Loading...
HomeMy WebLinkAbout10025 PORTER RD_18-0494___________WPM I q,�; 1 City of La Porte 604 W Fairmont Pkwy La Porte, Tx 77571 (281)470-5073 INSPECTIONLINE:(281) 470-5130 ****BUILDING PERMIT**** ---------------------------------------------------------- ----------------- Application Number . . . . . 18-00000494 Date 4/12/18 Property Address . . . . . . 10025 PORTER RD HCAD Number: 129-636-000-0003 Alternate Search Method: Application type description FIRE ALARM Subdivision Name . . . . . . UNDERWOOD BUSINESS PARK Property Use . . . . . . . . REAL INDUSTRIAL Property Zoning . . . . . . . PLANNED UNIT DEVELOPMENT Application valuation . . . . 14000 ------------------------------------ -------------------- ----------------- Type of Work fire alarm ---------------------------------------------------------------------------- 1 ul�iL GRANITA UNDERWOOD DIST CTR LP % BLACKROCK REALTY ADV INC 11757 KATY FWY STE 250 HOUSTON TX 77079 Contractor ------------------------ PRMM FIRE & ALARM LLC 13727 FM 529 HOUSTON TX 77041 (713) 376-4612 Structure Information 000 000 Construction Type . . . . . NON-COMBUSTIBLE I Occupancy Type . . . . . . STORAGE Flood Zone . . . . . . . . ZONE X ---------------------------------------------------------------------------- Permit . . . . . . BLDG PERMIT -FIRE ALARM Additional desc . . FIRE ALARM Permit pin number . 562793 Permit Fee . . . . 117.50 Plan Check Fee 58.75 Issue Date . . . . 4/12/18 Valuation . . . . 14000 Expiration Date . . 10/09/18 Qty Unit Charge Per Extension BASE FEE 20.00 13.00 7.5000 THOU BLDG - 1,001 - 50,000 97.50 ---------------------------------------------------------------------------- Special Notes and Comments March 23, 2018 9:28:58 AM LAPOJLW. Fire Alarm 1. Call for inspection 2. As per Fire Marshall plan review and notes 3. This permit is for Fire Alarm 4. Contractor/owner responsible for removal of all construction debris 5. A building permit (and all its City of La Porte 604 W Fairmont Pkwy La Porte, Tx 77571 (281)470-5073 INSPECTION LINE:(281) 470-5130 ****BUILDING PERMIT**** ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 18-00000494 Date 4/12/18 ---------------------------------------------------------------------------- Special Notes and Comments applicable sub permits) may be based on the remainder of the work to be done. HOWEVER, if the work is not completed within the allotted time of the renewal period, the building permit (and all applicable sub permits) must be applied for as a NEW permit, and all permit fees will be calculated from the original permit valuation. --------------- 7------------------------------------------------------------ Fee summary Charged ---------- Paid -------------------- Credited Due ---------- ----------------- Permit Fee Total 117.50 117.50 .00 .00 Plan Check Total 58.75 58.75 .00 .00 Grand Total 176.25 176.25 .00 .00 -- -------------- .---------------------------------. (SIIGNATURE OF Zvi' QTRACTOR OR AUTHORIZED AGENT) DATE (APPROVED BY BUILDING OFFICIAL OR AUTHORIZED AGENT) DATE 0Ic- 19 City of La Porte Planning &Development Department Phone: 281.470.5073 604 W. Fairmont Pkwy. Fax: 281.470.5005 La Porte, Tx77571 FIRE PERMIT APPLICATION www.laportetx.gov 1. PROJECT INFORMATION: ((�� /n� ' DATE OF SUBMITTAL �•21-LY PROJECT ADDRESS (If exMng): ILw1S i�Ark�'y'� IK1�22 n HCAD PARCEL NO j13-digit Taa ID(s): 1.) I O(�•1 - (PJ c0- aoc% 6n U3 2.) 3.) PROPERTY GALOESCRIPTION:� CI Un�Y�GOJ hui nASS PAY FIRE ALARM [I FIRE SUPPRESSION QVENT HOOD FIRE SUPPRESSION OUNDERGROUND FIRE LINE 0 ABOVE-0GROUND FIRE SUPPRESSION FIRE SPRINKLER DESCRIBE WORK: p me Alo-r.-- BUILDING USE: NO. OF STORIES: TOTAL SO. FOOTAGE: PROJECT VALUATION: $ �CL 4� 2. PROPERTY OWNER CONTACT INFORMATION: OWNER'S NAME: PHONE: MAILING ADDRESS: E-MAIL: 3. CONTRACTOR/AGENT: 2R/� wtn, ®'HOMEOWNER IS CONTRACTOR AGENT/CONTRACTOR COMPANY: 1 �r+t 'nry PHONE I: 24-k- Voc- IW1 PHONE 2: E-MAIL Yti rho S! a O r m ;r4 FAX#: MAIUNGADDRESS: IS1}1 FW\ f;L CONTACT PERSON'S NAME: n,n I-L rhuSC PHONE: 9,11-N51'"I00-1 4. APPLICATION CHECKLIST & SUPPORTING DOCUMENTATION (Check applicable boxes): 13 T9 � 'If Homeowner is Contractor, COMPLETE ITEMS 1-4 OF PERMIT APPLICATION must furnish notarized ®SUBMIT TWO(2)COMPLETE SETS'(HARDCOPIES) OFCONSTRUCTION PLANS FOR REVIEW Homestead Affidavit NOTES TO APPLICANT: 1. CONTRACTOR MUST BE REGISTERED WITH THE CITY 2. TO REGISTER WITH CITY, SUBMIT CURRENT CERTIFICATE OF INSURANCE WITH CITY NAME & ADDRESS AS CERTIFICATE HOLDER 3. NOT A VAUD PERMIT UNTIL OWNER/CONTRACTOR IS NOTIFIED OF APPROVAL AND ALL APPLICABLE FEES ARE PAID IN FULL APPLICANT PRINTED NAME: TtfL'kw"APPLICANT SIGNATURE: < (STAFF USE ONLYI: Occupancy Type: Const.Type: + Flood Zone: � Use Zone (Zoning District): 7 V jJ CE: IV U Taxes: Cr FEES: PERMIT FEE: $ U � PLAN CHECK FEE: $ S S? Special Conditions: Ifi g-M 124 ® Must complete all work and pass City Inspection within 10 days c1 permit Issuance to avoid further Code Enforcement Action PERMITAPPROVAL: Fire Marshal (Commercial Onl .'. v_ ` •' I -A te: Approvedfor Issuance by: qM te: PERMITN0. - l�. 4 -19 Fire Alarm 1. Call for inspection 2. As per Fire Marshall plan review and notes 3. This permit is for Fire Alarm 4. Contractor/owner responsible for removal of all construction debris 5. A building permit (and all its applicable sub permits) may be based on the remainder of the work to be done. HOWEVER, if the work is not completed within the allotted time of the renewal period, the building permit (and all applicable sub permits) must be applied for as a NEW permit, and all permit fees will be calculated from the original permit valuation. IF THE -"APPROVED PLANS ARE MODIFIED, A NEW SUBMITTAL TO TIE CITY IS REQUIRED PRIOR TO TIE CHANGE OCCURING uFOE LA PORTE Ls 10 FIRE MARSHAL'S OFFICE "PLAN REVIEW" Orly Date 03/15/2017 Business Name Independence Logistics Address 10025 Porter Road Type of Review Fire Alarm Contractor Primm Reviewed by Clif Meekins, Fire Marshal City Permit # 18-0494 Approval vES The Applicant Mao be responsible to anon Me design specifications area plans an corm ne area in compliance . Ma regsremenu ..r .orm in m. mra Intamadonal Fire Code (IFC) and Local Amenam"Irnts as as the applicable referMod Standards listed In Chapter 45 of the "IS IFC. This plan wiser is not Intended to be fully Initial. as other requiremmb my be impwed as ""ranted by as Fin Mahal or as deemed neeesaery during onaha Inspections by Me Fin ManMal's office. "THIS PLAN REVIEW MUST BE ON THE JOBSITE WITH THE APPROVED SET OF PLANS" 1) A State of Texas licensed Fire Alarm Installer that works for (Primm) must be onsite for ALL Fire Marshal's inspection and shall be onsite during all phases of installation. 2) Ensure the system is designed and installed so silencing the Audible devices WILL NOT cancel the Visuals devices through -out the facility. The strobes shall remain active when the system has been silenced and will remain active until the system has been reset. 3) NFPA 72-13, 26.3.6.6 -Two independent means shall be provided to retransmit an alarm signal to the designated communications center. One means shall be a dedicated phone line and the second can be a shared voice line. Phone lines that share data, such as a fax, will not meet this requirement. Cellular phone/signals are permitted. 4) The Fire Marshal's Office must witness a function test of the Fire Alarm system. Contact the Fire Marshal's Office 24hrs in advance to schedule a Fire Alarm system test. 5) Approved (Stamped) copy of the Fire Alarm plans shall be on the job site and available to the Fire Marshal Inspector at any time during installation. 125 South 31 Street, La Porte, TX 77571 is Office: 281-867-4603 * Fax: 281-867-4629 199 ADDRESS: OWNER'S NAME: PROJECT TYPE: HCAD#: COMMERCIAL ' PLAN REVIEW COVER SHEET 25- _NEW:_ ADDN: WE LOC#: FLOOD ZONE: USE ZONE: YIN SUB /DATE RETURNED TIRZ ZONE? SITE VISIT (DRAINAGE) ZONING PERMIT CERT. SITE PLAN APPROVAL ASBESTOS SURVEY RECEIVED TAS (ADA) PROOF OF SUBMITTAL F101 RESOL. APPLICABLE?: F216-00-00 RESOL. APPLICABLE?: FILL DIRT APPL/PERMIT CLEARING PERMIT NEEDED? FLOOD PERMIT NEEDED?: W/S FEES APPLICABLE?: 100% MASONRY/GLASS STORM WATER QUALITY PERMIT TAXES UP TO DATE?: DATE OF REVIEW: ITEMS NEEDED FOR ISSUANCE OF PERMIT: 1. CURRENT INSURANCE CERT. (if applicable) lV\- C� V/J w Vqj (Applicable on Demo, Addn, or Remodel) (Applicable to Comm. Or Ind.) (If yes, permit cannot be issued.) (If yes, permit cannot be issued.) (If yes, figure fees. If no, use w/s farm to explain why they are not.) INSPECTOR: LIAvte.i OK OWNER OR CONTRACTOR NOTIFICATION DATE TIME NAME OF PERSON CONTACTED 3--4- if PF 4-c ) Vl'16 3-�21 ` a kry j F k a apP ro v/wA S:1CPSh=\INSPECCION DIVISIONInspecti0MkCONE PLAN REVIEW COVER SHEET.dw Rev. FEB2012 p.,i.,zizoraa::z.zlan�cut nLn .. : :. File Edd Connends Help property Description inquiry Location ID: HCAD Number: Alternate Search Method: Location address; Piirriary related party: BUSINESS J nn X �w. Cant^J Melded Reli Carty dnla ?. `s 0 l' 46938 129-636-000-0003 10025 PORTER RD CLP GRANITA UNDEERNIOOD DIST CTR LP 840Z 0 Z H I1 ... t_- T"� a d NOTIFICATION CIRCUIT POWER SUPPLY ■0 El 14 ONE LINE RISER O o"-)- N-d FIRE ALARM CONTROL ADDRESSABLE CIRCUIT 0--` x, '; . COMMUNICATIONS PATH AND MEANS SHALL SATISFY THE REQUIREMENTS OF NFPA 72 26.6, IFC 907.6.5 120 VAC DEDICATED BRANCH CIRCUIT BY OTHERS. CQ EQUIPMENT LEGEND Sequence of Operation Upon activation of any single initiating appliance, smoke detector, water flow or manual SYSTEM SMOKE DETECTOR pull station, the system, without delay, will enter into a general alarm condition. All E- audible and visual indicating appliances will be activated. Sprinkler valve tamper shall -� cause a supervisory condition. All off -normal and return to normal conditions shall be "`' MANUAL PULL STATION transmitted per 907.6.5 (amended) to an UL approved central monitoring facility. ......__...._.._..._ o System Notes; System shall be an intelligent addressable fire alarm system control. Primary and HORN STROBE Wall mount secondary power shall be provided in accordance with NFPA 72 Chapter 10. Remote co station monitoring communications shall satisfy the requirements of Chapter 26.6 and IFC 907.6.7. All supplied cable shall be listed for fire limited use and ° STROBE ONLY Ceiling mount CQ power plenum _ , where required. Ail system components shall be UL listed for the purpose intended. While certain specific sections are mentioned for clarification, this systems' design shall meet ALL applicable currently adopted standards of NFPA, ANSI, and ICC. Any "'' HORN STROBE Ceiling mount missing or unknown items and shall be published in the required closing record t z o documentation. Minimum Design Standards; ADDRESSABLE MONITOR MODULE A Shall include but not limited to minimum standards adopted by the State of Texas per a 40 TAC H 34.607 or local jurisdictions adopted standards if greater in either year or a scope. CABLE, 18AWG, 2C FPL co Mechanical System Notes; All Duct smoke detectors if provided by others Shall be connected and monitored by77, CABLE 16 A WG 2C FPL the FRCP. Duct detector alarm shall cause a supervisory condition and shut down the , attached unit per NFPA 90A and IMC 606.2. Field verify quantity and location of mechanical devices. FIRE ALARM CONTROL PANEL co W A FA O E REMOTE NAC POWER SUPPLY(S) E z W O VALVE TAMPER SWITCH BY OTHERS A z �a WATERFLOW SWITCH BY OTHERS �M �� c HAR 2 � 2018 X FOR SUBMITTAL ❑ RECORD DRAWINGS I have reviewed these nlans and Xcertity that they compry with the applicable codes and standards; ❑ Or tify they were copied from sealed engineering plan and any violption of the apphcabTe odes or stan ards are specrtrcal�y noted on these pans. PRMM Fire & Alarm LLC 13727 FM 529 Houston, TX 77041 281.858.1007 ACR-1807672 PS-17435 5 APS Licers�atnr License Anthony R. Mitchell 5 March, 2018 APS Printed Name Date i i 9 q IQ o ................................................................................................ . AC ® Y 75cd Weather resistant. 5 1 Water flow only, Fie!d verify quantity and locations. non-silenceable. FDC° P5 1.3 PS 1.1 '-'177cd , TS ..................... C LIGHT ASSEMBLY AC 125 gib, WB WB AC C C, i 3 x a OFFICE OFFICE OFFICE 104 1 1 105 1 1 106 J Jr` OPEN 15cd OFFICE 112 115cd 0 Eml 1F 1 SHARED OFFICE 107 •, 5 30cd l 1cd STORAGE GYM 102 108 PS 2. 15cd`.. 15cd 75cd II 3 TRUE NORTH iFQ 1-7-7 VV\ l%[% ✓LVI\ LJ 1 TENANT (TYP) 177 77cd PS 2.6 77cd ­'­-'\ '= r 1.O # ... . .. ...1 _ ......A N r .... SCALE: 3/32" = V-0" _.. 0 i• 2` J`Y S'b' 7'W 177cd 177cd 177cd 177cd A cd BULK STORAGE AREA C G 'I 'i X FOR SUBMITTAL EfRECORD DRAWINGS I have reviewed these plans and X certify that they comply with the applicable codes and standards; Or certify they were copied from sealed en *ineering plans and any viol4,tvlon of the appllcab e odes or standards are specttical y noted bn these pans. PRMM Fire & Alarm LLC 13727 FM 529 Houston, TX 77041 2 81.85 8.1007 ACR-1807672 PS-1743565 APS Liceng�gatur6License Anthony R. Mitchell 5 March, 2018 APS.Printed Name Date c� z � 00 (n 0-I w O F- -7 Q iri 0 M o Q z (� L,J 0 DRAWING NO. F 9 0-1 w Sequence of Operation Upon activation of any single initiating appliance, smoke detector, water flow or manual pull station, the system, without delay, will enter into a general alarm condition. All audible and visual indicating appliances will be activated. Sprinkler valve tamper shall cause a supervisory condition. All off -normal and return to normal conditions shall be transmitted per 907.6.5 (amended) to an UL approved central monitoring facility. System Notes; System shall be an intelligent addressable fire alarm system control. Primary and secondary power shall be provided in accordance with NFPA 72 Chapter 10. Remote station monitoring communications shall satisfy the requirements of Chapter 26.6 and IFC 907.6.7. All supplied cable shall be listed for fire power limited use and plenum where required. All system components shall be UL listed for the purpose intended. While certain specific sections are mentioned for clarification, this systems' design shall meet ALL applicable currently adopted standards of NFPA, ANSI, and ICC. Any missing or unknown items and shall be published in the required closing record documentation. Minimum Design Standards; Shall include but not limited to minimum standards adopted by the State of Texas per 40 TAC H 34.607 or local jurisdictions adopted standards if greater in either year or scope. Mechanical System Notes; All Duct smoke detectors if provided by others Shall be connected and monitored by the FACP. Duct detector alarm shall cause a supervisory condition and shut down the attached unit per NFPA 90A and IMC 606.2. Field verify quantity and location of mechanical devices. ONE LINE RISER ADDRESSABLE CIRCUIT 43Y r--" T COMMUNICATIONS PATH AND MEANS SHALL SATISFY THE REQUIREMENTS OF NFPA 72 26.6, IFC 907.6.5 ��.. VAC DEDICATED BRANCH CIRCUIT BY OTHERS. EQUIPMENT LEGEND e SYSTEM SMOKE DETECTOR MANUAL PULL STATION HORN STROBE Wall mount STROBE ONLY Ceiling mount HORN STROBE Ceiling mount ADDRESSABLE MONITOR MODULE CABLE, 18AWG, 2C FPL CABLE, 16 A WG, 2 C FPL FIRE ALARM CONTROL PANEL REMOTE NAC POWER SUPPLY(5) VALVE TAMPER SWITCH BY OTHERS WATERFLOW SWITCH BY OTHERS N FOR SUBMITTAL ❑ RECORD DRAWINGS t have reviewed these plans and X certify that they compry with the applicable codes and standards; Or certify they were copied from sealed en meering plan and any violptfion of the appplicable odes or standsards are specitical y noted bn these pans. PRMM Fire & Alarm LLC 13727 FM 529 Houston, TX 77041 2 81.85 8.1007 ACR-1807672 ' — ; 3: g I //'V�-p-174 S5 356 APS Licer ,i ah�"—L,icense # Anthony R. Mitchell 5 March, 2018 APS Printed Name Date U ............_................................................................................... R W f9' ® AC ( ® X, 0 75cd Weather resistant. Water flow only, S-t Field verify gaar,tity and locations. non-silenceable. FDC PS 1.3.. PS 1.1 ''-1,77cd , TSI C iC LIGHT ASSEMBLY AC ................... WB WB AC C 177cd co co 0 10 0 CQ m 0 CQ U i� Qi lf� z 0 A a a a rn 0 No 115cd Ia 10 TRUE NORTH IF FC 11 IF.Q UWAM vvvi\r\ vwrn v i TENANT (TYP) 177 77rrl PS 2.6 77cd ALARM PLAN .... . _. SCALE: 3/32" = V-0" a r r 31 .- T (1- ,- W 177cd 177cd 177cd 177cd cd BULK STORAGE AREA C X FOR SUBMITTAL ❑ RECORD DRAWINGS i j I have reviewed these plans and X certify that they comply with the applicable codes and sttandards; ❑ certify they were copied from sealed engineering Ian$$ at�d an viol hog of the a licabTe odes or sptandards are specifica�llsy no on these pans. PRMM Fire & Alarm LLC 13727 FM 529 Houston, TX 77041 281.858.1007 ACR-1807672 ; 3: g;; �' - - P S -1745 3 65 APS Licerfss�atur� } License Anthony R. Mitchell 5 March, 2018 APS Printed Name Date DRAWING NO. F—IoO ej