1112 W MAIN ST 200_20-2355_20-2355__________
1112 W MAIN ST 1112 W MAIN ST COMM REMODEL 20 2355 11 .,A - �l - CLIH 13 O� q ° City of La Porte Fire Marshal's O{�'ce U Esfa6lisked 1892 Cli( Meekins, Fire Marshal vrr.iry Date of Inspection: 7/20/21 Business Information: Business Name: ITitlemax Address: 11112WMain#200 Contact person: ITed Knaack Phone Number: 1214.202.5192 Inspection Information: Inspection Type: IFinal FMOInspector: lGalindo Inspection Disposition: Z Passed l Cleared for Power ❑ Failed ❑ TCO — -- - -- - — -- i i Notes: PREPARED 7/19/21, 12:14:37 INSPECTION TICKET PAGE 1 CITY OF LA PORTE INSPECTOR: INSPECTOR DATE 7/20/21 ------------------------------------------------------------------------------------------------ ADDRESS : 1112 W MAIN ST 200 SUBDIV: LA PORTE CONTRACTOR JEPM ELECTRIC LLC PHONE OWNER PIRZADEH HADI PHONE PARCEL 023-183-050-0007 APPL NUMBER: 20-00002355 REMODEL, COMMERCIAL -------------------------------------------------------------------------------------------- PERMIT: CR 00 BLDG PERMIT -COMMERCIAL REMODEL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ----------------------------------------------------------------y----------/-�-----------/-y--- BLFI O1 20/21 7/� IN FINAL, BUILDING TIME: 07/19/21 @ 11:32am 08:00 Santos 219-459-9679 ✓ U J ----------=----------- -- ----Final- COMMENTS AND NOTES-------------------------------------- p (< _ 0 [` CG 69 S J bJ. C, -� --C) 'F v"k, O 0 �< �_a c� o se Withers, Jennifer From: Sent: To: Cc: Subject: CITY FINAL 07/20/21 AM INSP CONTACT SANTOS 214-454-9674 ADDRESS 1112 W MAIN 5T#200 Thanks! Withers, Jennifer Monday, July 19, 2021 11:51 AM Manuel, Sandra Meekins, Clif; Tschappatt, Vickie; Dawson, Jaycee final 20-2355 1112 W MAIN ST Jennifer Withers Inspections Dept. 604 W. Fairmont Parkway I La Porte, TX 77571 P. 281-470-5073 F. 281-470-5005 The City of La Porte recently approved the 2018 Building Code editions and the 2020 National Electrical Code to be effective November 28, 2020 City of La Porte 604 W Fairmont Pkwy La Porte, Tx 77571 Inspection Request Line: 281-470-5130 ****BUILDING PERMIT**** -------------------------------------------------------------------------- Application Number . . . . . 20-00002355 Date 5/18/21 Property Address . . . . . . 1112 W MAIN ST 200 HCAD Number: 023-183-050-0007 Alternate Search Method: Application type description REMODEL, COMMERCIAL Subdivision Name . . . . . . LA PORTE Property Use . . . . . . . . Property Zoning . . . . . . . NOT YET IDENTIFIED Application valuation . . . . 116505 -------------------------------------------------------------------------- Type of Work INTER ALTER FOR NEW TENANT LAYOUT Owner Contractor PIRZADEH HADI OWNER ZAMANI BEHROUS Ill N 10TH ST LA PORTE TX 775713101 Structure Intormation 000 000 Construction Type . . . . . NON-COMBUSTIBLE II Occupancy Type . . . . . . BUSINESS Other struct info . . . . . FLOOD ZONE ae --------------------------------------------------------------------------- Permit . . . . . . BLDG PERMIT -COMMERCIAL REMODEL Additional desc . . INTERIOR REMODEL Permit pin number . 657742 Permit Fee . . . . 764.00 Plan Check Fee 382.0( Issue Date . . . . 5/18/21 Valuation . . . . 11650! Expiration Date . . 11/14/21 Qty Unit Charge Per Extensioi BASE FEE 687.51 17.00 4.5000 THOU BLDG - 100,001 - 500,000 76.5( -------'------------------------------------------------------------------- Special Notes and Comments January 11, 2021 9:56:07 AM LAPOJLW. COMMERCIAL PERMIT NOTES 1. ALL NEW DEVELOPMENT MUST OBTAIN A WATER ACCOUNT THROUGH THE CITY OF LA PORTE WATER DEPARTMENT ® 281-470-5020 PRIOR TO BUILDING PERMIT ISSUANCE. 2. ALL WORK MUST COMPLY WITH THE APPROVED PLANS, INSPECTIONS. 3. CONTRACTOR MUST COMPLY WITH ATTACHED FIRE MARSHAL PLAN REVIEW COMMENTS IF City of La Porte 604 W Fairmont Pkwy La Porte, Tx 77571 Inspection Request Line: 281-470-5130 ****BUILDING PERMIT**** -------------------------------------------------------------------------- Page 2 Application Number . . . . . 20-00002355 Date 5/18/21 -------------------------------------------------------------------------- Special Notes and Comments APPLICABLE. 4. OWNER/CONTRACTOR RESPONSIBLE TO COMPLY WITH TEXAS ACCESSIBILITY STANDARDS (TAS) AS REQUIRED. 5. THIS BUILDING PERMIT APPROVED SUBJECT TO CITY APPROVED CONSTRUCTION DRAWINGS WITH RED LINES, PLAN REVIEW COMMENTS & CERTIFIED SITE PLAN & INSPECTIONS. 6. IF ANY FILL DIRT IS BROUGHT ONTO THE SITE OTHER THAN INSIDE THE BUILDING FOOTPRINT, A SEPARATE FILL DIRT PERMIT IS REQUIRED. 7. ANY FUTURE REMODEL OR BUILDOUT OF OFFICE SPACE REQUIRES SEPARATE PERMITS AND INSPECTIONS. 8. SEPARATE ELECTRICAL, PLUMBING & MECHANICAL PERMITS REQUIRED FOR ANY RELATED WORK. 9. ANY NEW OR PROPOSED SIGNAGE REQUIRES A SEPARATE SIGN PERMIT BEFORE INSTALLING ANY SIGNAGE. 10. CALL FOR INSPECTIONS BEFORE ANY WORK IS COVERED. 11. FINAL ENERGY CODE CERTIFICATE OF COMPLIANCE REQUIRED FROM ICC CERTIFIED 3RD PARTY ENERGY CODE INSPECTOR BEFORE BUILDING FINAL INSPECTION IF APPLICABLE. 12. ANY CHANGES TO THE APPROVED SET OF PLANS OR APPROVED SCOPE OF WORK MUST BE APPROVED BY THE INSPECTIONS DIVISION PRIOR TO COMMENCING CHANGES IN THE FIELD. 13. SMOKE DETECTORS REQUIRED TO BE INSTALLED AS PER THE 2011 NEC HARDWIRED AND INTERCONNECTED IF APPLICABLE. 14. GFCI RECEPTACLES REQUIRED TO COMPLY WITH THE 2011 15. ALL AREAS INTENDED TO BE UTILIZED FOR PARKING SPACE AND DRIVEWAYS SHALL BE SURFACED WITH MATERIALS SUITABLE TO CONTROL DUST AND DRAINAGE. 16. CHECK APPLICABLE DEED RESTRICTIONS AND HOME OWNER ASSOCIATIONS FOR ANY OTHER POSSIBLE REQUIREMENTS OR REQUTARED APPROVAL. City of La Porte 604 W Fairmont Pkwy La Porte, Tx 77571 Inspection Request Line: 281-470-5130 ""BUILDING PERMIT**** Page 3 Application Number . . . . . 20-00002355 Date 5/18/21 -------------------------------------------------------------------------- Special Notes and Comments 17. MINIMUM SIX-INCH (6 ) STUD WALLS SHALL BE REQUIRED WHERE DRAIN, WASTE, AND VENT PLUMBING IS INSTALLED. 18. ALUMINUM CONDUCTORS MAY BE USED IN COMMERCIAL APPLICATIONS AS FOLLOWS: OUTSIDE AERIAL CONDUCTORS, AND SERVICE ENTRANCE CONDUCTORS. -------------------------------------------------------------------------- Fee summary Charged ----------------- Paid Credited Due ---------- ---------- Permit Fee Total 764.00 764.00 ---------- .00 ---------- .00 Plan Check Total 382.00 382.00 .00 .00 Grand Total 1146.00 1146.00 .00 .00 (APPROVED BY BUILDING OFFICIAL OR AUTHORIZED AGENT) City of La Porte Planning 8 Development Phone: 281.470.5073 604 W. Fairmont Pkwy BUILDING PERMIT APPLICATION Fax: 281.470.5005 La Porte TX 77571 permits@laportetx.gov Applicant Name: Project Address: Site Plan No. if applicable: lid * /AqAe-k ///L W MA1i 15? HCAD Parcel No. (1(2) (3) I FC3AI nFSCRIPTinN-- Phone: -4MAR,w�4A.1 t,IAr -75/09/ Contact Person: aoo YOUR PROPERTY INSUREDS n YES I -I NO / Business) Project Name: SELECT ALL THAT APPLY: u'RESIDENTIAL COMMERCIAL VALUATION REQUIRED $1� 'DOES NOT REOUIRE VALUATION ❑ NEV11 ❑ ADDITION 16 REMODEL ❑ CULVERTS ❑ FOUNDATION ❑ IRRIGATION ❑ SIGN ❑ OTHER ❑ FENCE ❑ POOL DRIVEWAY DESCRIBE WORK: APPLICATION CHECKLIST & SUPPORTING DOCUMENTATION: RESIDENTIAL PROJECT: COMPLETE BUILDING PERMIT APPLICATION AND (2) COMPLETE SET OF CONSTRUCTION PLANS OR TO SCALE DRAWINGS COMMERCIAL PROJECT: HARD COPIES: COMPLETE BUILDING PERMIT APPLICATION, (2) 24 X 36 COMPLETE PLAN SET, AND SITE PLAN USB MUST INCLUDE THE FOLLOW NG IN PDF FORMAT: COMPLETE BUILDING PERMIT APPLICATION, COMPLETE PLAN SET IN A SINGLE FILE, AND SITE PLAN. (PLEASE DO NOT SUBMIT CD IN LIEU OF USE) NOTE: SITE PLAN FEE WE AT TIME OF SUBMITTAL MAJOR SITE PLAN 10 ACRES OR GREATER. $368.a6-$5.00 PER ADDITIONAL ACRE: MINORS/TE PLAN LESS THAN 10 ACRES: f20 W- SSW PER ADDITIONAL ACRE. CONTRACTOR REQUIREMENTS: CURRENT GENERAL LIABILITY CERTIFICATE OF INSURANCE MINIMUM OF $100.000. CITY OF LA PORTE:604 W. FAIRMONT PKWY; LA PORTE, TX 77571 AS THE CERTIFICATE HOLDER. NOTE: NOT A VALID PERMIT UNTIL OWNER/ CONTRACTOR IS NOTIFIED OF APPROVAL AND ALL APPLICABLE FEES ARE PAID IN FULL. AS A CONDITION SIGNATURE OF A STAFF USE ONLY: OF THE CITY OF LA PORTE TO ACCESS MY PROPERTY FOR THE PURPOSE OF IN THIS APPLICATION & THE PLANS SUBMITTED THEREWITH. PRINTED NAME: DATE: 7- / 9 — 2/ TAXES: CODE ENFORCEM T: FLOOD ZONE: TYPE OF CONSTRUCTION: TYPE OF OCCUPANCY: USE ZONE: BASEPERMITFEE PERMITFEE F REVIEWFEE I DWYE.WY TIEIN FEE PNLMLW) 6 EONE FEE oTNEa FEE NEW WATER ACCOUNT SET-UP REQUIRED FOR THIS PROJECT: YES NO PERMIT APPLICATION RECEIVED BY: UA I E: PREPARED 7/16/21, 13:22:29 INSPECTION TICKET PAGE 1 CITY OF LA PORTE INSPECTOR: INSPECTOR DATE 7/19/21 ------------------------------------------------------------------------------------------------ ADDRESS : 1112 W MAIN ST 200 SUBDIV: LA PORTE CONTRACTOR JEPM ELECTRIC LLC PHONE OWNER PIRZADEH HADI PHONE PARCEL 023-183-050-0007 APPL NUMBER: 20-00002355 REMODEL, COMMERCIAL ------------------------------------------------------------------------------------------------ PERMIT: PL 00 BLDG PERMIT PLUMBING SUB: S PALMERO PLUMBING REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ PLFI O1 7/19/21 IN FINAL, PLUMBING TIME: 08:00 7/16/2021, 12:42:14 PM LAPOHXP ----JUAN 713-702-0938 ----- - PLUMBING FINAL ------- -- V COMMENTS AND NOTES ------------------ -------------- a PREPARED 7/ 141 21, 16: 59: 42 INSPECTION TICKET PAGE 3 CITY OF LA PORTE INSPECTOR: INSPECTOR DATE 7/15/21 ________________________________________________________________________________________________ ADDRESS . 1112 W MAI N ST 200 SUBDI V: LA PORTE CONTRACTOR JEPM ELECTRIC LLC PHONE OMER PI RZADEH HADI PHONE PARCEL 023-183-050-0007 APPL NUMBER: 20-00002355 REMODEL, COMMERCIAL ________________________________________________________________________________________________ PERMI T: EL 00 BLDG PERMIT ELECTRICAL- COMM REQUESTED I NSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS EL FI 02 1- - _I N_ _n FINAL, ELECTRICAL TI ME: 17: 00 _ ALEJANDRA @ 214. 717. 3931 ELEC. FINAL 7/14/2021, 4:49:58 PM LAPOJLD PERIA T: M1 00 BLDG PERMIT MECHANICAL SUB: MOUNTAIN TOP HVAC- R LLC REQUESTED I NSP DESCRIPTION TYP/SO COMPLETED RESULT RESULTS/COMMENTS ________________________________________________________________________________________________ MI FI 01 _ 21 -1 Nap FINAL, MECHANICAL TI ME: 08: 00 I VAN ® 254. 434. 1695 MECH FINAL 7/14/2021. 4: 20: 19 PM LAPOJLD ______________________________________ COMMENTS AND NOTES -------------------------------------- PREPARED 7/ 13/ 21, 7: 08: 38 INSPECTION TICKET PAGE 1 CITY OF LA PORTE INSPECTOR: INSPECTOR DATE 7/13/21 ------------------------------------------------------------------------------------------------ ADDRESS : 1112 W MAIN ST 200 SUBDI V: LA PORTE CONTRACTOR JEPM ELECTRIC LLC PHONE OMER PI RZADEH HADI PHONE PARCEL 023-183-050-0007 APPL NUMBER: 20-00002355 REMODEL, COMMERCIAL ------------------------------------------------------------------------------------------------ PERMI T: EL 00 BLDG PERMIT ELECTRICAL- COMM REQUESTED I NSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ ELFI O1 7/e-21 IN FINAL, ELECTRICAL TIME: 17: 00 _______ 214. 717. 3931 ELEC. FINAL -e u I �� 7/1312021, 7: 06: 41 AM LAPOJLD -------------------------- --------- COMMENTS AND NOTES-------------------------------------- REPARED 7/ 06/ 21 7: 10: 18 INSPECTION TICKET PAGE 4 ITY OF . LA PORTE INSPECTOR: INSPECTOR DATE 7I06/21 ____ ______________________________ _____ __________________________ DDRESS : 1112 W MAIN S 200 SUBDI V: LA PORTE ONTRACTOR JEPM ELECTRIC PHONE ,WJER PI RZADEH HADI PHONE ARCEL 023-183-050-0007 PPL NUMBER: 20-00002355 REMODEL, COMMERCIAL _______________________________________________________________________________________________ -ERMI T: EL 00 BLDG PERMI T ELECTRICAL- COMM REQUESTED I NSP DESCRIPTION YP/SQ COMPLETED RESULT RESULTSICOMMENTS ______ ______________________________________________________________________---- :LI N 04 7/ 06121 IN ELEC, ELECTRICAL SERVICE TIME: 17: 00 214.717.3931 ELEC. 1 7/6/2021, 7: 07: OS AM LAPOJLD --------- __________------------------ COMMENTS AND NOTES ______________________________________ Z� © f l (2 w malt', s , PREPARED 6/ 29/ 21. 11: 25: 51 I NSPECTI ON TICKET PAGE 5 CITY OF LA PORTE INSPECTOR: INSPECTOR DATE 6/30/21 ----------------------------------------------------------------------------- ADDRESS : 1112 W MAIN ST 200 SUBDI V: LA PORTE CONTRACTOR JEPM ELECTRIC LLC PHONE ONNER PI RZADEH HADI PHONE PARCEL 023-183-050-0007 APPL NUMBER: 20-00002355 REMODEL. COMMERCIAL ----------------------------------------------------------------------------- PERMI T: M1 00 BLDG PERM! T MECHANICAL SUB: MOUNTAIN TOP HVAC- R LLC REQUESTED I NSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ MI CU 01 6/ 30/ 21 IN MECH, COVER UP - SINGLE TRADE TIME: 08: 00 06-29-21 @ 9;55am IVAN 254-434-1695 MECH ROUGH ---� - COMMENTS AND NOTES-------------------------------------- PREPARED 6/ 29/ 21, 7: 10: 19 1 NSPECTI ON TI CKET PAGE 2 CITY OF LA PORTE INSPECTOR: INSPECTOR DATE 6129121 ................................................................................................ ADDRESS 1112 W MAIN ST 200 SUBDI V: LA PORTE CONTRACTOR JEPM ELECTRIC LLC PHONE OMER PI RZADEH HADI PHONE PARCEL 023-183-050-0007 APPL NUMBER: 20-00002355 REMODEL, COMMERCIAL ________________________________________________________________________________________________ PERMI T: Mt 00 BLDG PERMIT MECHANICAL SUB: MOUNTAIN TOP HVAC- R LLC REQUESTED 1 NSP DESCRI PTI ON TYP/SQ COMPLETED RESULT RESULTS/COMMENTS MEI N 01 61 29/ 21 1 MECH, INSPECTION ON TiME: 17: 00 I I VAN ® 254. 434. 1695 -- __ __ ___ (`J1 vt MECH I NSPEC. G� 6/28/2021. 4: 27: 14 PM LAPOJLD ...................................... COMMENTS AND NOTES -------------------------------------- PREPARED 6/ 281 21, 15: 08: 32 INSPECTION TICKET PAGE 3 CITY OF LA PORTE INSPECTOR: INSPECTOR DATE 6/29/21 ________________________________________________________________________________________________ ADDRESS : 1112 W MAIN ST 200 SUBDI V: LA PORTE CONTRACTOR JEPM ELECTRIC LLC PHONE OVWER PI RZADEH HADI PHONE PARCEL 023-183-050-0007 APPL NUMBER: 20-00002355 REMODEL, COMMERCIAL ________________________________________________________________________________________________ PERMI T: CR 00 BLDG PERMI T- COMMERCI AL REMODEL REQUESTED I NSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ----- ------ ------- ________ _____________-_________________________--------------------------- PRCO 01 _-61 29/ 21- IN - BLDG, PRE- POUR CONCRETE TI ME: 08: 00 214. 232. 6960 CONCRETE ROUGH IN? C/ A. M I NSPEC. 6/2812021. 3:02:22 PM LAPOJLD ______________________________________ COMMENTS AND NOTES ______________________________________ PREPARED 6/ 241 21, 15: 31: 36 INSPECTION TICKET PAGE 6 CITY OF LA PORTE INSPECTOR: INSPECTOR DATE 6/25/21 ---------------------- ADDRESS __________________________________________________________________________ . 1112 W MAI N ST 200 SUBDI V: LA PORTE CONTRACTOR JEPM ELECTRIC LLC PHONE OWNER PI RZADEH HADI PHONE PARCEL 023-183-050-0007 APPL NUMBER: 20-00002355 REMODEL, COMMERCIAL ________________________________________________________________________________________________ PERMA T: CR 00 BLDG PERMI T- COMMERCIAL REMODEL REQUESTED I NSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ---- _______ ------- _____ ______----- _---- __---------- ___----- __________________________________ FRAM 03 6I 25/ 21 I BLDG, FRAME INSPECTION TI ME: 17: 00 SANTOS ® 214.454.9674 FRAMING G / 6/24/2021__ 3_21:0PMLAPOJLD PERMI T: PL 00 BLDG - ------- PERMI T PLUMBI NG SUB: S PALMERO PLUMBI NG �1 REQUESTED I NSP DESCRIPTION TYPISQ COMPLETED RESULT RESULTS/COMMENTS GRPL 01 6/ 25/ 21 I N PLBG, PLUMBING, GROUND TI ME: 17: 00 713. 702. 7938 'I 'l PLBG GROUND AND ROUGH I NSPEC. 6/2412021, 3: 20: 20 PM LAPOJLD ______________________________________ COMMENTS AND NOTES ______________________________________ t-ve'- I/ PREPARED 6/ 23/ 21, 16: 05: 02 INSPECTION TICKET PAGE 10 CITY OF LA PORTE INSPECTOR: INSPECTOR DATE 6/24/21 ------------------------------------------------------------------------------__.--------------- ADDRESS . 1112 W MAIN ST 200 SUBDI V: LA PORTE CONTRACTOR JEPM ELECTRIC LLC PHONE OWJER PI RZADEH HADI PHONE PARCEL 023-183-050-0007 APPL NUMBER: 20-00002355 REMODEL, COMMERCIAL ___________________________________________________ _---_____-_---_-_________-_-_--------- PERM! T: CR 00 BLDG PERMI T- COMMERCI AL REMODEL REQUESTED I NSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ FRAM 02 6/ 24/ 21 IN BF 4 DG, R FAME INSPECTION TI ME: 17: 00 9674 ( ,eA4. 54. A 1 ((((////FRAMING I NSPEC. 6/23/2021. 9:20:41 AM LAPOJLD -------------------------------------- COMMENTS AND NOTES -------------------------------------- PREPARED 6/23/21, 9:43:30 INSPECTION TICKET PAGE 1 CITY OF LA PORTE INSPECTOR: INSPECTOR DATE 6/24/21 ------------------------------------------------------------------------------------------------ ADDRESS : 1112 W MAIN ST 200 SUBDIV: LA PORTE CONTRACTOR JEPM ELECTRIC LLC PHONE OWNER PIRZADEH HADI PHONE PARCEL 023-183-050-0007 APPL NUMBER: 20-00002355 REMODEL, COMMERCIAL ------------------------------------------------------------------------------------------------ PERMIT: CR 00 BLDG PERMIT -COMMERCIAL REMODEL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS --------------------------------------------------------------_------------_____-_______ FRAM 02 6/24/21 IN BLDG, FRAME INSPECTION TIME: 17:00 214.454.9674 _ FRAMING INSPEC. _/ 6/23/2021, 9:20:41 AM LAPOJLD ---------------------- 0 _---_-----_ COMMENTS AND NOTES -------------------------------------- YYY cv#l-[V-G' -/ ' City of La Port e 604 W Fai r mont Pkwy La Porte, Tx 77571 I nspect i on Request Line: 281-470- 5130 "' BLOG MECHANI CAL PERM T'" ---------------------------------------------------------------------------- Application Number . . . . . 20-00002355 Date 6/24/21 Pr oper t y Addr ass . . . . . . 1112 W M1AI N ST 200 HCAD Nurrbar: 023-183-050-0007 Al t er net a Sear ch Mat hod: Appl i cat i on t ype descr i pt i on REMODEL, COMMERCI AL Subdi vi si on Name . . . . . . LA PORTE Property Use . . . . . . . . Property Zoning . . . . . . . NOT YET I DENTI FI ED Appl i cat i on vat uat i on . . . . 116505 ---------------------------------------------------------------------------- Type of V`br k INTER ALTER FOR NEW TENANT LAYCUT ---------------------------------------------------------------------------- Oemer Cont r act or PI RZADEH HADI JEPM ELECTRIC LLC ZAMIANI BEHROUS 3198 ROYAL LN SUITE 209 C 111 N 10TH ST DALLAS TX 75229 LA PORTE TX 775713101 St r uct ur e I of or met i on 000 000 Const r uct i on Type . . . . . NON- COMBUSTI BLE I I Occupancy Type . . . . . BUSINESS Other st r uct info . . . . . FLOOD ZONE ae ---------------------------------------------------------------------------- Perrrit . . . . . . BLDG PERM T MECHANICAL Additional desc . . MECH FOR COMM REMODEL Per rri t pi n nuryber 678284 Sub Cont r act or MOUNTAI N TOP HVAC- R LLC Per ni t Fee . . . . 81.00 Plan Check Fee .00 I ssue Date . . . . 6/ 24/ 21 Val uat i on . . . . 18000 Expi rat i on Dat e . . 12/ 21/ 21 Q y Unit Charge Per Extension BASE FEE 30.00 17.00 3.0000 THOU MECH - $1001 & UP 51.00 --------------------------------- ------------------------------------------ Speci al Not as and Comrent s January 11, 2021 9:56:07 AM LAPOILW COMMERCIAL PERM T NOTES 1. ALL NEW DEVELOPMENT MUST OBTAI N A MTER ACCOUNT THROUGH THE Cl TY OF LA PORTE VIATER DEPARTMENT @ 281- 470- 5020 PRI OR TO BUI LDI NG PERM T I SSUANCE. 2. ALL VCRK MUST COMPLY W TH THE APPROVED PLANS, I NSPECTI ONS. 3. CONTRACTOR MUST COMPLY W TH ATTACHED FI RE MARSHAL PLAN REV] EW COMMENTS I F APPLI CABLE. Ci t y of La Por t e 604 W Fai rrront Pkwy La Porte, Tx 77571 I nspect i on Request Line: 281-470-5130 "BLDG MECHANICAL PERM T"" Page 2 Appl i cat i on Number . . . . . 20- 00002355 Dat a 6/ 24/ 21 ---------------------------------------------------------------------------- Speci al Not as and Comrent s 4. OJWERICONTRACTOR RESPONSIBLE TO CCWLY W TH TEXAS ACCESSI BI LI TY STANDARDS (TAS) AS REQUIRED. 5. THI S BUI LDI NG PERM T APPROVED SUBJECT TO CITY APPROVED CONSTRUCTION DRAW NGS W TH RED LI NES, PLAN REVI EW COMVENTS & CERTI FI ED SITE PLAN & I NSPECTI ONS. 6. 1 F ANY FI LL DI RT I S BROUGHT ONTO THE SITE OTHER THAN I NSI DE THE BUI LDI NG FOOTPRI NT, A SEPARATE FI LL DI RT PERM T I S REQUI RED. 7. ANY FUTURE REWDEL OR BUI LDCUT OF OFFICE SPACE REQUIRES SEPARATE PERM TS AND I NSPECTI ONS. 8. SEPARATE ELECTRICAL, PLUNBI NG & MECHANICAL PERM TS REQUIRED FOR ANY RELATED WORK. 9. ANY NEW OR PROPOSED SI GNAGE REQUI RES A SEPARATE SIGN PERM T BEFORE I NSTALLI NG ANY SI GNAGE. 10. CALL FOR I NSPECTI ONS BEFORE ANY VORK I S COVERED. 11. FI NAL ENERGY CODE CERTI FI CATE OF COWLI ANCE REQUI RED FROM I CC CERTI FI ED 3RD PARTY ENERGY CODE INSPECTOR BEFORE BUI LDI NG FINAL 1 NSPECTI ON IF APPLICABLE. 12. ANY CHANGES TO THE APPROVED SET OF PLANS OR APPROVED SCOPE OF VCRK MJST BE APPROVED BY THE I NSPECTI ONS DI VI SI ON PRIOR TO COMVENCI NG CHANGES IN THE FI ELD. 13. SN13KE DETECTORS REQUI RED TO BE INSTALLED AS PER THE 2011 NEC HARDW RED AND INTERCONNECTED IF APPLICABLE. 14. GFCI RECEPTACLES REQUIRED TO CCNPLY W TH THE 2011 15. ALL AREAS INTENDED TO BE UTILIZED FOR PARKING SPACE AND DRIVEVAYS SHALL BE SURFACED W TH M4TERI ALS SUITABLE TO CONTROL DUST AND DRAINAGE. 16. CHECK APPLICABLE DEED RESTRI CTI ONS AND HONE OJWER ASSOCIATIONS FOR ANY OTHER POSSI BLE REQUI RENENTS OR REQUI ARED APPROVAL. 17. M NI MJM SI X- I NCH (6 ) STUD VALLS SHALL BE REQUI RED VWERE DRAT N, VASTE, AND VENT PLUNBI NG IS INSTALLED. Ci t y of La Por t e 604 W Fai r n-Dnt Pkwy LaPorte, Tx 77571 I nspect i on Request Li ne: 281-470- 5130 "BLDG. NECHANI CAL PERM T* " ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 20-00002355 Date 6/24/21 ---------------------------------------------------------------------------- Speci al Not es and Comment s 18. ALUM NUM CCNDUCTCRS MAY BE USED IN COWERCI AL APPLI CATI CNS AS FOLLO S: OUTSIDE AERI AL CCNDUCTCRS, AND SERVICE ENTRANCE CONDUCTORS. ---------------------------------------------------------- ----------------- Fee summery Charged Paid Credited Due ----------------- ---------- -------------------- ---------- Per ni t Fee Total 81.00 81.00 .00 .00 PI an Check Total .00 . 00 . 00 .00 Grand Total 81.00 81.00 .00 .00 ---•- = ------------------------------ -------------- UY\ -- gnat ur a of con—t—r acR— or or Aut hor i zed nt Appr oved by Bui I di ng Of f i ci al or Aut hor i zed Agent Dat e City of La Porto Planning & Development Phone: 251.470.5073 604 W. Fairmont Pkwy BUILDING MECHANICAL PERMIT APPLICATION Fox 281.470.5005 Lo Porto TX 77571 pennib®Iaponotzgov 1. PROJECT INFORMATION RESIDENTIAL PROPERTY ❑� COMMERCIAL PROPERTY— PROVIDE VALUATION OF, MECHANICAL JOB $ $18,000 ADDRESS: 1112 W. Main St. La Porte Texas 77571 HCAD (PARCEL NO.): DESCRIBE WORK: Complete new installation with 5 tons of Cooling rooftop Unit and ductwork NOTE: MECHANICAL VENT HOOD REQUIRES DRAWINGS FOR REVIEW PRIOR TO PERMIT ISSUANCE THIS MECHANICAL JOB IS PART OF A BUILDING PROJECT: RIYES FINO IF YES, PROVIDE BLDG. PERMIT NO.: 20-2355 2 PROPERTY OWNER: NAME: na PHONE NO.: MAILING ADDRESS: E-MAIL 3. MECHANICAL CONTRACTOR: COMPANY NAME: MOUNTAINTOP HVAC-R PHONE NO.: 832-888-2901 E-MAIL: MOUNTAINTOPACQGMAIL.COM FAX: MAILING ADDRESS: 39 ORCHID GROVE PL THE WOODLANDS TX 77385 CONTACT PERSON'S NAME: Ivan Mendoza PHONE NO.: 254-434-1695 4. NOTES TO APPLICANT: NOT A VALID, PERMIT UNTIL CONTRACTOR IS NOTIFIED OF APPROVAL AND ALL APPLICABLE FEES ARE PAID IN FULL • CERTIFICATE OF GENERAL LIABILITY INSURANCE AND STATE LICENSE MUST BE CURRENT WITH STATE OF TEXAS AND CITY OF LA PORTE. PROVIDE CERTIFICATE OF GENERAL LIABILITY INSURANCE WITH CITY OF LA PORTE AS CERTIFICATE HOLDER AND STATE LICENSE TO REGISTER (NO ADDITIONAL FEE). • MECHANICAL PERMIT REOUIRES A LICENSED HVAC CONTRACTOR FOR PERMIT ISSUANCE. • RE -INSPECTION FEE: (RESIDENTIAL $10.00); (COMMERCIAL $35.00) • PERMIT FEE: (RESIDENTIAL $10. FLAT ); (COMMERCIAL: BASED ON MECH. VALUATION) • COMPLETE APPLICATION AND L SUPP RTIN OCUMENTS ARE REQUIRED PRIOR TO PERMIT ISSUANCE. APPLICANT SIGNATURE: PRINTED NAME: IVAN MENDOZA DATE: 06-24-2021 STAFF USE ONLY APPROVED FOR ISSUANCE BY: DATE: CO r t T o2O�I PERMIT NO..: /9�7 —cZ3SS TOTAL PERMIT FEE: u Ci t y of La Por t e 604 W Fai r rront Pkwy La Porte, Tx 77571 I nspect i on Request Line: 281- 470- 5130 ' "' BLDG. PLUMBI NG PERM T"** ---------------------------------------------------------------------------- Appl i cat i on Nurrber . . . . . 20- 00002355 Dat a 6/ 23/ 21 Property Address . . . . . . 1112 W MAIN ST 200 HCAD Nurrber: 023-183-050-0007 AI t er net a Sear ch Met hod: Appl i cat i on t ype description REMDDEL, COMVERCI AL Subdi vi si on Narre . . . . . . LA PORTE Property Use . . . . . . . . Property Zoning . . . . . . . NOT YET IDENTIFIED Appl i cat i on val uat ion . . . . 116505 ---------------------------------------------------------------------------- Type of Vlbr k INTER ALTER FOR NEW TENANT LAYOUT ---------------------------------------------------------------------------- Owner Cont r act or PI RZADEH HADI JEPM ELECTRIC LLC ZANI4NI BEHROUS 3198 ROYAL LN SUITE 209 C 111 N 10TH ST DALLAS TX 75229 LA PORTE TX 775713101 St r uct ur e I of or Trot i on 000 000 Const r uct i on Type . . . . . NON- COMBUSTI BLE 11 Occupancy Type . . . . . . BUSINESS Other st r uct info . . . . . FLOOD ZONE ae ---------------------------------------------------------------------------- Per rri t . . . . . . BLDG PERM T PLUMBI NG Additional desc . . NEW PLBG FOR REMCDEL Per rri t pi n nurrber 677799 Sub Cont r act or S PALMERO PLUNBI NG Per rri t Fee . . . . 35.00 Plan Check Fee .00 Issue Date . . . . 6/ 23/ 21 Val uat i on . . . . 0 Expi rat i on Dat e . . 12/ 20/ 21 a y Unit Charge Per Extension BASE FEE 20.00 2.00 3.7500 EA PL - FI XTURES/ DRAI NS/ TRAPS 7.50 1 . 00 7.5000 EA PL - SEVER - NEW REPAI R, REPLACE 7.50 ---------------------------------------------------------------------------- Speci al Not es and Conrront s January 11, 2021 9:56:07 AM LAPOJLW COMVERCI AL PERM T NOTES 1. ALL NEW DEVELOPMENT MUST OBTAI N A WATER ACCOUNT THROUGH THE CITY OF LA PORTE WATER DEPARTMENT @ 281-470-5020 PRI OR TO BUI LDI NG PERM T I SSUANCE. 2. ALL WJRK MJST CCMPLY W TH THE APPROVED PLANS, I NSPECTI ONS. 3. CONTRACTOR MUST COMPLY W TH ATTACHED FI RE IVARSHAL PLAN REVI EW COMVENTS I F Ci t y of La Por t e 604 W Fai r rmnt Pkwy La Porte, Tx 77571 1 nspecti on Request Li ne: 281-470-5130 ""BLDG. PLUM31 NG PERM T""' Page 2 Appl i cat i on Number . . . . . 20- 00002355 Dat a 6/ 23/ 21 Speci al Not es and Comment s APPLICABLE. 4. OVWER/CONTRACTOR RESPONSI BILE TO COMPLY W TH TEXAS ACCESSI BI LI TY STANDARDS (TAS) AS REQUIRED. 5. THIS BUILDING PERM T APPROVED SUBJECT TO CITY APPROVED CONSTRUCTION DRAW NGS W TH RED LI NES, ' PLAN REVI EW COMVENTS & CERTI FI ED SITE PLAN & I NSPECTI ONS. 6. 1 F ANY FI LL DI RT I S BROUGHT ONTO THE SITE OTHER THAN I NSI DE THE BUILDING FOOTPRI NT, A SEPARATE FI LL DI RT PERM T I S REQUI RED. 7. ANY FUTURE REMODEL OR BUILDOUT OF OFFICE SPACE REQUIRES SEPARATE PERM TS AND I NSPECTI ONS. 8. SEPARATE ELECTRICAL, PLUMBING & NECHANI CAL PERM TS REQUIRED FOR ANY RELATED VCRK. 9. ANY NEW OR PROPOSED SI GNAGE REQUI RES A SEPARATE SIGN PERM T BEFORE INSTALLING ANY SI GNAGE. 10. CALL FOR I NSPECTI ONS BEFORE ANY WORK IS COVERED. 11. FI NAL ENERGY CODE CERTI FI CATE OF COWPLI ANCE REQUI RED FROM I CC CERTI FI ED 3RD PARTY ENERGY CODE INSPECTOR BEFORE BUILDING FINAL I NSPECTI ON IF APPLICABLE. 12. ANY CHANGES TO THE APPROVED SET OF PLANS OR APPROVED SCOPE OF VURK MJST BE APPROVED BY THE I NSPECTI ONS DI VI SI ON PRI OR TO CCMVENCI NG CHANGES I N THE FI ELD. 13. SMOKE DETECTORS REQUIRED TO BE INSTALLED AS PER THE 2011 NEC HARDW RED AND INTERCONNECTED IF APPLICABLE. 14. GFCI RECEPTACLES REQUIRED TO CCIVPLY W TH THE 2011 15. ALL AREAS INTENDED TO BE UTILIZED FOR PARKING SPACE AND DRI VEVV\YS SHALL BE SURFACED W TH WTERI ALS SUITABLE TO CONTROL DUST AND DRAINAGE. 16. CHECK APPLICABLE DEED RESTRI CTI ONS AND HCNE OMER ASSOCI ATI ONS FOR ANY OTHER POSSI BLE REQUI RENENTS OR REQUI AIRED APPROVAL. 17. M NI NUM SI X- I NCH ( 6 ) STUD VALLS SHALL BE REQUI RED VWERE DRAI N, VIASTE, Ci t y of La For t e 604 W Fai r rront Pkwy La Porte, Tx 77571 I nspect i on Request Line: 281-470-5130 ""BLDG. PLUM31 NG PERM T"" ---------------------------------------------------------------------------- Page 3 Appl i cat i on Number . . . . . 20- 00002355 Dat a 6/ 23/ 21 ---------------------------------------------------------------------------- Speci al Not es and Corrnent s AND VENT PLUMBING IS INSTALLED. 18. ALUM NUM CONDUCTORS M4Y BE USED IN COWVERCI AL APPLI CATI ONS AS FOLLCV\S: OUTSIDE AERIAL CONDUCTORS, AND SERVICE ENTRANCE CONDUCTORS. ---------------------------------------------------------------------------- Fee surrrrery Charged Paid Credi t ed Due ----------------- ---------- ---------- ---------- ---------- Per ni t Fee Total 35.00 35.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 35.00 35.00 .00 .00 ----------------------------,QJ256 , �---py ilr----------------- (AV'J02;21 - Si gnat ur a of cont r actor or Aut hor i z ent uat e ------------------------------------------------------- Appr oved by Bui I di ng CX f i ci al or Aut hyor i�zed Agent Dat e City of La Porte 604 W. Fairmont Pkwy LaPorte TX 77571 Planning 8 Development Phone: 281.470.5073 BUILDING COMMERCIAL PLUMBING PERMIT APPLICATION Fax: 281.470.5005 permits@laportetx.gov 1. PROJECT INFORMATION ADDRESS: 1112 W Main St Suite 200 DESCRIBE WORK: New Plumbing Work THIS PLUMBING JOB IS PART OF A BUILDING PROJECT: 7YES ❑ NO IF YES, PROVIDE BLDG. PERMIT NO.: 20-2355 2. PROPERTY OWNER: NAME: Pirzadeh Hadi & Zamani BChrous PHONE NO.: 972 768 7610 MAILING ADDRESS: 111 N 10th St E-MAIL ADDRESS: 3. PLUMBING CONTRACTOR: COMPANY NAME: S. PalmeroS Plumbing PHONE NO.: 281-831-9072 E-MAIL ADDRESS: palmerosplumbing@gmail.com MAILING ADDRESS: 419 Nicer St CONTACT PERSON: Guadalupe Ramirez PHONE NO.: 281-831-9072 ITEM FEE QUANTITY TOTAL PERMIT ISSUE FEE -COMMERCIAL $20.00 1 $20.00 -- - MINIMUM PERMIT FEE $20.00 FIXTURES, DRAINS. 6 TRAPS $3.751 EACH 2 7.50 SEWER (NEW, REPAIR, OR REPLACEMENT) $7.50/ EACH 1 7.50 SEPTIC TANK, SEEPAGE PIT, DRAIN FIELD $15.001 EACH WATER HEATER $3.75/ EACH " GAS PIPING SYSTEM (1 TO 4 OUTLETS) $7.50 FLAT FEE GAS PIPING SYSTEM (OVER 4 OUTLETS) $1.50/ EACH WATER PIPING AND/ OR WATER TREATING. EQUIPMENT $7.501 EACH INSTALLATION ALTERATION REPAIR DRAIN OR VENT REPAIR/ALTERATION $7.501 EACH VACUUM BREAKER/ BACKFLOW PROOTECTION (1-5) $3.751 EACH VACUUM BREAKER/ BACKFLOW PROTECTION (OVER 5) $2.251 EACH 35.00 4. NOTES TO APPLICANT: NOT A VALID PERMIT UNTIL CONTRACTOR IS NOTIFIED OF APPROVAL AND ALL APPLICABLE FEES ARE PAID IN FULL. • CERTIFICATE OF GENERAL LIABILITY INSURANCE AND STATE LICENSE MUST BE CURRENT WITH STATE OF TEXAS AND CITY OF LA PORTE. PROVIDE CERTIFICATE OF GENERAL LIABILITY INSURANCE WITH CITY OF LA PORTE AS CERTIFICATE HOLDER AND STATE LICENSE TO REGISTER (NO ADDITIONAL FEE). • RE -INSPECTION FEE $35.00 • COMPLETE APPLICATION AND ALL SUPPORTING DOCUMENTS REQUIRED PRIOR TO PERMIT ISSUANCE. APPLICANT SIGNATURE: PRINTED NAME: Sergio Palmero DATE:06/22/2021 FOR STAFF USE ONLY r ? 3 ' a f APPROVED FOR ISSUANCE BY: ATE: \� O` PERMITNO.: aO�S TOTAL PERMIT FEE: ':Z REQUEST FOR TEMPORARY UTILITILES DATE: 6/17/21 TO: BUILDING OFFICIAL CITY OF LA PORTE LA PORTE, TX 77571 SUBJECT: THE USE OF TEMPORARY UTILITIES FOR CONSTRUCTION PURPOSES AND TESTING OF EQUIPMENTAT '1112 W Main St. Suite 200 La Porte, TX 77571 BUILDING PERMIT NUMBER 657742 Titlemax of Texas, Inc OWNER Moffett constructio LLC AS GENERAL CONTRACTOR JEPM AS ELECTRICAL CONTRACTOR request.the use of temporary utilities for constructionand the testing of equipment, I understand that this in no way gives me permission to occupy or use for storage purposes any building or portion thereofunless permits on the building or portion to be occupied had been inspected, approved, and a Certificate of Occupancy issued. We further understand that the temporary utilities may be disconnected for any violation of the Code. The General Contractor and owner assume the responsibility for any violation of any city ordinance by the sub -contractor. Temporary electrical permits are In force for 3 months (90 days). 1f more time is required to complete the building, a new application shall _be submitted by a licensed electrical contractor and be accompanied by the temporary electrical permit fee. The undersigned hereby agrees to indemnify and hold forever harmless the City of La Porte, its officers, and employees from any and all claims or causes of action alleged to have been Caused directly or indirectly by the temporary use of utilities for which this application is made. I also understand that this request will not be Issued until'all permits required for the building have been issued. I hereby agree to abide by all provisions of the Electrical Code. OWNER: Titlemax of Texas Inc PHONE: 912-721-5973 Moffett Constructio LLC 972-768-7610 GENERAL CONTRACTOR' PHONE: ELECTRICAL CONTRACTOR: JEPM PHONE: 469-321-3684 APECTTONS DEMION\InsoeWonAREOUEST FOR TEMPORARY UTIUTRES daa PREPARED 6/ 08/ 21. 15: 11: 42 INSPECTION TICKET PAGE 2 CITY OF LA PORTE INSPECTOR: INSPECTOR DATE 6/09/21 ------------------------------------------------------------------------------------------------ ADDRESS : 1112 W MAI N ST 200 SUBDI V: LA PORTE CONTRACTOR JEPM ELECTRIC LLC PHONE OWNER PI RZADEH HADI PHONE PARCEL 023-183-050-0007 APPL NUMBER: 20-00002355 REMODEL, COMMERCIAL ------------------------------------------------------------------------------------------------ PERMI T: EL 00 BLDG PERMI T ELECTRICAL- COMM - REQUESTED I NSP DESCRIPTION TYP/SO COMPLETED RESULT RESULTS/COMMENTS ELI N 03 --61 09/ 21— —1 N" ELEC, ELECTRICAL SERVICE TI ME: 08: 00 Please reach out to me at 214-717-3931 for inspection L results, thank you. i ------------------------------- ------ COMMENTS AND NOTES-------------------------------------- 0 5 an�.ty s 7—6-1—/a,4r� �/ IL Gr t ✓. PREPARED 6/08/21, 14:23:26 INSPECTION TICKET PAGE 5 CITY OF LA PORTE INSPECTOR: INSPECTOR DATE 6/09/21 ------------------------------------------------------------------------------------------------ ADDRESS : 1112 W MAIN ST 200 SUBDIV: LA PORTE CONTRACTOR JEPM ELECTRIC LLC PHONE OWNER PIRZADEH HADI PHONE PARCEL 023-183-050-0007 APPL NUMBER: 20-00002355 REMODEL, COMMERCIAL _____________ ___-----------_------_----_--------------_-----_-__________________-__------ PERMIT: CR 00 BLDG PERMIT -COMMERCIAL REMODEL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ FRAM O1 6/09/21 IN BLDG, FRAME INSPECTION TIME: 08:00 06-08-21 ® 7:40AM Santos 214-454-9674 ✓ / Frame insp -------------------------------------- COMMENTS AND NOTES -------------------------------------- PREPARED 6/ 03121, 17: 27: 28 I NSPECTI ON TICKET PAGE 7 CITY OF LA PORTE INSPECTOR: INSPECTOR DATE 6/04121 -------------------------------------------------------------------------------------------'---- ADDRESS 1112 W MAIN ST 200 SUBDI V: LA PORTE CONTRACTOR JEPM ELECTRIC LLC PHONE OMER PI RZADEH HADI PHONE PARCEL 023-183-050-0007 APPL NUMBER: 20-00002355 REMODEL, COMMERCIAL ------------------------------------------------------------------------------------------------ PERMI T: EL 00 BLDG PERMI T ELECTRICAL- COMM REQUESTED I NSP DESCRI PTI ON TYP/SQ COMPLETED RES RESULTS/COMMENTS ------------------------- - _------_-__--___-_---------__-----------____-________-----_------- ELI N 02 6/ 04/ 21 I N ELEC, ELECTRI CAL SERVI CE TI ME: 08: 00 6/3/21 Q 4:54 214-717-3931 ELEC NP.LL COVER 61312021, 5: 23: 17 PM LAPOVFL ------------------------------------- COMMENTS AND NOTES v PREPARED 6/ 03121, 7: 0 1 : 33 I NSPECTI ON TICKET PAGE 5 CITY OF LA PORTE INSPECTOR: INSPECTOR DATE 6103/21 ................................................................................ ----------...... ADDRESS 1112 W MAIN ST 200 SUBDI V: LA PORTE CONTRACTOR JEPM ELECTRIC LLC PHONE OWJER PI RZADEH HADI PHONE PARCEL 023-183-050-0007 APPL NUMBER: 20-00002355 REMODEL, COMMERCIAL ------------------------------------------------------------------------------------------------ PERMI T: EL 00 BLDG PERMI T ELECTRICAL- COMM REQUESTED I NSP DESCRI PTI ON TYP/SQ COMPLETED RESULT RESULTS/COMMENTS .......................................... ELI N O1 61 03/ 21I..ELEC,ELECTRICAL.SERVICE...TI ME.08: 00................'----'---- -__-__ JEUe/ 2/ 21 C 3: 00 369-431-9939 OR 469-849-7310 ELEC ROUGH 61 2/ 2021. 5: 11: 52 PM LAPOVFL ______________________________________ COMMENTS AND NOTES-------------------------------------- MARSHAL RLA �RTE IlkFIFE LA PORTE -' FIRE MARSHAL'S OFFICE "PLAN REVIEW" RESTAMP - U Date 01/07/2021 / Re -Stain C Meekins 05/24/21 Business Name TitleMax Address 1112 W Main St Type of Review Construction — Suite Buildout Contractor TBD Reviewed by B. Hazeigrove, Deputy Fire Marshal City Permit # 20-2355 Approval I Passed The Applicant shall be responsible to ensure the design specifications and plans are complete and In compliance with the requirements set forth In the 2018 International Fire Coda (IFC( and Local Amendments as well as the applicable referenced Standards listed in Chapter 80 of the 2018 IFC. This plan review Is not intended to be fully inclusive as other requirements may be Imposed as warranted by the Fire Marshal or as deemed necessary during on -site Inspections by the Fire Marshal's Office. "THIS PLAN REVIEW MUST BE ON THE JOBSITE WITH THE APPROVED SET OF PLANS" Additional requirements of the 2018 International Fire Code (IFC) may apply per tenant occupancy and use. 1) 2018 IFC, Section 1010.1.10.1 Installation - All Exit doors shall have Fire/Panic hardware installed prior to final inspection; a. ALL locking devices on doors in the path of egress are required to unlatch with one operation. b. Egress doors shall be readily openable from the egress side without the use of a key, special knowledge or effort and shall not require tight grasping, tight pinching or twisting of the wrist to operate. c. Panic hardware shall be in accordance with UL 305. d. Fire Exit hardware shall be in accordance with UL 1 OC and UL 305. e. Thumb -turn / Deadbolts / Double -cylinder locks in the path of egress are not permitted 2) 20181FC, Section 1013.1 -Ensure all exit doors and egress path have er xit/Emergency lights per the 2018 IFC. Exit/Emergency lights shall be installed g5QNVoCire Marshal's final inspection. r I n 3) 2018 IFC, Section 1008.3.2 Buildings - Emergency lights shall be ins4& on the interior and exterior areas of the egress doors prior to the Fire Marshal's final inspection. a) See highlighted areas on sheet EI01 to add exterior egress lighting. Page 1 of 2 125 South 31d-Street, La Porte, TX 77571 * Office: 281-8674603 * Fax: 281-8674629 4) 2018 IFC, Section 906.3 - Fire Extinguishers shall be mounted every 75' of travel to include all floors prior to the Fire Marshal's final inspection. Refer to Sec 906.3 to determine the actual Fire Extinguishers size/type that this location will require. a) 2018 IFC, Section 906.5 Conspicuous location - Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel.. 5) 2018 IFC, Sec 1010.1.9.4 — Install signage on front and rear egress door to state "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED" 6) 2018 IFC, Sec 907.3.1 Duct Smoke Detectors — Exception 2 requires that the actuation of a smoke detector shall activate a visible and an audible signal in an approved location and shall be identified as air duct detector trouble. a) Sheet M100, Plan Key Notes 2 indicates there will be a duct detector. You will need to install a visual and audible device to be seen from inside of the suite to indicate activation of the duct detector. This will be verified by the FMO inspector during the final. 7) 2018 IFC, Sec 310.3 — Install "NO SMOKING" signs. a) City Ordinance Sec 34-56 — Smoking is prohibited within 25 feet outside entrances, exits, or wheelchair ramps serving any entrance or exit, operable windows, and ventilation systems of enclosed areas where smoking is prohibited. ilding will require a Page 2 of 2 125 South 3rdStreet, La Porte, TX 77571 * Office: 281-867-4603 * Fax: 281-867-4629 ABBREVIATIONS —Ace,,I. .'e SUMMARY OF WORK/SCOPE .iwaw.wnwi SATELLITE MAP x. ILA TITLEMA TRLEMAX 47989 TM LA PORTE TX 1 1112 W Main St. La Porte TX 77571 LOCATION MAP v' v .m.., H-v GENERAL NOTES .. xMrlO.rw.EYOeM®Mlti.MNM.TMM1xWMMYOMIItliI'rYM,Oe. .aMdrox Kam.., aMMr�..,...T x,xmror.,.o�.a,.r.a..,.roxx..T. wr�oacvxmn..e.w.•.s.u..o..®r...rm�.,.r w........ao.or . +.a ..®.mn a mnmwan+roxcrvww� oo«i.....r�..a.wne++I.. w, .. a+owvrm....umrwnwo,rwme.o.mwrsa+o �...�vc�.x r.°x.. �.uw.rma au•c...mraaa�,mm. w �� m,.ow..wrm�w�.,®sn ruxoan..nix..n.. vra.nr. a .m. .o•. rusa,ww.vr. n mro rma ..e,an..�m.. rn +vm.i.va.on..awre..ar�a.oro ro.,xw..x,o rm...w.... Mxxe . sxo...rnx..s.neex...xx•.,M.nuc. a,ro��.m+..ox n .anr�xwn .me.wmva�msm�wx..wn.viwwsroemunw.rnvaexwooe>umn.+uvmmwxw.n.m.un�scawn. Received ,nspections Division Cit, of le Porte OWNER & CONSULTANTS CONTRACTOR RESPONSIBILITIES JURISDICTION INFORMATION C 1 .. Z. 1 ceNe AlF.A� g. PROJECT CONTACTS mna. mwnn. mr.�rvumw. ..w. �...wmmM w.w nso o.sao. ns..¢•mn r.mmm nmmm mu 21 TM LA PORTE I um •awe uRwwraA u rart.nmri i% ADJACENT PROPERTY ADJACENT mE ADJACENT . TENANT, TENANT i ... ... ; E O .:.:::.. . . 6 b b � 8 co ofP N (n K W.R':.eOlPq {LnO.iO WO.Y Z ' w .we.aaaW s �A � .uwwo:os�rw co i4RO.�i WC.WI W.iw m w KWG_W V/:4 A:L.iYW .Wi.NY Z W Q O Q REVIEWED OR CODE iOMPt ANCE Received MAV 21 TYInsPeY ns of m .0 py G IOC RI �cnK W .WIIVAWr M[}IF LLY.I�H I •mo OWpY YIQ. Gn M Y)nl.ily n mmm: gwa.W:w TM U PORTE I 111) W YN19 u ronen� me mw >oa A001 SPENCER HWY Kb.IpOY.0 N.ifyF.yM �a.RIbM r.KO MERPuua U.,O.i MOfI fA'M P�iw.nA Yµ f O. FPFlC�9C...MW • FYM�q ��1nMf� Wn b R.nOmYI.P 01.F®.O .w�K�im n'mono: a uu+imF � ,.F.,�. •...� ,r-m.w.o. r.iC.r.M aaaslzYw,l.�e mo M W..O�iIF.. o�ow IuuQ, aw nmrasw ewa�.r.n.wlorm .�wa.R�w, ..:ensamoea Imn®ra�eFs�r.osa K F.OYIfi .°•.ap.'s an m m.�nns.e �rw. a KFw.i4q.•uf�OYtlNKR.0� .M�mlilaTrOYMfM.i C�W�,MV.YY.M�lvrOF YOFF/nM awnY.i IWtWF � - �r70IN OI YaF K WLLMYI M/F.0 MLN, Mn\, F vOI�FCwr4p>�p Y IM1I�YIiq'.F Ty V C F'Y I REVIEWED FOR j �n ' OMPIRlAMBE DE i P 2 1 2021 �Ay � I pwis InsPectlo la port C'dy i TM LA PORTE 1 YIN.RIP, 1 IIIIXYMI➢ Imo O Fcrnwr.r NICEl. YY 1J91 j 9f beA mIa ' al lw� F>t.MmF.�\L.b Y D10O ; _� ° w.. \ 0s1R4'l1,lY•I0 fdM ( ( RnC.IYROOI.v� RFYFVnnFp O P P \ srm.c.Irnsmu.�J P nnclwnsm.r p 0 R.I.R..nCM...Yfd... ( RSFanncw as m.r per- :-.-.-•���.a©��i ciaca�QJ- NFN fVYy1 TA1ROf�8 IEW T4%WML ICE IfWW/LL.M1 WTEAYL ,�NiEA 7 TW MEN(APFA EtfVATICN ,, TPfIbY� -Qr�t1 ®r��0 •-�F:. _-tamer.--�O �o �o .aERFLnre oart,.mm.w. pxA rF r 1. OBOE]6S. W�.W vn o o.amres�ec�ei r. maa�aa �.mve �'� M1 e62 D11 cer uxbsu MAlb�it amm¢v. ire � �t y IMMEW a 49f �a`�am�Mu�,uW'..uarpp Received mi-Pactlons TM LA PORTE 1 RME "T i iiTw wws u rna n nsn Al00 fNTERPLAPF rw� u, m sv°wal Z MTtl On 61� t?•1'd n O M WH191(W EIECIXICLL DR r\ M WiNMIC On O EIILOVFE CE91t8 � F � crx.:.0 ovrs r t? • 1'd U V! • I'd s••- m•' c, \ t,lHw6A n rtn.�,n,.ae cnc'q,eaw IpN Im BF ° a .... ®r r y yM MTA'MN �aurEaa..r. A'� wwwn °oq ecC�on 4 M OATAfMOUIlAIIIlIET on Mwru saw srxwren onnon • �i�� % , C�f� O Otrr•rd Otrr•rd ° I •I'd 81^°E°�'®`"t�"`�1^1°'� {`,� e �w mart r - � I 1 TM LA PORTE 1 • "^ Itrtw. sr s d IrowEn�rn wxrACE auw �� w Y Al W i o - �r OfrEPPLAPC EFM. T :o >uEo maamm n .wu F.xHcma. n,nruar ?G r"tu�oi.+.ar SEEM e rxEmogs „EGW.LIL EVII..E Eg FMI'. tS„T t PEa,SEEn xu a oiPrwoE i.•, x a Gf 5 y �,p\Qf[(J 1p111Na ,4AEM8 E%iFMORwNLP.,OE t EW7 { E P l OEt M1µL a E>� P P,p[ RECE59FD iIXf1/E: 1 Nw, LmYitlm E FCE99ED FI%RIIE CES i5 Xw S4'LED Lv�urm EEEMiENCYFM11F8 MIS Qi�VPi� ' E,EXGENCr EIGI? t NN Cwwndw SIMMINEEMEJ _rav MENIMEMEM } ` S E%It 51GM.10" J , 1EY, fiYYullon f" C W E ® ....... O g6)' WIN_` TM LA PORTE 1 t ® ••• �.•• i zwwwn I Al02 ^�amEEaPa PEAK wcsa..ti. 1 U iM'• 'd �■f►t��il w�� '��iiiil V•."'I ■�itt�lil �t:�■I �I i�l�����1 tit�t��tt�■I TITLEMAX FF&E SPECIFICATIONS INTERIOR 'um YSY.rowmYYmuY ww.w Muev=w rowb. vw.4p Yr�m�wp.Va.Me. .T<O+.Oii R.V Yo..n mwmirm.mwm.m.nvm "" wP®.Iwrlw�! � +We4�.<aenw�nrosro wiromwma •u Mf0Y.1.P.4nlw1 '� roOOfIAy MN'w�rro Y ✓It.MM.. LppIY�.M® wt w.Mf. ryYM..> Yf.Y®i m...=va.ms.m �..ro.:udw �� �Ye..Y..X�: ML.EMAX FF&E SPECIFICATIONS EXTERIOR �o � mnar�.n Y°nP. MVu�ryuwwY _ eYnY. .Y.wnr a> ....wa.4m�r..�...uw M.x. •Y.....+w. Y.w n.swr�wW �' suc.�Y.�.urY.a M.wwLrim IY�W:Y.wY MICfA�Y.Y VYw�WIP ma w y.� 1099Y�wY/felwY0roYi�y M.0YYgl�pi. __ p.roV.M�.�.0.a10Y.W1YP MYY. Y�.aw on.am.w.nY uwY�Y.�..w.+sw..mv.a w°m`.nYwmYw.Y.n�v.u.w...Ynaa .on •�w.w. vow oow we..Y.auro ro s�.. em.m oo-w.. : r'�'�.xaro`� wu m�"�'w. .urYun..00ma�owrn ro.M miw .MIX�K J�Y�`y�j = OYOI� Ow�"y Y.P�X nItl�XOG w.7� V VV.! nR.N K.Vt F :I.A01A Y M Yi •�Y. wfnY� MwM� 2 roAm •XOGwa M� Y 1swaMa�.Y.unp tau OC Ct ww .mow OD �oPN �eoeNed MPe %or"s P�o�tepP \(\Sp `ky ok \a I EpFORE TMUPORTE �E xj��ip�.iApC urom.n� rocc �w o.e .ma A103 e W.LL AliuUiM ��® CORRECT INCORRECT EXI 0 0 S WM1StRPFE.IY ,.I W W Ww W WM1c ,.a..w.00w�ram w.uaw'w�iaiao� ro.ww..M oe..mo. WM1N/MD:IN 8iW VE3-lY O yr=ea' OSU AREA PERSPECiIYF _ _ A .LLtIM® O .eM Tlll I tiiTmi O .M am ii7T.[il Tlll I tiiTmi O .M am ii7T.[il F cl1 i COPS �," n56z, �'p �a `�6 iv ���• 0 15 WIE V/.i t'V �ww TM IA PORTE 1 scx ..ne. iizw u.Ns 1A H%fE.1X ]l91 A200 W . MXFINAI uua.• ' .LnM,G -MTM MAbIT SOUTH EXISTING EXTERIOR ELEVATION X w o n O co Y mX js1 m w M N 0 r v �� 47989 tip r EXISTING EXTERIOR PHOTOS A201 �a sw Cl" co �noam me e[v�nw M•1'd LLJ 0 O a i�� u 3r m �Nao FOR ���� z,�%iSrE 47989 Renewed SDpe600 p of e � EXTERIOR ELEVATIONS A202 Mbil.l 1]p1IJN0 N�4 y0 IPLMGENERAL NOTE I INAC STMSOLS LEGEND sw.a•e.wwewv.om.w s.•..u.. r\rwaoou I.r.M-rm.v,a.Y. wsr..uDvm.e p ...m4 ® Ymmw x M mN FIELD VERIFY ALL CONDITIONS �a..Rn..vac.m.. W w4�an.Y.D R• .! MT.nG6 M.)..rC waa D<.4....n • rrs w M cv..tiv r mcmnovM uuD w w�'.+.nw YW.s.�wovr"me.cvnJw W ♦M.K.rOgm.m WlOC.rCM..O.OwV w V.D n.m I� D..Y�ev_ i.].OV nYnl IwC b DY r�i Wnv' ibOWLOCOM �a Ky n M M Yw w d.O n M wb DY /.LV 4..N.tlYTO.K.U4 /D4mYA. M DmClbwwA.W waruwawv .m.w.W�unwoW a—D.®M—d w. mo�..•nW w.w•.w..m4aa..ao.ax WD aa+. �w�..oaRwoomR n....i..awso..v ne.,.o.en.wabv.wb.n.Mr.r� �.o ....mwocoumm I HD(DUCT SIZE I HVAC AUREVIATIONS ..iNYr wi�MV.�.V pCwr W M.— YOOtJ4M��a O ®.Y..C1Or Y. . IVWVWII. W DMM 0fM1M I MECHANICAL PLAN 1 uNra .! �rMdr. viiOOr a—...CWiF W.w. rtNWMYwL3 YV.Or—�.. 4m..V ��rV.V/DI.YYiW Dm 1. w0•.Y m. flpwM1.y. L Y.mVYMw.1.000..f Jl.nLW mw.[YD Vn VI�Jl6.Yl'YwO1wtOY.MYwr. N'4 RV.Y�YY®.I.Prw.ONC.OK i1W...Y Y..1 .f.OiK.00 D.�O•.rl.id.wiV VV.mD�VID.N' W.Om/YOW L 4 ii.0'.PrWOOm•D .![IDJm Vwbp.Dm�.—f0.6C0O.iDK.®LO...Mfwl .V 9..iW.VRW(b.Y7dV� .•Y.fw •wl.r.MOm>w idI.W VISA Y.¢wiD4w WOGit mYn. Wos.o-vb.a.amv.v..o.w.�d DWvsia.wmeY...me...v.mma..... ay.sv4•wnw...'I' m�.no:w ..YDrD4. w..�nwrWP.mMI.w.w�M.W Mbuw' br .ILM DRLI.YrLL. F.xi WT nOS.LT.YW..I P.wm MY V mI1mW..Y—.Dwlnwa..m�. D. w.nOwwMDM. WV I vpY ROOF TOP lMf RM SCHEDULE IELECIRIC HEATI I&/� AIR OISTRIION DEVICE SCHEDULE m Ya .- - a ov�..nsmm m.�v W �sm..YaR i rvry •• eo:D..\.iwco� E%HAUST FAN SCHEDULE vn \c+Dn Y+. Du. ry m a •� .N L. ndr n — wY. YIVr n1 mrnu..edbr....e�...mal.o. uow mn 011 u M M1.• W .a OUTSIDE AIR CALCULATIONS a®1 • 1• m. m..r oawW a1 wm' a. waw.Rva. •.n. W tl .VI IaN 4 D +w mwo wLt 9 v I®.IE N 4a149WI i wRIM1 t. •..I(.A m. • IM ® -y Y[yYy YwY�w O..IrwCL.i�.w®mO.tMidM Df a®.a aS .n \earW� NR BALANCE SCHEDULE \ 0®QRY�y.Lp� —.rf iY—w L \waR-.r\..® �ev.w 1—• \ Nm r l \Q �R@ mVY D.V9 1 YlY IVO.. Yt1.LtR • RI lb. mOY6 -.pb.Yw A 0000 YO 41® rIY L I.w6.[m..L®Iat • Dw.9w.1mY m- lY IfiY\L \® A �svw.v wwa.R. • .Iv �•w..®wr. 4+a �.sYnw.d CI A Copy _ r@Rrw 60M wn 7— wY.I Is.w.a. YL.i loa . Q. wY PRr wi • ®o.a wmv..m v a.odwmwosw 4 vw.Iw.m i.4 wYW—• ... rmww.w wvs• \ w:Rv.svaL•a Deis oa <.�srairti ea 9 O� TM LA PORTE I aa.t.ae. nnwDwR uIv¢n nm vXXr. oII PV SPSeN lav r.uo n n¢ a wXm,PXa va— Xv�¢w4�w Nn wrw rotn Xwra Xwnw, J �Na f T�wX uax � �w XNo.NX Irr A ][t6 [YYl[Y, �t YWOA VPrJ BB4R MP( NOR�o 4XLv[.. m_c� m--rmn v talc CONNECTION DUCT HITTING DETAIL rX L 1 7 CONNECTION DRf m DETAIL xn v, O3 EXHAUST VENT THRU ROOF m ISO CABINET EXHAUST FAN DETAIL xa sn` w ®s PI4 R41.w `®prow XYL 6 Nn�w w XwwLL O7 CONDENSATE P-TRAP DETAIL nPaniPvr� ,.I Yrs .In oN�uv �S,IIP�]'WG Fn q, C,�XMYZ Sn eM¢S uiE 4�m1 f� eP..,..raa wmi.�e fl � fmwntl�o.rxu+P PrP n'uP� mom+ ��nnm ��� O4 TYPICAL DUCT HANGING DETAIL m w wX m o,vw...T A,m mmRm _ ai n.s,m M wn One s°�wa w � 'innl�iu �mlivw mw uai new lv. ROOF TOP UNIT (RTU) MOUNTING DETAIL ROOFTOP UNIT mwue.o-XX w � NP ,PR,wN m wDn N.. .m 0 RTU CURB ATTACHMENT DETAIL 61m Xl n, IC yn/, Pnnry P. r®R or�m rm,w e< �m n..rnn.a nn�Pm GENERAL DESCRIPnoN a TME name: gEWIREUEX'IS. M� Pw. ue[wwunM�.lYxM ,x<wlw�rr. o •rxxaro v�"'"�"""�`� Pmlurtrs � ...¢wa LOI PRESSURE WCnM uwlw D4wER�w �•P~+ w�nr.nwmrnnX....ee: �M .N..wfa w.. FlINWS! ry¢ a` m wr-riWiwm�a,r taxmols PIPIxG .n�nEUXrt<M w.P_ __ r'reia�nT maoo�uvnw~s �� .w M 91ptE RiECroRS nit. CRR1f5. IECI51[16 4O DI�uSERS: � PwXiYwwYcm ie,q�imu ciuno Mau,ras IR. itES16tE DUCT m,x�'Hw�[oX+nmmXanuw ,uwr,rioX wr.,airvnnt�m uaa xr n. EXECUTION 9H S ,Ialq `g EURRIC4iesc�wercw II. PIPING. EaUIPVENT !NST4IATICN. III P4XrIXG: Pxm rnruM. n. CIEWIxt 410 NWSInpIS. rznl 4.c canna v cc.Eu PEx onx.N: � YF/SLWINL rE[xNIW6 pcfYVannG�Pe'rorwY.aXw Tm m .®n,s SLB1 Inls xv.0 EWIPNExt ram w�,w CFIIEfNE .- CA ;w FErAICEMIIM 5 = y CD4CPFEP ,m wm [wrow roR x'�. F. -ITTILWITTATIft CMENAR COIL avn�Rwm,m.m:..,wyP�p C'AIINSER Eux .1 uD, Received a� 0.Y 2 � 2e21 1n5P?cu0ns.oTOTte r. C.1tXi O EMT TM LA PORTE I ,pIIE..TM I II}M µY151 umatnRml M200 OM Qart� iA wt..+o.o,wo-r.vi w+l.,a.00�ae TMO°.� Ittuu yawn IS IUVW x. LI I, W4tdYJ15 mr Aowouve nraaw�+a.m� i 3AOd Yl wi �+*mgam.waawr PwCavayewllwl'Itllv�Yun®q�y�iwmY.tl.O i ID. 1v]Ot a. �c'N'u't.anlarv�uwo[rvvwiClvo�cYMA t n.c3.r�o�rwJOua iwn�.�u.�.. ,.wow.... � iww�a ao.ia�avw O u.wm� Wirnwo -- u1 ff w an.xw+ rn3 ar�vi .1h1 =.t/I 13 \i0;.11:NV7dsw3msONVN3MOd1VDIH1039 I SU0��78 \ .y PaN1aoa4a a.C� kLI0 oomc>,00����ov0000�omn �00000a�.�ol oaa�oavoo����oo©000�oamQ�000000� ',oLL�000L�����oLLL�L©000�oQ�m000000�= o �iom©eoomoeo�e®ee®�m�_eooma SIN 13 WVN`.JVIO 33SIM NOIM173H 6 uN 13 nn®HZ)S9NVdW58iJ39 L T � w A rl��lf' r s T T r T r=i— Iwwr +�->_ov000vr=�rvr_000Lvoc_+o �: or +��oeoLvevr_ ero�e0000r+o o,.+000000var�c-vr eeeeo+,+o loceoevoeso�=��o!=00000:dLa ope- 0000wr. -emu _onor�®c10 o. lo::La--�--�-�nonr�r_ +�---�000r�-purr: Y::r•�o_.noor�®ruo uTnoc+r�®+us LeaW o nnClFll=Yr::rm-nnor�mloo W 0nnnr�=u��:: u.�nnnr�®me pIJ p19�+"-�CICICJF'�� CIC)CIFdl=Y: :rrYS',CIC]CIr.]®WO �Yr: :rYS.nC1nGl®Ll0 onLLLsrrur•iu: poorrorrY �=u!_cs+oraaLs �Y.roo ®Lp up oL•ouuuc—urn: uF_nnmv�oup � H. HGER WIRE DETA �F.f3 UGHTWG RIDURE SCHEDULE T�T�T �UGjHN+G RTTURE SCHEDULE • S IIGHIWG CONfROLDUGRMI u�� n -mm��o o.m a• �i,_ MON I� O co 1 `EIECIR V Uc4mNG PLAN 1 1 1i�. ra o �. OCq WxINxIM104xOK4OAm YIIxY1. M� Y.04uRY.R.�RIMgdrwG 1 %�KW M.Ywq�rxdNu'.YATC.4( q..vO7L�Mui. --➢� W V M i� t 0.'gvm.00gCii WtIKY ..xmy.mq loc:lua.gmw.eo...wiac�.eweo.lmq by Slay T Hamm) Daro: 2021.01 CoITY! . mq�goxr w .e�o.cx . w+w+sq.ar..mgmmu.a REVIEW o-r.e.a D FOR CODE eoNgpj_IAI�EE I• 0.¢dgd.x e- a qim �d W TM LA PORTE I I ➢ llm III}.Y.w➢ u I¢ce¢nm E101 PLUMBIMG RTTURE SCHEDULE .rrwc.sam.ro. rm �.v Im,INnw wra+orvoval vvuon iw�+xn..e.c:.rt.IDe4 ..r.N¢N>Nwe�+w®.4 K w� um.oa rvo..q - nw,¢oow.na.wc.^i.urwvn.n'n• nN.wwcaam.umw.orva MwnmTa m MwC O.�M ny. r�Gva a NN.norva...w ar u - - .R um. w.av KR naa.ownn Naemrvora em minuo.awurovs avuou.enzrw t WATER RISER DIAGRAM gmVENT AND WASTE RISER DIAGRAM 1 �+ Cglp wel9 Nwul Q ILv+IR® wane - N Rb CU lw .t.tMN --� "t/ l cao HOx sv axo.[ RANK TO I1 W MAX RANK i0 I10`F MAX ANEW INSTANT WATER NEATER 6 TMV DETAIL 1 ra PIOU I11=1'a GENERAL NOTES. ' (.tM�.O.unrcaiaryp.B�fn M..ta rs'a nau..nwmvenrrswem wo.ureme as menoxl. mewro ou.a%. sw aocv.w.rs eornMvam.wa+eee+rz.wo w.ew�..o.ew+.�c.a ww.wreoc..w warv.Mau nF rc®c«..cww,v.�: aaes,.�a Mw w.lw•m+.wmrva.mnm.�w�ma.ca+ecra. � .or .w�.w�vr..sanowwamm mm.ruewnn.w.n v.oxoNaav�ocwro�n... xxmw. Digitally q-Rj M.LLCMCW®I.Ne'IYixIro M9[U[NE.xJ.A KMU Ns �wA� J nuroMwNc,�w.0 o.®w.muw. uw caa. `°°cn^'c't w Date: 2021. 4433 cISFt rwowurm®s J �a CaaOUR M't.. ww. ovNxm vo w...cwn 0r.a.� C6� PLUMBING PLAN KEYED NOTES Q ecmyv,.mcoomwew�,.cn.aa.ecu...�w.uv v�emw.�.anrN.wnxa m w � m�c�cmwrciawwsvo`«ce.ow,,n�:�."w`av� n,m i `w�c.bce m+w.w Aom`�o.`o:'�`us�os:cP+esmo-a� aievmmuwar.f ww.urz w s ea.� ow. +o M amw.urz.N Aan.�.«ua.00mmcwnwww.vrom i i wwnw.on .vcnvwAx KAa Kw uv.ron. ca»en.a :•eiuea�.+...lw.wmww �,o>reuo¢.m..a.acou.m ...w.c.ens.xoww,mN Re°e�Jea `J\SYpi eG`�pP1 O C�a o, RLmw3tINO W.wfltl®GMI.OLT N wnM N �s —v— mc.,aww aN 10M1ZfY441eW veo MMS519RKL a0Nl rym.nm. anm m. WQ J TM LA PORTE 1 no.E..m. IIIiNYM'II U NYE tY T'S)I Hw amx� Ploo .wc.m a n•w e ARSMAI. LA PORTE LN, FIRE MARSHAL'S OFFICE "PLAN REVIEW" RESTAMP - II Date 01/07/2021 / Re -Starr C Meekins 05/24/21 Business Name TitleMax Address 1112 W Main St Type of Review Construction — Suite Buildout Contractor TBD Reviewed b B. Hazelgrove, Deputy Fire Marshal Ci Permit it 20-2355 Approval I Passed The Applicant shall be responsible to ensure the design specifications and plans are complete and in compliance with the requirements set tohn in me zuia International Fire Code (IFC) and Local Amendments as well as the applicable referenced Standards listed In Chapter N of the 2018 IFC. This plan review Is not Intended to be fully Inclusive as other requirements may be Imposed as warranted by the Fire Marshal or as deemed necessary during on -site Inspections by the Fire Marshal's Office. "THIS PLAN REVIEW MUST BE ON THE JOBSITE WITH THE APPROVED SET OF PLANS" Additional requirements of the 2018 International Fire Code (IFC) may apply per tenant occupancy and use. 1) 2018 IFC, Section 1010.1.10.1 Installation - All Exit doors shall have Fire/Panic hardware installed prior to final inspection; a. ALL locking devices on doors in the path of egress are required to unlatch with one operation. b. Egress doors shall be readily openable from the egress side wi use of a key, special knowledge or effort and shall not require tight gr t pinching or twisting of the wrist to operate. c. Panic hardware shall be in accordance with UL 305. d. Fire Exit hardware shall be in accordance with UL 1 e. Thumb -turn / Deadbolts / Double -cylinder loch egress are not permitted Q 2) 2018 IFC, Section 1013.1 - Ensure all exit doors and egress path have proper Exit/Emergency lights per the 2018 IFC. Exit/Emergency lights shall be installed prior to the Fire Marshal's final inspection. 3) 2018 IFC, Section 1008.3.2 Buildings - Emergency lights shall be installed on the interior and exterior areas of the egress doors prior to the Fire Marshal's final inspection. a) See highlighted areas on sheet E101 to add exterior egress lighting. Page 1 of 2 125 South 31dStreet, La Porte, TX 77571 * Office: 281-867-4603 * Fax: 281-867-4629 4) 2018 IFC, Section 906.3 - Fire Extinguishers shall be mounted every 75' of travel to include all floors prior to the Fire Marshal's final inspection. Refer to Sec 906.3 to determine the actual Fire Extinguishers size/type that this location will require. a) 2018 IFC, Section 906.5 Conspicuous location - Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. 5) 2018 IFC, Sec 1010.1.9.4 —Install signage on front and rear egress door to state "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED" 6) 2018 IFC, Sec 907.3.1 Duct Smoke Detectors — Exception 2 requires that the actuation of a smoke detector shall activate a visible and an audible signal in an approved location and shall be identified as air duct detector trouble. a) Sheet M100, Plan Key Notes 2 indicates there will be a duct detector. You will need to install a visual and audible device to be seen from inside of the suite to indicate activation of the duct detector. This will be verified by the FMO inspector during the final. 7) 2018 IFC, Sec 310.3 —Install "NO SMOKING" signs. a) City Ordinance Sec 34-56 — Smoking is prohibited within 25 feet outside entrances, exits, or wheelchair ramps serving any entrance or exit, operable windows, and ventilation systems of enclosed areas where smoking is prohibited. (ding will require a Page 2 of 2 125 South VStreet, La Pate, TX 77571 * Office: 281-867-4603 * Fax: 281-867-4629