECOVERY AND INSTALL (2) 12" MANHOLES FOR ACCESS TO VAPOR ADAPTERS. • PROVIDE AND INSTALL (1) 4" STEEL RISER, CAP, AND 12" MANHOLE FOR ACCESS FOR FUTURE STAGE 1 VAPOR RECOVERY ON THE DIESEL TANK. * PROVIDE AND INSTALL (3) 4" STEEL RISERS, AND 18" MANWAYS FOR INVENTORY CONTROL SYSTEM. • PROVIDE AND INSTALL (4) 36" FIBERGLASS DISPENSER CONTAINMENT SUMPS WITH PENETRATION FITTINGS. • PROVIDE AND INSTALL (6) 1-1/2" DOUBLE POPPET SHEAR VALVES FOR PRODUCT PIPE TO DISPENSER CONNECTION. • PROVIDE AND INSTALL 3" FIBERGLASS PIPE FOR STAGE 2 VAPOR RECOVERY FROM DISPENSERS TO UNLEADED TANKS. PROVIDE AND INSTALL (1) PRESSURE/VACUUM VENT CAP FOR GASOLINE AND (1) UP FLOW VENT -CAP FOR DIESEL. • PROVIDE AND INSTALL 3" FIBERGLASS PIPE FOR GASOLINE TANK VENT LINE. INSTALL VENT RISER AND RACK. « PROVIDE AND INSTALL (2) 2" x 24" STAINLESS STEEL FLEX CONNECTORS FOR VENT LINE CONNECTION. « PROVIDE AND INSTALL 2" FIBERGLASS PRODUCT INSIDE 3" FIBERGLASS CONTAINMENT PIPE FOR DOUBLE WALL PRODUCT PIPE SYSTEM • PERFORM AIR TEST ON PRODUCT PIPING TO STATE AND LOCAL CODE PRIOR TO BACKFILLING • BACKFILL NEW TANK EXCAVATION AND PIPING TRENCHES WITH PEAGRAVEL AS REQUIRED. • PROVIDE AND INSTALL b" DIAMETER BOLLARDS AT ALL DISPENSERS FOR TRAFFIC PROTECTION (REFER TO SHEET 'SP1' FOR BOLLARD LOCATIONS). • UNLOAD AND INSTALL (2) OWNER SUPPLIED "GILBARCO" 3+1 DISPENSERS AND (2) OWNER SUPPLIED "GILBARCO" 3+0 DISPENSERS AND HANGING HARDWARE (INCLUDING NOZZLES, HOSES, SWIVELS AND BREAKAWAYS). « START UP OF SYSTEM AND TRAINING BY AUTHORIZED DEALER AND "GILBARCO". (COORDINATED BY FUEL INSTALLER) . • PROVIDE AND INSTALL (1) VEEDER ROOT TLS 450 AUTOMATIC TANK MONITORING SYSTEM WITH (3) INVENTORY PROBES, CAP AND RING KITS, (5) PLLD KITS AND REQUIRED CABLE INCLUDING SYSTEM START UP. PROVIDE PRODUCT RECONCILIATION MODULE. • PRECISION TEST TO BE PERFORMED BY QUALIFIED THIRD PARTY TESTER ON (3) NEW UNDERGROUND STORAGE TANKS AND PRODUCT LINES. PRESENT OWNER WITH REPORT. • PERFORM STATE REQUIRED VAPOR RECOVERY COMPLIANCE TEST AND PROVIDE OWNER WITH REPORT. • BUSINESS INVENTORY RECONCILIATION (BIR). CONDITIONS i E ALL WORK WILL BE PERFORMED PER OSHA CITY REQUIREMENTS. Co Rkw ALL WORK WILL BE PERFORMED TO LOCAL, STATE A FEDERAL REQUIREMENTS. LAYOUT AND DESIGN OF PROJECT SHALL BE IF`4 :�; PLANs CONFIRMS PRIOR TO CONSTRUCTION BY fr D, w sug�l Y IS R QUIRED PR CONTRACTOR. CHANGE OCCURINe OWNER TO SUPPLY DISPENSERS, AND HANGING HARDWARE. � ...tea. `'ai..ass `� yi�4' �Gi-"� -'I►'� FEB 0 9 2017 CISNEROS DESIGN GROUP 2501 W 11 th S# HOUSTONv TX 77008 OFFICE: 7l3. 524. 2880 eMAIL: cisneros r cis-ams.com SEAL: r ai W c _Q v >m W o CD I N a0 LL- UJ 4 z 0. N 0 Z x � � K W mi C° � UJ a go Q Ee cn 0 W C 0 Tw a REVISIONS & DATE x DRAWN 8Y: GERARDO DATE: 01 /11120/7 SCALE: c NOTED > SHEET NO: L FP2 I DEC 2 7 2017 u 0 kOS Ik iioo FS SECTION SHOWING SINGLE SUPPLY LINE "ELBOW" FITTING NOT TO SCALE SUMBER.SIBLE PUMP VALVE NOT TO SCALE TOP OF ISLAND ENTRY BOOT DISPENSER SUMP WALL t nM ^-I Mi ILI^ I STAGE II VAPOR RETURN DETAIL 4 I NOT TO SCALE 7IgPENSER =T" OR ELBOW AS NECESSARY NOTES: z 0 �— APPROVED BACKFILL REFER TO NOTE SECTION 1.) SEE SHEET "SP2" FOR LOCATION ' 2.) PROVIDE 3" (MIN.) STEEL BOLLARDS IF VENTS ARE LOCATED INSIDE FUE CANOPY COLUMNS ow VENT STACK SECTION V" 1 NOT TO SCALE APPROVED VALVES: ,— / „ l QLBARCO NO.PA0092-0001 33` FLAT LID K____ _ ..___ _ �__` _ _ .— j EMCODPWNWHEATON NO.A-0025 LS0033 s UNIVERSAL 521 SUMP BASE AND RISER. AS SPECIFIED NOT TO SCALE UMP �33 RISER SUMP BASE US0042 ISLAND DISPENSER BASE) SHEAR GROOVE MUST BE FLUSH W/T.O.ISLAND TO-3/4 FOR MPD'S. * 3/4-TO TOP OF ISLAND FOR ALL OTHERS. TYP. SHEAR VALVE DETAIL, — DOUBLE POPPETT SHEAR. VALVES NOT TO SCALE r E s f OVER PLANS A NEW SUBMIM REQUIRED PRIO NGE OCCURING Q EXe1)tions CISNEROS DESIGN GROUP 2501 W 11th�Svt HOUSTON, ■ A 77008 OFFICE: 713. 524, 2880 eMAIL; o-- clsneros a@ cis-axis.com SEAL: 3 i vi 0 x■ .6 4.4 •O co >' to j CL �i n LUp 00 L c 0 X x w 0 O D a- 'I ■ oco < o O 0 0 a r !Z REVISIONS & DATE DRAWN BY: GERARDO DATE: 01 /11 /2017 SCALE: NOTED SHEET NO: FP3- DEC 2 7 2017 r h 3"w FIBERGL"cC D1OC VENT LINE T STACK LOCH SITE PLAN F LOCATION SL FOOT TOWAR EXTRACTOR ASSEMBLY DETAIL NOT TO SCALE PIPING NOTES LEI VAPOR RETURN DISPENSERS JKFOOT , u,,,..,. l ...,, tT ALL BACKFILL TO BE COMPACTED TO 95% S.P.D. BACKFILL AND BEDDING MATERIAL TO BE: CLEAN SAND: 6" (MINIMUM) OF CLEAN SAND ON ALL. SIDES, BOTTOM AND TOP OF TANK. GRAVEL: ROUNDED PEA GRAVEL WITH A MINIMUM DIAMETER OF 1/4" AND A MAXIMUM DIAMETER OF 1/2". STONE CRUSHINGS: WASHED AND FREE FLOWING WITH ANGULAR PRACTICE SIZE BETWEEN 1/8" AND 1/2" AND MEET ASTM C--33 PARAGRAF 9.1 NOTE: NO MORE THAN 3% OF BACKFILL MATERIAL SHALL PASS THROUGH A #8 SIEVE. [-BILINE TESTING GENERAL CONTRACTOR TO COMPLETE THE "INSTALLATION CHECKLIST" INCLUDED IN THE SPECIFICATIONS AND SUBMIT THE INFORMATION REQUESTED TO THE OWNER. POST INSTALLATION TESTING: ISOLATE LINES FROM UNDERGROUND STORAGE TANKS. PRESSURIZE LINES TO A MINIMUM OF 25 P.S,I. FOR A PERIOD LONG ENOUGH TO DETERMINE THAT THERE ARE NO LEAKS AS INDICATED BY SOAP BUBBLES OR A DROP IN THE PRESSURE OF THE LINE. DURING SITE WORK TESTING: MAINTAIN A LINE PRESSURE OF 10 PSI IN THE PIPE DURING CONSTRUCTION OF THE REST OF THE FACILITY TO MONITOR THE INTEGRITY OF THE PIPNG. CHECK GAUGES AT REGULAR INTERVALS. POST -SITE WORK INSTALLATION TESTING: GENERAL CONTRACTOR TO HAVE A TESTING LABORATORY PERFORM A PRECISION LINE TEST AFTER ALL PAVING AND SITE WORK HAS BEEN DONE. VENT STACK.. SECTION NOT TO SCALE ,K STEEL RISER PIPE 4"0 NIPPLE 1 1/2" MIN. 4" 0 FILL ADAPTER 2" MAX. AND LOCKING CAP 6" SPILL CONTAINER WEEP HOLE I IN DROP TUBE L J 4" ALUMINUM DROP TUBE 10. 7�, ELEC. JUNCTION BOX (EXPLOSION PROOF) 4" 0 STEEL RISER, CORROSION PROTECTED.. RIGID CONDUIT TANK z N TANK LEVEL MONITOR MANHOLE t, A 4, 4 c0 ' UNDERGROUND FUEL TANK DISPENSER SUMP PLAN AUTOMATIC TANK GAUGE ATG 1011 NOT TO SCALE ll&FNOTTO SCALE j VAPOR R.ECOVER.Y DETAIL T NOT TO SCALE CROUSE-HINDS 3 SERIES CONNECTd 3" BULKHEAD W/S.S. CLAMPS (1 WA MONITOR WELL 1311 NOT TO SCALE PIPE 'CAP 4"0 STEEL RISER, CORROSION SEAL OFF 3/4" RGC 4" PVC EPA. INSPECTION WELL WITH PERFORATED SECTION TO BOTTOM OF TANK. 3/4" ROCK 48" HIGH MIN. AROUND BURP TUBE 9 SET BOTTOM 12" BELOW TANK LOWEST LEVEL E .43 .S I +sr- APPROVED PLANS' ARE MODIFIED, A NEW SUBMITT TO THE CITY IS REQUIRED PI;; TO THE '"vIOE OCCURIN 1G SUMP SEAL LOW VOLTAGE MONITORING JUNCTION BOX Q ELECTRICAL CONDUIT FOR SUB -PUMP HIGH VOLTAGE 220 (EXPLOSION PROOF) ELECTRICAL SEAL -OFF BASE AS SPECIFIED PLACE GRAVEL BACKFILL {>I 201 SUMP 4 /1 4 I\ - Sl L!'1Vf\ LLaI.lV i, 1 1 , 1111— 4 [j PLAN - - SECTION THRU SUMP SHOWING SUBMERGED TURBINE PUMP INSTALLATION NOT TO SCALE �141 NOT TO SCALE CISNEROS DESIGN GROU 2501 'VIA° 1 l th St HOUSTON, TX 77008 OFFICE: 7 13. 524, 2880 eMAIL: Cisneros Cis-axis.com SEAL: Z Wb 0r. o 99 IL N U 0 uj 0 U1 0 a C� I 00 C O x x LJ .0 O . 0. r i r i W 0 a a N < VJ O REVISIONS & DATE DRAWN BY: GERARDO ATE: 01 /11 /2017 SCALE: NOTED SHEET NO: FP4 DEC 2 7 2017 ISM ILSLL Xl `alaod el IS Aempeoa8 S ZOit _ LZ xo9 SOS-dV c* _ AP-505 Box 27 1101 S Broadway St La Porte, TX 77571