HomeMy WebLinkAbout10025 PORTER RD_18-0494___________WPM I q,�;
1
City of La Porte
604 W Fairmont Pkwy
La Porte, Tx 77571
(281)470-5073 INSPECTIONLINE:(281) 470-5130
****BUILDING PERMIT****
---------------------------------------------------------- -----------------
Application Number . . . . . 18-00000494 Date 4/12/18
Property Address . . . . . . 10025 PORTER RD
HCAD Number: 129-636-000-0003
Alternate Search Method:
Application type description FIRE ALARM
Subdivision Name . . . . . . UNDERWOOD BUSINESS PARK
Property Use . . . . . . . . REAL INDUSTRIAL
Property Zoning . . . . . . . PLANNED UNIT DEVELOPMENT
Application valuation . . . . 14000
------------------------------------ -------------------- -----------------
Type of Work
fire alarm
----------------------------------------------------------------------------
1 ul�iL
GRANITA UNDERWOOD DIST CTR LP
% BLACKROCK REALTY ADV INC
11757 KATY FWY STE 250
HOUSTON TX 77079
Contractor
------------------------
PRMM FIRE & ALARM LLC
13727 FM 529
HOUSTON TX 77041
(713) 376-4612
Structure Information 000 000
Construction Type . . . . . NON-COMBUSTIBLE I
Occupancy Type . . . . . . STORAGE
Flood Zone . . . . . . . . ZONE X
----------------------------------------------------------------------------
Permit . . . . . . BLDG PERMIT -FIRE ALARM
Additional desc . . FIRE ALARM
Permit pin number . 562793
Permit Fee . . . . 117.50 Plan Check Fee 58.75
Issue Date . . . . 4/12/18 Valuation . . . . 14000
Expiration Date . . 10/09/18
Qty Unit Charge Per Extension
BASE FEE 20.00
13.00 7.5000 THOU BLDG - 1,001 - 50,000 97.50
----------------------------------------------------------------------------
Special Notes and Comments
March 23, 2018 9:28:58 AM LAPOJLW.
Fire Alarm
1. Call for inspection
2. As per Fire Marshall plan review and
notes
3. This permit is for Fire Alarm
4. Contractor/owner responsible for
removal of all construction debris
5. A building permit (and all its
City of La Porte
604 W Fairmont Pkwy
La Porte, Tx 77571
(281)470-5073
INSPECTION
LINE:(281) 470-5130
****BUILDING PERMIT****
----------------------------------------------------------------------------
Page 2
Application Number . . . . .
18-00000494
Date 4/12/18
----------------------------------------------------------------------------
Special Notes and Comments
applicable sub permits) may
be based on
the remainder of the work to
be done.
HOWEVER, if the work is not
completed
within the allotted time of
the renewal
period, the building permit
(and all
applicable sub permits) must
be applied
for as a NEW permit, and all
permit fees
will be calculated from the
original
permit valuation.
--------------- 7------------------------------------------------------------
Fee summary Charged
----------
Paid
--------------------
Credited Due
----------
-----------------
Permit Fee Total 117.50
117.50
.00 .00
Plan Check Total 58.75
58.75
.00 .00
Grand Total 176.25
176.25
.00 .00
-- -------------- .---------------------------------.
(SIIGNATURE OF Zvi' QTRACTOR OR AUTHORIZED AGENT) DATE
(APPROVED BY BUILDING OFFICIAL OR AUTHORIZED AGENT) DATE
0Ic- 19
City of La Porte Planning &Development Department Phone: 281.470.5073
604 W. Fairmont Pkwy. Fax: 281.470.5005
La Porte, Tx77571 FIRE PERMIT APPLICATION www.laportetx.gov
1. PROJECT INFORMATION: ((�� /n� ' DATE OF SUBMITTAL �•21-LY
PROJECT ADDRESS (If exMng): ILw1S i�Ark�'y'� IK1�22 n
HCAD PARCEL NO j13-digit Taa ID(s): 1.) I O(�•1 - (PJ c0- aoc% 6n U3
2.) 3.)
PROPERTY GALOESCRIPTION:� CI Un�Y�GOJ hui nASS PAY
FIRE ALARM [I FIRE SUPPRESSION QVENT HOOD FIRE SUPPRESSION OUNDERGROUND FIRE LINE
0 ABOVE-0GROUND FIRE SUPPRESSION FIRE SPRINKLER
DESCRIBE WORK: p me Alo-r.--
BUILDING USE: NO. OF STORIES: TOTAL SO. FOOTAGE: PROJECT VALUATION: $ �CL 4�
2. PROPERTY OWNER CONTACT INFORMATION:
OWNER'S NAME: PHONE:
MAILING ADDRESS:
E-MAIL:
3. CONTRACTOR/AGENT: 2R/� wtn, ®'HOMEOWNER IS CONTRACTOR
AGENT/CONTRACTOR COMPANY: 1 �r+t 'nry
PHONE I: 24-k- Voc- IW1 PHONE 2:
E-MAIL Yti rho S! a O r m ;r4 FAX#:
MAIUNGADDRESS: IS1}1 FW\ f;L
CONTACT PERSON'S NAME: n,n I-L rhuSC PHONE: 9,11-N51'"I00-1
4. APPLICATION CHECKLIST & SUPPORTING DOCUMENTATION (Check applicable boxes):
13 T9 � 'If Homeowner is Contractor,
COMPLETE ITEMS 1-4 OF PERMIT APPLICATION must furnish notarized
®SUBMIT TWO(2)COMPLETE SETS'(HARDCOPIES) OFCONSTRUCTION PLANS FOR REVIEW Homestead Affidavit
NOTES TO APPLICANT:
1. CONTRACTOR MUST BE REGISTERED WITH THE CITY
2. TO REGISTER WITH CITY, SUBMIT CURRENT CERTIFICATE OF INSURANCE WITH CITY NAME & ADDRESS AS CERTIFICATE HOLDER
3. NOT A VAUD PERMIT UNTIL OWNER/CONTRACTOR IS NOTIFIED OF APPROVAL AND ALL APPLICABLE FEES ARE PAID IN FULL
APPLICANT PRINTED NAME: TtfL'kw"APPLICANT SIGNATURE: <
(STAFF USE ONLYI:
Occupancy Type: Const.Type: + Flood Zone: � Use Zone (Zoning District): 7 V jJ CE: IV U Taxes: Cr FEES: PERMIT FEE: $ U � PLAN CHECK FEE: $ S S?
Special Conditions: Ifi g-M 124
® Must complete all work and pass City Inspection within 10 days c1 permit Issuance to avoid further Code Enforcement Action
PERMITAPPROVAL: Fire Marshal (Commercial Onl .'. v_ ` •' I -A
te:
Approvedfor Issuance by: qM te:
PERMITN0.
- l�. 4 -19
Fire Alarm
1. Call for inspection
2. As per Fire Marshall plan review and notes
3. This permit is for Fire Alarm
4. Contractor/owner responsible for removal of all construction debris
5. A building permit (and all its applicable sub permits) may be based on the
remainder of the work to be done. HOWEVER, if the work is not completed
within the allotted time of the renewal period, the building permit (and all
applicable sub permits) must be applied for as a NEW permit, and all permit
fees will be calculated from the original permit valuation.
IF THE -"APPROVED PLANS
ARE MODIFIED, A NEW SUBMITTAL
TO TIE CITY IS REQUIRED PRIOR
TO TIE CHANGE OCCURING
uFOE
LA PORTE
Ls 10
FIRE MARSHAL'S
OFFICE
"PLAN REVIEW" Orly
Date
03/15/2017
Business Name
Independence Logistics
Address
10025 Porter Road
Type of Review
Fire Alarm
Contractor
Primm
Reviewed by
Clif Meekins, Fire Marshal
City Permit #
18-0494
Approval
vES
The Applicant Mao be responsible to anon Me design specifications area plans an corm ne area in compliance . Ma regsremenu ..r .orm in m. mra
Intamadonal Fire Code (IFC) and Local Amenam"Irnts as as the applicable referMod
Standards listed In Chapter 45 of the "IS IFC. This plan wiser is not
Intended to be fully Initial. as other requiremmb my be impwed as ""ranted by as Fin Mahal or as deemed neeesaery during onaha Inspections by Me Fin
ManMal's office.
"THIS PLAN REVIEW MUST BE ON THE JOBSITE WITH THE APPROVED SET OF PLANS"
1) A State of Texas licensed Fire Alarm Installer that works for (Primm) must be onsite for ALL Fire
Marshal's inspection and shall be onsite during all phases of installation.
2) Ensure the system is designed and installed so silencing the Audible devices WILL NOT cancel the
Visuals devices through -out the facility. The strobes shall remain active when the system has been
silenced and will remain active until the system has been reset.
3) NFPA 72-13, 26.3.6.6 -Two independent means shall be provided to retransmit an alarm signal to the
designated communications center. One means shall be a dedicated phone line and the second can be a
shared voice line. Phone lines that share data, such as a fax, will not meet this requirement. Cellular
phone/signals are permitted.
4) The Fire Marshal's Office must witness a function test of the Fire Alarm system. Contact the Fire
Marshal's Office 24hrs in advance to schedule a Fire Alarm system test.
5) Approved (Stamped) copy of the Fire Alarm plans shall be on the job site and available to the Fire
Marshal Inspector at any time during installation.
125 South 31 Street, La Porte, TX 77571 is Office: 281-867-4603 * Fax: 281-867-4629
199
ADDRESS:
OWNER'S NAME:
PROJECT TYPE:
HCAD#:
COMMERCIAL '
PLAN REVIEW COVER SHEET
25-
_NEW:_ ADDN:
WE LOC#:
FLOOD ZONE: USE ZONE:
YIN SUB /DATE RETURNED
TIRZ ZONE?
SITE VISIT (DRAINAGE)
ZONING PERMIT
CERT. SITE PLAN APPROVAL
ASBESTOS SURVEY RECEIVED
TAS (ADA) PROOF OF SUBMITTAL
F101 RESOL. APPLICABLE?:
F216-00-00 RESOL. APPLICABLE?:
FILL DIRT APPL/PERMIT
CLEARING PERMIT NEEDED?
FLOOD PERMIT NEEDED?:
W/S FEES APPLICABLE?:
100% MASONRY/GLASS
STORM WATER QUALITY PERMIT
TAXES UP TO DATE?:
DATE OF REVIEW:
ITEMS NEEDED FOR ISSUANCE OF PERMIT:
1. CURRENT INSURANCE CERT. (if applicable)
lV\- C� V/J w Vqj
(Applicable on Demo, Addn, or Remodel)
(Applicable to Comm. Or Ind.)
(If yes, permit cannot be issued.)
(If yes, permit cannot be issued.)
(If yes, figure fees. If no, use w/s farm to
explain why they are not.)
INSPECTOR: LIAvte.i
OK
OWNER OR CONTRACTOR NOTIFICATION
DATE TIME NAME OF PERSON CONTACTED
3--4- if PF 4-c ) Vl'16
3-�21 ` a kry j F k a apP ro v/wA
S:1CPSh=\INSPECCION DIVISIONInspecti0MkCONE PLAN REVIEW COVER SHEET.dw Rev. FEB2012
p.,i.,zizoraa::z.zlan�cut nLn .. : :.
File Edd Connends Help
property Description inquiry
Location ID:
HCAD Number:
Alternate Search Method:
Location address;
Piirriary related party:
BUSINESS
J nn
X �w.
Cant^J
Melded
Reli Carty dnla
?. `s 0 l'
46938
129-636-000-0003
10025 PORTER RD CLP
GRANITA UNDEERNIOOD DIST CTR LP
840Z 0 Z H I1
... t_-
T"�
a d
NOTIFICATION
CIRCUIT
POWER
SUPPLY
■0
El
14
ONE LINE RISER
O
o"-)- N-d FIRE
ALARM
CONTROL
ADDRESSABLE CIRCUIT
0--`
x,
'; .
COMMUNICATIONS PATH AND
MEANS SHALL SATISFY THE
REQUIREMENTS OF NFPA 72 26.6,
IFC 907.6.5
120 VAC DEDICATED BRANCH CIRCUIT BY
OTHERS.
CQ EQUIPMENT LEGEND
Sequence of Operation
Upon activation of any single initiating appliance, smoke detector, water flow or manual
SYSTEM SMOKE DETECTOR
pull station, the system, without delay, will enter into a general alarm condition. All
E-
audible and visual indicating appliances will be activated. Sprinkler valve tamper shall -�
cause a supervisory condition. All off -normal and return to normal conditions shall be
"`'
MANUAL PULL STATION
transmitted per 907.6.5 (amended) to an UL approved central monitoring facility.
......__...._.._..._
o
System Notes;
System shall be an intelligent addressable fire alarm system control. Primary and
HORN STROBE Wall mount
secondary power shall be provided in accordance with NFPA 72 Chapter 10. Remote
co
station monitoring communications shall satisfy the requirements of Chapter 26.6 and
IFC 907.6.7. All supplied cable shall be listed for fire limited use and
°
STROBE ONLY Ceiling mount
CQ
power plenum
_ ,
where required. Ail system components shall be UL listed for the purpose intended.
While certain specific sections are mentioned for clarification, this systems' design
shall meet ALL applicable currently adopted standards of NFPA, ANSI, and ICC. Any
"''
HORN STROBE Ceiling mount
missing or unknown items and shall be published in the required closing record
t
z
o
documentation.
Minimum Design Standards;
ADDRESSABLE MONITOR MODULE
A
Shall include but not limited to minimum standards adopted by the State of Texas per
a
40 TAC H 34.607 or local jurisdictions adopted standards if greater in either year or
a
scope.
CABLE, 18AWG, 2C FPL
co
Mechanical System Notes;
All Duct smoke detectors if provided by others Shall be connected and monitored by77,
CABLE 16 A WG 2C FPL
the FRCP. Duct detector alarm shall cause a supervisory condition and shut down the
,
attached unit per NFPA 90A and IMC 606.2. Field verify quantity and location of
mechanical devices.
FIRE ALARM CONTROL PANEL
co
W
A
FA
O
E
REMOTE NAC POWER SUPPLY(S)
E
z
W
O
VALVE TAMPER SWITCH BY OTHERS
A
z
�a
WATERFLOW SWITCH BY OTHERS
�M
�� c
HAR 2 � 2018
X FOR SUBMITTAL ❑ RECORD DRAWINGS
I have reviewed these nlans and
Xcertity that they compry with the applicable codes
and standards;
❑ Or
tify they were copied from sealed engineering
plan and any violption of the apphcabTe odes or
stan ards are specrtrcal�y noted on these pans.
PRMM Fire & Alarm LLC
13727 FM 529
Houston, TX 77041
281.858.1007 ACR-1807672
PS-17435 5
APS Licers�atnr License
Anthony R. Mitchell 5 March, 2018
APS Printed Name Date
i
i
9 q
IQ o
................................................................................................ .
AC
® Y
75cd Weather resistant.
5 1
Water flow only,
Fie!d verify quantity and locations.
non-silenceable.
FDC°
P5 1.3 PS 1.1
'-'177cd
,
TS
.....................
C
LIGHT
ASSEMBLY
AC
125 gib,
WB
WB
AC
C
C,
i
3
x
a
OFFICE OFFICE OFFICE
104 1 1 105 1 1 106
J
Jr`
OPEN 15cd
OFFICE
112
115cd
0
Eml
1F
1
SHARED
OFFICE
107 •, 5
30cd
l
1cd
STORAGE
GYM 102
108 PS 2.
15cd`..
15cd
75cd
II 3
TRUE NORTH
iFQ
1-7-7
VV\ l%[% ✓LVI\ LJ 1
TENANT (TYP)
177
77cd
PS 2.6
77cd
'-'\ '= r 1.O # ... . .. ...1 _ ......A N
r
....
SCALE: 3/32" = V-0"
_.. 0 i• 2` J`Y S'b' 7'W
177cd
177cd
177cd
177cd
A
cd
BULK STORAGE
AREA
C
G
'I
'i
X FOR SUBMITTAL EfRECORD DRAWINGS
I have reviewed these plans and
X certify that they comply with the applicable codes
and standards;
Or certify they were copied from sealed en *ineering
plans and any viol4,tvlon of the appllcab e odes or
standards are specttical y noted bn these pans.
PRMM Fire & Alarm LLC
13727 FM 529
Houston, TX 77041
2 81.85 8.1007 ACR-1807672
PS-1743565
APS Liceng�gatur6License
Anthony R. Mitchell 5 March, 2018
APS.Printed Name Date
c�
z �
00
(n 0-I
w O
F- -7
Q iri
0 M
o Q
z
(� L,J 0
DRAWING NO.
F
9
0-1
w
Sequence of Operation
Upon activation of any single initiating appliance, smoke detector, water flow or manual
pull station, the system, without delay, will enter into a general alarm condition. All
audible and visual indicating appliances will be activated. Sprinkler valve tamper shall
cause a supervisory condition. All off -normal and return to normal conditions shall be
transmitted per 907.6.5 (amended) to an UL approved central monitoring facility.
System Notes;
System shall be an intelligent addressable fire alarm system control. Primary and
secondary power shall be provided in accordance with NFPA 72 Chapter 10. Remote
station monitoring communications shall satisfy the requirements of Chapter 26.6 and
IFC 907.6.7. All supplied cable shall be listed for fire power limited use and plenum
where required. All system components shall be UL listed for the purpose intended.
While certain specific sections are mentioned for clarification, this systems' design
shall meet ALL applicable currently adopted standards of NFPA, ANSI, and ICC. Any
missing or unknown items and shall be published in the required closing record
documentation.
Minimum Design Standards;
Shall include but not limited to minimum standards adopted by the State of Texas per
40 TAC H 34.607 or local jurisdictions adopted standards if greater in either year or
scope.
Mechanical System Notes;
All Duct smoke detectors if provided by others Shall be connected and monitored by
the FACP. Duct detector alarm shall cause a supervisory condition and shut down the
attached unit per NFPA 90A and IMC 606.2. Field verify quantity and location of
mechanical devices.
ONE LINE RISER
ADDRESSABLE CIRCUIT
43Y r--" T
COMMUNICATIONS PATH AND
MEANS SHALL SATISFY THE
REQUIREMENTS OF NFPA 72 26.6,
IFC 907.6.5
��.. VAC DEDICATED BRANCH CIRCUIT BY
OTHERS.
EQUIPMENT LEGEND
e
SYSTEM SMOKE DETECTOR
MANUAL PULL STATION
HORN STROBE Wall mount
STROBE ONLY Ceiling mount
HORN STROBE Ceiling mount
ADDRESSABLE MONITOR MODULE
CABLE, 18AWG, 2C FPL
CABLE, 16 A WG, 2 C FPL
FIRE ALARM CONTROL PANEL
REMOTE NAC POWER SUPPLY(5)
VALVE TAMPER SWITCH BY OTHERS
WATERFLOW SWITCH BY OTHERS
N FOR SUBMITTAL ❑ RECORD DRAWINGS
t have reviewed these plans and
X certify that they compry with the applicable codes
and standards;
Or
certify they were copied from sealed en meering
plan and any violptfion of the appplicable odes or
standsards are specitical y noted bn these pans.
PRMM Fire & Alarm LLC
13727 FM 529
Houston, TX 77041
2 81.85 8.1007 ACR-1807672
'
— ; 3: g I //'V�-p-174 S5
356
APS Licer ,i ah�"—L,icense #
Anthony R. Mitchell 5 March, 2018
APS Printed Name Date
U
............_...................................................................................
R W f9' ®
AC
( ® X, 0
75cd Weather resistant.
Water flow only,
S-t
Field verify gaar,tity and locations.
non-silenceable.
FDC
PS 1.3.. PS 1.1
''-1,77cd ,
TSI
C
iC
LIGHT
ASSEMBLY
AC
...................
WB
WB
AC
C
177cd
co
co
0
10
0
CQ
m
0
CQ
U
i�
Qi
lf�
z
0
A
a
a
a
rn
0
No
115cd
Ia
10
TRUE NORTH
IF FC
11
IF.Q
UWAM
vvvi\r\ vwrn v i
TENANT (TYP)
177
77rrl
PS 2.6
77cd
ALARM
PLAN
.... .
_. SCALE: 3/32" = V-0" a r r 31 .- T (1- ,- W
177cd
177cd
177cd
177cd
cd
BULK STORAGE
AREA
C
X FOR SUBMITTAL ❑ RECORD DRAWINGS
i
j I have reviewed these plans and
X certify that they comply with the applicable codes
and sttandards;
❑ certify they were copied from sealed engineering
Ian$$ at�d an viol hog of the a licabTe odes or
sptandards are specifica�llsy no on these pans.
PRMM Fire & Alarm LLC
13727 FM 529
Houston, TX 77041
281.858.1007 ACR-1807672
; 3: g;; �' - -
P S -1745 3 65
APS Licerfss�atur� } License
Anthony R. Mitchell 5 March, 2018
APS Printed Name Date
DRAWING NO.
F—IoO
ej