HomeMy WebLinkAbout1210 N BROADWAY ST_19-0825___________1210 N. BROADWAY ST. B
PREPARED 5/02/19, 16:43:08 INSPECTION TICKET PAGE 18
CITY OF LA PORTE INSPECTOR: INSPECTOR DATE 5/03/19
------------------------------------------------------------------------------------------------
ADDRESS 1210 N BROADWAY ST SUBDIV: NEBRASKA SYNDICATE
CONTRACTOR CAPITAL FIRE PROTECTION LLC PHONE .
OWNER ENTERPRISE PRODUCTS OPERATING PHONE .
PARCEL 027-083-000-0011
APPL NUMBER: 19-00000825 UNDERGROUND FIRE LINE
___________________________________________________________ __-_-----_________
PERMIT: UFL Be UNDERGROUND FIRE LINE
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
--------------------------^--n------------------------------____----------------------------------
GRPL 01 5/03/19 IN 4100 PLBG, PLUMBING, GROUND TIME: 08:00
U RGROUND FIRE LINE INSPECTION
/�, SCHEDULED PER DENNI5 FI T CH.
,r SCOTT W/ CAP ONE 713-781-4000
-------------------------------------- COMMENTS AND NOTES --------------------------------------
City of La Porte
604 W Fairmont Pkwy
La Porte, Tx 77571
(281)470-5073 INSPECTION LINE:(281) 470-5130
****BUILDING PERMIT****
----------------------------------------------------------------------------
Application Number . . . . . 19-00000825 Date 4/26/19
Property Address . . . . . . 1210 N BROADWAY ST
HCAD Number: 027-083-000-0011
Alternate Search Method:
Application type description UNDERGROUND FIRE LINE
Subdivision Name . . . . . . NEBRASKA SYNDICATE
Property Use . . . . . . . .
Property Zoning . . . . . . . IND - LIGHT
Application valuation . . . . 80000
----------------------------------------------------------------------------
Type of Work
UNDERGROUND FIRE LINE - ENTERPRISE BLDG B
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
ENTERPRISE PRODUCTS OPERATING CAPITAL FIRE PROTECTION LLC
PO BOX 4018 P 0 BOX 422156
HOUSTON TX 772104018 HOUSTON TX 77242
--------------------- Structure Information 000 000 ----------------------
Construction Type . . . . . NON-COMBUSTIBLE II
Occupancy Type . . . . . . UTILITY & MISCELLANEOUS
Flood Zone . . . . . . . . ZONE AE
----------------------------------------------------------------------------
Permit . . . . . . UNDERGOUND FIRE LINE -PERMIT
Additional desc . . UNDERGROUND FIRE LINE BLDG B
Permit pin number . 595009
Permit Fee . . . . 567.50 Plan Check Fee 283.75
Issue Date . . . . 4/26/19 Valuation . . . . 80000
Expiration Date . . 10/23/19
Qty Unit Charge Per Extension
BASE FEE 387.50
30.00 6.0000 THOU BLDG - 50,001 - 100,000 180.00
----------------------------------------------------------------------------
Special Notes and Comments
April 25, 2019 11:30:26 AM lapoklk.
FIRE NOTES
1. AS PER APPROVED PLANS AND NOTES FROM
THE FMO.
2. CALL FOR INSPECTION.
3. THIS PERMIT IS FOR UNDERGROUND FIRE
LINE.
4. CONTRACTOR/OWNER IS RESPONSIBLE FOR
REMOVAL OF ALL CONSTRUCTION DEBRIS.
5. A BUILDING PERMITS (AND ALL ITS
APPLICABLE SUB PERMITS) MAY BE BASED ON
THE REMAINDER OF THE WORK TO BE DONE.
City of La Porte
604 W Fairmont Pkwy
La Porte, Tx 77571
(281)470-5073 INSPECTION LINE:(281) 470-5130
****BUILDING PERMIT****
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 19-00000825 Date 4/26/19
----------------------------------------------------------------------------
Special Notes and Comments
HOWEVER, IF THE WORK IS NOT COMPLETED
WITHIN THE ALLOTTED TIME OF THE RENEWAL
PERIOD, THE BUILDING PERMIT (AND ALL
APPLICABLE SUB PERMITS) MUST BE APPLIED
FOR AS A NEW PERMIT, AND ALL PERMIT FEES
WILL BE CALCULATED FROM THE ORIGINAL
PERMIT VALUATION.
6. PERMIT MUST BE ON JOB SITE.
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 567.50 567.50 .00 .00
Plan Check Total 283.75 283.75 .00 .00
Grand Total 851.25 851.25 .00 .00
-----------i
---------- -- ---- -- ----- -- ---- ------ - ----- -----------
2C/tea l 9
TURE OF CONTRACTOR OR AUTHORIZED AGENT) DATE
(APPROVED BY BUILDING OFFICIAL OR AUTHORIZED AGENT) DATE
City of La Porte Planning & Development Department Phone: 281.470.5073
604 W. Fairmont PkwY. Fax: 281.470.5005
La Porte,TX 77571 FIRE PERMIT APPLICATION www.lapartetx.gov
1. PROJECT INFORMATION: DATE WUBL4 L LlZ ZU
PROJECTADDRESS(If existing): IZIQ tJ ,•�
HCAD PARCEL NO(s) 13-digit Tax 10(s): 1.) v
2.) 3.)
PROPERTY LEGAL DESCRIPTION:
OFIREALARM ®FIRE SUPPRESSION aVENIT HOOD ® VENT HOOD FIRE SUPPRESSION OUNDERGROUND FIRE LINE
®ABOVE -GROUND FIRE SUPPRESSION ® OTHER
/�N p
DESCRIBEWORK:t�Im Lamm as—W— l)gnee(1Le•Cl)Lo 'FLaE La"_
'RI.IJG PIG
BUILDING USE: LA8 p 6U NSF NO.OFSTORIES: TOTAL SO. FOOTAGE: 73li0Q_PROJECT VALUATION: $ s OC>d
2. PROPERTY OWNER CONTACT INFORMATION:
OWNER'S NAME: ! /N ¢ (-L�CS�E PiL`�ULi K ,.�}�t, PHONE: I I ?J'"`,,I,.'����[J �7
MAILINGADDRESS: '1100 LW IS QAAI SI Ill• •' 'Pt cDa V6SI L1..J� � IVQ7i -
E-MAIL:
3. CONTRACTOR/AGENT: ® *HOMEOWNER IS CONTRACTOR
AGENT/ CONTRACTOR COMPANY:( Mj
PHONE I: S- -7B 1-�4/•,I�i PHONE2:
E-MAIL:4UAL-I PrCIC✓C-&eF-I LZE•L)S FAxa: "lI3'78 I'�062
MAILING ADDRESS:�r�r (((L^'`//���� SLI?F LCIt]{J�T(1 .pp Z�r1�Z
CONTACTPERSON'S NAME: �L,t"fe• PHONE: '11'?,—
4. APPLICATION CHECKLIST & SUPPORTING DOCUMENTATION (Check applicable boxes):
*If Homeowner is Contractor,
COMPLETE ITEMS 1-4 OF PERMIT APPLICATION must furnish notarized
SUBMITTWO (2) COMPLETE SETS(HARDCOPIES) OF CONSTRUCTION PLANS FOR REVIEW Homestead Affidavit
NOTES TO APPLICANT:
1. CONTRACTOR MUST BE REGISTERED WITH THECITY
2. TO REGISTER WITH CITY, SUBMIT CURRENT CERTIFICATE OF INSURANCE WITH CITY NAME& ADDRESS AS CERTIFICATE HOLDER
3. NOT A VALID PERMIT UNTIL
LOOW-NER/CONTRAACTOR/15 NOTIFIED OF APPROVAL AND ALL APPLICABLE FEES ARE PAID( FUL
APPLICANT PRINTED NAME: �ctTT-f CJA-JU66-. APPLICANT SIGNATURE:
(STAFF USE ONLY): rt((77���AA,,r�-� tFLL����/
Occupancy Type:_ Const.Type:,{{gp��16 Flood Zone: K Use Zone (Zoning District): L` CEP; Taxes7;ye,
FEES: PERMIT FEE: $ % -• So PLAN CHECK FEE. $ a.� 3 •� S
RESIDENTIAL DRIVEWAY TIE-IN FEE: $ PARKLAND & ZONE FEE;
Special Conditions:
® Must complete all work andpass City Inspection within 10 days of permit Issuance to ovoldfurther Code Enfon:ementAction
PERMITAPPROVAL: Fire Marshal (Commercial OnlyJ• Date:
Approved j r Issuance by: Date:
PERMIT NO.
ORTE
-uARELA FORTE.
FIRE, MARSHAL'S
LnI.ICF-.. .OFFICE;
"PLAN REVIEW"
Date
04/23/2019
Business Name
Enterprise Products
Address
1210 N. Broadway — Building "B"
Type of Review
Under -Ground Fire Protection
Contractor
Capitol Fire
Reviewed by
Clif Meekins, Fire Marshal
City Permit #
19-
Approval
YES
The Applicant shall be responsible to ensure the design specifications and pans an complete and in compliance vdm me requirements as iortn in me mm
Intemadonal Fire Code (IFC) and Local Amendments as well es the applicable referenced Standards Haled In Chapter e6 of the 2016 IFC. This plan reviser Is not
intsndod to be fully Inclusive as other requirements may be Imposed as warranted by the Fire Marshal or as doomed necessary dudn0 on-sim Inspections by the Fin
Marshal's Office.
"THIS PLAN REVIEW MUST BE ON THE JOBSITE WITH THE APPROVED SET OF PLANS"
1) RME from "Capitol Fire" shall be onsite for ALL Fire Marshal's inspection, NO
EXCEPTIONSH
2) Pipe shall run exactly as permitted; any deviations in design, installation, materials or installation
methods may void the issued permit and cause delays in the inspection process.
a. Pipe shall run straight and true between thrust blocks with negligible deviation.
3) ALL Thrust Blocks excavations shall be clearly visible for inspections but thrust blocks shall not
be poured. Refer to "Inspection Requirements" in this approval for details.
4) Under -Ground Fire Protection system in its entirety to terminate I' above grade.
5) FDC shall be a 5" Storz, capped, with 30 Degree downward Connection.
6) The tamper and flow switches shall be tied into the building fire alarm.
7) The Above -Ground Fire Protection system shall not be tied into the UG Fire Protection system
until the UG system has been hydrostatically tested, flushed & passed by this office.
8) Valve Pit must conform to 2013 NFPA 13, Section 8.16.1.4 Valves in Pits.
9) Valve Pit shall have a Sump Pump installed to control rain and ground water.
125 South 3`d Street, La Porte, TX 77571 * Office: 281-867-4603 * Fax: 281-867-4629
10) Inspection Requirements: A minimum of three (3) inspections shall be required for
underground piping serving sprinkler systems and/or private hydrants: 1) Pre -pour inspection; 2)
Hydrostatic testing; 3) Flush inspection.
a) Pre -pour inspection: Thrust block excavation shall be completed, but thrust blocks shall not
be poured. All pipes shall be in place and exposed for visual inspection. Pipe shall be laid on a
minimum six-inch bed of clean sand. Trench shall be of a sufficient depth to allow the required
cover above pipe.
b) Hydro Testing: Thrust blocks shall be in place. Pipe shall be center -loaded with clean sand to
prevent uplift, but all joints shall remain exposed. The system shall be hydrostatically tested at
200 psi (or 50 psi over maximum static pressure, whichever is greater) for a duration of at least
two hours prior to the arrival of the inspector and shall be holding pressure when inspector
arrives. The flush and hydro inspections may be scheduled concurrently.
c) Flush inspection: All portions of the underground system shall be flushed to remove debris
prior to connection to overhead piping. Flow shall be through a minimum of a four -inch hose
or pipe, unless otherwise approved by the inspector prior to scheduling the flush. Hose or pipe
shall be restrained to prevent injury and damage. The flush and hydro inspections may be
scheduled concurrently.
1 I) The Fire Marshal's Office approved set of Fire Sprinkler Plans, manufacture's product data sheets
on all equipment being installed, and the installation permit are to be on site for all Fire Marshal's
Office inspections. The On -Site Installer shall have a current State license, on his person, while on
the job site.
12) The Under -Ground Fire Protection system piping shall not be covered up prior to the Fire Marshal's
Office visual inspections of the piping. If the piping is covered, and the inspectors cannot inspect
as is required by Fire Code, all of the obstructions will be required to be removed. NO
EXCEPTIONS!
125 South 3"' Street, La Porte, TX 77571 * Office: 281-867-4603 * Fax: 281-867-4629
FIRE LINE PERMIT NOTES
1. CALL FOR INSPECTION
2. AS PER FIRE MARSHALL PLAN REVIEW AND NOTES
3. THIS PERMIT IS FOR FIRE LINE
4. CONTRACTOR/OWNER RESPONSIBLE FOR REMOVAL OF ALL CONSTRUCTION DEBRIS.
5. A BUILDING PERMIT (AND ALL ITS APPLICABLE SUB PERMITS) MAYBE BASED ON THE
REMAINDER OF THE WORK TO BE DONE. HOWEVER, IF THE WORK IS NOT COMPLETED WITHIN
THE ALLOTTED TIME OF THE RENEWAL PERIOD, THE BUILDING PERMIT (AND ALL APPLICABLE
SUB PERMITS) MUST BE APPLIED FOR AS A NEW PERMIT, AND ALL PERMIT FEES WILL BE
CALCULATED FROM THE ORIGINAL PERMIT VALUATION.
6. PERMIT MUST BE ON JOB SITE.
a
0 0 0 0 0 0 0
11►1.��vu.
a �
O
a cn I
O O O O N
1 1.4 o Vi I "G
R
O 6 6" S.S AMES 'IN -BUILDING' I A.1 O
RISER (OR EQUAL). 1'-0" AFF.
O SPG O
O I 1 O
i
JA
O j. O
O u l
O I F rn
I
n
O rr
•
--- — -
i
O
-- O 1
I
. _ .. C)
O O P
0
O O
0
—•-
y
OO _.....
-- — 0
O O
-- -- O
O
O O l
._._.__ - --- . ELL LO �
I
I OO O O O LOION OF BUILDI OO 0 o O
FIRE DEPARTMENT
Q)
C
ONt ECTION. REFER
0 O
— _ — — — TO PLAN �01�
FOR ONTINUNTINUATION. '
0 8" BACKFLOW ASSEMBLY WITHIN
s S S S ACK L W ASSEIiLY WITHIN
S"" S
„ „ i --- TO DETAIL THIS SHEET FOR 6 I
O PIT. BUILDING A UPPLY. REFER �� l NTINUATION. 101-7
_ — TO DETAIL. THIS WET FO I c-soo
O O CONTIN000C O O
O 0 I FP
(� TS&V SUPPLY FOR BFP 8" TS&V SUPPLY FOR C-900
BUILDING "A" " BUILDING "B"
N�
12CITY -- -- - _- --- " EXISTING CITY MAIN CITY 12" EXISTING CITY MAIN
THRUST BLOCK PER NFPA24 (TY) OEXISTING CITY HYDRANT TO
EXISTING CITY HYDRANT TO REMAIN
REMAIN
MODEL
SIZE
L1
W1
H1
WEIGHT
LBS
DTC4
4"
6'-0"
Y-6'
4'-0'
3,500
DTC6
6"
6'-0"
3'-6"
4'-0"
3,500
DTC8
e"
W-2"
W-0"
6'-6"
17,000
DTC10
10"
9'-2"
5'-0"
6'-6"
18,000
6"
PLAN VIEW
NDICATING:
:QUIP. CO.
041
ACTURED
LL-THREAD
DD (TYP.)
COVER &
FRAME w/ 24"x32" HINGED MANWAY.
FINISH OPTIONS:
❑BLACK INDUSTRIAL ENAMEL
❑ HOT -DIPPED GALVANIZED
�JI
U.L. DETECTOR
CHECK VALVE
;.
GATE VALVE (TYP.)
s" BY-PASS WITH
"
METER & VALVES....
(OPTIONAL)
00 00
'.
GALVANIZED STEEL
SUPPORT (TYP.
6" 12"x12" SUMP WITH
CAST IRON GRATE
L1
PRECAST CONCRETE
VAULT
DUCTILE IRON OR
C-900 STUB -OUT
UNI-FLANGE 2'-0"
(TYP.)
ELEVATION
®Park Bectronic Catalog 1998-1999
Specifications
PROJECT
CONCRETE Class 1 concrete with design strength of
CUSTOMER
4500 PSI at 28 days. Unit is of monolithic
ARCHITECT
construction at floor and first stage of wall
ENGINEER
with sectional riser to required depth.
ORDER # : DATE
REINFORCEMENT: Grade 60 reinforced. Steel rebar conforming to
ASTM A615 on required centers or equal.
STEEL COVER: 1/4" steel skid -resistant floor plate welded
(713) 937-7602
to 3" angle frame with (2) 3"x2-3/8 I beam
®PARKFAXTEL
(713) 937-4254
supports.
EQUIPMENT COMPANY WATS (800) 256-8041
Engineering Data
"Expect the Best"
The backflow assembly sholl be factory assembled in vault & hydrostatically
tested prior to delivery. Field excavation & preparation shall be
4" THRU 10"
complete prior to delivery. Pipe, valves and fittings of the assembly shall
DETECTOR CHECK VALVE ASSEMBLY
be approved by one or more of the following associations:
FM
®
SCALE NONE
DWG. N0.
CITC-1
REV.
DATE
AWWA
1/98
CAPITAL
FIRE PROTECTION, LLC
3350 ROGERDALE SUITE E
HOUSTON, TX 77042 (713)
781-4000
FLOW TEST INFO.
STATIC (psi) = 53
RESIDUAL (psi) = 26
FLOW (gpm) = 1404
CHECKED BY: Scott Cunliffe
APPROVAL:
CITY OF LAPORTE TEXAS
Scott Cunliffe
DRAWN BY:
CONT. NO.:
19-0445
DATE:
4/8/2019
REGISTRATION No.: SCR- 1685889
RME NUMBER: G-1681147
RME: NATHAN W. HENRICK
u,
O
O 0
CD
UG1 00
U �
8 00 OI %
C D - E.
__..
C-900
a
" S.S AMES "IN -BUILDING' sPG
RISER (OR EQUAL). 1'-0' AF PMI I
PMO
u
I I I
AREA OF BEARING FACE
OF CONCRETE THRUST BLOCKS
PIPE
90 DEGREE
45 DEGREE
TEES,PLUGS,CAPS
SIZE
BEND
BEND
AND HYDRANTS
INCHES
SQ.FT.
SQ.FT.
SQ.FT.
4
2
2
2
6
5
3
4
8
8
5
6
10
13
7
9
12
18
10
13
14
25
14
18
16
32
18
23
18
42
22
29
20
51
28
36
24
74
40
52
ING FACE
FACE UNDISTURBED SOIL \--BEARING FACE \-BEARING FACE
90 DEGREE BEND TEE 45 OR 221/2 DEGREE BEND
CONCRETE THRUST BLOCK DETAILS
ROPOSED BUILDING B
210 N. BROADWAY ST
WAREHOUSE AND LAB
D BUILING
I 1 STORY - 19,195 SF I —
- - I PROTECTEDD-PEIR--NF 13 — —
WITH (1) WET AUTOMATIC -
SPRINKLER
DRY ® LOADING DO K.
TOP OF SLAB: 21. 0'
I I I I
I
bT SPRK BELL
I
LOCATION OF BUIL NG
FIRE DEPARTMENT
CONNECTION. REFER t, ;\ i y
TO SPRINKLER PLAN
FOR CONTINUATION.
SCOPE OF WORK:
CAPITAL FIRE PROTECTION TO START CONTRACT AT TS@V FOR
BUILDING "A" AND BUILDING "B" TO SUPPLY WATER FOR THE FIRE
SPRINKLER SYSTEM OF EACH BUILDING PER NFPA 24
SCALE: 1 " = 20'-0"
SPRINKLER SYMBOL LEGEND N
���
BUILDING & SYSTEM LEGEND
GENERAL CONTRACTOR
INFORMATION
ADDITIONAL DESIGN INFORMATION
Symbol
Description
SYMBOL
SPRINK. MANU.
MODEL
FINISH
STYLE
TYPE
P.T.
ORF.
IK-FACTOR
MFG. SIN
TOTAL
0
Hydraulic Reference Points
CONTRACTOR'S NAME
BUILDING OCCUPANCY: ?
Rando Maximos
R
( 46)
Length of Hanger Rod
BUILDING CONSTRUCTION: ?
8-6 7
Elev. Above Finished Floor
CONTACT NAME
Gallant
TYP. TOP OF STRUCTURE:
R
+ (TOS 20-0)
Elev. of Top of Steel
TYPICAL CEILING HEIGHT: ?
10-
Ceiling Height
PHONE NUMBER
832-799-3831
SPRINKLER HEADS CENTER OF TILE: YES ( ) NO ( ) X
�L
Denotes Hanger Location
Halls Do not go Ceiling
NFPA 13 "SMALL ROOM RULE" APPLIED: YES ( ) NO ( ) X
Walls to Ceiling/Roof Deck
NOT TO SCALE
C: \BLK\THRUST.DWG
FAR£
t O
— n '
I U
0
14 0
�1
DATE
REVISIONS
O.S.F.W a'_n" ►nnl
S.S RISER
I.S.F.W
PER PLAN
j SLAB LEVEL
EXT. WALL
-1I1—�—ICI o
:1
.III —III —III —I
P
CONC. FOOTING z
6" S.S RISER "BUILDING A"
8" S.S RISER "BUILDING B"
IN BUILDING RISER
SPIGOT DETAIL
NOT TO SCALE
UNDERGROUND GENERAL NOTES
1. ALL UNDERGROUND PIPING AND MATERIALS TO BE NEW AND INSTALLED PER NFPA
13 & 24, 2013 EDITION AND ALL LOCAL CODE REQUIREMENTS.
2. THRUST BLOCK AND RODDING TO BE INSTALLED PER NFPA 13 & 24, 2013
EDITION.
3. PIPE MINIMUM BURY DEPTH TO TOP OF PIPE TO BE 4'-0".
4. DUCTILE IRON PIPE TO BE USED WHERE PIPING RUNS UNDER BUILDING FOOTING.
5. ALL PIPING TO BE FLUSHED PER NFPA 13 & 24, 2013 EDITION BEFORE
CONNECTION OF OVERHEAD PIPING.
O O O o 0 o O O o 0 0 0 0 0
0 0 o O o 0 0 0 0 0
CITY
COPY
I have reviewed these plans and certify that
they comply with the adopted NFPA standards.
CAPITAL FIRE PROTECTION
3350 RODGERDALE, SUITE E
Houston, TX 77042
(713) 781-4000
SCR # 1685889
RME-Signature:JA
'(
Printed RME Name: _Nathan W. Henrick_
RME# G-1681147 Date:
❑ AS -BUILT [.'SUBMITTAL ❑ OTHER
BUILDING PERMIT APPLICATION #'S
�CE/VED
BLDG B: 19-0000091 APR
BY: D
BY ENrT'EPPRISE MORGAN'S POINT SHEET
1
BLDG B: 1210 N. BROAD WAY ST
La Poste Tom, 77571