Loading...
HomeMy WebLinkAbout212 W MAIN ST_14-0262___________212 WEST MAIN 212 W. MAIN 5T. INTERIOR REMODEL CAFFEY BROTHERS BILLIARDS &PUB CAFFEY BROTHERS BILLIARDS PUB & 212 WEST MAIN 212 W. MAIN ST. CAFFEY BROTHERS BIL Zi iT G Y, Z C a, REQUEST FOR CITY COUNCIL AGENDA ITEM Agenda Date Requested: October 24, 2011 Requested By: Councilman Zemanek Department: N/A Report: _Resolution: _Ordinance: _ Exhibit: Utility Map Exhibit: Appropriation Source of Funds: N.A. Account Number: N.A. Amount Budgeted: N.A. Amount Requested: N.A. Budgeted Item: _YES _NO SUMMARY At the request of Councilman Zemanek, this item was placed on the agenda to discuss proposed infrastructure improvements to facilitate economic development. The catalyst for the discussion was the request from the property owner of 212 W. Main, who approached the City to discuss options for the renovation of the building into a pool hall. The proposed renovation would bring substantial capital investment and other benefits to the City. The current infrastructure serving the building does not support the required sprinkler system. Typically, this kind of improvement would be paid for through the standard utility fee charged for new development. Since this is an existing building, the proposed renovation and required utility upsize doesn't fit neatly into the City's traditional funding structure for infrastructure upgrades for development. In the past, the City had a capital improvement project in the Utility Fund that provided funds for this type of improvement associated with development. That project was eliminated from the budget in FY 2010. The City had tentatively agreed to provide labor to install a larger sized water line and the developer would provide the materials cost. The total cost of the utility upsize is approximately $7,500, with the developer funding the lion share of the amount for materials. The City portion was proposed to be an "in -kind" contribution for the labor. Staff would like direction from Council regarding future requests for infrastructure improvements that facilitate development. Action Required by Council: None. Approved for City Council Agenda Traci E. Leach, Assistant City Manager Date '$ 93 R r 1 o LOCATION OF PROJECTy ♦ r t �k Replacing existing 330' of 3" waterline w/ 6 ME Bar <- t m . 146 _ 1\ Ll r - �• a ,_4 •' deb b '� 1 JJ S i. - j.• ' Wilmore, Debbie From: Wilmore, Debbie Sent: Wednesday, October 12, 2011 6:01 PM To: Osborne, Stacey Cc: Leach, Traci; Mick, David; Huber, Mark; Menager, Dwayne Subject: FW: mark caffey update Attachments: 200 Main 6 INCH WATER LINE UPGRADE.doc Stacey —thanks for the updatel Mark/Dwayne — fyi From: Osborne, Stacey Sent: Wednesday, October 12, 2011 5:36 PM To: Wilmore, Debbie; Mick, David Cc: Leach, Traci Subject: mark caffey update Debbie and Dave, I want to let you know the latest with Mark Caffey's billiards room that he's trying to build on Main Street. This morning we talked with him about approaching the EDC Board for a grant to help pay the materials and construction costs for the 6-inch water line upgrade to his property at 212 West Main, in the amount of roughly $7500. Mark seemed to want to move forward with this at our meeting, but he called me later this morning and said that he's now thinking that he and his brother would be willing to just pay the $7500 to the City so that the project can move forward. Instead of a grant from the EDC, they are now thinking that they would prefer to ask the City for a tax abatement for the first couple of years of business, which we're willing to present to Council, but which will obviously not affect this particular issue. So ... I sent him the cost estimate, which I've attached here for your reference, and told him to let me know what he wants to do. I will keep you posted. If he does indeed decide to go ahead and pay for it, I'll work with you, Dave, to figure out the best way to make that happen logistically.. Just wanted to keep you in the loop... Thanks, Stacey Stacey F. Osborne Economic Development Coordinator City of La Porte 604 W. Fairmont Parkway La Porte, TX 77571 www.laportetx.Koy 281-470-5017 office 281-639-4617 mobile NVIA114:»I:14 LABOR MATERIALS CONSTRUCTION ESTIMATE FOR 6 INCH WATER LINE UPGRADE 212 W. MAIN 6/3/I1 $ 2355.00 $ 4000.00 TOTAL $ 6355.00 CHIP SEAL REPAIR LABOR $ 336.00 MATERIALS $ 866.00 TOTAL $ 1,202.00 GRAND TOTAL $ 7557.00 NOTES: Grid Sheet Location ry' Water Distribution System Legend Gate Valve of Gate Valve (Open L) * Gate Valve (Open R) a Gate Valve (Abandoned) • Flush Valve Air Release Valve Hydrant Lateral ¢ Fire Hydrant — Water Main — LPAWA Main - Drainage + Rail Lines ®City Limits Q Industrial District of n0 Utilities F A Mapping Project: Water •+� - Distribution 6 WFWl ,Pm "•ro Pma T.Y99591 181410.5039 FMICLAUNCH & MILLER Fsg� Caeuluaa xrw.chWmilbam Soo: 1' • NO Grid Sheet: oil - e W: Oc M. A00 oene9 aT aon l sw CD O O a ll Z_ N _O N NOTES: Grid Sheet Location Water Distribution System Legend Gate Valve • Gate Valve (Open L) • Gate Valve (Open R) • Gate Valve (Abandoned) • Flush Valve e Air Release Valve — Hydrant Lateral Fire Hydrant — Water Main — LPAWA Main Drainage - 1 Rail Lines ®city Limits Q Industrial District oa <o Utilities l 9a Mapping Project: Water �•" Distribution 6PIWFal.wonlFol+.y•InP rt T.C))91 ISI470-5039 IMICLAUNCH & MILLER E.Si^Kdea C.I=u .+..mure•sw.rea. r • = Grid Sheet: 011 c•maer.walteu to Cn see CD O 0 a Z N _O N v N NOTES: Grid Sheet Location Water Distribution System Legend Gate Valve Gate Valve (Open L) 6 Gate Valve (Open R) 9 Gate Valve (Abandoned) • Flush Valve • Air Release Valve _— Hydrant Lateral - Fire Hydrant — Water Main — LPAWA Main Drainage + Rail Lines ®City Limits Industrial District �f p utilities O sa Mapping Project: �. Water •*"' Distribution 661 WFcLmore PaR -f Po U17571 1d1I1a5039 FMICLAUNCH & MILLER Ensioccrine Camnlunu w�.cMxTmab.wn sou: r • av GrlO sheet 011 Deu: oec Of. alOY O..w ey wnl�du Ws Or. Ckt, W _Z N O v i Psi al Inspection Check Sheet p Commercial Date: l - a19 — Project Address: C2 yf� a K� Contractor Project Name: File Review Ws 1-9 11 r 1014 er-• C� Ae.>,odT- 3. Zoning Permit in file 4. Customer Service Inspection Certificate in file 5. Back Flow Prevention Device Test Certificates &ld� in file 6. Energy Code final certificate in file 7. Fire Marshal building release in file 8. All required permits in file 9. All inspections on log complete Field Review #'s 10-17 1 a, , Z . �p,�,,, J a..� ply O-w.-.+� ' _ _ • � , ddress # visible fro— s. et 17• �tfC rJ Y� �p •'. 11. Sign m fie in compliance (if applicable) 13. Verify: any required fire separation walls are in place and required rating � R .�/A 18. Inspection ticket to identify if full or temp 30-day CO is authorized Inspector Signature Date SACPSMMUNSPEMON DIvIS1oNUnspcctiomVinel Inspection Check SheetComlDecO8.doc i Wilmore, Debbie From: Huber, Mark Sent: Thursday, October 06, 2011 11:52 AM To: Wilmore, Debbie; Menager, Dwayne Cc: Huber, Mark Subject: FW: 212 W. MAIN FYI Mark W. Huber Deputy Building Official City of La Porte, Planning Department p(281) 470-5067 f (281) 470-5005 h u berm (a) laportetx. gov From: Herrod, Curtis Sent: Thursday, October 06, 2011 11:19 AM To: Huber, Mark Cc: Mayo, Ray; Minor, Stan; Pennell, Don Subject: 212 W. MAIN Mark: As requested ,the size of the water line in the east /west alley behind the subject address is a 3 inch. The size of the water line in the north /south alley behind the subject address is a 4 inch. Let us know if you need anything else. Curtis/ _J Wilmore, Debbie From: Herrod, Curtis, Sent: Thursday, October 06, 2011 12:22 PM To: Huber, Mark Cc: Wilmore, Debbie; Menager, Dwayne Subject: Water Line Cost Estimate - 212 W. Main Attachments: 6 INCH WATER LINE UPGRADE.doc Sorry here's the attachment Mark: The cost estimate attached is divided into two parts. Water Line Upgrade and Alley Repair. Curtis/ CONSTRUCTION ESTIMATE FOR 6 INCH WATER LINE UPGRADE 212 W. MAIN 6/3/11 WATER LINE LABOR $ 2355.00 MATERIALS $ 4000.00 TOTAL $ 6355.00 CHIP SEAL REPAIR LABOR $ 336.00 MATERIALS $ 866.00 TOTAL $ 1,202.00 GRAND TOTAL $ 7557.00 Huber, Mark From: Herrod, Curtis, Sent: Thursday, October 06, 2011 11:19 AM To: Huber, Mark Cc: Mayo, Ray; Minor, Stan; Pennell, Don Subject: 212 W. MAIN Mark: As requested ,the size of the water line in the east /west alley behind the subject address is a 3 inch. The size of the water line in the north /south alley behind the subject address is a 4 inch. Let us know if you need anything else. Curtis/ Menager, Dwayne From: Mayo„Ray, Sent: Wednesday, 6ctober 05, 2011 11:10 AM To: Huber, Mark; Pennell, Don; Mick, David Cc: Herrod, Curtis; Menager, Dwayne; Meekins, Clif; Bottoms, Ron Subject: RE: 212 West Main I just received a call from Mr. Caffey. He advises that now he does not wish to purchase the materials to upgrade the water line. He would prefer to have the City purchase the materials and install the water line. He mentioned that he may contact the City Manager's office in attempt to plead his case. From: Huber, Mark Sent: Monday, October 03, 2011 9:04 AM To: Pennell, Don Cc: Mayo, Ray; Herrod, Curtis; Menager, Dwayne; Huber, Mark; Meekins, Clif Subject: RE: 212 West Main Mr. Mark Caffey, (713)-683-3866. Please provide copy of agreement prior to building permit issuance. Respectfully, Mark W. Huber I appreciate it. Deputy Building Official City of La Porte, Planning Department p(281) 470-5067 f (281) 470-5005 huberm(ci)laaortetx.gov From: Pennell, Don Sent: Friday, September 30, 2011 12:03 PM To: Mayo, Ray; Huber, Mark Subject: RE: 212 West Main That is correct. I sent him a materials list and that is the last I heard from him. Mark, What is the man's name? From: Mayo, Ray Sent: Friday, September 30, 2011 11:58 AM To: Pennell, Don Cc: Herrod, Curtis Subject: 212 West Main What was the final determination on the proposed pool hall? The last I remember the owner was going to purchase the materials to upsize the water main and we were going to install it. Do you have any a -mails pertaining to that? Mark Huber advises that the gentleman is requesting a building permit and they want to put that agreement in as part of the conditions for his permit file. Menager, Dwayne From: Mena9er, Dwayne Sent: Monday, February 21, 2011 8:10 AM To: 'markacaffey@gmail.com' Cc: Meekins, Clif; Huber, Mark; Wilmore, Debbie Subject: RE: 212 W Main Attachments: Zoning Permit Application.pdf; Energy Code Compliance Information.pdf; City of La Porte Adopted Codes.pdf; Cotractors Insurance Requirments.pdf; City of La Porte Wind Load Requirments.pdf Mark, As per conversation at the proposed location commercial plans are required to be submitted to our office for review. The list below is provided as an overview for this type of project. • To add the 2nd floor to the existing structure you will need to speak with a structural engineer and provide the sealed engineers report to the our department for review to ensure the existing 1" floor can adequately support the addition. • All building, electrical, plumbing & mechanical plans are required to sealed by a Texas licensed engineer and or architect. This is required on any structure over 5000 Sq. Feet. • With the change of occupancy to Assembly and increased occupant load some additional requirements may also be required; 1.) Increased plumbing fixtures toilets sinks and urinals. ( The required plumbing fixtures are calculated per the Uniform Plumbing Code table 4-1. 2.) Fire sprinkler/ fire alarm requirements. ( you can contact the fire marshal's office for any specific issues on your project. (Cliff Meekins 281- 471-5076) 3.) Additional egress doors required for assembly occupancies. 4.) An elevator will be required for the second floor. You will need to contact the Texas Department of Licensing and Regulation (Architectural Barriers Division). ADA 5.) All projects over $50,000. valuation are required to be registered with Architectural Barriers. 6.) Harris County Health department approved floor plans required to be submitted with the construction drawings for our review. 7.) You will need to contact the City of La Porte's City secretary's office for requirements related to alcohol licensing. 8.) A grease trap will be required. 9.) If the second floor will be a separate bar from the 1" floor separate stand alone plumbing fixtures will be required: 30.)If the pool tables, pinball machines or any other machines you will need to obtain a Coin operated machine permit. (the application is available at office). 11.)An electrical load analysis will be required to be submitted with engineer sealed electrical drawings. The electrical service'mav or may not be adequately sized to support the proposed loads and electrical service upgrade will most likely be needed. 12.)An asbestos survey will be required to be submitted with the construction drawings for review. 13.)Energy Code work sheets (Com Check) worksheets required to be submitted with the construction drawings to show compliance with the 2009 International Energy Conservation Code. ( See attached Energy Code Handout) 14.)New addition required to designed to meet the 120 MPH Wind load. 15.)Two complete sets of plans and supporting documents are required to be submitted for our office for plan review. t4ark as Mr. Huber and I recom *�' _ Aed during our site visit with you, it wou'ru -ter a good idea to consult with an engineer/design firm to discuss the requirements for your proposed project. They will also be familiar with the code requirements for this type of project. The above items is not a complete list but provided as an overview and as a courtesy. We will be more than happy -to set up additional meetings with you and or you contractor to discuss this proposed project in more detail. Please find attached; 1) City of La Porte adopted codes. 2) Zoning permit application. 3) Energy Code compliance information. 4) City of La Porte wind load requirements. Respectfully, Dwayne Menager Chief Inspector City of La Porte Inspections Division 281-470-5070 menagerd@laportetx.gov From: Mark Caffey (mailto:markacaffey@gmail.com] Sent: Thursday, February 17, 2011 3:47 PM To: Menager, Dwayne Subject: 212 W Main Dwayne, I would like to convert More 4 Less into a billiards, dart, venu. There will be a juke box, couches, large bar (mixed drinks, beer and wine), small amounts of food and a pin ball machines, air hockey etc... The building is roughly 10,000 sf. On the right side of the building you have Chocolates by Mark and the left side of the building you have Vicky's Antiques. I would like to add roof top seating (about 15 feet from the edge of the front of the building, running the width of the building. This will overlook Main Street. There will be a second bar upstairs. I have already applied for the 60 day sign from TABC and should pick it up tomorrow. Please let me know if I need anything else, permits, plans etc... Thank you so much for all you and Mark's help!! Mark A Caffey Chocolates by Mark 2 Zh0 W,Main St La Porte, TX 77571 832.736.2626 Chocolates Perfected http://www.facebook.com/i)rofile.php?id=757635035 My profiles: 10 CHOCOLATES BY MARK Signature powered by WiseStamp J I - _ : S I , A_- - ____ aS . As'S jjb Sq S . j ( Sri I � � °�-.cat17IC—��- I�i�a -r 'sib I A - ___ 9 IA __ __ IIL..._- - --- s - ____ 1 , ► 11 IIt[jtJ1= _ I I . I Ir7�sn i Menager, Dwayne From: Menager, Dwayne Sent: Tuesday, September 27, 2011 10:01 AM To: Meekins, Clif; Wise, Sandra; Simmons, Steven Cc: Huber, Mark; Ramos, Mario; Fitch, Dennis Subject: 212 W. Main Caffey Brothers Billards & Pub Cliff, We have a set of construction drawings ready for your review for 212 W. Main (Caffey Brothers Billiards & Pub) -�`�� y The plans are in the usual place. Respectfully, Dwayne Menager Chief Inspector _ City of La Porte I 1 Inspections Division t 281-470-5070 1 #RT N Z 2-4 M W MAIN ST �� L# w Z Legend 0 Railma0 NI —J-1- Oreinape Cnarrnels .iJ `r Parcel6 jY� Ciry limi+s ne surte5le for legal, engrneemg, wsu"y r- ny me eppm ma:e Sara( a xef of p ope (y bWrKlanes by §2, 0l 102 me Jsar rs enrourageO lWntlepentlently sehly ell nbrme:ron mn(a ec a t"s moc(c wananly as to or accuracy o/ tars proCk Cf or Po is fitness M a perlrcWar pwpose Tire user rl) accepts the poOd.1 AS IS, WITH ALA FAULTS. (2) assumes all MlOn&Wlty rol nq use :r1. :111 OI l.d I�Onp (Trrr do YdmN a IOSS Ol lrabrll(y BI'191i� (�D^� SrrLh �i_Sn O f irm City of La Porte 1 " = 38 ' 604 W Faont Parkway e La Porte, TX 77571 La Porte G I S Mapping p (281) 471-5020 ,.;� ., www.leportefxpov _oi'c. -M -- ,�,'`` _ b' aka COL 01 jolo m/; 517c. (�►s t S�vfro- wIr� /`o ( A L c oA o-L� C9 7r,/-y c t Y IIT� T a A �� �M(•�\t�� EiSN I �rl {il /J� .J c�o �_i-i s►ri 1�� P �4, t nl 1 �` i Y rc..-r &s Puty.'s nk n U DATE APPLIEI BUSINESS NA1 PROPERTY AE LEGAL DESC.: City of La Porte Established 1892 ZONING PERMIT APPLICATIO1. Fee, L50.00 BLOCK BUSINESS PROPRIETOR: PHONE: CITY: BUILDING IS: ( ) NEW LAST USE OF BUILDING: STA ( ) EXISTING CONTACT PERSON: M9 DATE USE CEASED: PROPOSED USE: NOTE. Coordinate with TABC and City Secretary's Office forAlcohol licenselpermit regulations. x OWNER OR AUTHORIZED AGENT DATE ******FOR CITY USE ONLY****** PROPERTY ZONE: FLOOD ZONE: Add TABC/CSO NOTE shown above in permit comment for restaurants/bars, Note Added or N/A PROPOSED SIC USE CATEGORY OF BUILDING: THIS APPLICATION IS: ( ) APPROVED ( ) DENIED COMMENTS: SIGNATURE: PERMIT #: S:1CPShare\INSPECTION DIVISIOWnspectionsVON ING PERMIT APP.doo Rev 9/09 604 West Fairmont Parkway • La Porte, Texas 77571 • (281) 470-5073 o Fax (281) 470-5005 .r, A ADDRESS: ZONING PERMIT NOTES TYPE OF BUSINESS 2. NAME OF BUSINESS & BUSINESS OWNER: 3. ANY CHANGE OF TENANT, USE, OR OWNERSHIP REQUIRES A NEW ZONING PERMIT. 4. IF ANY INTERIOR AND/OR EXTERIOR IMPROVEMENTS ARE ANTICIPATED, CHECK WITH CITY FOR POSSIBLE PERMIT REQUIREMENTS PRIOR TO COMMENCING ANY WORK. 5. THIS BUILDING IS PRE -EXISTING -NON -CONFORMING. NON -CONFORMING ISSUES ARE: 6. LANDSCAPING: EXISTING (OR) NO ROOM AVAILABLE 7. IF DUMPSTER IS UTILIZED AND WITHIN PUBLIC VIEW, APPLICANT MUST APPLY FOR AND OBTAIN A PERMIT FOR A DUMPSTER ENCLOSURE PRIOR TO CONSTRUCTION. 8. PREVIOUSLY APPROVED CERTIFIED SITE PLAN: # OR NO CITY APPROVED CERTIFIED SITE PLAN AVAILABLE. 9. EXTERIOR STORAGE 10. CHECK WITH CITY FOR POSSIBLE PERMIT REQUIREMENTS PRIOR TO PLACEMENT OF ANY NEW /FUTURE SIGNAGE. 11. PARKING ADA/OFF STREET PARKING 12. PLACEMENT OF ANY SHIPPING CONTAINERS REQUIRES PRIOR CITY APPROVAL. 13. PREVIOUSLY APPROVED BY DIRECTOR DATE S:\City Planning Share\04-INSPECTIONS DNISION\Inspections\ZONING PERMrr NOTESAM C COMMERCIAL PLAN REVIENv'ivOTES 1. Minimum six-inch (6") stud walls shall be required where drain, waste, & vent (DWV- horizontal and/or vertical) plumbing is installed. The use of 2 x 6 studs (wood or metal) shall be required for new construction and additions (additions of square footage) for both residential and non-residential construction where DWV plumbing is installed. 2. Call for City inspections - 281-470-5130. 3. Unload and keep materials on private property, not City right of way. 4. If a fence is proposed, verify with City regarding maximum height limitations. 5. Call for utility line locates at 1-800-669-8344 and also City of La Porte at 281-471-9650 6 Fire Marshal will need to review/ inspect prior to opening business. 7. Must obtain zoning permit prior to occupancy of lease spaceibuilding. 8. Separate permit required for all signage. 9. Sanitation facilities required on -site prior to first inspection and must remain available until completion of sanitation facilities within the lease space and/or building. 10. Silt fencing required for duration of project. 11. See notes (red lined) on contractor copy of construction drawings. 12. Fill dirt permits are required prior to placement of fill dirt. 13. Grading/drainage must be maintained throughout entire project to ensure eligibility for inspections and utility release. 14. Provide energy code compliance certification from 'certified" energy code provider, prior to issuance of the Certificate of Occupancy. 15. Any changes to the project after building permit is issued, must be submitted in writing and approved by the City prior to changes being made 16. Provide Sample Well in accordance with "Sample Well Detail" handout. (Available upon request) 17. Effective March 10, 2007, all electrical devices (including but not limited to outlets and switches) shall be installed with the screw -wrap or approved screw clamp installation. Back or quick stab installation is prohibited. 18. Building operations shall be limited to 7:00am-9:00pm and shall not exceed maximum, permitted sound levels as described in Chapter 34 of the Code of Ordinances. 19. Commercial projects with detention pond requirements must be inspected and approved by city Engineer and Inspection personnel prior to final inspection request. Contact City Engineer at 281-470-5060. 20. Contractor/owner shall be responsible for ensuring all construction materials/debris remains on the construction site. Failure to do so shall result in stoppage of inspections and/or code enforcement action. 21. Owner/developer of commercial driveways in concrete shall be constructed 12" from the adjacent asphalt street. The contractor shall clean the area between the driveway and the street to a depth of at least 6". It is the responsibility of the owner/developer/contractor to install the asphalt transition. CONTRACTOR SACPSh=UNSPECTION DIVISIONUnspections\COMMERCIAL PLAN REVIEW NOTESAm 52011 CONTRACTOR COPY IV. APPLICABLE CODES Adopted October 25, 2010; Effective January01, 2011: 2009 INTERNATIONAL BUILDING CODE (IBC) 2009 INTERNATIONAL RESIDENTIAL CODE (IRC) 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2009 UNIFORM MECHANICAL CODE (UMC) 2009 UNIFORM PLUMBING CODE (UPC)** "At the August 22, 2011 meeting, La Porte City Council approved Ordinance 43373. This ordinance amends the 2009 Uniform Plumbing Code by deleting Table 4-1 "Minimum Plumbing Facilities" in its entirety. The deleted table is being replaced with Chapter 29 of the International Building Code which is already a part of the City's adopted building code. No other changes were made. The implementation of Chapter 29 will be effective October 01, 2011. For your convenience, a copy of the adoption ordinance is located on the city's website at: H-AM,.Ial)ortetx.pov/citvdepartments/planning/ inspections divisions/forms/information forms/plumbing code amendment ord 2009 Ed Adopted March 24, 2008; Effective April 8, 2008: 2008 NATIONAL ELECTRICAL CODE (NEC) WITH LOCAL AMENDMENTS (COMMERCIAL & RESIDENTIAL) 2003 INTERNATIONAL FIRE CODE (IFC) WITH ADOPTED AMENDMENTS TO FIRE CODE CONTR /��R� SACPSh=\NSPECTION DMSIONUnspections\Pcsidcntial Construction PeckeM,PPLICABLE CODES.d "6 To , R COPY :l 1 COMMERCIAL PLAN REVIEU A''OTES 1. Minimum six-inch.(6",) stud walls shall be required where drain, waste, & vent (DWV- horizontal and/or vertical) plumbing is installed. The use of 2 x 6 studs (wood or metal) shall be required for new construction and additions (additions of square footage) for both residential and non-residential construction where DWV plumbing is installed. 2. Call for City inspections - 281-470-5130. 3. Unload and keep materials on private property, not City right of way. 4. If a fence is proposed, verify with City regarding maximum height limitations. 5. Call for utility line locates at 1-800-669-8344 and also City of La Porte at 281-471-9650 6 Fire Marshal will need to review/ inspect prior to opening business. 7. Must obtain zoning permit prior to occupancy of lease space/building. 8. Separate permit required for all signage. 9. Sanitation facilities required on -site prior to first inspection and must remain available until completion of sanitation facilities within the lease space and/or building. 10. Silt fencing required for duration of project. 11. See notes (red lined) on contractor copy of construction drawings. 12. Fill dirt permits are required prior to placement of fill dirt. 13. Grading/drainage must be maintained throughout entire project to ensure eligibility for inspections and utility release. 14. Provide energy code compliance certification from "certified" energy code provider, prior to issuance of the Certificate of Occupancy. 15. Any changes to the project after building permit is issued, must be submitted in writing and approved by the City prior to changes being made 16. Provide Sample Well in accordance with "Sample Well Detail" handout. (Available upon request) 17. Effective March 10, 2007, all electrical devices (including but not limited to outlets and switches) shall be installed with the screw -wrap or approved screw clamp installation. Back or quick stab installation is prohibited. 18. Building operations shall be limited to 7:00am-9:00pm and shall not exceed maximum, permitted sound levels as described in Chapter 34 of the Code of Ordinances. 19. Commercial projects with detention pond requirements must be inspected and approved by city Engineer and Inspection personnel prior to final inspection request. Contact City Engineer at 281-470-5060. 20. Contractor/owner shall be responsible for ensuring all construction materials/debris remains on the construction site. Failure to do so shall result in stoppage of inspections and/or code enforcement action. 21. Owner/developer of commercial driveways in concrete shall be constructed 12" from the adjacent asphalt street. The contractor shall clean the area between the driveway and the street to a depth of at least 6". It is the responsibility of the owner/developer/contractor to install the asphalt transition. C® SACPSh=UNSPECTION DIVISION\Inspeaions\COMMERCIAL. PLAN REVIEW NOTESAm 52011 T IV. APPLICABLE CODES Adopted October 25, 2010; Effective January 01, 2011: 2009 INTERNATIONAL BUILDING CODE (IBC) 2009 INTERNATIONAL RESIDENTIAL CODE (IRC) 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2009 UNIFORM MECHANICAL CODE (UMC) 2009 UNIFORM PLUMBING CODE (UPC)** **At the August 22, 2011 meeting, La Porte City Council approved Ordinance #3373. This ordinance amends the 2009 Uniform Plumbing Code by deleting Table 4-1 "Minimum Plumbing Facilities" in its entirety. The deleted table is being replaced with Chapter 29 of the International Building Code which is already a part of the City's adopted building code. No other changes were made. The implementation of Chapter 29 will be effective October 01, 2011. For your convenience, a copy of the adoption ordinance is located on the city's website at: wI"r",.Ial)ortetcgov/citNdel)artments/planning/ ins2ections divisions/forms/information forms/plumbing code amendment ord 2009 Ed Adopted March 24, 2008; Effective April 8, 2008: A 0 2008 NATIONAL ELECTRICAL CODE (NEC) C,f WITH LOCAL AMENDMENTS ')001 (COMMERCIAL & RESIDENTIAL) 2003 INTERNATIONAL FIRE CODE (IFC) . WITH ADOPTED AMENDMENTS TO FIRE CODE S:tCPSh=\1NSPECTT0N DMSIOMInspectionAResidential Construction Packet\APPLICABLE CODESAm Rev. 09-2011 Page is too large to OCR. Page is too large to OCR. viv M A IN j i ( it COMMERCIAL W & S WORK ORDERF DATE 3-Ia-I NEW ADDITION C0r" eM . LEGAL DESCRIPTION LoTS \ —15 4 ,I I 5 FT of LT I'S '2LKS9 OWNER LEA rJ nQuA (LEZ PH# CONTRACTOR S ci2�d PM 73 Z' LA DATE ADDRESS REQUEST (COPY RECM FROM ENGR.) M S D ZONING CLASSIFICATION FLOOD ZONE (PER ENGINEERING) w 5 WATER FRONT FT. FEES SEWER FRONT FT FEES WATER TAP SEWER TAP BUILDING PERMIT PLAN REVIEW FEE ELECTRICAL PERMIT TEMPORARY POWER POLE PLUMBING PERMIT MECELAXICAL PERMIT S.\CPShn c\lwpecdow\COMWI:E RCIAIdNSP SHEE'I'.doc BLDG. PLANS SUBMITTED UTILITY EXT. AGRMT REC'D Y OR N BLDG PLANS REVIEWED BLDG. PERMIT RELEASED FOR ISSUANCE PERMIT # FEES PAID IH-ab O�- 0)1� SO /„r. 1-Vi -39 i Iq,. (oa S(4.aS 0 .0 OEM% -T FAXED: TPOLE CONST ELEV &ERT recv'd (if in AEIVE zone) FORM SURVEY (if applicable) GROUND PLUMBING PIERS SLAB/FOUNDATION WATER SERVICE LINE SEWER ELEC UNDERGROUND (if applicable) -ff --A- EK-UP 3/9* 1 if T Wes_ LEAD TEST BRIPK TIE DRIVEWAY SIDEWALKS FINAL DRAINAGEIGRADING FINAL ELEV CERTIFICATE RECEIVED: ELEVATION SHOWN FOR TOP OF FINISHED FLOOR IS: REQUIRED BFE:- IS THE ELEVATION SHOWN 12" OR MORE ABOVE BFE: (YES) OR (NO) FAXED: GAS FINAL FAXED: ELECTRIC FINAL OTHER (patio, lawn 3prinklers, etc.) =INAL PREPARED 4/04/14, 12:05:03 INSPECTION TICKET PAGE 2 CITY OF LA PORTE INSPECTOR: DWAYNE MENAGER DATE 4/04/14 ________________________________________________________________________________________________ SUBDIV: LA PORTE ICA'VEN E S S : 212 W MAIN ST U-B `C0N'T'R"AC T'O-R—GE'O—S'U'A'R'E'Z PHONE (281) 471-7461 OWNER CAPPEY JIM PHONE . PARCEL 023-192-000-0013 A PPL NUMBER: 1 4 - 00000262—R'E'Mb'OE L, COMMERCIAL ________________________________________________________________________________________________ PERMIT: CR 00 BLDG PERMIT -COMMERCIAL REMODEL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ________________________________________________________________________________________________ PLIN 01 3/12/14 MR PLBG, PLUMBING INSPECTION TIME: 08:00 3/12/14 AP RECEIVED 3/11/14 O 5:05 PLUMBING INSP 2 8 1 - 9 8 9 - 8 9 2 0 PLUMBING PASSED PER MARIO RAMOS. PRAM O1 3/13/14 MR BLDG, FRAME INSPECTION TIME: 08:00 3/13/14 AP FRAME INSP FRAME INSP PASSED PER MARIO RAMOS. INSPECTOR NOTE: THIS INSP IS FOR WALL AND CEILING COVER ON THE ELEC, PLBG, AND FRAME. WLCO O1 3/13/14 MR BLDG. WALL COVER TIME: 08:00 3/13/14 AP WALL COVER —_ WALL POVRR PAggp.n PCR MLRTA YAMOC 14 ED 281-236-0155 `eINAI BLDG) -------------------------------------- COMMENTS AND NOTES PREPARED 3/27/14, 1:18:44 INSPECTION TICKET PAGE 1 CITY OF LA PORTE INSPECTOR: DMAYNE MENAGER DATE 3/27/14 ADDRESS J2'12 W�MAIN ST US SUBDIV: LA PORTE CONTRACTOR .`I: E'O 9GARE2 PHONE (281) 471-7461 OWNER CAFFEY JIM PHONE . PARCEL 023-192-000-0013 APPL NUMBER: 14-0000026'2—R'E N-0DEL. -- COMMERCIAL _______________________ PBRMIT: Pt, _.____��_����?!______________-___________________--____--_-_____- 00 PLUMBING PERMIT SUB: JUAN NAVARRETE (281(989-8920 REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ----------------------------------------------------------------------------------------- GRPL 01 3/12/14 MR PLBG, PLUMBING. GROUND TIME: 08:00 3/12/14 AP Juan 281-989-8920 PLUMBING GROUND PLUMBING GROUND PASSED PER MARIO RAMOS. PLCV O1 3/12/14 MR PLBG, COVER UP - SINGLE TRADE TIME: 08:00 3/12/14 AP Juan 281-989-8920 PLBG COVER UP PLBG COVER UP PASSED PER MARIO RAMOS. SEW O1 3/12/14 MR PLBG. SEWER INSPECTION TIME: 08:00 3/12/14 AP Juan 281-989-8920 SEWER PLFI 01 ^S.E.W.E.R_PASSED PER MARIO RAMOS. 7%'2'T%'1 4 D M `F.I.N.A.L.,—PLUMBING T � __________ //-/1 ____LI_-- tJT--_______ -------------------------- COMMENTS AND NOTES -------------------------------------- PREPARED 3/13/14. 7:11:08 INSPECTION TICKET PAGE 3 CITY OF LA PORTE INSPECTOR: MARIO RAMOS DATE 3/13/14 ----------------------------------------------------------------------------------------------- ADDRESS 212 W MAIN ST US SUBDIV: LA PORTE CONTRACTOR LEO SUAREZ PHONE (281) 471-2461 OWNER CAFFEY JIM PHONE . PARCEL 023-192-000-0013 APPL NUMBER: 14-00000262 REMODEL, COMMERCIAL ------------------------------------------------------------------------------------------------ PERMIT: CR 00 BLDG PERMIT -COMMERCIAL REMODEL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ PLIN 01 3/12/14 MR PLBG, PLUMBING INSPECTION TIME: 08:00 3/12/14 AP RECEIVED 3/11/14 0 5:05 PLUMBING INSP 2 8 1 - 9 8 9 - 8 9 2 0 PLUMBING PASSED PER MARIO RAMOS.- FRAM O1 3/1]/14 MR /) FRAME INSPE INSPECTION TIME: 08:00 WLCO 01 3/13/14 MIL. BLDG, WALL COVER TIME: 08:00 �-j WALL COVER ----------------------- -/////------------ COMMENTS AND NOTES -------------------------------------- 4- City of La Porte 604 W Fairmont Pkwy La Porte, Tx 77571 (281)470-5073 INSPECTION LINE:(281) 470-5130 ****ELECTRICAL PERMIT**** ---------------------------------------------------------------- Application Number . . . . . 14-00000262 Date ------------ 3/12/14 Property Address . . . . . . 212 W MAIN ST UB HCAD Number: 023-192-000-0013 Alternate Search Method: Application type description REMODEL, COMMERCIAL Subdivision Name . . . . . . LA PORTE Property Use . . . . . . . . REAL COMMERCIAL Property Zoning . . . . . . . MAIN STREET DISTRICT ---------------------------------------------------------------------------- Type of Work interier remodel -walls ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ CAFFEY JIM LEO SUAREZ 907 DUMONT ST 308 W MAIN ST SOUTH HOUSTON TX 775873304 LA PORTE TX 77571 (281) 471-7461 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL PERMIT Additional desc . . ELECTRICAL -REMODEL Permit pin number 454496 Sub Contractor ESPINOZA ELECTRICAL CONTRACTOR Permit Fee . . . . 39.00 Issue Date . . . . 3/12/14 Valuation . . . . 0 Expiration Date . . 9/08/14 Qty Unit Charge Per Extension BASE FEE 7.50 1.00 3.0000 EA EL - OUTLETS,SWITCHES (1ST 5) 3.00 20.00 .6000 EA EL - OUTLETS, SWITCHES (OTHER) 12.00 1.00 15.0000 EA EL - METER LOOP & SERVICE/TCI 15.00 1.00 1.5000 EA EL -MOTORS UP TO NOT INC. 1/2H 1.50 ---------------------------------------------------------------------------- Special Notes and Comments March 6, 2014 3:32:57 PM LAPOVFL. 1. ALL WORK MUST COMPLY WITH THE APPROVED PLANS AND CONDITIONS. 2. OWNER/CONTRACTORS RESPONSIBILITY TO COMPLY WITH TEXAS ACCESSIBILITY STANDARDS (TAS). 3. SIGNAGE FOR RESTROOMS MUST BE IN ACCORDANCE WITH TDLR/ARCHITECTURAL BARRIERS GUIDELINES. 4. CONTRACTOR/OWNERS REQUIRED TO COMPLY WITH THE TEXAS DEPARTMENT OF HEALTH SERVICES AND FEDERAL REGULATIONS REGARDING ASBESTOS ABATEMENT. City of La Porte 604 W Fairmont Pkwy La Porte, Tx 77571 (281)470-5073 INSPECTION LINE:(281) 470-5130 ****ELECTRICAL PERMIT**** ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 14-00000262 Date 3/12/14 ---------------------------------------------------------------------------- Special Notes and Comments 5. THIS PERMIT FOR THE REMODEL OF THE RESTROOMS AND ONE INTERIOR 1/2 WALL. 6. ANY FUTURE REMODEL OR BUILD OUT REQUIRES SEPARATE PERMITS AND INSPECTIONS. 7. SEE ATTACHED COMMERCIAL PLAN REVIEW NOTES FOR ADDITIONAL INFORMATION AND REQUIREMENTS. 8. SEPARATE ELECTRICAL, PLUMBING AND MECHANICAL PERMITS REQUIRED. 9. ALL PLUMBING DRAIN WASTE AND VENT WALLS ARE REQUIRED TO BE MINIMUM OF 2"X6" WALLS. 10. ANY NEW OR PROPOSED SIGNAGE REQUIRES A SEPARATE SIGN PERMIT BEFORE INSTALLING ANY SIGNAGE. 11. CALL FOR INSPECTIONS BEFORE ANY WORK IS COVERED. 12. ANY CHANGES TO THE APPROVED SET OF PLANS OR APPROVED SCOPE OF WORK MUST BE APPROVED BY THE INSPECTIONS DIVISION PRIOR TO COMMENCING CHANGES IN THE FIELD. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ---------- ---------- Due ---------- ----------------- ---------- Permit Fee Total 39.00 39.00 .00 .00 Grand Total 39.00 39.00 .00 .00 Signature of Contractor or Approved by Building Off - 4 EiTti�= , Brill Gt. of la nt P Planning& Development Department Phone: 281.470.SO73 604 W. Fairmont 571 p P Fax: 232.470.5005 la Porte, Tx 77571 ELECTRICAL PERMIT APPLICATION w .IBPOMRt 40V 1. PROJECT INFORMATION: DArEorsueAOTTAL- ►ROJECT ADDRESS 0f eA/Dial: S OESCIUBE WORK G rGp. STANDALONE PERMIT?: ®YES Ho (PROVIDE BUILDING PERMIT Nuu&ERP I A-1 - UO2— VIC P PERMIT ISSUE FEE 1 $7.50 1 1 1$7.50 outlets, Fixtures Lights & Switches First Five R Flat Fee) $3.00 ( OutleM Fbaures Lights & $wItche5 Additional over First Five) 50.60/Ea. Washl Machine Dryer $2.00 Ea. Range Receptacle 3.00/Ea. Cook To / Oven 1.50 Ea. A/C, Window Unit Rau tacie $3.00/Ea. Water Heater $3.75/Ea. Dishwasher/Garbage Disposal $1.50/Ea. Meter loop & Service (includes temp. cut -in) $15.00/Ea. "Temporary Saw Pole (T-Pole) $I5.00 Ea. Reconnection of Service S1S.D0/Ea. Electric Welder S2.00 Ea. Motor (less than 1/2 hp) $1.50/E2. Motor 2 hMID, to less than 10 h $2.50/Ea. Motor (10 h to less than 50 h $3.50/Ea. Motor (50 hp and above) 54.50/Ea. Z. PROPERTY OWNER CONTACT INFORMATION: OWNER'S FAME: L9-a,n Afa SuQ I/LZ PHONE; 2$ )- �36 -01 sS MAILING ADDRESS: ' e-m,u be 3. CONTRACTOR/AGENT: Q "HOMEOWNER IS CONTRACTOR AGENT/ COMPACTOR COMPANY:. \nnTLa GLSLtrYLI C,+t L19 A) (L.9[.LOrL PHONE I:!4:1.3 E-MAIL. FAX a: -it'(3-~i"i-'3—/Oy/ MAILING ADDRESS: �v� 3 iL: t, "_ (4- Del A 'l npl i s will / AC TKO 14 I COWACTFERSON-S NAME: OHM: b J 1— y 14 -&9 A/// 4. APPLICATION CCeaHHeEE(CKUST A SUPPORTING DOCUMENTATION (Check applicable bwes): *(fHomeawnerts Conbactar, LY7 COMPLETE ITEMS L THRU A OF POWIT APPLICATION must furnish notor@ed NOtl3 TO A►PUCANTI Homestead A/pdavif • NOTAVAUa PIRMR UMR OWMtl/CLMIIRAROaN MOIeim OPAMINIVKANO AEl AJS1KNt[IRf M[PNOW FILM • MASTER UCFNM A IIFWRANQ RSQUIRFMUM MUST BE CURRENT WITH STATE OF TOMS A D" OF U PORTE • TO REGISTER, SUBMIT CURRENTMASTU LICENSE WSURANCE(WITH CITY NAME &ADDRESS AS CERTIFICATE NOIDFA}NO FEE REQUIRED. • RtINSKCTgN IQ • $SJAP • ••T+OLES MUST K PVMfP UNPCA W&FIATE AFFERATION UNLESS SAME EMMIM CONTRACTOR IS PERMUTING BOTH T-POEE A REMAINING tAKTNCAt VNNR f APPLICANTPRINTED NAMI : "s- r r 0 i APMICIYT SIGNATUREe IranSrArFosrorrEW: Approwd/orissuor)ca By:nnM Date: �' /� 4 iI I4-2f(O 3 IERMI►Moa - `•00 K9 Total PermTsE.15 �(3—-7-73- /02-V FO-X PREPARED 3/12/14. 7:53:25 INSPECTION TICKET PAGE 11 CITY OF LA PORTE INSPECTOR: DWAYNE MENAGER DATE 3/12/14 ------------------------------------------------------------- ___________________________________ ADDRESS 212 N MAIN ST US SUBDIV LA PORTE CONTRACTOR LEO SUAREZ PHONE (281) 471-7461 OWNER CAFFEY JIM PHONE . PARCEL 023-192-000-0013 APPL NUMBER: 14-00000262 REMODEL. COMMERCIAL ________________________________________________________________________________________________ PERMIT: CR 00 BLDG PERMIT -COMMERCIAL REMODEL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS _______________________________________________________ ..__...__ PLIN O1 3/12/14 DMA // PLBG, PLUMBING INSPECTION TIME: 08:00�� /_�_V RECEIVED 3/11/14 O 5:05 PLUMBING INSP 281-989-8920 ________________________________________________________________________________________________ PERMIT: PL 00 PLUMBING PERMIT SUB: JUAN NAVARRETE (281)989-8920 REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ---- _______------- ____------- ___----- _--------- ------ ___----- _________________ GRPL O1 3/12/14 DM./ /4� PLBG, PLUMBING, GROUND TIME: 08:00 v /' _ Juan 281-989-8920 PLCV O1 3/12/14 DM _.✓1� PLBG, COVER UP - SINGLE TRADE TIME: 08:00 ��!/_ Juan 281-989-8920 SEW 01 _-3/12/14_ -DM / PLBG. SEWER INSPECTION TIME: 08:00 /Z/ Juan 281-969-8920 ______________________________________ COMMENTS AND NOTES -------------------------------------- MTZIEWME � n [at stM MW 07' 2014 4OM4.lP'fjt t3iYdFLp POR'fE 4► P R F. Inn, ':StJBdEGT: TlE:�lSE�P'T61� .. 6Qk19MACNT.AT kQwe .Ka :Imp ow .r: •l s./��/✓O fir,¢ ., .. ... teijuaitt:tl.iae orteei�sOia�r`ut9l�lea:rot mn�Itxtiota aAO t►m Ld�± noWaygi�lbtFnppaiinTis6mito4q oy:6000forfto_t.Oe:Pu.,rpoaMeoY pemftbt*d*tum*ft i&liorggn4i1*-v ipbd!hsd:b@eriVwptft l Ooalp4niy:is�ed: Weturthe[•:urider>iaa4 tF�;;vle:t�poe~ary utltoEiaa at"Codw Tlfe 6envaFoohtraetor onA 6aliiir7utieew tAa:respon> oid6saaoabyFheso6mntractat:' tep.�oratlieieslu+rsl oen++►t>racz taroroe,kr a'moiuh�;f 80_dayaf. �f me .-bujl�ip, inMoal•sFiap.basuDiiatmtlbyahf��d.glaprio>f.e deaSilpoi �etinht�ea. .Fal00'uAQpestarld�tli0t.this Pequ�tklid:)ai 68 kaoad.ut>;p �l'peAntbtegliUld tptthp bulkR lfsttsd. :CJIr • .i Yl• '.1.4, r. O ��... \. 10.! 11. 11' 111 . aoe:m': iF effj Vh any,tfty- i► ft. soMw% and Iildinwtiy,4 . #* NVe'be"* -otP )G-6'5 I City of La Porte 604 W Fairmont Pkwy La Porte, Tx 77571 (281)470-5073 INSPECTION LINE:(281) 470-5130 ""+'PLUMBING PERMIT"**" ---------------------------------------------------------------------------- Application Number . . . . . 14-00000262 Date 3/10/14 Property Address . . . . . . 212 W MAIN ST UB HCAD Number: 023-192-000-0013 Alternate Search Method: Application type description REMODEL, COMMERCIAL Subdivision Name . . . . . . LA PORTE Property Use . . . . . . . . REAL COMMERCIAL Property Zoning . . . . . . . MAIN STREET DISTRICT ---------------------------------------------------------------------------- Type of work interier remodel -walls ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ CAFFEY JIM LEO SUAREZ 907 DUMONT ST 308 W MAIN ST SOUTH HOUSTON TX 775873304 LA PORTE TX 77571 (281) 471-7461 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING PERMIT Additional desc . . PLUMBING REMODEL Permit pin number 454520 Sub Contractor JUAN NAVARRETE Permit Fee . . . . 56.25 Issue Date . . . . 3/10/14 Valuation . . . . 0 Expiration Date . . 9/06/14 Qty Unit Charge Per Extension BASE FEE 15.00 6.00 3.7500 EA PL - FIXTURES/DRAINS/TRAPS 22.50 1.00 7.5000 EA PL - SEWER-NEW,REPAIR,REPLACE 7.50 1.00 3.7500 EA PL - WATER HEATER 3.75 1.00 7.5000 EA PL - WATER PIPE/TREATING EQUIP 7.50 ---------------------------------------------------------------------------- Special Notes and Comments March 6, 2014 3:32:57 PM LAPOVFL. 1. ALL WORK MUST COMPLY WITH THE APPROVED PLANS AND CONDITIONS. 2. OWNER/CONTRACTORS RESPONSIBILITY TO COMPLY WITH TEXAS ACCESSIBILITY STANDARDS (TAS). 3. SIGNAGE FOR RESTROOMS MUST BE IN ACCORDANCE WITH TDLR/ARCHITECTURAL BARRIERS GUIDELINES. 4. CONTRACTOR/OWNERS REQUIRED TO COMPLY WITH THE TEXAS DEPARTMENT,OF HEALTH SERVICES AND FEDERAL REGULATIONS REGARDING ASBESTOS ABATEMENT. 5. THIS PERMIT FOR THE REMODEL OF THE RESTROOMS AND ONE INTERIOR 1/2 WALL. 6. ANY FUTURE REMODEL OR BUILD OUT REQUIRES SEPARATE PERMITS AND INSPECTIONS. 7. SEE ATTACHED COMMERCIAL PLAN REVIEW NOTES FOR ADDITIONAL INFORMATION AND REQUIREMENTS. 8. SEPARATE ELECTRICAL, PLUMBING AND MECHANICAL PERMITS REQUIRED. I City of La Porte 604 W Fairmont Pkwy La Porte, Tx 77571 (281)470-5073 INSPECTION LINE:(281) 470-5130 ****PLUMBING PERMIT**** ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 14-00000262 Date 3/10/14 ---------------------------------------------------------------------------- Special Notes and Comments 9. ALL PLUMBING DRAIN WASTE AND VENT WALLS ARE REQUIRED TO BE MINIMUM OF 21IX6" WALLS. 10. ANY NEW OR PROPOSED SIGNAGE REQUIRES A SEPARATE SIGN PERMIT BEFORE INSTALLING ANY SIGNAGE. 11. CALL FOR INSPECTIONS BEFORE ANY WORK IS COVERED. 12. ANY CHANGES TO THE APPROVED SET OF PLANS OR APPROVED SCOPE OF WORK MUST BE APPROVED BY THE INSPECTIONS DIVISION PRIOR TO COMMENCING CHANGES IN THE FIELD. ---------------------------------------------------------------------------- Fee summary Charged Paid ---------- Credited Due ---------- ---------- ---------------- ---------- Permit Fee Total 56.25 56.25 .00 .00 Grand Total 56.25 56.25 .00 .00 Sigttatijf�ot contraic Approved by Building ---- ------------------- or or authorized agent � Date ____ _ __________ 3 / U"l�C Official or aut_h_oriz n Date • City of La Porte '?lannin & Development De artmen , Phone: 281.470.5073 604 W. Fairmont Pkwy. g p P Fax: 281.470.5005 La Porte, TX 77571 PLUMBING PERMIT APPLICATION www.laportetx.gov 1. PROJECT INFORMATION: PROJECT ADDRESS (If existing): 212 (oU • M rt 14 DESCRIBE WORK: DATE OF SUBMITTAL .31 1d STAND ALONE PERMIT?: YES I -I �" Z ® (PROVIDE BUILDING PERMIT NUMBER): I ITEM PERMIT ISSUE FEE FEE $15.00 QUANTITY 1 TOTAL $15 00 Fixtures, Drains & Traps $3.75/Ea. Sewer (New, Repair, or Replacement) $7.50/Ea. / Septic Tank, Seepage Pit, Drain Field $15.00/Ea. Water Heater $3.75/Ea. Gas Piping System (1 to 4 Outlets = Flat Fee) $7.50 Gas Piping System (Over 4 Outlets) $1.50/Ea. Water Piping and/or Water Treating Equipment (Installation, Alteration, or Repair) $7.50/Ea. Drain or Vent Repair/Alteration $7.50/Ea. Vacuum Breaker/Backflow Protection (1-5) $3.75/Ea. Vacuum Breaker/Backflow Protection (over 5) $2.25/Ea. 2. PROPERTY OWNER CONTACT INFORMATION: OWNER'S NAME: ze'ae'l/O �!/A'/-.�2 PHONE: MAILING E-MAIL: 3. CONTRACTOR/AGENT: // ®'HOMEOWNER IS CONTRACTOR AGENT/CONTRACTOR COMPANY: Vy�N /����A�& PHONE 1: f /� 7 elf — 0 K!i PHONE 2: E-MAIL: G C- — MAILING FAX CONTACT PERSON'S NAME: 64411l / r�%fi95CiI-l� PHONE: 2fl �Y O f 2 a 4. APPLICATION CHECKLIST & SUPPORTING DOCUMENTATION (Check applicable boxes): *If Homeowner is Contractor, M-C-O�MP-LETE ITEMS 1 THRU 4 OF PERMIT APPLICATION must furnish notarized NOTES TO APPLICANT: Homestead Affidavit • NOTAVALID PERMIT UNTIL OWNER/CONTRACTOR IS NOTIFIED OF APPROVAL AND ALL APPLICABLE FEESAREPAID IN FULL • MASTER LICENSE & INSURANCE REQUIREMENTS MUST BE CURRENT WITH STATE OF TEXAS & CITY OF LA PORTE • TO REGISTER, SUBMIT CURRENT MASTER LICENSE & INSURANCE (WITH CITY NAME &ADDRESS AS CERTIFICATE HOLDER). NO FEE REQUIRED. • REINSPECTION FEE =S35.00 APPLICANT PRINTED NAME: !/'�G'V �l/����� APPLICANT SIGNATURE: a IFOR STAFF USE ONLY): Approvedfor issuance PERMIT NO.: I `I ';� W Date: Total Permit Fee:$ City of La Porte 604 W Fairmont Pkwy La Porte, Tx 77571 (281)470-5073 INSPECTION LINE:(281) 470-5130 ""BUILDING PERMIT**** ---------------------------------------------------------------------------- Application Number . . . . . 14-00000262 Date 3/07/14 Property Address . . . . . . 212 W MAIN ST US HCAD Number: 023-192-000-0013 Alternate Search Method: Application type description REMODEL, COMMERCIAL Subdivision Name . . . . . . LA PORTE Property Use . . . . . . . . REAL COMMERCIAL Property Zoning . . . . . . . MAIN STREET DISTRICT Application valuation . . . . 7000 ---------------------------------------------------------------------------- Type of Work interier remodel -walls ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ CAFFEY JIM LEO SUAREZ 907 DUMONT ST 308 W MAIN ST SOUTH HOUSTON TX 775873304 LA PORTE TX 77571 (281) 471-7461 --------------------- Structure Information 000 000 ---------------------- Construction Type . . . . . WOOD FRAME Occupancy Type . . . . . . BUSINESS Other struct info . . . . . FLOOD ZONE X ---------------------------------------------------------------------------- Permit . . . . . . BLDG PERMIT -COMMERCIAL REMODEL Additional desc . . COMMERCIAL REMODEL Permit pin number . 454447 Permit Fee . . . . 65.00 Plan Check Fee 32.50 Issue Date . . . . 3/07/14 Valuation . . . . 7000 Expiration Date . . 9/03/14 Qty Unit Charge Per Extension BASE FEE 20.00 6.00 7.5000 THOU BLDG - 1,001 - 50,000 45.00 ---------------------------------------------------------------------------- Special Notes and Comments March 6, 2014 3:32:57 PM LAPOVFL. 1. ALL WORK MUST COMPLY WITH THE APPROVED PLANS AND CONDITIONS. 2. OWNER/CONTRACTORS RESPONSIBILITY TO COMPLY WITH TEXAS ACCESSIBILITY STANDARDS (TAS). 3. SIGNAGE FOR RESTROOMS MUST BE IN ACCORDANCE WITH TDLR/ARCHITECTURAL BARRIERS GUIDELINES. 4. CONTRACTOR/OWNERS REQUIRED TO COMPLY WITH THE TEXAS DEPARTMENT OF HEALTH SERVICES AND FEDERAL REGULATIONS City of La Porte 604 W Fairmont Pkwy La Porte, Tx 77571 (281)470-5073 INSPECTION LINE:(281) 470-5130 ***`BUILDING PERMIT**** ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 14-00000262 Date 3/07/14 ---------------------------------------------------------------------------- Special Notes and Comments REGARDING ASBESTOS ABATEMENT. 5. THIS PERMIT FOR THE REMODEL OF THE RESTROOMS AND ONE INTERIOR 1/2 WALL. 6. ANY FUTURE REMODEL OR BUILD OUT REQUIRES SEPARATE PERMITS AND INSPECTIONS. 7., SEE ATTACHED COMMERCIAL PLAN REVIEW NOTES FOR ADDITIONAL INFORMATION AND REQUIREMENTS. 8. SEPARATE ELECTRICAL, PLUMBING AND MECHANICAL PERMITS REQUIRED. 9. ALL PLUMBING DRAIN WASTE AND VENT WALLS ARE REQUIRED TO BE MINIMUM OF 2"X6" WALLS. 10. ANY NEW OR PROPOSED SIGNAGE REQUIRES A SEPARATE SIGN PERMIT BEFORE INSTALLING ANY SIGNAGE. 11. CALL FOR INSPECTIONS BEFORE ANY WORK IS COVERED. 12. ANY CHANGES TO THE APPROVED SET OF PLANS OR APPROVED SCOPE OF WORK MUST BE APPROVED BY THE INSPECTIONS DIVISION PRIOR TO COMMENCING CHANGES IN THE FIELD. ---------------------------------------------------------------------------- Fee summary Charged Paid ---------- ---------- ---------- Credited Due ---------- ----------------- Permit Fee Total 65.00 65.00 .00 .00 Plan Check Total 32.50 32.50 .00 .00 Grand Total 97.50 97.50 .00 .00 -----------=----------- - - - - -- F---------------- - - - - - - (SIGNATURE OF AUTHORIZED (APPROVED BY 2/JIjiSjffi\0F+Fk CIAL OR AUTHfiRI City of L&ont'P . Planning & Development DepaUN, 604.W.. pairmont'Pkwy. MAR, 0 3 La Porte, TX 77571 ��(( a r, ' PAY; 1. PROJECtINFORMATION: AL: 2: PROJECTADDRESS (If existing): r}- HCAD PARCEL NO(s) 13-digit Tax ID(s): 1.) a 2.) 3.) PROPERTY LEGAL DESCRIPTION: LT S 3 S i, S F I aV L I (g1) 3 L.�� 6 J ®IRRIGATION ®SIGN FENCE �r�� ® POOL S,.-�) p (OtTHHEERty,: �J__VJ GL6lS DESCRIBE WORK: l A /M f 11%�n� I�.0 7 1 aid BUILDING USE: NO. OF STORIES: TOTAL SQ. FOOTAGE: PROJECT VALUATION: G 2. PROPERTY OWNER CONTACT ��INFOORRMATION':t� 2// %`� r\�' OWNER'S NAME: LedA\ \� `�Cl � J�C�G�`� z Po �� )( —� J C7 n ✓ MAILING ADDRESS:\ 3 V'\J/ V I s_� � V� j' L_ G� 1Oo C- 'f- E-MAIL: C'� LJ- l S vJC,_r'1\ n yOG IaA lA l 3. CONTRACTOR/AGENT: IOMEOWNER IS CONTRACTOR AGENT/ CONTRACTOR COMPANY: PHONE 1: PHONE 2: E-MAIL: FAX u: MAILING ADDRESS: CONTACT PERSON'S NAME: PHONE: 4. APPLICATION CHECKLIST & SUPPORTING DOCUMENTATION (Check applicable boxes): *If Homeowner is Contractor, ® COMPLETE ITEMS 1-4 OF PERMIT APPLICATION must furnish notarized ® SUBMIT TWO (2) COMPLETE SETS (HARDCOPIES) OF CONSTRUC--F;GN4ZLANS FOR REVIEW Homestead Affidavit NOTES TO APPLICANT: 1. CONTRACTOR MUST BE REGIST EDW4CERTIFICATE(SURA Y 2. TO REGISTER WITH CITY, SUBM CURE WITH CITY NAME &ADDRESS AS CERTIFICATE HOLDER 3. NOTA VALID PERMITUMILOR APPROVAL AND ALL APPLICABLE FEES ARE PAID IN FULL APPLICANT PRINTED NAME: APPLICANT SIGNATURE: LIvV�I� (STAFFUSEONLY): (� Occupancy Type: IJ Const.Type: �_ Flo Zone: Use Zone(Zoning District): MI CE?:_ Taxes?:� FEES: PERMIT FEE: $ v � PLAN CHECK FEE: $ RESIDENTIAL DRIVEWAY TIE-IN FEE.,$ N A PARKLAND & ZONE FEE., AJA Special Conditions: %1 J�A ^ 7-,e4Ct-, 07`�­i r� ® Must complete all work and pass City inspection within 10 days of permit issuance to avoid fur�thhlervCoode EnforcementActian 7 u PERMITAPPROVAL: Fire Marshal (Commercial Only): t v P-c r C ' M 'Ll DaCe� �l L 0,3 Approved for issuance by: 7+2 Date: PERMITNO. ���' �(1i 12 PERMIT NOTES; 212 W. MAIN STREET 1. ALL WORK MUST COMPLY WITH THE APPROVED PLANS, INSPECTIONS, PERMIT NOTES AND CONDITIONS. 2. OWNER / CONTRACTORS RESPONSIBILITY TO COMPLY WITH TEXAS ACCESSIBILTY STANDARDS (TAS). 3. SIGNAGE FOR RESTROOMS MUST BE IN ACCORDANCE WITH TDLR / ARCHITECTURAL BARRIERS GUIDELINES. 4. CONTRACTOR / OWNERS REQUIRED TO COMPLY WITH THE TEXAS DEPARTMENT OF HEALTH SERVICES AND FEDERAL REGULATIONS REGARDING ASBESTOS ABATEMENT! ; 5. THIS PERMIT FOR THE REMODEL OF THE RESTROOMS AND ONE INTERIOR Y2 WALL. 6. ANY FUTURE REMODEL OR BUILDOUT REQUIRES SEPARATE PERMITS AND INSPECTIONS. 7. SEE ATTACHED COMMERCIAL PLAN REVIEW NOTES FOR ADDITTIONAL INFORMATION & REQUIREMENTS. 8. SEPARATE ELECTRICAL, PLUMBING & MECHANICAL PERMITS REQUIRED. 9. ALL PLUMBING DRAIN WASTE AND VENT WALLS ARE REQUIRED TO BE MINIMUM OF 2"X 6" WALLS. 10.ANY NEW OR PROPOSED SIGNAGE REQUIRES A SEPARATE SIGN PERMIT BEFORE INSTALLING ANY SIGNAGE. 11.CALL FOR INSPECTIONS BEFORE ANY WORK IS COVERED. 12.ANY CHANGES TO THE APPROVED SET OF PLANS OR APPROVED SCOPE OF WORK MUST BE APPROVED BY THE INSPECTIONS DIVISION PRIOR TO COMENCING CHANGES IN THE FIELD. IF THE APPROVED PLANS ARE MODIFIED, A NEW SUBMITTAL TO THE CITY IS REQUIRED PRIOR TO THE CHANGE OCCURING COMMERCIAL PLAN REVIEW NOTES ' , 1. Minimum six-inch (6") stud walls shall be required where drain, waste, & vent (DWV- horizontal and/or vertical) plumbing is installed. The use of 2 x 6 studs (wood or metal) shall be required for new construction and additions (additions of square footage) for both residential and non-residential construction where DWV plumbing is installed. 2. Call for City inspections - 281-470-5130. 3. Unload and keep materials on private property, not City right of way. 4. If a fence is proposed, verify with City regarding maximum height limitations. 5. Call for utility line locates at 1-800-669-8344 and also City of La Porte at 281-471-9650 6 Fire Marshal will need to review/ inspect prior to opening business. 7. Must obtain zoning permit prior to occupancy of lease space/building. 8. Separate permit required for all signage. 9. Sanitation facilities required on -site prior to first inspection and must remain available until completion of sanitation facilities within the lease space and/or building. 10. Silt fencing required for duration of project. 11. See notes (red lined) on contractor copy of construction drawings. 12. Fill dirt permits are required prior to placement of fill dirt. 13. Grading/drainage must be maintained throughout entire project to ensure eligibility for inspections and utility release. 14. Provide energy code compliance certification from "certified" energy code provider, prior to issuance of the Certificate of Occupancy. 15. Any changes to the project after building permit is issued, must be submitted in writing and approved by the City prior to changes being made 16. Provide Sample Well in accordance with "Sample Well Detail" handout. (Available upon request) 17. Effective March 10, 2007, all electrical devices (including but not limited to outlets and switches) shall be installed with the screw -wrap or approved screw clamp installation. Back or quick stab installation is prohibited. 18. Building operations shall be limited to 7:OOam-9:OOpm and shall not exceed maximum, permitted sound levels as described in Chapter 34 of the Code of Ordinances. 19. Commercial projects with detention pond requirements must be inspected and approved by city Engineer and Inspection personnel prior to final inspection request. Contact City Engineer at 281-470-5060. 20. Contractor/owner shall be responsible for ensuring all construction materials/debris remains on the construction site. Failure to do so shall result in stoppage of inspections and/or code enforcement action. 21. Owner/developer of commercial driveways in concrete shall be constructed 12" from the adjacent asphalt street. The contractor shall clean the area between the driveway and the street to a depth of at least 6". It is the responsibility of the owner/developer/contractor to install the asphalt transition. CITY + TV C IF THE APPROVED PLANS CIT i SACPShweUNSPECTION DIVISIO111deC�(�Ch}'lElifT"1 1!CSc* �1} �jjMtS.doc 52011 COPY TO THE CHANGEOOCC_UYRvINGOR COPY IV. APPLICABLE CODES Adopted May 13, 2013; Effective July 15, 2013: 2012 INTERNATIONAL BUILDING CODE (IBC) 2012 INTERNATIONAL RESIDENTIAL CODE (IRC) 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2012 UNIFORM MECHANICAL CODE (UMC) 2012 UNIFORM PLUMBING CODE (UPC) Adopted October 24, 2011; Effective December 1, 2011: 2011 NATIONAL ELECTRICAL CODE (NEC) WITH LOCAL AMENDMENTS (COMMERCIAL & RESIDENTIAL) 2003 INTERNATIONAL FIRE CODE (IFC) WITH ADOPTED AMENDMENTS TO FIRE CODE SACPShamI04SPECn0N DIVISION1lnspmtions\Raidential Construction PwketWPLICABLE CODES.dm Rev. 07-2013 IF THE APPROVED PLANS C�i�V ARE MODIFIED, A NEW SUBMITTAL CITY TO THE CITY IS REQUIRED PRIOR COPY TO THE CHANGE OCCURING Menager, Dwayne From: Meekins, Clif Sent: Tuesday, March 04, 2014 11:54 AM To: Menager, Dwayne; Montes, Raul Cc: Huber, Mark Subject: RE: 212 W. Main No sir Clif Meekins Fire Marshal, City of La Porte 125 South 3td Street LaPorte, Texas 77571 Office: 281-867-4603 Fax: 281-867-4629 this a -mail awl any documents n snsv iued art cWId octal mil lmnded solely ford. use of the irdlvdud or ,miry ro wham they art aNrtss d Ifyvu ha a received this a -mail in.,. pleose m10 the ,ender immedimely. Thu manage may eamaln Low (inforcemem semitive aM/or mr fldemid /t format/an /fyou art mt the w edodd euee )ou should rot dissemimm, distribute or ropy this e-mail and you am and fed that disclosing coPydn dutributhil; or taking airy action in midance ou the contents ofthu informanim is strictly prohibited. From: Menager, Dwayne Sent: Tuesday, March 04, 2014 11:54 AM To: Meekins, Clif; Montes, Raul Cc: Huber, Mark Subject: 212 W. Main Cliff, We have a permit application to remodel the restrooms at 212 W. Main St. Is there any reason you want to see this one? Dwayne Menager Chief Inspector Inspections Division 281-470-5070 Application Tracking Action Log Maintenance Application number: Address: Application type: Revision/Path/Step1S eq/Agency: Action date: Action by: Action code: Time spent (hours(: Correction report item 14 00000262 212 W MAIN ST UB CLIP REMODEL. COMMERCIAL A 01 00 INSPECTION SERVICES 03/O5/2014 IDM DWAYNE MENAGER ARID APPLCNT REVISIONS PENDING 000 geed 1 r o . Need contractors generall liability insurance ■ . show proposed Deny wall i L/3 u,ll location on floor plan e ral 2.00U 3AII Y i,u 4.0i11 r_ S.00] c 6.000 wee N„M,4 7.000 ' 1MyldlyMed Sequence' InMcaNf line Is not available for List selection. lau agcarip. u.a war. x, Received Lo r-a 2 Over the count e MAR fl a 2nm Date./ Initials RecetvdfoN _.,. � � Fil ��rt What,Recei�ed — -- DtWoosition / kw b. 2 `cz oc\ CSC S rr 3 0?7/ l `� /3- 502- 0a (o NEZC i 4 { l � fS g L/P/l vi 5 .5 -q 1' La z v;-/-/LS Io dhLci 10 �la�l ly irv� Ea Sail a8I- 151 1�Q2 F� 1� 1 ,- ft1$%rJ V� iT �k",. c o k1 t L�- Q C, DM 12 �31) -i ��i PnLAL L/l i(s , "1I3- fC�1-�7Sc 5, �-C w MyL,a-Ie- L > II w J3�11>Ov.t')c�it -I 13 � 1 ( —" �jCklUftz �CGivC,(� �' — �I� ` r ✓ -}� I )��r� 1D�'► � .�, w�� to i L, • I�tv � �� Ks � � -...A15 Not SAP ro ph S Drive (CityShares)/ City Planning Share/ 04- Inspections Division/ Inspections/ >,W"g Over the Counter ` COMMERCIAL EC E IVE " y PLAN REVIEW COVER SHEET _ MAR 0 31014 (114TERNAL USE) 9 ADDRESS: 12 ca , M r\�l \J OWNER'SNAME: LC z, Suck �z PROJECT TYPE: G c-) r, t NEW:_ ADDN:� HCAD#: I HTE LOC#: FLOOD ZONE: . X USE ZONE: e-7-) r)o YIN SUB /DATE RETURNED THUCZ-ONE? ZONING PERMIT C ASBESTOS SURVEY RECEIVED (Applicable on Demo, Addn, or Remodel) (It'��s permit cannot be -issued.) C 1U0OD rERN-T NEEDED?: W&fEES-A-PPL7C-ABLE.: (If yes, figure fees. If no, use w/s form to explain why they are not.) 1 �94/�1M�YS@NiiYiG'L�YS 7TA7 ITV PRu1\"1Qi DATE OF REVIEW: INSPECTOR: '6 ITEMS NEEDED FOR ISSUANCE OF PERMIT: 1. CURRENT INSURANCE CERT. (if applicable) OK 0-F' (S l ..11 C�Tta� (,,,.,0 /�'-u\)A9- ��-G /✓%C./)i C.O^'1�\a7-"� C n pS�,�AT^,on1 /CS (3LS1- ACcLPjCadt-cLhCi TT /,.is r�-JCq-_ j t,-Cr r4: G.c. OWNER OR CONTRACTOR NOTIFICATION DATE TIME NAME OF PERSON CONTACTED S:1CPSh=\INSPECnON DTVISION\JMpectiom\COML PLAN REVIEW COVER SHEETAm Rev. FEB2012 1.: a flNINt���C ���•,,,� `l aolad a3�nad: sa :_l�� �Nl of 1v111N8ns ,+r ?a+ SNVI 1.: > ^�06 Zo c :�U=. CD, CA E E E ti 3 ot ! z 61134 C!i to N E O 0 CN w 0 c 3 N O W J N Ln � A o n 0 O y C I A 3� J E DATE: 2/27/2014 SG4LE: SHEET: .-, 3 ?ply I� LOFLIN ENVIRONMENTAL SERVICES, INC. March 5, 2014 213 West Main La Porte, TX 7757 Attention: Leandro Suarez Subject: Results of Asbestos Survey 212 West Main — La Porte, TX Loflin Environmental Services Project No. 200-14-95 Dear Mr, Suarez, Loflin Environmental Services, Inc. (LOFLIN) has completed a limited asbestos survey of the above referenced location. The purpose of this work was to identify the presence and quantity of asbestos containing materials within the space potentially affected by renovations. This work was performed on March 3, 2014, by Joshua Songster, DSHS Inspector ri'602374. Visual observation of the building revealed floor tile and mastic and wallboard joint compound as the only suspect asbestos containing materials. Representative samples of these materials were collected and submitted to LOFLIN's Houston laboratory for asbestos analysis. All were analyzed using Polarized Light Microscopy (PLM) coupled with dispersion staining in accordance with EPA's "Method For The Determination Of Asbestos In Bulk Samples" EPA 600/R-93/116, July 1993. Based on laboratory analysis, one of the sampled materials was found to be asbestos containing. Nine inch floor the was found to contain asbestos on concentrations greater than 1%. Approximately 150 square feet are present. Underlying black mastic was not found to contain asbestos. Joint compound was determined to have 1 % or less asbestos. Attached is a table of laboratory results. Lotlin Environmental Services, Inc. appreciates this opportunity to provide these testing services. If you have any questions concerning this report or the work performed please contact us. Sincerely, Loflin Environmental Services, Inc. CITY 6 �-*AA-7 P COPY James Murray, CIH, CS Vice President 2020 Montrose ♦ Houston, Texas 77006 ♦ (713)521-3300 ♦ FAX (713)523-0829 r n W_�t. Min Environmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006 (713) 521-3300 Fax (713)523.0829 Report of Bulk Sample Analysis For Asbestos Identification Polarized Light Microscopy (PLM) EPA 600/R-931116, July 1994 Client: LEANDRO SUAREZ Client Address: Project No: 200-14-95 Project Name: 212 W. MAIN ST, LA PORTE, TX Date Received: 3/4/2014 Date Analyzed: 31412014 Page 1 of 2 Lab Field Sample Sample Asbestos Additional Number Number Description Location Detected Constituents (Components) L217797 1 WHITE, POWDERY <1 % CHRYSOTILE CALCITE, QUARTZ, MICA NONHOM OTHER (JOINT COMPOUND) WHITE, POWDERY TRACE CALCITE, QUARTZ, MICA (JOINT COMPOUND) CHRYSOTILE OTHER (POINT COUNTED) L217798 2 WHITE, POWDERY .25% CHRYSOTILE CALCITE, QUARTZ, MICA NONHOM (POINT COUNTED) OTHER (JOINT COMPOUND) WHITE, POWDERY .25%CHRYSOTILE CALCITE, QUARTZ, MICA (JOINT COMPOUND) (POINT COUNTED) OTHER L217799 3 WHITE, POWDERY NONE DETECTED CALCITE, QUARTZ, OTHER HOMOGENEOUS (JOINT COMPOUND) L217800' 4 GRAY, GRANULAR 3-5% CHRYSOTILE CALCITE, VINYL, QUARTZ NONHOM (FLOOR TILE) BLACK, TARRY NONE DETECTED TAR (MASTIC) L217801' S GRAY, GRANULAR 3-5% CHRYSOTILE CALCITE, VINYL, QUARTZ NONHOM (FLOOR TILE) BLACK, TARRY NONE DETECTED TAR (MASTIC) Laboratory Manager 'Asbestos -containing materials - The type and percentage of various fibrous components was determined by the microscopist in accordance with U.S. Environmental Protection Agency 'Method For The Determination Of Asbestos In Bulk Samples' EPAr600rR-931116, July 1993. Departures from the test method., None The above test report must not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government. Analysis results on this test report pertain only to those materials tested. Disclaimers: Asbestos content Is quantified using Calibrated Visual Estimate. PLM analysis has been known to be inaccurate for materials with low concentrations of asbestos. Negative PLM results cannot be guaranteed. LES recommends using TEM analysis for materials reported as <f % or none detected. This report may not be reproduced, except in full, without written approval by LES. ILo/lln Environmental Services, Inc. 2020 Montrose Blvd., Houston, Texas 77006 (713) 521-3300 Fax (713)523-0829 L� NVLAP 10-2044 MH Lab 300031 Report of Bulk Sample Analysis For Asbestos Identification Polarized Light Microscopy (PLM) EPA 600/R-93/116, July 1994 Client: LEANDRO SUAREZ Date Received., 31412014 Client Address: Date Analyzed: 31412014 Project No: 200-14-95 Page 2 of 2 Project Name: 212 W MAIN ST, LA PORTE, TX Lab Field Sample Sample Asbestos Additional Number Number Description Location Detected Constituents (Components) L217802' 6 GRAY, GRANULAR NONHOM (FLOOR TILE) BLACK, TARRY (MASTIC) ill Laboratory Manager 3-5%CHRYSOTILE CALCITE, VINYL, QUARTZ NONE DETECTED TAR 'Asbestos -containing materials - The type and percentage of various fibrous components was determined by the microscopist in accordance with U.S. Environmental Protection Agency 'Method For The Determination Of Asbestos In Bulk Samples' EPA16WIR-931116, July 1993. Departures from the test method: None The above test report must not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government. Analysis results on this test report pertain only to those materials tested. Disclaimers: Asbestos content is quantified using Calibrated Visual Estimate. PLM analysis has been known to be Inaccurate for materials with low concentrations of asbestos. Negative PLM results cannot be guaranteed. LES recommends using TEM analysis for materials reported as <f % or none detected. This report may not be reproduced, except in lull, without written approval by LES. Menager, Dwayne From: Leandro Suarez (leo308@sbcglobal.net] Sent: Thursday, March 06, 2014 1:56 PM To: Menager, Dwayne' Subject: Fwd: Asbestos survey Attachments: Leo Suarez 212WestMain.pdf Here is the information you requested. Thank you Sent from my iPad Begin forwarded message: From: "Roger M. Moss" <roeermmoss@swbell.nev Date: March 6, 2014 at 12:54:46 PM CST To: <Ieo308(@sbcelobal.net> Subject: Asbestos survey Reply -To: <rogermmossQswbel1.net> Leo, Please find the attached survey report as requested. The invoice will follow in the mail. Thanks Roger Moss i w; �tiT��CTOR ARE Mpp F DPROVED PLANS T 0 lHE CITY IS A NEW SUBMITREQUITAL 10 THE CHANGE OCCUR�"/O� 16"OC Wall will be covered with 1 36" door will be instaled. /2" ply Wood. on both sides. a