HomeMy WebLinkAboutI & J PROPERTIES CAPITAL IMPROVEMENTS SITE PLANPORT VALE INC
(126 N VIRGINIA)
HCAD ¢023 257 082 0010
LOTS I0-1'S
(60' R.O.W.)
L—c
EXIST OH LOT T3)
UPPLY
(
LOT 121
— ,� LOT 11
1
v
FORT VALE INC
(126 N VIRGINIA)
HCAD 0,023 257 082 0006
— LOTS 6-9 -
16' ALLEY '
—s—s—S—s—s
I I
RUSSELL 'W LUNDSFORD
(211 E 1,1A1"
HCAD 402325%0820004
LOTS 4&5
I I
I (
I I
I I
( I
( I
L�I II
i I.OT 5— I LOT 4
�- EXISTING ELEVATION
- -I-x.xx PROPOSED ELEVATION
VV
LOT 10
W
Q
LOT 9
— — —
LOT 8
LOT 7 1
R USSq-L W LUNDSFORD DEUTSCHE BANK
(211 r. MAI;N) (2C3 E RAIN)
HCAD ,4,023257O820D27 HCAD #023257U820UC1
LOT 3 Lois 1&2
1 LOT 6
6' C L GATE I
I
I I
PROPOSED
1 6' C.L FENCE
I
I I (
( I 1
LLOT 3 — I LOT 2— — I LOT i
SITE PLAN W/ DRAINAGE
6' C.L.
(100' R.O.W.)
FSSIE ARNOLD 1
'125 11 IOWA)
HCAD 1023 257 062 0014
1 LOTS 145:15
I
)LOT 15 EXISTING FIRE HYDRANT-�,
PROPOSED 4'
EXISTING 6' SAN SEWER W/6' CLEAN 1
C.L. FENCE OUT AND SAMPLE WELL
PROPOSED OHS
ELEC SERVICE , ,
1 i.46 SIDE SB / 5 SIDE
° 119 N IOWA
PROPOSED ;
UILDI
° ° 0 40' XB100' (4 000 SF)
�- —
' LOT 77
° FF = 12.0 FF = 720 i
1, d �114 11.4
.n
° _ °
° ° 11 PS
°
a w' ° x PDUMIP1 HC
< PRSPOSED 6' CL 4 ° ° ° d 11.2
'ENCLO UR � d a 4 GATE & FENCE - � <
SWALE
d {b' ° 09 ° S _ 4 . \.6 V .
h°. . PROPOSE
CONCRETE °
" e SURF�1 E TO BE a .
1 5' .W/. #4 . BAR @ 18' EW, ° 11.2-
° q' ° ad
1=
LOT 20 q 11 PS ° ° 1 HC
<. a°
dg 'g d a I ..°. IG X.Iw
x <. d
11.4. 12 a ° 11 10 c 9 B S' B' d °
.d 11.4
..LOT 21OWA
j
/ PROPOSED
BUILDING
0 40' X 100' (4,000 SF)
>6
c < / BE = 120 PROPOSED OH
�> 5' SIDE S0 22 ELEC SERVICE jz
f
16' ALLEY,-,Z/
—
I -
- - -
I
[—X
PROPOSED 4' SAN
/
SEWER W/6"
/
Ti
EXIST OH
x CLEAN OUT AND
l
115 N IOWA
APPLY
I
SAMPLE WELL I TIE SAN SEWER
EXIST
ELEC
EXITING
TO EXISTING LINE
i
/
SUPPLY
BUILDING
x
/
55' X 3� (1650 SF)
x
1
I
I
)EXISTING 6'—
C.L. GATE
TO REMAIN
I�
I
/
i
1
215 E ST MAIN
' EXISTING BUILDING#1
/
PROPOSED -
DWARF
601 X 80'
OLEANDERS
1(SEE
I
/ (4000 SF)
I
/
NOTES)
I
PROPO'
CREPE MYR-t
EXIST
(SEE NOT)
CONIC SLAB
,
/
EXISTING
C.L.
GATE
1
I
/
1 PROPOSED
MAGNOLIA
/
i
DENOTES)
LOT 26
(
L•OT 25 • • • • • • , , I, 'LQT 24.. , , , , .
LOT 23
I LOT 22
EXIST
DRIVEWAY
le
i PROPOSED I `,
� BLDG & I
FOUNDATION
ati EXIST. RCP 0—
SC
EL
PROPERTY LINE; i ii
j 0' FRONT SET
BACK LINE
SAN SEWER
EXIST LINE I ,�?^I
I
)POSED `i-'
�l
L yh
CID 3-
�> O
Q
U w a;
z>
Io
® CXD
�I
1
OH
Y
mh
CREPE MYRTLE,
BEYOND
DWARF OLEANDERS
SITE
zzZ
ix z
_
East 4a Poate
�Ap
1
'
r
A4§Tri> Sr
�'
X�
? '
�m
N G
'lY ` o tit
4v:
AOtkst
WA
W
Q
{Hs
Co
,.
a
C3�
s
i
14i)
#
tti�
`s
'
W D St
SECTION A - A SCALE:NONE 07 VICINITY MAP KEY MAP #540Y
LANDSCAPING:
TOTAL AREA OF DEVELOPMENT = 19,875 SF VICINITY MAP SCALE: NONE 06
BUILDING AREA = 8,000 SF
19,875 SF - 8,000 SF = 11,875 SF,
11,875 SF X 6% = 712 SF,
LANDSCAPE PROVIDED = 1,028 SF, SCOPE OF WORK
INCLUDES: DWARF OLEANDERS (40), 5 GAL MIN,
CREPE MYRTLES (13), 6' HEIGHT MIN, PROPOSED WORK CONSISTS OF CONSTRUCTION
MAGNOLIA TREE (1), 6' HEIGHT MIN, OF A PRIMARY OFFICE/WAREHOUSE BUILDING
FOR A SPECIALTY CONTRACTOR WITH FUTURE
x ADDITIONAL LANDSCAPING INCORPORATES 4— 4' WIDE INTERIOR LAYOUTS, A SECOND PROPOSED 40'X100'
(822 SF) PLANTING BEDS LOCATED ON E MAIN STREET, STRUCTURE WILL PRESUME IN THE NEAR FUTURE,
AT THE CORNER OF E MAIN AND NORTH IOWA AND ADDITIONAL LANDSCAPING WILL BE INSTALLED
ON NORTH IOWA STREETS, AT THE CORNER OF EAST MAIN STREET AND NORTH IOWA PER
PLANNING DEPARTMENT DIRECTION,
NOTE: ALL PROPOSED LANDSCAPING SHALL BE IRRIGATED WITH GENERAL NOTES
APPROVED BACK FLOW PREVENTION DEVICE.
SEPARATE PERMIT REQUIRED FOR IRRIGATION SYSTEM. 1, THIS SITE PLAN WAS DEVELOPED IN PART FROM A SURVEY
PROVIDED BY SOUTH TEXAS SURVEYING ASSOCIATES, INC,,
LANDSCAPE NOTES SCALE: NONE 05 DATED 2-2-2005, JOB #90-05.
THIS IS TO CERTIFY THAT THE CITY OF LA PORTE, TEXAS HAS APPROVED 2, THIS PROPERTY DOES NOT LIE IN THE 100
THIS SITE PLAN DEVELOPMENT OF I & J PROPERTIES IN CONFORMANCE YEAR FLOOD PLAIN ACCORDING TO FLOOD
WITH THE ORDINANCES OF THE CITY OF LA PO TE, INSURANCE RATE MAP #4854870945L, DATED
&�#II6118,07 AND IS IN ZONE 'X',
LA PORTE CITY ENGINEER III
BY:AiNI ECT LLA POR A3, EXISTING FIRE HYDRANT LOCATED 85' ESE FROM SE
A
PLANNING DEPARTMENT CORNER OF PROPOSED PROJECT IN THE R,O,W, OF
WEST 'B' STREET,
SITE PLAN ACCURACY CERTIFICATE 5, HCAD #023 257 082 0016
#023 257 082 0020
I, WILLIAM T. MANNING, JR„ AM REGISTERED UNDER THE LAWS OF
THE STATE OF TEXAS TO PRACTICE THE PROFESSION OF 6, LEGAL DESCRIPTION: LOTS 16-21, BLOCK 182, TOWN OF
ENGINEERING AND HEREBY CERTIFY THAT THE ABOVE PLAT OR SITE LA PORTE, RABBIS COUNTY, TEXAS,
PLAN IS TRUE AND CORRECT; AND THAT ALLBEARINGS, DISTANCES,
ANGLES, CURVE RADIUSES, AND CENTRAL ANGLES ARE ACCURATELY
SHOWN ON THE PLAT, GENERAL CONTRACTORS:
COMPLETE ELECTRICAL SERVICES
BYI //k 7_215 NORTH IOWA STREET
WILLIAM T, MANNING, J „ E, LA PORTE, TX 77571
TEXAS REGISTRATION NO, 80640
MANNING ENGINEERING CORPORATION, F-2630 ZONED:
MAIN STREET DISTRICT (MSD)
CERTIFICATIONS 04 OWNERS:
SCALE: NONE I & J PROPERTIES
P O BOX 512
LEGEND SEABROOK, TX 77586-0512
a—S SANITARY SEWER (SIZE NOTED) PARKING CALCULATIONS)
a W -� WATER LINE (SIZE NOTED)
2 GNATURAL GAS LINE (SIZE NOTED) PROPOSED BUILDING:
2 —E OH ELEC POWER LINES 2,400 SQ FT OFFICE/WAREHOUSE
6' CHAIN LINK FENCE —SPECIALTY CONTRACTOR:
2 UE UG ELEC POWER LINES 4 (MIN) + 1 PER 3 NON —OFFICE EMPLOYEES (8) = 7
—PL PROPERTY LINE
STORM SEWER TOTAL REQUIRED PARKING SPACES= 6 & 1 HC ACCESSIBLE
TREE — MAGNOLIA (1) 2" CAL. MIN.
�___--------SHRUBS — DWARF OLEANDER (40)
5 GAL. MIN.
TREES — CREPE MYRTLES (13)
6' HGT, MIN.
SCALE: 1"=20' 1 03 1 LEGEND
SCALE: NONE ( 02 I NOTES
SCALE: NONE I 01 1
planning - design - execution -
P O B o x 8 7 3
La Porto, Toxas 775t750
Office/Fax: (281) 887-9820 Cell: (713) 489-7750
www.projectdesignpartners.com
PROJECT NUMBER
PROJECT TITLE
U
Z
QLO
w / I,.,.
Uj (`
H Uj
>o
W O-
O 0
n
w
— F-
06QUo
®I_Zo-
0. J
Q
U
PROFESSIONAL SEAL
WIJAM T. MANNING, JP.
3, aosao"
I LICENSE
S et 7 /
DRAWINGS ISSUED FOR:
OWNER APPROVAL
PROGRESS PRINT
FINAL PRINT
REVISIONS
NO.
DATE
DESCRIPTION
z
3
SCOPE OF THE DOCUMENT
THIS DRAWING INDICATES THE GENERAL SCOPE OF THE
PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPT, THE
DIMENSIONS OF THE BUILDING, THE MAJOR ARCHITECTURAL
ELEMENTS AND THE TYPE OF STRUCTURAL, MECHANICAL
ELECTRICAL SYSTEMS. AS SCOPE DOCUMENTS, THE
DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL
WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION
OF THE REOUIREMENTS OF THE CONTRACT DOCUMENTS, ON
THE BASIS OF THE GENERAL SCOPE INDICATED OR
DESCRIBED, THE CONTRACTOR SHALL FURNISH ALL ITEMS
REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF
THE WORK. THESE DRAWINGS SHALL NOT BE USED FOR
CONSTRUCTION UNLESS DATED AND NOTED AS ISSUED FOR
CONSTRUCTION WORK. THIS DOCUMENT IS THE PROPERTY
OF AND IS NOT TO BE USED, IN
WHOLE OR IN PART, WITHOUT THE WRITTEN AUTHORIZATION OF
WARN■NG
IF THIS BAR DOES NOT MEASURE 1'THEN DRAWING IS
NOT TO SCALE
DRAWN BY: CHECKED
DPL
BY:
DATE
2010/05/26
SHEET TITLE
SITE
PLAN W/
NOTES
DRAtVING NUMBER
SHEET N0.
1.1
o9- Saa 3