Loading...
HomeMy WebLinkAboutI & J PROPERTIES CAPITAL IMPROVEMENTS SITE PLANPORT VALE INC (126 N VIRGINIA) HCAD ¢023 257 082 0010 LOTS I0-1'S (60' R.O.W.) L—c EXIST OH LOT T3) UPPLY ( LOT 121 — ,� LOT 11 1 v FORT VALE INC (126 N VIRGINIA) HCAD 0,023 257 082 0006 — LOTS 6-9 - 16' ALLEY ' —s—s—S—s—s I I RUSSELL 'W LUNDSFORD (211 E 1,1A1" HCAD 402325%0820004 LOTS 4&5 I I I ( I I I I ( I ( I L�I II i I.OT 5— I LOT 4 �- EXISTING ELEVATION - -I-x.xx PROPOSED ELEVATION VV LOT 10 W Q LOT 9 — — — LOT 8 LOT 7 1 R USSq-L W LUNDSFORD DEUTSCHE BANK (211 r. MAI;N) (2C3 E RAIN) HCAD ,4,023257O820D27 HCAD #023257U820UC1 LOT 3 Lois 1&2 1 LOT 6 6' C L GATE I I I I PROPOSED 1 6' C.L FENCE I I I ( ( I 1 LLOT 3 — I LOT 2— — I LOT i SITE PLAN W/ DRAINAGE 6' C.L. (100' R.O.W.) FSSIE ARNOLD 1 '125 11 IOWA) HCAD 1023 257 062 0014 1 LOTS 145:15 I )LOT 15 EXISTING FIRE HYDRANT-�, PROPOSED 4' EXISTING 6' SAN SEWER W/6' CLEAN 1 C.L. FENCE OUT AND SAMPLE WELL PROPOSED OHS ELEC SERVICE , , 1 i.46 SIDE SB / 5 SIDE ° 119 N IOWA PROPOSED ; UILDI ° ° 0 40' XB100' (4 000 SF) �- — ' LOT 77 ° FF = 12.0 FF = 720 i 1, d �114 11.4 .n ° _ ° ° ° 11 PS ° a w' ° x PDUMIP1 HC < PRSPOSED 6' CL 4 ° ° ° d 11.2 'ENCLO UR � d a 4 GATE & FENCE - � < SWALE d {b' ° 09 ° S _ 4 . \.6 V . h°. . PROPOSE CONCRETE ° " e SURF�1 E TO BE a . 1 5' .W/. #4 . BAR @ 18' EW, ° 11.2- ° q' ° ad 1= LOT 20 q 11 PS ° ° 1 HC <. a° dg 'g d a I ..°. IG X.Iw x <. d 11.4. 12 a ° 11 10 c 9 B S' B' d ° .d 11.4 ..LOT 21OWA j / PROPOSED BUILDING 0 40' X 100' (4,000 SF) >6 c < / BE = 120 PROPOSED OH �> 5' SIDE S0 22 ELEC SERVICE jz f 16' ALLEY,-,Z/ — I - - - - I [—X PROPOSED 4' SAN / SEWER W/6" / Ti EXIST OH x CLEAN OUT AND l 115 N IOWA APPLY I SAMPLE WELL I TIE SAN SEWER EXIST ELEC EXITING TO EXISTING LINE i / SUPPLY BUILDING x / 55' X 3� (1650 SF) x 1 I I )EXISTING 6'— C.L. GATE TO REMAIN I� I / i 1 215 E ST MAIN ' EXISTING BUILDING#1 / PROPOSED - DWARF 601 X 80' OLEANDERS 1(SEE I / (4000 SF) I / NOTES) I PROPO' CREPE MYR-t EXIST (SEE NOT) CONIC SLAB , / EXISTING C.L. GATE 1 I / 1 PROPOSED MAGNOLIA / i DENOTES) LOT 26 ( L•OT 25 • • • • • • , , I, 'LQT 24.. , , , , . LOT 23 I LOT 22 EXIST DRIVEWAY le i PROPOSED I `, � BLDG & I FOUNDATION ati EXIST. RCP 0— SC EL PROPERTY LINE; i ii j 0' FRONT SET BACK LINE SAN SEWER EXIST LINE I ,�?^I I )POSED `i-' �l L yh CID 3- �> O Q U w a; z> Io ® CXD �I 1 OH Y mh CREPE MYRTLE, BEYOND DWARF OLEANDERS SITE zzZ ix z _ East 4a Poate �Ap 1 ' r A4§Tri> Sr �' X� ? ' �m N G 'lY ` o tit 4v: AOtkst WA W Q {Hs Co ,. a C3� s i 14i) # tti� `s ' W D St SECTION A - A SCALE:NONE 07 VICINITY MAP KEY MAP #540Y LANDSCAPING: TOTAL AREA OF DEVELOPMENT = 19,875 SF VICINITY MAP SCALE: NONE 06 BUILDING AREA = 8,000 SF 19,875 SF - 8,000 SF = 11,875 SF, 11,875 SF X 6% = 712 SF, LANDSCAPE PROVIDED = 1,028 SF, SCOPE OF WORK INCLUDES: DWARF OLEANDERS (40), 5 GAL MIN, CREPE MYRTLES (13), 6' HEIGHT MIN, PROPOSED WORK CONSISTS OF CONSTRUCTION MAGNOLIA TREE (1), 6' HEIGHT MIN, OF A PRIMARY OFFICE/WAREHOUSE BUILDING FOR A SPECIALTY CONTRACTOR WITH FUTURE x ADDITIONAL LANDSCAPING INCORPORATES 4— 4' WIDE INTERIOR LAYOUTS, A SECOND PROPOSED 40'X100' (822 SF) PLANTING BEDS LOCATED ON E MAIN STREET, STRUCTURE WILL PRESUME IN THE NEAR FUTURE, AT THE CORNER OF E MAIN AND NORTH IOWA AND ADDITIONAL LANDSCAPING WILL BE INSTALLED ON NORTH IOWA STREETS, AT THE CORNER OF EAST MAIN STREET AND NORTH IOWA PER PLANNING DEPARTMENT DIRECTION, NOTE: ALL PROPOSED LANDSCAPING SHALL BE IRRIGATED WITH GENERAL NOTES APPROVED BACK FLOW PREVENTION DEVICE. SEPARATE PERMIT REQUIRED FOR IRRIGATION SYSTEM. 1, THIS SITE PLAN WAS DEVELOPED IN PART FROM A SURVEY PROVIDED BY SOUTH TEXAS SURVEYING ASSOCIATES, INC,, LANDSCAPE NOTES SCALE: NONE 05 DATED 2-2-2005, JOB #90-05. THIS IS TO CERTIFY THAT THE CITY OF LA PORTE, TEXAS HAS APPROVED 2, THIS PROPERTY DOES NOT LIE IN THE 100 THIS SITE PLAN DEVELOPMENT OF I & J PROPERTIES IN CONFORMANCE YEAR FLOOD PLAIN ACCORDING TO FLOOD WITH THE ORDINANCES OF THE CITY OF LA PO TE, INSURANCE RATE MAP #4854870945L, DATED &�#II6118,07 AND IS IN ZONE 'X', LA PORTE CITY ENGINEER III BY:AiNI ECT LLA POR A3, EXISTING FIRE HYDRANT LOCATED 85' ESE FROM SE A PLANNING DEPARTMENT CORNER OF PROPOSED PROJECT IN THE R,O,W, OF WEST 'B' STREET, SITE PLAN ACCURACY CERTIFICATE 5, HCAD #023 257 082 0016 #023 257 082 0020 I, WILLIAM T. MANNING, JR„ AM REGISTERED UNDER THE LAWS OF THE STATE OF TEXAS TO PRACTICE THE PROFESSION OF 6, LEGAL DESCRIPTION: LOTS 16-21, BLOCK 182, TOWN OF ENGINEERING AND HEREBY CERTIFY THAT THE ABOVE PLAT OR SITE LA PORTE, RABBIS COUNTY, TEXAS, PLAN IS TRUE AND CORRECT; AND THAT ALLBEARINGS, DISTANCES, ANGLES, CURVE RADIUSES, AND CENTRAL ANGLES ARE ACCURATELY SHOWN ON THE PLAT, GENERAL CONTRACTORS: COMPLETE ELECTRICAL SERVICES BYI //k 7_215 NORTH IOWA STREET WILLIAM T, MANNING, J „ E, LA PORTE, TX 77571 TEXAS REGISTRATION NO, 80640 MANNING ENGINEERING CORPORATION, F-2630 ZONED: MAIN STREET DISTRICT (MSD) CERTIFICATIONS 04 OWNERS: SCALE: NONE I & J PROPERTIES P O BOX 512 LEGEND SEABROOK, TX 77586-0512 a—S SANITARY SEWER (SIZE NOTED) PARKING CALCULATIONS) a W -� WATER LINE (SIZE NOTED) 2 GNATURAL GAS LINE (SIZE NOTED) PROPOSED BUILDING: 2 —E OH ELEC POWER LINES 2,400 SQ FT OFFICE/WAREHOUSE 6' CHAIN LINK FENCE —SPECIALTY CONTRACTOR: 2 UE UG ELEC POWER LINES 4 (MIN) + 1 PER 3 NON —OFFICE EMPLOYEES (8) = 7 —PL PROPERTY LINE STORM SEWER TOTAL REQUIRED PARKING SPACES= 6 & 1 HC ACCESSIBLE TREE — MAGNOLIA (1) 2" CAL. MIN. �___--------SHRUBS — DWARF OLEANDER (40) 5 GAL. MIN. TREES — CREPE MYRTLES (13) 6' HGT, MIN. SCALE: 1"=20' 1 03 1 LEGEND SCALE: NONE ( 02 I NOTES SCALE: NONE I 01 1 planning - design - execution - P O B o x 8 7 3 La Porto, Toxas 775t750 Office/Fax: (281) 887-9820 Cell: (713) 489-7750 www.projectdesignpartners.com PROJECT NUMBER PROJECT TITLE U Z QLO w / I,.,. Uj (` H Uj >o W O- O 0 n w — F- 06QUo ®I_Zo- 0. J Q U PROFESSIONAL SEAL WIJAM T. MANNING, JP. 3, aosao" I LICENSE S et 7 / DRAWINGS ISSUED FOR: OWNER APPROVAL PROGRESS PRINT FINAL PRINT REVISIONS NO. DATE DESCRIPTION z 3 SCOPE OF THE DOCUMENT THIS DRAWING INDICATES THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPT, THE DIMENSIONS OF THE BUILDING, THE MAJOR ARCHITECTURAL ELEMENTS AND THE TYPE OF STRUCTURAL, MECHANICAL ELECTRICAL SYSTEMS. AS SCOPE DOCUMENTS, THE DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REOUIREMENTS OF THE CONTRACT DOCUMENTS, ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, THE CONTRACTOR SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. THESE DRAWINGS SHALL NOT BE USED FOR CONSTRUCTION UNLESS DATED AND NOTED AS ISSUED FOR CONSTRUCTION WORK. THIS DOCUMENT IS THE PROPERTY OF AND IS NOT TO BE USED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN AUTHORIZATION OF WARN■NG IF THIS BAR DOES NOT MEASURE 1'THEN DRAWING IS NOT TO SCALE DRAWN BY: CHECKED DPL BY: DATE 2010/05/26 SHEET TITLE SITE PLAN W/ NOTES DRAtVING NUMBER SHEET N0. 1.1 o9- Saa 3