HomeMy WebLinkAboutO-1987-915-Q-2- V
•
ORDINANCE NO..915-Q-2
AN ORDINANCE GRANTING A PERMIT UNDER SECTION 18-a-3 OF ORDINANCE NO..
915,'-PIPELINE TRANSPORTATION," BEING CHAPTER 18-A..OF THE CODE OF
-.ORDINANCES.OF THEiCITY OF;LA PORTE; TEXAS, AND APPROVING THE
APPLICATION OF AIR PRODUCTS AND CHEMICALS, INC., TO OPERATE'A TEN -
INCH (10.".).PROPYLENE'PIPELINE; AND PROVIDING AN EFFECTIVE DATE
HEREOF. 0'
BE IT ORDAINED BY�THE•CITY COUNCIL OF THE.CITY OF LA PORTE:
-Section l.;i' The City,.,Council of the City of La Porte.has
received -an .application dated January_ 27; 1987,. from .AIR PRODUCTS
.'AND CHEMICALS,. INC.,,requ;esting a.permit-under Section 18-A-3 of
III r _
Ordinance 915, being Chapiter 18-A .of the Code of• Ordinances,_of the
City of La Portee, Ito operate a ten -inch . (10") nominal diameter
propyle.ne�pipeline crossing the City of°La Porte, all as shown on
it + .
said-application.The application. of AIR PRODUCTS AND CHEMICALS,
INC:,;has been.Ireviewed by the City's Director of'Public Works, who_
..has found that Said application meets all.requirements of said
Ordinance No. 915,1,and has recommended its. approval.
Section 2.1 The City';,Council of the City of La Porte hereby
approves the applcaton of AIR PRODUCTS AND CHEMICALS, INC., dated
March 28, 19881,iand this�Ordinance shall' cons.titute.a permit.to AIR
PRODUCTS AND:.CHEM CALS, INC. :to operate said pipe 1•ine within the
City_ of La Porte, :all in ;conformance :with the: -requirements of said:
Ordinance No. 915.1 The City of La Porte approves the assignment of:
_ this :permit'.to Il,exaco Chemical Company.
Section' 3. '
ll The City; Council officially finds, determines,
recites and declares .thaty'a sufficient:written notice of the date,
hour,:place-andlsdbject of this meeting of the City Council was
.posted at a. place ;convenient .to the public at the City Hall of the
City for the timeirequired,by law preceding this'mee'ting,.as
..required by the;Open Meetiings Law,., Arti..cle 6252-1.7, Texas.Revised
`- tC*1�atutes-�AnriYotated, !-a-nd-that:�th.is,me.et_i-ng, has_beenoen to _the
._
.public as required by law at all times during. which this ordinance
i
and the subjectCmatter thereof has:been discussed; considered and
formally acted upon. The,'City Council further ratifies, approves
No Text
a �
y ,
I
Air Products and Chemicals, Inc. .
!I
12600 Northborough Drive. I,
Suite 214 4
Houston, TX 77067
Telephone (713) 873-2311
II
City,of LaPorte
Post Office Box 1115
LaPorte, Texas 77571 ;�
`. Cheri e I Bl a.ck
Attention; Ms ;
City Secretary'
713,1471-50 20
Subject:. -proposed Sale of Air Products 10 Pipeli
ne Covered by LaPorte City Ordinance
No. 915-Q to Texaco Chemical Company for Propylene Service..
Dear Cherie, p ;
Approximately 12 months ago, I contacted LaPorte regarding the following:
(1) to request LaPor�te's consent to transfer the service of the subject pipeline from
carbon dioxide service to ethylene service.
(2) to notify LaPorte that the subject Ordinance would-be assigned to Cain .Chemical
Company'(formerl�y, Corpus Christi Petrochemical Company) who was proposing to
purchase the pipeline and put it'An ethylene service..
-l:atched as
The, request . i n (1) above was granted by LaPorte .via ,:Ord o ed-eon o thel pi pel i netaand 'Air
Exhibit .A-._• To make I urpose of
a long story short, Cain never. closed-,Ordinance
l
Products has since.�entered into an. Agreement with Texaco:Chemical Company- who is
proposing to purchase the pi pelf ne .. and put it -inn propylene ' service: The p
this. letter, therefoe,,is the following:
(1) to request.LaPorte'js consent to -transfer -the service of.the subject pipeline from
ethylene service' to propylene service.
notif LaPorte that the subject Ordinance wil"l be assily with all the terms. gned to- Texaco Chemical
(2to ) y
Company who, by�fsi,gning below, agrees to comp.and conditions
(including the ;200.00 annual fee) of the subject Ordinance
.
lease have the appropriate party sign both
If-'La'Porte.concurs wiith the above request,,. p at the above addresss.
COP
this letter below and return oncopy-to my attention
9 i
Please note that al it of the" safety issues we np addition, pleases note thatd. for ytheeuse are
pipeline
substantially the.same�,for propylene use
was. successfully pressure tested -to 1100..psig'on.15. October. 1987 in accordance with.
Department of Transportation test requirements. The documentation and certification
for this test are attached as`Exhibit B. (Texaco's proposed operating pressure is 600
).
No Text
Ex,
h
i
THE STATE OFITEXAS
COUNTY..OF HAR�RIS �
CITY OF LAI PORTS
I hereby certify that the attached and foregoing is a
j passed assed and
true and cor�re t copyi of. Ordinance 915-Q-
of La Porte at a
approved by!lth�e City Council of .the City .
Regular MeetinJg of Council held on the 23rd day o
f February,
of the Council pre.11
sent
a a majority .
1987, at wh;{�ch meeting
f the Ordinance. I further certify that Said
voted , in fa,'�or o .
s'o erly,!:'posted according to law, prior, to the
meeting wa ,� p P
date of,the'meeting.
a
of Office,.
To certify which, witness my hand and Seal
this the 24,th? day o f February, 1987.
f I
City Secretary
d
a
7 G
r El -
AIR
Air Products and Chemicals, Inc.
MOOLx S'�
2600 Northborough Drive
Suite 210
Houston, TX 77067
Telephone (713) 873 0161
r
! 27 January, 1987
Ms. Cherie. Black
City Secretary
City of LaPorte
P .. 0.. Box 1115 , i
Texas!'77571
LaPorte, .
Subject: Air Pr duct's 10" Pipeline Covered by LaPorte City Ordinance
No. 915Q
Dear Ms. Black151
Pursuant Xogour telephone conversation on 16 January, Air Products
Inc.) have
and Chemicals; Inc.. (and ,;its wholly owned subs diary, pipeline (maad attached) to.
P
" made provisions to lease and sell the subject p'p April.
an ethylene distribution:,company. The lease is scheduled for 1
1987, while consummation of . the pipeline's sale' is' scheduled'. for 1
ill be
October. 1987. ',i The lessee. and eventual new owner ofC,Cp e")PiPorl'-ae. related
either..Corpus Christi Petrochemical (• Company. Im erial .Pipeline
pipeline grouIp comprise&` of Champlin Pipeline, Inc., P.
" n CCPC and The Group are
Inc. and :Solt'ex Pipeline;_ Inc.. {The Group ) . ( ears on the lease and
affiliated companies andlwhich name eventually appears
bill of sale,jlis�:a function of a re -organization issue that cannot be
resolved until a� later date.)
. The gurpose' of this;'letter is'.twofold as, follows:
(1) To request the-City's to put the pipeline into
written consent
April 1987 (the pipeline has been
ethylene service beginning 1 AP e
ears
in!' aseous carbon dioxide service the last six.years.).
co h
(2) To '�notify the ;;city that-0 rdinance No.- 915Q (copy attached)
attac
Toil assigned to one of the two potential assignees..who, by
signing below, agrees to. comply with all the terms .and.
conditions (i>zcluding fees) of Ordinance No..915Q.
q above
If the ;City of LaPorte con -this .b t copiesth the e f thisnl titer below
i. please have 'the appropriate party sign
and return one copy to my attention at the above address. If necessary,
representatives$ of Airj,Products, GCPC and The Group .would be -happy to
appear before City Council.and answer any questions. or concerns you_ may. .
have.. I understand that Council meets the 2nd and..4th Monday of every
month at 6:i
O0 P.M.
No Text
Test Re,)o
Calculations (Water Only)
EWO NO. AFE 11
REPORT NO.
i�� CNEIh�'ac Go�tr DATE �o/1o/d7
CLIENT
PROJECT NAME r
ll
CONTRACTOR (S) u!'S• h /kC.
TEST. SECTION DESCRIPT
PIPE DIAMETER
PIPE GRADE
STD. MILL TEST PRESS. _
HYDROSTATIC TEST PRE
MINIMILIMTEST PRESSUP
UNIT VOLUME AT 60�F
NET VOLUME ADDED TC
DATE OF TEST
TIME OF TEST
TEST PRESSURE
TEMPERATURE ��Ra
Fwrp
Fpp
Fp n
(VOLUME AT TEST
6 vtpw
UNACCOUNTABLE D
FLUID LOSS RATE
TEST ACCEPTED
NOTES:
'Vtp = Vo (Fwp) (Ft
APOSITIVE DEVIL
ERROR
A NEGATIVE DEV
VALUES_BETWEEI
.._I
/0. ?SO inch
NOMINAL WALL THICKNESS inch
SECTION LENGTH
/55, 740 feet 2f 5 k
psq
PRESSURE TO YEILC
/2Z4= Pik
,, psl9
MIN. ALLOWABLE PRESS....
I RING TEST PERIOD
aco
psq
D
¢,• 3�i ofo pal/h
TOTAL YO LUME W.)C�3
>g 7T • 4 GL
+) OR BLED FROM (-) TEST SECTION (Vm)
R _
I!
(2)
INITIAL
FINAL'
d
io/i5 497
I
psg
I 1 oo= ...: - . psro
-78 .F
CtIAaT)
QV3Q7 ,w
/. G�0547G. 4�j4
/ A�S`354810
�
0. 91"2 9 2 00
p.948Zc� 'TCaO
''
loci •732�'S ¢al.
Coft 7I7.8 �I•
' E
p & PRESS ?
.
I
/4•► 7 2
gal.
0)f Vtp(2f VrrA 1
tP
x 100% a• 002
% (SEE NOTES)
(6v
ION
;
Nt.*
PRESSURE LOSS RATE
~tA
TEST ENGINEER.
I GLIEN•F xmw
r E
OF
s tit
C
11 (Fwpt) * .
Jr
1 ION REPRESENTS FLUID GAIN AND IS DUE TO MEASUREMENT ' unq
►TION REPRESENTS FLUID LOSS AND IS ACCEPTABLE FOR.
0.00% and
I, ,
October 20', 19817
.-.Monsanto. Chemical Company
P.O. Box
Alvin,. Texas ?7512
Attn:.Mr. Butch Middlebrook
I
Subject: Hydr6static"Testing'of.10" CO2:Pipeline From
Texas City .to LaPorte
Galveston and Harris Counties; Texas
(b'y U.S. Leak- Detection, Inc.)
Test Date: October 15, 1987
I I •
Dear Mr. Middlebrook:.,.
This letter'certifies.that the hydrostatic testing performed on
the _ subjects CO2 pipeline by U.S. .Leak Detection, Inc.. met- the
requirements of .Title 49., CFR-(Dept. of Transportation), Part
192, "Trans�poitation,. of Natural and .Other Gas by Pipeline:
Minimum Flederal Safety Standards", Subpart. J, "Test
Requirements".
1 The pipeline was tested -.for eight (a) hours, at.
a minimum ;pressure ,of 1100 psig, successfully ccode. ing the
mechanical'aitr6ngth test requirements of the above code..
The calculti4ons performed on this test section to correct.'for
temperature lJa'nd pressure -related volume changes in the- pipeline.
are, attached �� for your information only. Without true ground
(pipe).tempera1tures,ithese calculations are not to be considered
fully accuat�e. Hgwever, €or the assumed constant ground
temperature's of 78 d'eg.. F., it -does appear that the. section is
free of leaks.4
{
Very. trulyyoura, a _•��..,�►��
OF
William M. Olson, P.S.' S�VULIAM Y.
9 537n
attachments
• ��S�01tAL E��'`i
11 � . �l�a�•.��a
PIPELINE COMPANY r
PIPELINE CONTRACTOR
TEST SECTION NO.
TEST BEGAN: DATE 1
TEST END: DATE,
PIPE DATA: 10" CO
HYDROSTATIC TEST REPORT Pag..vco 2
PIPELINE DMI11W
NSANTO 10" CO 2 LINE
.JOB NO:
W.O. No
U { S: LEAK DETECTION, INC. AFE NO:
ERAS CITY. TEXAS
/15/87 TIME 1:10
/15/87 TIME 9 :10
Z:
TO Lei " PORTE , TE XAS
PRESSURE
UNIT NO. STATION NO.
LEYATION
88 Wall 29.5 miles a
Gra e B
i
4
HYDROSTATIC TESL' REPORT
d
0 I
Pago � CO ?—
PIPELINE DWSIO
II 10" Co. LJOB NO:.
�
PIPELINE COMPANY
JW-O. NO
PIPELINE CONTRACTOR, U S., I'M LFIECPIC>N' nc' , AFE NO:
S QM` TEXAS TO LA POME` TEXAS
TEST SECTION N0.
I PRESSURE
TEST BEGAN: DATE 1{�/i A7 TIME I • UNIT NO. STATION NO:
TEST END: DATE 10�15�87 TtME9.10 pm ELEVATION.
PIPE DATA: , i.
III , I ,
DEADWEIGHT SERIAL NUMBER
87
° 15988 DATE CERTIFIED 30 Jane 19DEADWEIGHTPRESSJRE
34 71M 1987
RECORDER SERIAL
RECORDED SERIAL
NUMBER 6257 DATE CERTIFIED
NUMBER1 6268 DATE CERTIFIED 30.TtmP 1987
TEMtPV;ATURE
" TEST IS SACCEPTED 110REJECTED
'' If REJECTED. EXP AtN
1 DEADWEIGHT RECORD
i
T'EM'PEFtATURE
T'te�e Prmure
Ambient Pipe or Ground Resflar4f
5:30 Em _ 1103
84'
6 : 00 1102 ill
81,
6.30 110011
9 78'
7:00 1100 !II
f 75 •
7. 30 1101 ill
7. 75 •
8 : 00 Pm 1100 III_1
74
8 t 30 1100 ill
I 74
9:00 1100lh.
i 74
9:10 1100 ili
i 74,
I. I I Off Est
II �
Il i
TEST FOREMAN
INSPECTOR
tSaRacbnl rson.r•.,
�r !
6-;1'�i3R0S7ATIC TEST F,EPORT PW I of_az._
MKILINE Drialmi
!
PIPELINE COMPANY o C�c L JOB NO:
} W.O..NO
PIPELINE CONTRACTOR I AFE NO:
TEST SECTION NO. --
TEST BEGAN:, DATE LC L
TEST END: DATE II, 11
`
PIPE DATA:_
DEAL,"-^--IGKT SERIAL NUMBER
PRESS�_RE RECORDER -SERIAL
TE69P-E7-%ATURE RECORDED SEF
.TEST EJACCEPTED
Ts:ws Pressure
'tom
.'_A15'
_ • _ fL J
TEST FOREMAN
X-1 TO .MCA Pole7' xifs
=SSURE
IT NO. STATION NO.
ELEVATION
DATE CERTIFIED
JMIBER �e S' �% DATE CERTIFIED
1L lNUMBER L! e(� i� DATE CERTIFIED TV- ,-j I'i P17
REJECTED I' IF PZjFCTED Em-A&N
DEADWEIGHT, RECORD
T E M P.E.R A T U R E
AmbleAt Pipe or Ground Remarks
I
'.
73"
irO L 4 T1 A Te ft. , 4'
0.
73"
22 -&sl
Top
A2
440
r -INSPECTOR
PIPELINE.COMPANY—
PIPELINi CONTRACTOR
TEST, SECTION NO.—
TEST BEGAN. DATE
TEST END: DATE.'
PIPE DATA:
/4p
HYDROSTATIC TEST REPORT
90 A) SA 7-0 0 JOB NO:
W.O. NO
h- -q AFE NO:
_TIME
-TIMEAL
7
PIPELINE D;V-.Jlok�
To 4c"a -rAr-- x #93
PRESSURE
UNIT NO. STATION NO.
ELEVATION--
•
110KNNY'S;, GAUGE- & METER REPAIRS
"iOHFNNY ON, THE SPOT'
713 • 6;95 • t 038 718 pUNtMO0E3Y
HOUSTON, TEXAS 77076
una
cz1G:-
C.
•1� -_.. '���11-.rif_"rC i _ear ..ems' 'v _Cr • :LC�.Z 1. C: .0 •r� - _
. _Cale
us it r.� -
" B y
1-12° C-T Tnvalco Pressure 'Recorder 0-3,9004 SIN 6257'
v I;
�•.., _ ram..,,._ r,^ t ; ,. a �ura�.0 o
�r::cisionl ;_�.d�?I•Gj.-.e_..L_ .,.mod _o _
;shcro � �. ` _ - r = - ria1 _'o 343%?
i er-if_-d
J JGFi::2+Y' S GAUGE & IDS 'T::R RD-PAIRS
JOHNNY'S GAUGE & METER REPAIRS
I)OHNNY ON THE SPOT"
713 - 695-1038 .718 DUNWOOOY
1140USTON, TEXAS 77076
June.�:. l;l r .
7
77nc.
I'-'
US!, n, j ton 0
J,
7. 0
:L
d,
--.cc to -plus or 0 0 .;— u, sc_ 1C.
-1211 c-Eanvalco, Temperature 'Recorder 0-150 P SlY. 6268
zrec-isi-o-. ta n e a
'rds',I! -;e-re—inced to .'..at- - or al iurz-- u of,...tar lards
-n)srature -'atli
'aylor 2s-4
Uertirll b
%TOM. NY 8 GAUGE P, IC-T3R- REPAIR:
J
JiL
XmIr"Sl!'GAUGE&,METER REPAIRS
u"I
HNNY ON, -THE SPOT"
713 - 6XI "W
038 718 DUNOODY
:i. HOUSTON. TEXAS 77076
,v
-7
U
0.
'z 2
.,_? .. G-c IQf 5, "'curd tO
—3 bsts oc� i ir 0.
1:. r
.0
or
Cale
N-
1-Chandl r Dead 'fielight T18-988 .ester 50*59000-;
a d;,- r d 3
-fc- ren. c e d to .-at-ionF-1 urt u. o'
.rre.c is - o.
:es*.# .0.,tCC 7 "32"./2^
e erial --'o- 34"t'-7
s s r
il ad-n-, e 1
-.S c1ro-
II
r rti -f z� by
J-
111000""'0011
JOIMIY S GAUGE & VIMER REPAIR&
No Text
1 ' . , ... it •
'I
III •�. -' 4o ,- *t4. --�� _- ';- _
� �� is i --` — � � •� ;
�" ' Off`' ,�i," •• -_� - �=
w ,g. �:�L�. •N •METE •�•• _ q' ssuae yes � ` �`�.`
p i f J P• j' . l�,f C ,/��(/ '' �'+` J'�j. , - 1 �yx gyp+ •'1
• - r G-412
'R,I
PC it
40
_ � � - $. !I_ i•!• -! _ -_ '� ,yam ... � '
ZQ $
Ap
i.\�'•+� Oj. '. yot. �+ fir
• III• ! i. _�� — � _• _ O`.
[t
l - ob
CA
6 9 Mtt
8-®Lm
No Text