Loading...
HomeMy WebLinkAboutPOND TO PARK PROJECT= 3 LLI Cp W 3 �C) % N O O N 04 �? o O vCL LOCATION MAP NTS BLUE BIR 3p �? ROBIN H A' � N H o w x Q- LA PORTE ID pto MUNICIPAL AIRPORT Cu MAPLE F < ARCHWAY FLINTROC a CREE C A S 9p PARKCRES D °A �PF �n F n Y �0 3 GLENVIE y o a CRESTWA NOT TO S I � � w VALLEY R CREE w z MEADOW I ST E CREE J 3 GLENVALL Y > MEAD W CREST SPENCER CREEKVIE SPENCER HIGHWAY OLD ANTRI RCHAR CA LETT BELFPS BELFAST LOW yR�o 2 LYNWOOD LA P O R T E CAR DO ER y WINDING DOGWOOD ONE ONT ONT ILLRID a wIN C���I ING O IDLEWOOD MULBERRY Pop 27,910 WIL Cy9Q O HIL RMoyT 3w Fairmont QUI�I7D P OLLINGSWO PROJECT 4GPR arkRCH SST cT GAT LOCATION AKM NT G� r MESQUITE Ao RUS I Sti RpG� ~ � RUSTIC R SH �C PECAN 3 �-p��( 3 0 0 P1 M w cKy R o � o ow 3 w y �' El o Z ROCKY r i u ROSEBE Y PKWY ~ a FAIRMONT LIMIT VICINITY MAP NTS KEY MAP NO. 579 C&D POND TO PARK PROJECT FAIRMONT PARK EASTSU DIVISION HARRIS COUNTY 604 W. Fairmont Parkway La Porte, Texas 77571 SHEET INDEX 1 COVER 2 GENERAL NOTES 3 PHASE ONE DETENTION POND SITE PLAN 4 DETENTION POND TYPICAL CROSS SECTIONS 5 PHASING PLAN FOR ENHANCED FEATURES 6 PARKING LOT PAVING PLAN 7 PARKING LOT DIMENSIONAL CONTROL PLAN 8 PARKING LOT GRADING AND DRAINAGE PLAN 9 PAVING DETAILS 10 STORM SEWER DETAILS 11 WATER LINE DETAILS 12 STORM WATER POLLUTION PREVENTION PLAN 13 STORM WATER POLLUTION PREVENTION DETAILS 14 PRECAST SAFETY END TREATMENT DETAILS 15 RETAINING WALL LAYOUT 16 RETAINING DETAILS (1 OF 2) 17 RETAINING DETAILS (2 OF 2) DIRECTOR OF PLANNING DATE SIGNATURE IS VALID FOR ONE YEAR FROM DATE SHOWN. CivilTech Engineering, Inc. 11821 Telge Road Cypress, Texas 77429 (281) 304-0200 Fax (281) 304-0210 REVISIONS NO. REVISION / ISSUE DATE GENERAL NOTES 1. SURFACE RESTORATION AT THE END OF ALL CONSTRUCTION PROJECTS, THE CONTRACTOR SHALL RESTORE EXISTING FACILITY (I.E. PROPERTY) EQUAL TO OR BETTER THAN EXISTING SITE CONDITIONS PRIOR TO CONSTRUCTION. 2. THE LOADING AND UNLOADING OF ALL PIPE VALVES, HYDRANTS, MANHOLES AND OTHER ACCESSORIES SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED PRACTICES AND SHALL AT ALL TIMES BE PERFORMED WITH CARE TO AVOID ANY DAMAGE TO THE MATERIAL. THE CONTRACTOR SHALL LOCATE AND PROVIDE THE NECESSARY STORAGE AREAS FOR MATERIALS AND EQUIPMENT. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFEGUARDING AND PROTECTING ALL MATERIAL AND EQUIPMENT STORED ON THE JOBSITE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE STORAGE OF MATERIALS IN A SAFE AND WORKMANLIKE MANNER TO PREVENT INJURIES, DURING AND AFTER WORKING HOURS, UNTIL PROJECT COMPLETION. 4. CONTRACTOR SHALL PROVIDE SHEETING, SHORING AND BRACING AS NECESSARY TO PROTECT WORKMEN AND EXISTING UTILITIES DURING ALL PHRASES OF CONSTRUCTION, AS PER O.S.H.A. REQUIREMENTS. 5. ALL TESTING PROCEDURES USED ON THIS PROJECT SHALL CONFORM TO THE CITY OF LA PORTE STANDARDS. IF ANY OF THE TEST RESULTS DO NOT MEET THE TESTING STANDARDS, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO REMOVE OR REPLACE SUCH MATERIAL SO THAT THE TESTING STANDARDS CAN BE MET. 6. ALL FINISHED GRADES SHALL VARY UNIFORMLY BETWEEN FINISHED ELEVATIONS. 7. CONTRACTOR SHALL UNCOVER EXISTING UTILITIES AT ALL "POINTS OF CROSSING" TO DETERMINE IF CONFLICTS EXIST BEFORE COMMENCING ANY CONSTRUCTION. NOTIFY THE DESIGN ENGINEER AT ONCE OF ANY CONFLICT. 8. TOP OF FOUNDATION (SLAB) SHALL BE A MINIMUM OF 12" ABOVE TOP OF CURB AND/OR 18" ABOVE THE CROWN OF ROAD IN ROADSIDE DITCH CONSTRUCTION AREAS OR 2' ABOVE 100 YR FLOOD ELEVATION, WHICHEVER IS HIGHER. 9. THE CONTRACTOR SHALL NOT UNLOAD ANY TRACK -TYPE CONSTRUCTION MACHINERY ON ANY EXISTING PAVEMENT OR CROSS OVER ANY EXISTING PAVEMENT OR CURB DURING ANY PROJECT. 10. IF IT IS PERMISSIBLE TO USE A BACKHOE FOR TRENCH EXCAVATION IN LIEU OF A TRENCHING MACHINE. 11. CONTRACTOR SHALL NOTIFY CITY OF LA PORTE PUBLIC IMPROVEMENTS COORDINATOR AT 281-471-5020 X293 TO HAVE AN INSPECTION. 12. THE CITY OF LA PORTE REQUIRES 48 HOURS NOTICE PRIOR TO COMMENCING WORK IN THE CITY'S R.O.W. 13. CONTRACTORS CANNOT USE THE CITY'S R.O.W. FOR STORAGE OF CONSTRUCTION MATERIALS. 14. ALL BACKFILL SHALL BE ENGINEERED TO 95% STANDARD PROCTOR DENSITY AND BE TESTED BY AN APPROVED TESTING LAB. 15. CONTACT CITY OF LA PORTE PUBLIC WORKS DEPARTMENT PRIOR TO MAKING TIE-INS TO EXISTING UTILITIES. 16. WHEN HYDROMULCH IS REQUIRED, CONTRACTOR SHALL KEEP MULCH MOIST AFTER INSTALLATION AND UNTIL AREA SHOWS GROWTH OVER 75% OF THE HYRDROMULCHED AREA. 17.48 HOURS PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL NOTIFY THE UTILITY COORDINATING COMMITTEE AT 223-4567. 18. CITY OF LA PORTE ENGINEERING DEPARTMENT SHALL APPROVE THE CONSTRUCTION LAYOUT. 19. ALL EXCESS EXCAVATED MATERIAL SHALL BECOME PROPERTY OF THE CONTRACTOR, AND REMOVE FROM SITE, AND DISPOSED OF IN A LEGAL MANNER. 20. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL COORDINATE WITH RESIDENTS WHEN INTERRUPTING EXISTING SERVICES. 21. CONTRACTOR SHALL OBTAIN AN ELECTRICAL PERMIT (WHEN NEEDED) FROM THE CITY OF LA PORTE INSPECTION DEPARTMENT PRIOR TO CONSTRUCTION. ELECTRICIAN MUST BE LICENSED BY THE CITY OF LA PORTE. ELECTRICAL INSPECTIONS SHALL BE COORDINATED WITH THE INSPECTIONS DEPARTMENT. 22. BARRICADES SHALL BE EQUIPPED WITH ORANGE FLASHING LIGHTS. 23. MANHOLES SHALL BE EQUIPPED WITH INFILTRATION INSERTS. 0+ 3 v (N W H 0 vz J 7 Q •" w Cw yl N Ci •'OQ rn C W 3 0 N �0 o N O 'M N V� PAVING NOTES 1. 6" - 5 SACK, 3000 PSI REINFORCED CONCRETE WITH #4 BARS, 24" C-C OR # 3 BARS, 18" C-C. IS THE MINIMUM ACCEPTABLE PAVEMENT CONSTRUCTION FOR THRU TRAFFIC WAYS FOR LOCAL RESIDENTIAL STREETS. 2. 7" - 5 SACK, 3000 PSI REINFORCED CONCRETE WITH #4 BARS, 24" C-C IS THE MINIMUM ACCEPTABLE PAVEMENT CONSTRUCTION FOR COLLECTOR STREETS. 3. 8" - 5 SACK, 3000 PSI REINFORCED CONCRETE WITH #4 BARS, 18" C-C IS THE MINIMUM ACCEPTABLE PAVEMENT CONSTRUCTION FOR MAJOR THOROUGH FARES. 4. 6" THICK, 6% DRY WEIGHT, IS THE MINIMUM LINE STABILIZED SUBGRADE FOR PAVEMENT SUBGRADE. 5. CONCRETE SIDEWALKS SHALL BE CONSTRUCTED WITHIN EACH STREET RIGHT-OF-WAY PER LA PORTE'S STANDARD DETAILS. 6. ALL INTERSECTIONS HSLL BE CONSTRUCTED WITH WHEEL CHAIR RAMPS IN ACCORDANCE WITH THE GOVERNOR'S OFFICE OF TRAFFIC SAFETY MEMORANDUM DATED MAY 6, 1976 (HIGHWAY SAFETY ACT - 1973 SECTION 288). 7. ALL PAVING SHALL BE IN ACCORDANCE WITH THE CITY OF LA PORTE STANDARD DETAIL SHEETS. 8. ALL RETURNS SHALL BE IN ACCORDANCE WITH PICM AND THE LA PORTE ZONING ORDINANCE. 9. WHEN 6" CONCRETE PAVED ROADWAY INTERSECTS 7" CONCRETE PAVED ROADWAY OR ROADWAY, 7" CONCRETE SHALL BE CONSTRUCTED TO ENDS OF ALL CURB RETURNS. 10. FAILURE TO MEET THE REQUIREMENTS THROUGH THE TESTING PROCEDURE WILL RESULT IN THE REJECTION OF THAT PORTION DEEMED TO BE DEFICIENT. THE PROPOSED PAVEMENT DEPTHS SHOWN ON THE PLAN DETAIL SHEETS IS CONSISTENT WITH THESE NOTES AND SHALL BE USED TO DETERMINE THE REQUIREMENT IN EACH CASE. 11. FAILURE OF PAVEMENT TO MEET THESE MINIMUM REQUIREMENTS WILL RESULT IN THE REJECTION OF PAVEMENT. IMMEDIATE REMOVAL AND REPLACEMENT OF SUBSTANDARD PAVEMENT SECTIONS WILL BE NECESSARY TO SATISFY THESE REQUIREMENTS. 12. PAVEMENTS EXCEEDING DEPTH OR STRENGTH REQUIREMENTS WILL BE ACCEPTED IF BOTH CRITERIA MEET THE MINIMUM ESTABLISHED REQUIREMENTS. 13. TRANSVERSE EXPANSION JOINTS ARE REQUIRED AT MAXIMUM SPACING OF 40'-0", C-C WITH JOINTS AND VERTICAL CURB JOINTS TO BE SEALED WITH LIQUID RUBBER CONFORMING TO TXDOT ITEM 360.2 (8)c CLASS 2 (HOT POURED RUBBER) 14. EXPANSION JOINT LAYOUT FOR INTERSECTIONS SHALL BE PROVIDED BY ENGINEER TO THE CITY. 15. DENSITY TEST TO BE RETAKEN IN THE EVENT OF A %2 " (ONE-HALF INCH) OR GREATER RAINFALL. 16. CONTRACTOR SHALL NOTIFY THE CITY OF LA PORTE PUBLIC WORKS DEPARTMENT AT 281-471-5020 48 HOURS PRIOR TO COMMENCING ANY CONSTRUCTION WITHIN RIGHT-OF-WAY. STORM SEWER NOTES 1 ALL STATIONS ARE CENTER LINE OF STREET RIGHT-OF-WAY STATIONS EXCEPT WHERE STORM SEWER IS IN SIDE LOT EASEMENTS: THIS STATIONING IS BASED ON CENTERLINE OF PIPE. 2. STORM SEWERS SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY OF LA PORTE STANDARD DETAILS SHALL BE OBSERVED. 3. ALL STORM SEWER 18" AND LARGER TO BE REINFORCED CONCRETE RUBBER GASKET PIPE, A.S.T.M. C-76 CLASS III, INCLUDING INLET LEADS CROSSING UNDER EXISTING OR PROPOSED PAVEMENT. 4. REINFORCED CONCRETE PIPE STORM SEWER SHALL BE INSTALLED, BEDDED AND BACKFILLED IN CONFORMITY WITH CITY OF LA PORTE STANDARD DETAIL SHEETS. BACKFILL UNDER OR WITHIN V (ONE FOOT) OF EXISTING OR PROPOSED PAVEMENT WITH CEMENT STABILIZED SAND (1-% SACKS PER CUBIC YARD MIX). ALL NORMALLY SUBMERGED STORM PIPE SHALL BE RUBBER GASKETED. 5. CONTRACTOR SHALL PROVIDE A MINIMUM OF 6" (SIX INCHES) CLEARANCE AT STORM SEWER AND WATER LINE CROSSINGS, AND A MINIMUM OF 1 FOOT (TWELVE INCHES) AT STORM SEWER AND SANITARY SEWER CROSSINGS. 6. ALL STORM SEWER MANHOLES SHALL BE CITY OF LA PORTE TYPE "C" UNLESS OTHERWISE NOTED AND SHALL BE LOCATED A MINIMUM OF 3' BACK OF CURB. 7. ALL INLET TYPE TO BE CLEARLY NOTED AND GRATE TYPE INLETS SHALL BE EQUIPPED WITH CAST IRON GRATES. 8. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING LOCATION OF ALL EXISTING UTILITIES PRIOR TO EXCAVATION. 9. MINIMUM STORM SEWER SIZE IS 18" INCH DIAMETER IN PUBLIC R.O.W. & EASEMENTS. 10. ALL STORM SEWER MANHOLE COVERS MUST INCLUDE THE WORD "STORM SEWER." 11. CULVERTS MUST MATCH EXISTING FLOW LINES. WATER DISTRIBUTION NOTES 1. ALL STATIONS ARE CENTERLINE OF STREET RIGHT-OF-WAY STATIONS EXCEPT WATER LINE STATIONING IN SIDE LOT EASEMENTS. THIS STATIONING IS BASED ON CENTERLINE OF PIPE. 2. WATER MAINS SHALL BE CONSTRUCTED ACCORDING TO CITY OF LA PORTE STANDARD DETAIL SHEETS. 3. ALL FLUSHING VALVES ARE TO BE LOCATED AS SHOWN ON PLANS AND SET 3' (THREE FEET) BEHIND BACK OF CURB OR AT APPROVED LOCATIONS. 4. ALL WATER MAINS TO HAVE MINIMUM OF 4' (FOUR FEET) COVER FROM PROPOSED TOP OF CURB WHEN CONSTRUCTED IN STREET RIGHT-OF-WAY AND 4' (FOUR FEET) COVER FROM FINISHED GRADE WHEN CONSTRUCTED WITHIN EASEMENTS. 5. CONTRACTOR SHALL PROVIDE FOR A MINIMUM HORIZONTAL CLEARANCE OF 10, (TEN FEET) BETWEEN WATER MAINS AND SANITARY SEWER LINES. 6. ALL GATE VALVES TO BE COUNTERCLOCKWISE OPENING AND ALL FLUSHING VALVES TO BE COUNTERCLOCKWISE OPENINGS, VALVES TO BE LOCATED OPPOSITE PROPERTY LINE OR R.O.W. LINE EXTENDED UNLESS OTHERWISE SHOWN ON PLANS. AWWA GATE VALVES WITH RESILIENT SEATS SHALL BE INSTALLED. 7. ALL VALVES AND HYDRANTS SHALL BE STORED SO THAT THEY ARE PROTECTED FROM FREEZING. ALL PIPE SHALL BE KEPT FREE OF DIRT AND OTHER DEBRIS. ANY DAMAGE RELATING TO THE COATING OF THE VARIOUS MATERIALS FOR SEWER AND WATER LINE MAINS SHALL BE RAPIDER. 8. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING LOCATION OF ALL EXISTING UTILITIES PRIOR TO EXCAVATION. 9. ALL SINGLE WATER SERVICE LEADS TO BE % INCH (MIN.). ALL WATER SERVICE LEADS TO EXTEND TO OPPOSITE PROPERTY LINE AT COMMON LOT LINE UNLESS OTHERWISE SHOWN ON PLANS. 10. NO CONNECTIONS SHALL BE MADE TO EXISTING WATER LINES UNTIL ALL PROPOSED WATER LINES HAVE BEEN THOROUGHLY CLEANED, TESTED, DISINFECTED AND APPROVED BY THE ENGINEER. 11. METAL WATER LINE FITTINGS TO BE WRAPPED WIT 6 MIL. POLYETHYLENE (MIN.) IN ACCORDANCE WITH ANSI/ASSA C105 REQUIREMENTS. 12. USE MATERIALS IN ACCORDANCE WITH THE PUBLIC IMPROVEMENTS CRITERIA MANUAL (PICM). 13. WATER MAIN SIZES SHALL CONFORM TO THE REQUIREMENTS OF THE PICM. 14. EVERY WATER OUTLET SHALL BE PROTECTED FROM BACKFLOW. 15. PIPE AND FITTINGS CANNOT HAVE MORE THAN 8.0% LEAD. 16.160 PSI AND 73' F IS THE MINIMUM WORKING PRESSURE OF PLASTIC PIPE OUTSIDE OF THE FOUNDATION WALLS. 17. WATER SERVICE PIPE SHALL BE MARKED WITH PERMANENT IDENTIFICATION MARKINGS. 18. WATER PIPE SHALL NOT BE INSTALLED OR PERMITTED OUTSIDE OF A BUILDING, OR CONCEALED IN OUTSIDE WALLS OR IN ANY PLACED WHERE THEY MAY BE SUBJECT TO FREEZING TEMPERATURES, UNLESS PROVISIONS ARE MADE TO PROTECT THEM FROM FREEZING. 19. FITTINGS AND VALVES SHALL BE SECURED WITH MECHANICAL JOINT RESTRAINTS. THESE RESTRAINTS SHALL BE EBAA IRON 2000 P FOR FITTINGS AND EBAA IRON SERIES 1500 FOR PIPE JOINTS OR APPROVED EQUAL. CITY OF LA PORTE 604 W. Fairmont Parkway Planing Dept./Engineering Div. La Porte, Texas 77571 281-471-5020 civillech Engineering, Inc. 11821 Telge Road Cypress, Texas 77429 (281) 304-0200 Fax (281) 304-0210 POND TO PARK PROJECT GENERAL NOTES PROJECT NO: DRAWN: GWM 220029.10 CHECKED: EKO DATE: APPROVED: JAR JULY 2004 SCALE: SHEET: N.T.S. 2 OF 17 a C 3 T V G = a = C ij �'a C C W 3 C �C CS a �C C: C` r` C i V a REVISIONS NO. REVISION / ISSUE DATE CITY OF LA PORTE 604 W. Fairmont Parkway Planing Dept./Engineering Div. La Porte, Texas 77571 281-471-5020 civillech Engineering, Inc. 11821 Telge Road Cypress, Texas 77429 (281) 304-0200 Fax (281) 304-0210 POND TO PARK PROJECT PHASE ONE DETENTION POND SITE PLAN PROJECT NO: DRAWN: GWM 220029.10 CHECKED: EKO DATE: APPROVED: JAR JULY 2004 SCALE: SHEET: 1"-40' 3OF 17 REVISIONS NO. REVISION / ISSUE DATE FL+C rn 3 v V) Z 0 =N _N VjV) _of •� U Cj rn C W 30 =i N �0 o N 04 0 0 i VCL i n' LFIL AFL+0.5' 12" RIP RAP SECTION A —A SCALE: 1 "=10' H 1 "=4' V VARII DETENTION POND CUTIFILL QUANTITIES CUT = 8845 CY FILL = 3888 CY NET = 4958 CY (CUT) in, SECTION B—B SCALE: 1 "=10' H 1 "=4' V F0.7' 20 16 12 8 4 20 16 12 8 4 20 16 m� v/—IEK1s'nNG G O ND YTFORM U Q 3 P OP FI IS ED GRADE Z Z Q W 0 20 40 60 80 100 120 140 160 180 200 220 240 SECTION C—C SCALE: 1 "=40' H 1 "=4' V 20 0 J 016 ='1 U Q 8 4 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 40( SECTION D—D SCALE: 1 "=40' H 1 "=4' V 20 S 16 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 40( SECTION E—E SCALE: 1 "=40' H 1 "=4' V NOTES: 1. PROJECT BENCHMARK TO BE ESTABLISHED BY THE CITY OF LAPORTE. CONTRACTOR TO COORDINATE WITH CITY PRIOR TO COMMENCEMENT OF CONSTRUCTION. 2. DESIGN VOLUME & WATER SURFACE ELEVATION ARE REFERENCED FROM RECORD DRAWINGS FOR FAIRMONT PARK EAST —SECTION SIX, SHEET 5 DETENTION PLAN, PREPARED BY GULF COAST ENGINEERING AND SURVEYING DATED 3-3-99. DESIGN WATER SURFACE HAS BEEN ADJUSTED BY —0.7' DUE TO DIFFERENCE IN SURVEY DATUM. CITY OF LA PORTE 604 W. Fairmont Parkway Planing Dept./Engineering Div. La Porte, Texas 77571 281-471-5020 chillrech Engineering, Inc. 11821 Telge Road Cypress, Texas 77429 (281) 304-0200 Fax (281) 304-0210 POND TO PARK PROJECT DETENTION POND TYPICAL CROSS SECTIONS [DATE: ROJECT NO: DRAWN: GWM 220029.10 CHECKED: EKO APPROVED: JARJULY 2004 CALE: SHEET: AS NOTED 4 OF 17 STM MH N.RIM=18.83 N.48"IE=11.43 E.60"IE=11.43 W.60"IE=11.43 60" RCP STM MH N.RIM=18.74 S.48"IE=11.54 E.36"IE=11.54 W36"IE=11.54 0 0 N a Q 3 v z J V � C c� -z 40 C= as c C •'OA rn C W 3 0 N �o O N �04 04 0"0 0 i V� 8" WATERLINE �- CURB INLET N.RIM=17.35 THROAT=16.55 N.48"IE=12.03 S.36"IE=12.03 W.18"IE=12.03 STM MH N.RIM=18.00 N.36"IE=12.57 S.36"IE=12.57 E.18"IE=14.49 ifU SANSWR MH WOOD FENCE 0 0 Iw o 35 EXIST 14' UTIL. 34 33 IWATERFALL (PHASE THREE) l 010064jod 094, 1 \ STM MH N.RIM=19.09 N.48"IE=12.34 S.48"IE=12.34 CURB INLET N.RIM=18.75 THROAT=17.88 N.48"IE-12.53 S.36"IE=12.69 73' 32 31 I 30 WOOD MESQUITE (50' R.O.W.) 29 EXIST 8' UTIL. ESMT. EC 6 WOO PAO WOOD FENCE 28 27 26 WOOD FENCE 25 24 23 LEGEND ® PHASE TWO CONSTRUCTION PHASE THREE CONSTRUCTION ® PARK BENCH (PHASE TWO) e =1 PICNIC TABLE (PHASE TWO) 0 CHARCOAL GRILL (PHASE TWO) ® LIGHT (PHASE THREE) J WOOD FENCE • TOE TOE L=114.14' - L=61 .92' R=156.13 R� .62 1 6� 9 5.25 STA-. 1+21.24 101 iO3 STAB 2+84.07 STA: 3+95.68 H6g•� 5I22 11'W OFFSET+642.70 L STA: 0+44.90 OFFSET: 127.69 L S10�5�q OFFSET. 133.80 L OFFSET. 135.35 L S �Og"w �856 O `Y OFFSET. 130.91 L 40' 4?7' STA: 2+46.06 STA: 4+46.57 35' O�D 1� STA-. 1+04.49 _ L=128 45' OFFSET. 120.28 L OFFS 116.68 L R�g6.61 Q OFFSET. 134.77 L R=160.13 STA: 0+24.59 o OFFSET-. 102.19 L STA: 4+90.38 M a STA: 0+26.88 II INI OFFSET: 118.93 L JI N OFFSET: 80.41 L N Co W. e I 0 Nam, STAe 6+81.22 OFFSET: 77.67 L STA: 0+40.36 COY) w OFFSET° 49.02 L ■ in a 0 A j STA: 6+86.50 0 OFFSET-. 29.79 L w N c) tr � STA-. 0+44.10 OFFSET: 10.19 L 1+00 2+00 3+00 4+00 5+00 6+00 7� o f---- ---------t----� N90'00'00"E --- ------------- ---- + 10 00NSTRUCTION BASELINE W lO O Z STA: 0+34.97 n o OFFSET-. 27.32 R In N � I 6' WIDTH JOGGING TRACK STA: 0+34.59 (PHASE THREE) OFFSET. 77 3144 OFFSET: 72.62 R SEE SHEET 9 FOR TYPICAL SECTION TOP OF JOGGING TRACK ELEVATION TO STA: 4+46.56 ON MATCH FINISHED GRADE ESTABLISHED OFFSET: 104.93 CO IN PHASE ONE OFFSET: +80.4 a, o. 53 L1i4.83' STA-. 4+99.80 0 R-69.57 FFSET. 109.36 R ~ 212 STA-. 1+83.89 49 0A FFSET-. 128.63 R .�, OFFSET+ 116.10 R oa0 R=1 47.90 68920 �0 STA-. 4+16.75 60\ 0S. 101 E ® S STA-. 2+97.63 a59 y� `L9 OFFSET: 118.25 R S3• f STA: 5+52.65 STA: 0+96.90 N�1.4� 0 STA-. 2+59.44 sgb0�!-2-_-FSET: 143.68 R OFFSET-. 138.86 RFFSET-. 149.64 R �39OFFSET. 129.03 4052 gC� S SFFSET+149.51 R y. \a, STA: 3+89.75 ? 3j L��520 STFFSET: 140.39 R L�6.1� A: 1+48.40OFFSET: 134.06 R R�7)3�3' 1� 9 y6 R s162• TOE - - - - - - - - - - -- R102.16 fz I I I I I I I I --- I- ------ I I I TOEI I I I I I I I TOE I I TOP'BYCNK SOP RANK - TOP BANK EXIST 12' MAINTENANCE ACCESS 2 3 CONCRETE PARKING LOT (PHASE TWO) SEE SHEETS 6-8 FOR PLANS 2 5 WOOD FENCE 6 F'AIRgoo SEC 5 SPRINGWOOD DR. (50' R.O.W.) 7 8 9 10 WOOD FENCE WOOD FENCE J < m 0 Y Z Q m 0 Y Z m 0 N REVISIONS7"""""' NO. REVISION / ISSUE DATE CITY OF LA PO RTE 604 W. Fairmont Parkway Planing Dept./Engineering Div. La Porte, Texas 77571 281-471-5020 Civill ech Engineering, Inc. 11821 Telge Road Cypress, Texas 77429 (281) 304-0200 Fax (281) 304-0210 POND TO PARK PROJECT PHASING PLAN FOR ENHANCED FEATURES PROJECT NO: DRAWN: GWM 220029.10 CHECKED: EKO DATE: APPROVED: JAR JULY 2004 SCALE: SHEET: 1"=40' 50F 17 REVISIONS NO. REVISION / ISSUE DATE U' =Y Q _'0' •� O •'OQ rn C c W 3 0 =i N �O �04 N 04 'm 04 O O i VCL N w DETENTION POND TOE ----TOE — — ------ I TOp egNk M �QQ' EXIST 14' UTIL. ESMT. EXIST 12' MAINTENANCE ACCESS z I I 5�G 6" CURB WOOD FENCE Oo U U I FND. 1 /2" I.R. w I PROP " REINF ' CONC. I1 — ---- AVEMEN---�---- RV t I I gES E I � 20' DRAINAGE ESMT. { w 2' SAWCUT I I i w PROP ACCESSIBLE o EJ RAMP PER DETAILS 0 0 I I 6" CURB Ll O------I------I--�— HOUSE � � I I I 0 I---�--- - - - I -�--------�-- 5 M m LL 11" TALL W I I W I 1 S Z I EJ I v I EJ �' s 0 ❑ 1 1 p0 a' I PROP 6" REINF. �ONC. I �I PAVEMENT I 1 r , I FA.I of ED I I I I I a 00 ya• o v 8 6" CURB I ISTM MH N.48"IE=12.34 12"X4" CUR S.48"IE=12.34 IL a � EXIST CONC PVMT 3 STM MH W/12' X4" CONC CURBS Q CURB INLET a- N = N.36"IE=12.57 THROAT=17.88 S.36"IE=12.57 s MH S P R I N G W O O D D R. N N.48"IE=12.53 EA 8"IE=14.49 � S.36"IE=12.69 (50' R.O.W.) CURB INLET THROAT=17.63 S.18"I E=14.74 W.18"I E=14.74 LEGEND .a .a. PROPOSED 4" SIDEWALK EJ PROPOSED EXPANSION JOINT — — — — — — PROPOSED CONSTRUCTION JOINT CITY OF LA PORTE 604 W. Fairmont Parkway Planing Dept./Engineering Div. La Porte, Texas 77571 281-471-5020 civillrech Engineering, Inc. 11821 Telge Road Cypress, Texas 77429 (281) 304-0200 Fax (281) 304-0210 POND TO PARK PROJECT PARKING LOT PAVING PLAN F NO: DRAWN: GWM 0029.10 CHECKED: EKO APPROVED: JAR LY 2004 SHEET: 20' 6OF17 =Y Q 'OA � C '0' •� O yl Cj . rn C c W 3 0 _� N 0 �04 N 04 04 O O i VCL 1V DETENTION POND TOE ----TOE — -- ------ TOP ggHk M�QQ' 6' EXIST 14' UTIL. ESMT. EXIST 12' MAINTENANCE ACCESS I I SSG WOOD FENCE z 00 U �. L� , 31.5 FND. 1 /2" I.R. w LO N %�� ER` gEs L6 Ld 20' DRAINAGE ESMT. �ti o Ld I a I �� O O 0 I a 0 .-. 18' 28' N 2 .42' I I 9' HOUSE OO M BC u R2=_ 00 1 2 o � I o o o L- Co M I cn , _ 6 SPACES O 10 60 5 E ui I 11" TALLOW U S T 0 J� C ❑a. N gK w l 8 SPACES O 10' = 80' e N 1 10' 24' °0 a ----------- 00 o 1 a 8 STM MH N.48"IE=12.34 a S.48"I E=12.34 54' EXIST CONC PVMT STM MH W/12"X4" CONC CURBS CURB INLET N.RIM=16. N.36"IE=12.57 S.36"IE=12.57 CL SANSWR MH S P R I N G W O O D DR. _ THROAT=17.88 N.48"IE=12.53 E.1 8"IE=1 4.49 S.36"IE=12.69 (50' R.O.W.) CURB INLET THROAT=17.63 S.18"I E=14.74 W.18"I E=14.74 NOTE: DIMENSIONS ARE GIVEN FROM OF THE FACE OF CURB UNLESS SHOWN OTHERWISE. REVISIONS NO. REVISION / ISSUE DATE CITY OF LA PORTE 604 W. Fairmont Parkway Planing Dept./Engineering Div. La Porte, Texas 77571 281-471-5020 civillrech Engineering, Inc. 11821 Telge Road Cypress, Texas 77429 (281) 304-0200 Fax (281) 304-0210 POND TO PARK PROJECT PARKING LOT DIMENSIONAL CONTROL PLAN PROJECT NO: DRAWN: GWM 220029.10 CHECKED: EKO DATE: APPROVED: JAR JULY 2004 SCALE: SHEET: 1"=20' 7OF17 REVISIONS NO. REVISION / ISSUE DATE DETENTION POND x 14.00 15.00 ' 16.00 II � 7.00 MEW x�G TOP �� N7 18.00 6 A/yk MEC17.85± ��� o MEP17.39± MEW � Q' F, EXIST 14' UTIL. ESMT. ~m � � I G� TC 19.15 TC 19.45 z I `'� TP18.65 TP18.95 0Z UU U N w I I TC 19.50 TP19.00 TW19.40 RV TC 19.40 1 o'6 TP18.90 TC19.05 � �� P18.55 TP18.55 \ I TP18.40 MEW C' TW19.05 TC 19.15 -8-ol TP18.35 TW 1 �.80 0 TP 18.65 0 0 TW 19.50 E0//// 0 MEC18.14± TC1895 Q TP18.35 MEP17.64± TP18.45 � TC18.90 � � � TP18.40 TC10.70 OO I TC19.20 TP1 20 TC18.70 TP18.70 a I TP18.20 TC19.00 a TP18.50 00 M � I`' TC 18.80 "LL 11" TALLOW TP18.30 uj zl (TO BE TP @ 1.00% REMOVED) ;/ TP18.25 PROP TY "A" INLET Qi TC18.80 TG 17.90 TC19.25 TC19.40 TP18.30 / 18" FL 15.19 TP18.75 TP18.90 C-4I TC18.60 TC19.20 TP18.10 45L "� 18" DPE TP18.70 h�. STM SWR Q 1.00% TIC19.40 TC1/ a. N TC 1 '.80 TP18.90 TC19.65 .25 a TP "1 .`0 , ° V"TP19.15 0 MEW 00 c 0. o N' a ---- 83 ��� MEW ;Y' U EXIST CONIC PVMT STM MH W/12"X4" CONIC CURBS = N.36"IE=12.57 S.36"IE=12.57 a s SANSWR MH S P R I N G W O O D DR. EA 8"IE=14.49 � (50' R.O.W.) CURB INLET THROAT=17.63 S.18"I E=14.74 W.18"I E=14.74 MATCH INLET 18" FL 14.74 ° 0 0 3.1 W 0 EXIST 12' MAINTENANCE ACCESS WOOD FENCE FND. 1 /2" I.R. 20' DRAINAGE ESMT. 47 HOUSE i 1 2 sEC 5 sT EXIST SWALE TO REMAIN pAvio F AID STM MH N.48"IE=12.34 S.48"I E=12.34 CURB INLET THROAT=17.88 N.48"IE=12.53 S.36"IE=12.69 LEGEND h 1p°0 X EXISTING SPOT ELEVATIONS MEC MATCH EXISTING CURB MEP MATCH EXISTING PAVEMENT _ MEW MATCH EXISTING WALK TC TOP OF CURB TP TOP OF PAVEMENT TW TOP OF WALK PROPOSED 4" CONCRETE SIDEWALK PROPOSED TYPE A INLET 4O SHEET FLOW ARROW WHEEL CHAIR RAMP NOTES: 1. PROJECT BENCHMARK TO BE ESTABLISHED BY THE CITY OF LAPORTE. CONTRACTOR TO COORDINATE WITH CITY PRIOR TO COMMENCEMENT OF CONSTRUCTION. 2. CONTRACTOR TO VERIFY ALL FLOWUNE ELEVATIONS 48 HOURS PRIOR TO COMMENCING ANY CONSTRUCTION. IF A DISCREPANCY IS DISCOVERED, THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY FOR INSTRUCTIONS. 3. SEE "PHASING PLAN FOR ENHANCED FEATURES" (SHEET 5) FOR LIMITS OF PHASE TWO AND PHASE THREE CONSTRUCTION. CITY OF LA PORTE 604 W. Fairmont Parkway Planing Dept./Engineering Div. La Porte, Texas 77571 281-471-5020 civillrech Engineering, Inc. 11821 Telge Road Cypress, Texas 77429 (281) 304-0200 Fax (281) 304-0210 POND TO PARK PROJECT PARKING LOT GRADING & DRAINAGE PLAN F NO: DRAWN: ]JAR 0029.10 CHECKED: APPROVED: LY 2004 SHEET: 20' 8OF17 r- O O N a Q _- 1 1/2" SCHAD STEEL PIPE GENERAL NOTES: rr— "714111111( NOTES: 1) 2" MINIMUM DEPTH ON ALL SAWCUTS 5'-0" 1. ALL EDGES SHALL BE ROUNDED WITH 3/8" RADIUS ) EXISTING OR FUTURE WELD ALL AROUND (TYP.) — WITH RADIUS TOOL ON ALL EXPOSED EDGES. AT STREET/RAMP CONNECTION. 2. CONTROL JOINTS SHALL BE SPACED AT 4'-0" INTERVALS. 3) UNDERCUT PAVEMENT AS SHOWN ON UNDERCUT EXIST CONC. 12 " 3. CONTROL JOINTS SHALL BE 3/8" DEEP AND TROWEL EDGE. DETAIL. PVMT 11 MAX. 4. 1/2" EXPANSION MATERIAL REQUIRED WHERE SIDEWALKS ABUT BUILDINGS, 4) MAXIMUM 1:12 SLOPE ON WHEEL CHAIR RAMP. CURBS, DRIVEWAYS, OR EXISTING SIDEWALKS. 5) MINIMUM 2" COMPACTED BANKSAND BASE. .' .' = 4" COMPACTED 5. EXPANSION JOINTS SHALL BE SPACED AT 16 FT. INTERVALS TYPICALLY. 6) 4 INCH, 5 SACK CEMENT PER CUBIC YARD CONCRETE, — �M ��CEMENT STABILIZED 3/4" SCH.5 SAND STEEL PIPE I I o 6. WHERE NEW SIDEWALK IS PLACED AGAINST EXISTING SIDEWALK, SAWCUT 3000 PSI REINFORCED. EXISTING SIDEWALK TO AN EVEN STRAIGHT LINE PRIOR TO INSTALLATION 7) RAMP SECTION TO BE SCORED AT 4" SPACINGS VARIES I I I I I I I I I I I I I I I I OF THE NEW SIDEWALK. 7. TOP OF SIDEWALK TO BE AT OR ABOVE T.O.C. 8) SEE SIDEWALK "GENERAL NOTES" ON THIS SHEET 771.5 SACK / CYD 9) COLOR RAMP IN ACCORDANCE WITH SPECIFICATION # 00531. CEMENT STABILIZED SAND COLOR TO BE SPECIFIED BY ENGINEER. SEE SIDEWALK "GENERAL NOTES" ON THIS SHEET AS SPECIFIED 24" (4'-0" TYP.) 1-1/2" SLOPE 2 % MAX 3/8" R Fp 1 1/2" SCHAD I (TYP.) TOWARD STREET WHEEL CHAIR RAMP DETAILS STEEL PIPE • 1/4"-1/2" vff EMBEDDED e (TYP.) RAILING ELEVATION NTS O SAND BEDDING ON 90%STD. DENSITY 1 1/2" SCHAD � 3000 P.S.I. CONCRETE COMPACTED SUBGRADE. I STEEL PIPE 1/4"-1/2" (TYP.) SECTION CONTROL JOINT RAILING CROSS—SECTION SAFETY RA I L I N G (SIDEWALK CONTROL JOINTS SHALL BE BRICK STYLE NTS GROOVED 3/8" DEEP ON 4' CENTERS) IMPRINTED CONCRETE v EXPANSION JOINT 4'-0" 4'-0" (SPACED @ 16' TYP.) 11'-01, DOWELS #4 BAR, 24" O.C. NOTES: OR #3 BAR, 18" O.C. (TYP.) 3/4" BITUMINOUS JOINT SEALER DOWELS 1. STEEL TO MEET ASTM STANDARD SPECIFICATIONS 51 NOTE 3 FOR CONCRETE REINFORCING BARS. UNITS TO BE SPACED ON 12" CENTERS } SEE ° ` ' ° 1 /4" R ° e °da a 2. EXPANSION JOINT TO BE PLACED AS SHOWN ON PLANS. JOINT SEAL 3. CENTER DOWEL HORIZONTALLY ON JOINT EXISTING 4'-0" \ TABLE 1 e a ♦e a NAIL a '° d 26 GAUGE 4. CENTER DOWEL VERTICALLY IN CONCRETE SIDEWALK A MAX. SLOPE A o A. d DOWELS 12 a°e° °d o °, �4d° °, e , PLASTIC TUBE BASE. EXTEND THICKENED CONCRETE AS (TYP.) (TYP.) d ° e .4 (TYP.) ° e ° d° a NEEDED TO MAINTAIN 3" MIN COVER REDWOOD EXPANSION JOINT (TYPICAL) q_p� PLAN (SEE EXPANSION JOINT DETAIL) 00 6 0 A. °d°'e °d,'e d ♦ [° -A ° BRICK STYLE MIN. N do °d°.e " eo°cue IMPRINTED CONCRETE e 3/4" BITUMINOUS JOINT SEALER 112" DIA. x 14" LG. SMOOTH O SEE TABLE { e d ��, DOWEL AT 121, C/C. PAINT AND GREASE THIS HALF 11 \\ ;tee, °qa ° d °a Lu 1" REDWOOD EXPANSION PRE —MANUFACTURED M 3_� I/4" R.(TYP.) I" RED OOD EXPANSION JOINT MATERIAL JOINT MATERIAL OR 3/4- OR JOINT PLATE e o • • • • � e. 3/4' PREMOLDED MATERIAL A EXISTING 6"CONC.CURB PREMOLDED MATERIAL SECTIONI�EXPANSION CAP ;rvP? #3 AT 18"24 E.W. (TYP.), DOWEL TYPE EXPANSION JOINT #a AT z4° E.W. OR #3LBAR4 18AO.C4(TYP.)VNO.3REINF.@15"SPACING, 1'-51'-5" PLAN - JOINT PLATE CONTINUOUS EACH WAY. TYP. TYP. T-O" MIN. � 8'-0" MAX-1 TABLE 1 CONTROL JOINT EXPANSION JOINT TYP. TYPE "C" RAMP 1/4" DIA. 1 4" 0 N C4 I DOWEL DIA + 1/16" CONCRETE DI DEWALI< TYPE C RAMP, WH EEL CHAI R RAMP DETAI LS & GEN ERAL NOTES ELEVATION -JOINT PLATE EXPANSION AND CONSTRUCTION )OI NT DETAILS 6" Q 1/2" SMOOTH MORTAR FINISH CONCRETE °' , EXCEPT WHEN POURED BY MACHINE SIDEWALK 5' MIN DRIVEWAY WIDTH (SEE NOTE 2) ` 114 ROW LINE 1/4" R. i •• ! : '` ° #4 BAR ® 24" O.C. - 10" LONG N CONCRETE r:. "::;� ;.. ':. CONC. AS PER PAVING NOTES 6' 1/2" PREFORMED OR 1" BOARD EXPANSION JOINTSIDEWALK B B a " *p • a, FINISHED GRADE " �p "PA�7EM NT PROPOSED REINFORCED 1.' '' s•. - CONCRETE DRIVEWAY R (SEE NOTE ) #3's ® 18" O.C. EACH WA V-6" 1/2" Joint Seal - ,.> ♦ As Specified 'o4 ;SUBGFADE PER NOTES FACE OF CURB .•, 2" •''~ /�y GEOTEXTILE CONCRETE PAVEMENT LANDSCAPE EDGING FLARED CURB CAN BE BLOCKOUT FOR DRIVEWAY USED FOR RESIDENTIAL Q a. THE LOCATION OF CONSTRUCTION JOINTS & ENTRANCE ONLY G SAW CUT AND EXPOSE STEEL ON UTTER LINE DEFORMED METAL STRIPS MAY BE VARIED, WITH THE APPROVAL OF THE DIRECTOR OF THE EXISTING CONCRETE STREET, DEPARTMENT OF PUBLIC WORKS, TO SUIT THE NOTES: MINIMUM SAW CUT = 2" DEEP PROPOSED CONSTRUCTION METHODS OF THE 1. MORTAR FINISH NOT REQUIRED WHEN CURB IS POURED CONTRACTOR. BY A MACHINE, BUT CURB WILL HAVE THE SAME PLAN VIEW OF DRIVEWAY IN NOTES: OUTSIDE DIMENSIONS. CONCRETE STREETS WITH CURBS 1. DRIVEWAYS SHALL BE 6". 2. WHEN CONCRETE CURB IS TO BE PLACED ON EXISTING CONCRETE BASE #4 DEFORMED BARS, 10" LONG, 24" 2. RADII AND WIDTHS PER PLANS. O.C. DOWELLED AND SET IN QUICK SETTING CEMENT. 3. SIDEWALK SLOPE GREATER THAN 1:50 3. REDWOOD EXPANSION JOINTS SHALL BE INSTALLED AT 4'-0" REQUIRES TOOLED GROOVES 2" O.C., ALL PAVEMENT EXPANSION JOINTS. SAW CUT AND EXPOSE STEEL ON °� EXISTING CONCRETE STREET, SIDEWALK 2' 3:MAXIMUM CROSS SLOPE 1:20, MEDIUM MINIMUM SAW CUT = 2" DEEP (SEE NOTE 3) 0 BROOM FINISH (NON-SK ID) AND 4. BACKFILL ALL CURBS TO MATCH TOP OF CURB (AFTER CONTRASTING COLOR. SETTLEMENT HAS OCCURED). V-6" 3/4" /FT TO 1 3/4"/FT 114" TO 1/2" /FT f� CONSTRUCTION )DINT SEAL DETAIL DEFORMED METAL STRIP CONCRETE PAVEMENT & CURB JOGGING TRACK SECTION d ° C PROPOSED 1" BOARD EXPANSION OR REINFORCED 1/2" NON EXTRUDING with Topeln Tot ur RETAINING WALL CONCRETE DRIVEWAY PREFORMED JOINT of Pave RE. SHT 16, DET 5 (SEE NOTE 1) 1s fs MI Dr, 1>01extile MIN REINFORCEMENT SHALL BE EXPANSION JOINT Concrete Paver #6x6x6 WWM OR GREATER 2318't60 AM) Min. Thickness Approx. 1 " to 1 1/2" TYPICAL (25-40 Mh1) Bedding Sand 12 MIN. REINFORCEMENT Compacted Aggregate Base (TYPICAL) 4" (100 MM) Min. Thickness SECTION A -A 'k 17-7 SEE STANDARD DETAIL TYPICAL DOWELS .. (SEE DETAIL) I DRIVEWAY WIDTH (SEE NOTE 2) d ♦ , id° ° d °d ° e7 111EXPANSION JOINT SIDEWALK_ ° ♦ ° ♦ ' ° ♦° SIDEWALK EXPANSION BOARD n °de ; de . d, ' o d°� ee °d%a do♦ , ° ° °d°e ° i / i a -A ° 2 - 4" BARS, 24" LONG g p°� Q p p O Compacted o� u Ya c 3" 7" d°'e °d MINIMUM (TYPICAL) CONCRETE PAVER SECTION # 4 BAR ®24 C-C 2'-0" TYP CONCRETE PAVEMENT 6" 6" 1" Sand Bedding Course 3" COMPACTED 6" STABILIZED PROPOSED a Car SAND BEDDING SUBGRADE REINFORCED ubbnsc Insitu Concrete Toe (TYP) CONCRETE DRIVEWAY Pave stone (SEE NOTE 1) COMPACT SUBGRADE TO 95% Existing Grade STANDARD PROCTOR DENSITY Subgrade #" Min SECTION B-B REINFORCEMENT AT INTERSECTING I P IF EXPANSION JOINTS 7 F - -- 1" Min• - . 4" Min. MN c-v:larr:='�iti`r�r° dra�.a�oi.za '''�'ii•.,; P�P — DRIVEWAYS FOR CONCRETE STREETS WITH CURBS 4-INCH x 12-1 NCH MONOLITHIC CURB STANDARD CONCRETE PAVING HEADER ADDITIONAL REINFORCEMENT _..- :ed.'d e.°..iT........... is :�.. e . e.':.:'...::':. _. .._ ... .iYJM;,11:Aw CONCRETE PAVER EDGE RESTRAINT PAVEMENT THICKNESS (IN) DOWEL SIZES AND SPACINGS DIAMETER (IN) LENGTH (IN) SPACING (IN) 6 3/4 24 12 7 1 24 12 8 1 24 12 9 1-1/4 24 12 10 1-1/4 24 12 11 1-1/4 24 12 12 1-1/4 24 12 REVISIONS NO. REVISION / ISSUE DATE CITY OF LA PORTE 604 W. Fairmont Parkway Planing Dept./Engineering Div. La Porte, Texas 77571 281-471-5020 civillrech Engineering, Inc. 11821 Telge Road Cypress, Texas 77429 (281) 304-0200 Fax (281) 304-0210 POND TO PARK PROJECT PAVING DETAILS PROJECT NO: DRAWN: GWM 220029.10 CHECKED: EKO APPROVED: JAR DATE: JULY 2004 SCALE: SHEET: 9 OF 17 REVISIONS NO. REVISION / ISSUE DATE 0 O N 1-7 Q C- Ct •� I � Cj 0 rn C c W 3 0 N �O O N 04 04 O O V� N SHAPE CEMENT - STABILIZED SAND TO CONFORM TO BOTTOM OF PIPE BACKFILLWITH IN -SITU MATERIAL COMPACTED TO 95% STD PROCTOR DENSITY 2' WIDE FILTER FABRIC CENTERED AT EACH JOINT, ALL AROUND 2" SEAL SLAB NO DIRECT PAYMENT FOR CEMENT STABILIZED SAND BEDDING NOTE: 1. REINFORCED CONCRETE PIPE STORM SEWERS, 36" DIAMETER AND SMALLER, MAY BE INSTALLED WITH COLD COMPOUND JOINTS OR GASKET JOINTS AS APPROVED BY ENGINEER. 2. CEMENT STABILIZED SAND PLACED BEFORE PIPE IS LAID. 3. 2 SACK PER TON CEMENT STABILIZED SAND, THOROUGHLY RODDED, PLACED AFTER PIPE IS LAID. 4. WHERE SOIL CONDITIONS REQUIRE, THE ENGINEER MAY ORDER USE OF WASHED SHELL, OR OTHER APPROVED GRANULAR MATERIAL IN LIEU OF CEMENT STABILIZED SAND BEDDING. NO DIRECT PAYMENT FOR WASHED SHELL. 5. WHERE WET SAND IS ENCOUNTERED, REFER TO WET SAND BEDDING DETAIL. 6. THIS BEDDING DETAIL SHALL BE USED FOR HDPE STORM SEWER AS WELL AS RCP STORM SEWERS. WALLS AND FLOOR WHEN ARE INLINE DRAINS USED? THE INLINE DRAIN CAN BE USED Tn FNTFR AN EXISTING LINE BY USE OF A RN r MORTAR FILLED DOWELS 2'-5 3/ " 4 X ❑ ❑ ❑ (-`0ATC 11/16 11 (TYP.) 11/ ., 3 44" (TYP.) H a 15/16 -1 I' I I �15/16 SECTION X-X MANHOLE COVER NOTE: VULCAN, EAST JORDAN IRON WORK OR APPROVED EQUAL THE INLINE DRAIN CAN BE USED AT NNING OF DRAIN LINE C7aAnnC: 2'-6" 3' 3/4" 2'-4 3/ , 4 ii SECTION Y-Y TYPE "A-1" INLET A DUCTILE IRON FRAME AND GRATE C B BEDDING DETAILS FOR 12" TO 36" DIA. & SMALLER TEE 24X4 VARIOUS TYPES OF OUTLETS DRAIN REINFORCED CONCRETE PIPE STORM SEWERS TYPICAL INSTALLATIONS 10" INLINE DRAIN 24X6 FORH WATERTIGHT ADAPTERS DRAIN BASIN INLINE 24X8 12" DRAIN BASIN 24X10 ADS N-12 TYPICAL INSTALLATION OF NYLOPLAST DRAIN BASIN AND 24X12 SCHED SEWER SCHEDULE 40 DWV INLINE DRAINLmmwrmm24X15 CORRUGATED PVC 24X18 RIBBED PVC Specifications CONCRETE : Class 1 concrete with design strength of 4000 PSI at 28 days. Unit is of monolithic construction and is designed conforming to ASTM C-76 Class III, Wall B. REINFORCEMENT: Grade 60 reinforced. Steel rebar conforming to ASTM A185 on required centers or equal. JOINT SEALANT : An asphalt based mastic shall be used at the tongue and groove ends to provide a watertight seal. TYPICAL GROOVE END, RE: DETAIL DULE END, RE: DETAIL GROOVE TONGUE TYPICAL END DETAIL DIMENSION SCHEDULE OF C-76 TONGUE & GROOVE PIPE PIPE SIZE I.D. O.D. WT. / FT. AVAILABLE LENGTHS REINFORCEMENT WALL THICKNESS WT TONGUE LENGTH TL GROOVE DEPTH GD SLOT DIM QUANTITY L.F. A B 12" 16" 100 LBS 4' OR 6' W 2.Ox2.5 3"x8" 2" 2" 2" 13i" 14w" 15" 19i" 125 LBS 4' OR 6' W 2.Ox2.5 3"x8" 2r" 2w" 2w" 16i" 17y" 18" 23" 160 LBS 4' OR 6' W 2.Ox2.5 3"x8" 2i" 2" 2r" 19p" 20i" 24" 30" 260 LBS 4' OR 6' W 2.Ox2.5 3"x8" 3" 2y" 2s" 263" 273" 30" 37r" 395 LBS 6' W 3.Ox2.0 2"x8" 3p" 3y" 3i" 31 s" 33y" 36" 44" 520 LBS 6' W 3.5x2.0 2"x8" 4" 2" 2r" 32s" 34y" 42" 52" 743 LBS 8' W 3.5x2.0 2"x8" 5" 4" 1 2r" 52" 52r" 48" 1 58" 838 LBS 8' W 3.5x2.0 2"x8" 5" 4i" 4s" 52" 52r" REI N FORCED CONCRETE PI PE 12" TH RU 36" i i VARIABLE ELEVATION WHEN ARE DRAIN BASINS USED? 1: CHANGE ELEVATION AVAILABLE IN SIZES 8" THROUGH 30". ADAPT TO PIPE SIZES 4" THROUGH 30". WATERTIGHT ADAPTERS AVAILABLE FOR ALL PLASTIC PIPING SYSTEMS 2: CHANGE DIAMETER CORRUGATED 15" 10" POLY PIPE GRATE 0 2 3.04 FRAME 0 28.50 STANDARD APPROX. DRAIN AREA= 194.60 SQ. IN. 47 APPROX. WEIGHT WITH FRAME = 124.00 LBS. NYLOPLAST 24" GRATES/COVERS STANDARD GRATE HAS H-25 HEAVY DUTY RATING SOLID COVER HAS H-25 HEAVY DUTY RATING PEDESTRIAN GRATE HAS H-10 MEDIUM DUTY RATING QUALITY: MATERIALS SHALL CONFORM TO ASTM A536 GRADE 70-50-05 MATERIAL: DUCTILE IRON PAINT: CASTINGS ARE FURNISHED WITH A BLACK PAINT LOCKI NG DEVICE AVAILABLE UPON REQUEST PRICE INCLUDES FRAME & GRATE/COVER .41 10" INLINE 3: CHANGE PIPE "'R 0 24.75 1 L FRAME 0 28.50 SOLID APPROX. WEIGHT WITH FRAME = 138.00 LBS..47 INLET ADAPTERS CAN BE PUT ON ANY ANGLE 4: CHANGE DIRECTION o AD SMOOTHWALL PVC GRATE 0 24.75 3.04 FRAME 0 28.50 *PEDESTRIAN APPROX. DRAIN AREA = 164.10 SQ. IN. 47 APPROX. WEIGHT WITH FRAME = 99.50 LBS. SIZE OFOPENING MEETS REQUIREMENTS OF AMERICAN DISABILITY ACT AS STATED IN FEDERAL REGISTER PART III, DEPARTMENT OF JUSTICE, 28 CFR PART 36. NONDISCRIMINATION ON THE BASIS OF DISABILITY BY PUBLIC ACCOMMODATIONS AND IN COMMERCIAL FACILITIES, FINAL RULE. AVAILABLE JANUARY 1, 2002 GENERAL NOTES: 1. USE STD CAST IRON FRAME & PLATES. LEAD SHALL LEAVE INLET AT LOCATION AND GRADE REQUIRED. 2. DIMENSION VARIES BASED ON PIPE DIAMETER AND WALL THICKNESS. 3. CENTER REINFORCING IN SLAB AND WALLS. 4. CENTER STEEL BEAM ON INLET AND CAST INTO WALLS AS SHOWN. 5. POURED -IN -PLACE OR PRE -CAST INLETS ONLY SHALL BE USED. 6. NO BRICKS OF ANY KIND WILL BE ALLOWED IN CONSTRUCTION OF MANHOLES OR INLETS. 7. ALL PVC PIPE SHALL HAVE RUBBER GASKET EQUIPPED BELL AND SPIGOT JOINTS CONFORMING TO ASTM D3212. ELASTOMERIC SEALS SHALL BE A SINGLE DOUBLE -SEALING GASKET SPANNING ONE FULL CORRUGATION WITH THE LEADING EDGE BEING LOWER THAN THE SECOND EDGE TO FACILITATE PROPER JOINING. THE GASKET MATERIAL SHALL CONFORM TO ASTM F477. 8. FOR ALL PRE -CAST AND POURED- IN -PLACE INLETS AND JUNCTION BOXES, CENTER DOUBLE- SEALING GASKET IN WALL AND GROUT COMPLETELY AROUND PVC PIPE. GROUT SHALL BE SMOOTH AND FLUSH WITH INNER AND OUTER WALL WHEN ENTERING AT AN ANGLE TO THE WALL OR THROUGH THE CORNER OF AN INLET OR JUNCTION BOX, THE GASKET MAY BE OMITTED. A DUCTILE IRON FRAME AND GRATE C B VARIOUS TYPES OF OUTLETS 24X24 WITH WATERTIGHT ADAPTERS FOR: ADS N-12 SDR-36 SEWER SCHEDULE 40 DWV CORRUGATED PVC RIBBED PVC A B C 24" 4" 15.00 24" 6" 15.00 24" 8" 15.00 24" 10.1 15.00 24" 12" 16.00 24" 15" 16.00 24" 13.. 10.00 24" 24" 10.25 PROP. FRAME AND SOLID COVER (NEENAH CAT. NO. R-4990HX WITH TYPE "D" COVER) END FRAME SECTIONS TO BE UTILIZED ON BOTH ENDS' CONCRETE SIDEWALK TO .. 4" C.L. DITCH DEPTH VARIES CONCRETE SIDEWALK .......' '.'.'.'........ SIDEWALK DRAIN CITY OF LA PO RTE 604 W. Fairmont Parkway Planing Dept./Engineering Div. La Porte, Texas 77571 281-471-5020 civill ech Engineering, Inc. 11821 Telge Road Cypress, Texas 77429 (281) 304-0200 Fax (281) 304-0210 POND TO PARK PROJECT STORM SEWER DETAIL PROJECT NO: DRAWN: GWM 220029.10 CHECKED: EKO APPROVED: JAR DATE: JULY 20( SCALE: SHEET: 10 OF 17 REVISIONS NO. REVISION / ISSUE DATE n 0 0 N d Q �� rn _C W 3 0 N 4)o o N :04 / s— o 0.0 I— % �IL GENERAL NOTES: 1. PROVIDE STEEL TAPPING SLEEVE. 2. WELD SHALL BE AS NOTED IN WELD SYMBOLS. 3. INSULATING KIT STAN DARD TAP TO STEEL MAIN HALF SECTION --w UNDER PAVEMENT 1_via1TAia.r1 SUBGRADE EMBEDMENT MATERIAL PER CITY OF LA PORTE STANDARD SPECIFICATIONS DRY BOTTOM SYMMETRICAL ABOUT HALF SECTION UNDER NATURAL GROUND SOD OR SEE (AS REQUIRED) PER CITY OF LA PORTE STANDARD SPECIFICATIONS BACK ILL PER / �/ �/ BRTE ACK SP CIFTY OF LA OICATI\NS'�/� SEE NOTE SEE. • ' . SEE' . NOTE NOTE O• SEE NOTE 2 ;'.i. .,•• ;,i. NATURAL GROUND SPRING LINE NOTE: 1. SEE CITY OF LA PORTE STANDARD DETAIL 2. 6" MIN. FOR MAIN DIAMETER <20" 12" MIN. FOR MAIN DIAMETER 720" WATER DISTRIBUTION MAIN BEDDING & BACKFI LL FOR OPEN CUT TRENCHES NATURAL GROUND A/C, CAST IRON, DUCTILE IRON, PVC WATER LINE I NSULATED JOINT (BOTH ENDS) SLIP ON FLANGE (ASA B 16.1) BELL/FLANGE CONNECTION (TYPICAL TRANSITION) (BOTH ENDS) FOR LINE TO PASS OVER AN OBSTRUCTION RATHER THAN UNDER MUST HAVE ADEQUATE COVER AND BE APPROVED BY CITY ENGINEER L OBSTRUCTION 9 �lFs �rT 5' MIN SFT ///PSTEELIPE (TYP) Ii� 2' MIN 4 - 45° STEEL BENDS NOTE: 1. MATERIALS AND COATINGS TO BE IN ACCORDANCE WITH WATER MAIN STANDARD SPECIFICATIONS. 2. RESTRAIN EXISTING PIPING BEYOND STEEL SECTION AS REQUIRED TO PREVENT MOVEMENT. WELDED JOINTS (TYP.) TYPICAL STEEL SECTION FITTINGS 4 - 0 X 45' STEEL BENDS 2 - 0 BELL -FLANGE ADAPTERS 2 - 0 SUP -ON FLANGES 150 # 2 - 0 INSULATED JOINT KITS TYPICAL STEEL PIPE OFFSET SECTION FOR WATER MAINS GATE VALVE - WITH BOX TO BE OPEN LEFT 7- FINISHED GRADE EXTRA THICK AND WIDE MEDPRENE RUBBER GASKET 4MIN. MAIN MAIN SIZE SIZE 16" 12" 45° (TYP.) 14" 10" 12" 8" 10" 6" 8" 1 4" NEW -WATER MAIN (MUELLER BRONZE SERIES 13400, ROCKWELL 315 (EPDXY COATED), FORD 101 (EPDXY COATED)OR APPROVED EQUAL TOP VIEW TAPPING SLEEVE TO BE EPDXY COATED OR CAST IRON (NO OTHER ACCEPTED) TAPPING SLEEVE & VALVE DETAIL CONCRETE THRUST BLOCKING v a, NOTE: USE MECHANICAL JOINT FITTINGS 11141 CITY OF LA PORTE 604 W. Fairmont Parkway Planing Dept./Engineering Div. La Porte, Texas 77571 281-471-5020 ChAll-ech Engineering, Inc. 11821 Telge Road Cypress, Texas 77429 (281) 304-0200 Fax (281) 304-0210 POND TO PARK PROJECT WATER DETAILS PROJECT NO: DRAWN: GWM 220029.10 CHECKED: APPROVED: EKO JAR DATE: JULY 2004 SCALE: SHEET: 11 OF 17 I a Q V � y^ CL 1III CL N N rn C W 3 0 �% N 0 O N 04 s .04 O O V CL LEGEND S—,STABILIZED CONSTRUCTION EXIT IPA INLET PROTECTION BARRIER x— RFB —x REINFORCED FILTER FABRIC BARRIER N MESQUITE (50' R.O.W.) I I FAIRMoNT I31 30 35 34 33 32 29 28 27 26 25 24 23 �P 5P I 1� I EXIST 8' UTIL. ESMT. tt L WOOD FENCE WOODFEN E C WOOD FENCE WOOD FENCE WOOD FENCE STM MH N.RIM=8.83 v - TO ANK N.48"IE111.43 E.60"IE=11.43 ANK- TOE TOE W.60"IE=11.43 60" RO "RC 60" RCP 36" RCP TC E � � � _ _ STM MH N.RIM=18.74 e S.48"IE=11.54 E.36"IE=11.54 W36"IE=11.54 Y Z m o P O o m 0 a �P O a I I� w z ¢ > m O`J O I z �m U a a I < 8" WATERLINE- - - 8" RCP IPB — I L Q Y Z Q W Z O F m O O 3� 1.I W F O6 Q W 0 1)0 TOE TOE Q TOE TOE TOP BANK " ^ .: TOP BAt l -TOP_@RNK ---SOP-BANK- TOP BANK XI T 14' UTI S EXIST 12' MAINTENANCE ACCESS ' 50G WOOD FENCE WOOD FENCE WOOD FENCE WOOD FENCE I sc I U r �I 47 3 vE " HOUS ESE R 1 2 3 4 5 6 7 8 9 10 11 11"TALLOW IPB s SEC- SST A \ la EAIRMONT \ \ \ 0 18 19.11 W IPB IPA DR. \ (50' R.O.W.) (50' \ II REVISIONS NO. REVISION / ISSUE DATE CITY OF LA PORTE 604 W. Fairmont Parkway Planing Dept./Engineering Div. La Porte, Texas 77571 281-471-5020 civillech Engineering, Inc. 11821 Telge Road Cypress, Texas 77429 (281) 304-0200 Fax (281) 304-0210 POND TO PARK PROJECT STORM WATER POLLUTION PREVENTION PLAN PROJECT NO: DRAWN: GWM 220029.10 CHECKED: EKO DATE: APPROVED: JAR JULY 2004 SCALE: SHEET: 1 "=40' 12 OF 17 REVISIONS NO. REVISION / ISSUE DATE _St •� T =i .� rn C W 30 =i N �o o N �i No 0 V� 1. SET POSTS AT REQUIRED SPACING 3. ATTACH FILTER FABRIC TO POSTS AND EXTEND IT INTO THE TRENCH (SEE NOTE 3) 18" MIN. 36" MAX. , FLOW X— RFB — X GENERAL NOTES: EXTENSION INTO TREN 1. POSTS TO BE SET AT 6 FOOT MAXIMUM SPACING. 2. WOVEN WIRE FENCE TO BE FASTENED SECURELY TO POSTS WITH WIRE TIES OR STAPLES ADDITIONAL TIES OR STAPLES CAN BE ADDED TO SECURE WOVEN WIRE FENCE. 3. FILTER FABRIC TO BE FASTENED SECURELY TO WOVEN WIRE FENCE WITH WIRE TIES OR STAPLES AT TOP AND MIDSECTION. ADDITIONAL TIES OR STAPLES CAN BE ADDED TO SECURE FABRIC. 4. WHEN TWO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER THEY SHOULD BE OVERLAPPED 6" INCHES AT THE POSTS AND FOLDED. 5. CUT "D" SHAPED HOLES %Z OF HEIGHT AWAY FROM NATURAL GROUND AND SPACED NO MORE THAN 4 FEET ON -CENTER. REIN FORCED FILTER FABRIC BARRIER 2. EXCAVATE A 6"x6" TRENCH UPSLOPE ALONG THE LINE OF POSTS AND SECURE WIRE FENCE TO POSTS. (SEE NOTE 2) FLOW FLOW 4. BACKFILL AND COMPACT THE EXCAVATED SOIL. �.�rrrw.�r��irar �r�■ C 12" MIN. O O o 0 o 0 1 0 o 1 O O 0 O ° INLET C 0 ° 0 0 0 0 0 O 0 0 0 O 0 ° 0 O O O O O O O O O O STRAW BALES STAKED WITH 2 STAKES PER BALE PLAN BALE 4-24 INCHES FROM INLET COMPACTED SOIL TO PREVENT PIPING 12" 4" FLOW SYMBOL STRAW BALE DROP INLET PROTECTION BARRI ER 14' IGHT-OF-WAY 50' MIN. RIGHT-OF-WAY SEPARATION GEOTEXTILE —/ GRADED TO PREVENT FABRIC FOR FULL WIDTH RUN-OFF FROM LEAVING SITE AND LENGTH OF EXIT .. e13ir GENERAL NOTES: 1. LENGTH SHALL BE AS SHOWN ON THE CONSTRUCTION DRAWINGS, BUT NOT LESS THAN 50 FEET. 2. THICKNESS SHALL BE NOT LESS THAN 8 INCHES. 3. WIDTH SHALL BE 14 FEET MIN. FOR ONE WAY TRAFFIC AND 20 FEET MIN. FOR TWO WAY TRAFFIC. 4. STABILIZATION FOR OTHER AREAS, SUCH AS EQUIPEMTN STORAGE AREAS, SHALL HAVE THE SAME AGGREGATE THICKNESS REQUIREMENTS AS THE STABILIZED CONSTRUCTION ACCESS. 5. STABILIZED AREA MAY BE WIDENED OR LEGTHENED TO ACCOMODATE A TRUCK WASHING AREA, WHEN SHOWN ON THE CONSTRUCTION DRAWING. AN OUTLET SEDIMENT TRAP UST BE PROVIDED FOR THE TRUCK WASHING AREA. 6. THE APPROACH TRANSITIONS SHALL BE NO STEEPER THAN 6: 1. STABILIZED CONSTRUCTION ACCESS TYPE 1-ROCK 2 INCH BY 2 INCH WOOD STAKE EMBEDED 8 INCHES 6011F0 21I ma9:4_\TiTZ:1_ja2 4„ 00� INLET SECTION �`J WOOD OR METAL ST""r (MIN 2 INCH BY 2 WOOD POST) D PLAN FILTER FABRIC EXTENSION OF FABRIC INTO TRENCH FLOW SYMBOL FILTER FABRIC 24 INCHES CONSTRUCTION NOTE: 1. SEE CONSTRUCTION NOTES FOR RFB. WIRE SECTION OD POST SILT FENCE INLET PROTECTION BARRIER CITY OF LA PORTE 604 W. Fairmont Parkway Planing Dept./Engineering Div. La Porte, Texas 77571 281-471-5020 civillech Engineering, Inc. 11821 Telge Road Cypress, Texas 77429 (281) 304-0200 Fax (281) 304-0210 POND TO PARK PROJECT STORM WATER POLLUTION PREVENTION DETAILS GWM ECKED: EKO PROVED: JAR EDAWN: SHEET: 0 13 OF 17 REVISIONS NO. REVISION / ISSUE DATE r 0 O N a Q 3 J w 0 PIPE I.D. PIPE WALL "B" THICKNESS O „D„ SLOPE MINIMUM LENGTH OF UNIT SINGLE PIPE MULTIPLE PIPE SKEW PIPE RUNNERS REQUIRED SKEW PIPE RUNNERS REQUIRED 12" 2" 17" 3:1 2'-11" <=45 deg No <=45 deg No 4:1 3'-6" 6.1 4'-9" 15" 2 1/4 " 20 1/2 " 3:1 3'-8" <=45 deg No <=45 deg No 4:1 41-711 6:1 6-5" 18" 2 1/2 " 24" 3.1 4'-6" <=45 deg No <=45 deg No 4:1 51-811 6.1 81-0" 24" 3" 31" 3:1 6'-2" <=45 deg No <=30 deg No 4:1 7'-10" > 30 deg Yes 6:1 11'-3" 30" 3 1/2 " 38 1/2 " 3.1 7'-10" <=15 deg No <=15 deg No 4:1 10'-1 " > 15 deg Yes > 15 deg Yes 6.1 14'-8" 36" 4" 45 1/2 " 3.1 9'-5" =0 deg No =>0 deg Yes 4:1 12'-3" >0 deg Yes 6:1 17'-11" 42" 4 1/2 " 52 1/2 " 3:1 =>0 deg Yes =>0 deg Yes 4:1 14'-5" 6:1 21'-2" CL' Safety Pipe Runner Pipe Support Cradle Welded to Support Post 3/4 " Threaded Insert q Pipe Support Post (Post to be same diameter as Safety Pipe runner and fitted in a formed pocket) C L 3/4 " Galvanized Steel Bolt & Nut with Washer Flowline �_ 3/4 " Galvanized Steel Bolts with Washers and Inserts END DETAIL FOR INSTALLATION OF SAFETY PIPE RUNNERS 6" Min O O °. (If required) Reinf to have 1" Min cover Cement Stabilized Bedding and Backfill O MULTIPLE PIPE INSTALLATION OPTION WITH SQUARE BOTTOM SECTION A -A Unit Length Varies 7" Max Safety Pipe Runner Length O End of payment for Pipe C L Safety Pipe Runners (If required) �n Ow E w a- o p p a- - c a - See Detail "A" / Cn Pocket is to be Formed to fit O.D. of Pipe Support Post if Safety Pipe Runners are used. ZIWM, 0 A Optional Safety Pipe Runner Step Slope o (If required) i� Top Face of Safety End Treatment Slope O Optional casting - line for Toewall C9 0 O � Flowline 0 O 1�511 A 1 6„ co LONGITUDINAL ELEVATION Pipe stub shall Safe y have an O.D. of Pipe 1/4 " to 5/8 " less Run er than the I.D. of the Safety Pipe Runner \A 12" 1/4 OPTION A DETAIL A (If required) 5" Min ' •s Liz ° . ° • . OPTION WITH INVERT BOTTOM Invert 1/4 V Cross Pipe to be same size as Safety Pipe Runner or 1/2 " larger OPTION B Pipe pia Cross Pipe Safety Pipe Runner Maximum Safety Pipe Runner Length Required Pipe Runner Size Pipe Size Pipe O.D. Pipe I.D. 111- 2" 3" STD 3.500" 3.068" 15'- 6" 3 1/2 " STD 4.000" 3.548" 20'-10" 4" STD 4.500" 4.026" 351- 4" 5" STD 5.563" 5.047" ODimension "D" is based on ASTM C-76, Class III, Wall thickness "B". If any other wall thickness is used, dimension "D" must be adjusted accordingly. OSlope as shown elsewhere in plans. Slope of 3:1 or flatter is required for vehicle safety. OToewall to be used only when dimension is shown elsewhere in the plans. OThe top 4" of void between precast end treatments shall be filled with concrete riprap and shall be considered subsidiary to Safety End Treatment. OClear distance between pipes shall be adjusted to provide for the minimum distance between safety end treatments. 6O Measured along Slope. OCement stabilized bedding and backfill shall be in accordance with the Item, "Excavation and Backfill for Structures". Bedding and backfill shall be considered subsidiary to the Item "Safety End Treatment". When concrete riprap is specified around the safety end treatment, backfill shall be as directed by Engineer. GENERAL NOTES: Precast safety end treatment for reinforced concrete pipe may be used for TYPE II end treatment as specified in Item "Safety End Treatment". When Precast Safety End Treatment is used as a Contractor's alternate to mitered RCP, Riprap will not be required unless noted otherwise on the plans. Manufacture of this product shall conform to requirements of Item "Safety End Treatment" except as noted below : A. Minimum reinforcing shall be #4 at 6" (Grade 40) or#4at9"(Grade 60)each way or6x6-W12xW12 or 5 x 5 - W10 x W10 welded wire fabric. B. Concrete for precast (steel formed) sections shall be Class "C" with a minimum compressive strength of 3600 psi. At the option and expense of the Contractor the next larger size of Safety End Treatment may be furnished; as long as the "D" dimension cast is that of the required size of pipe. Pipe Runners are designed for a traversing load of 1,800 Lbs at yield as recommended by Research Report 280-1, "Safety Treatment of Roadside Cross -Drainage Structures", Texas Transportation Institute, March 1981. Safety Pipe Runners, Cross Pipes, Pipe Support Posts, and Pipe Stubs shall conform to the requirements of ASTM A53 (Type E or S, Grade B), ASTM A500 (Grade B), or API 5LX52. All steel components except reinforcing, shall be galvanized after fabrication. Galvanizing damaged during transport or construction shall be repaired in accordance with the specifications. 3/4 " Galvanized Steel Bolts with Washers and Inserts D _ D 1/3 Pipe Dia Q • Q Prniontinn ` D D D - -- -_--- 3/4 " Threaded Insert INSTALLATION DETAIL FOR SAFETY PIPE RUNNERS (If required) 6" CO Precast end section may be produced with spigot or bell end as required OPTIONAL JOINT (Showing joint between RCP and Precast Safety End Treatment) CITY OF LA PORTE 604 W. Fairmont Parkway Planing Dept./Engineering Div. La Porte, Texas 77571 281-471-5020 chillrech Engineering, Inc. 11821 Telge Road Cypress, Texas 77429 (281) 304-0200 Fax (281) 304-0210 POND TO PARK PROJECT PRECAST SAFETY END TREATMENT PROJECT NO: 220029.10 DRAWN: GWM CHECKED: EKO APPROVED: JAR DATE: JULY 2004 SCALE: SHEET: 14 OF 17 - i5 IF3: m 16 15 - - - - - - - - - - - - - 4 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - --- - - --- - - --- r- (-- TqR OF WALL , - _(-ew­-NeT- sHe - - - - - - - - - - - T - - - I - - - t - - - - - - - - - - - - - - - - - - - - - - - - - - - I - - GRADE.- BEHIND - - t - - - - - - t - - - - - - - - - - - - r - - - - - - - - - - - I ____t - - I - - - - - t - - - - - - - - - r - - - - I - - - I - - - - - - - - - I 1 - - - - t - - - - - - t - - - - - - - - - T - - - - - - - - - - - 1 - - - - - - - - - - - - - - - - - - i 14 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - --- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13 - - - - - _1870 :�MRA T` JT - - - = - - - - - - - - --- vlR�rD =L8-.cr FT- 1 1 1 - - - - - - T - - - - - - - - - - 7 - - - - - T - - - - - - 177— 4kGRrD-.5XT- = 18.70 TT- 12 - - - - - -- I_ -------I----------- --- -- - - - - - - - I - - - - - - - 4 - - - - - -- I_ ----------------------------I-------------- I_ - - - - - - - I - - - - - - - 4 - - - - - -- I_ - - - - - - - - - - - - - - 0 4 Rnr3XT = -�IBXI-FT - T­ 1, F - - - - - - - - --- - - --- AGRrD -3 -4 - - - jyjR SIFT - + - - - 4 - - - - - - - - - - - - - 4 - - - - - - 4 - - - - - - - -4 - - - - - - 4 - ------I---- - MffZAGRrD-3XT- = 118.0 -ET--- - =+ --I - - - - - - -- 10 09 - -- t_ - - - - - - - - - - - - - ------1------ - - - - - - - - I - - - - - - - - --- - - - - t - - - - - - - I - - - - - - - t - - - -MKGRIU _3XT_4:_ - _T - - - - - - t - - - - - - - - - - - - - - - - - - - - - - - - - - - - - t - - - - - - - - - - - t - - - - - - - - - - -I-- - - - - - - - - t - - - - - - - - - - - t - - - - - - - - - - - - - - - -I-- - - - - - - - - - - - t - - - - - - t - - - - - - - - -I-- - - -1 - - - - - - - - - - 8-.(T FT_ r T t I 9MGRlD_MT_ Z'18.'U TT_ < 08 - - - - - - - L -i - - - - - - - - - - --- 7- -7 - - - - - - - - - - - - - - - - -7 - - - - - - - - - - - - - - -7 - - - - -7 - - - - - - - 7- - - - - - -7 - - - - -7 - - - - - - - - 7- - - - - - - - -7 -7 - - - - - - - - - - - - 7- > 07 - -- - - - - - - - - - - - - - - - - - - - - I A I - - - - - - --- WKGRID _jX QF F�T - - - - - - I - - - - - - - - - - 1-_- - - L I - - 10 kQRlD _3XT - @..0 T - - - - - - - - - - - Ld 06 _T_ __L _L __L _Q _L _j 05 1 - - - - - - 4 - - - - - - 04 - - - - - - - I- - - - - - - t - - - - - - t - - - - - - I - - - - - - - - - - - - - t - - - - - - - I - - - - - - - t - - - - - - - - - - - - - - - - - - t - - - - - - t - - - - - - - I _t - - - - - - t - - - - - - - I - - - - - - - t - - - - - - t - - - - - - - - - - - - - - 03 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - --- - - - - - - - - - - - - - - - - - - - - - - - - - - - t - - - - - - - _§Aff W_ Wk - - - - I - - - - - - - T - - - - - - r - - - - - - - - - - - - - -- 02 - - - - - - - - - - I-- - - - - - - - - - - - - ___ - - - - - - - - - - - - PROP- FINISH GRADE I I - - - - I _�T� P- GF-FOGRI#� - _____I______ I I I Ol ------------- ----- ------------ ------------ &T-TOL DF-WALL- - - - - - - ----------------------------------------------- I 00 L (SLOPES-tQISHOW� A - - - I - - - - - - --- - - - - -- - - - - - - - - - - - - - - - - - - - -- -- - - - - - - - - - - - - - - - -- I_ - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - I - - - - - - 4 - - - - - - 4 - - - - - - - I - - - - - - --- - - - - - 4 - - - - - - - I - - - - - - 4 - - - - - - 4 - - - - - - - - - - - - 4 - - - - - - - I - - - - - - 4 - - - - - - 4 - - - - - - - I - - - - - - 4 - - - - - - 4 - - - - - - - - - - - - - 0 m 0 to 0 to 0 m 0 m 0 ui 0 m 0 m 0 m 0 m 0 0 0 N N 0) 0) to LO co CD CO CO 0) 0) (n U) (n (n (n (n (n (n (n (n (n PROFILE — WALL DETENTION POND 0 Ob 00 C; 0 C; 0 W) zip z wi Cn m Cn m RADE BEHIND TOP-OF-WALL GRADE WA -A - 16 ------ ------4------ eAP--NOT-SH0WN----------I------t - - - - - - - - - - - - - - - - - - - -- - - - - - 16 15 --------I------- ------ ------------ ------I -----t --- ------ ------ ------ ------ - 15 14 14 13 8 - - - - - -- ------ ------- - ------------------------ MtRAGRID­3X� I = -8.-0 -FT- -1 - ------------------- - - - - - - - - - - ----I I — — - — ------ ---------- I XT 7= - ImRnm_13 ------------- -a.-O 41 - - - - - - I----- 13 - I I- I I I- 1 12 - ------I-------------- I_ -------I--------------- I_ -------I------- I.------- --I------- I.------- I_ -------I - T 12 ------------4 MfRAGRID3XpIT --4------I------4------- -I-- 4=11 NnRAGRrD3xT 0 10 4------ 4------ 0 09 w -- I ------------I--- - - - - - - I - - - - - - - TMlRAURU_3X'r = -8.-0 _FT_ -1 - -----I-------- - - - - - --- - - - - - t - - - - - - - I - - - - - - - T - - - ---I-----_-- - - - t- - -4--=— - _'_ - -I - - - - - - - - - - --- ------10 -- ---1------ - 09 < 08 z = — — -T — - - - - - - - - - - — — I— — — -T- — — -T - - - - - - - - - - - - - - - - - - — — — — — — - T- — — - - - - - - - - - - - - - - - - - -T - - -T- -T --- - - - - - - 08 < > 07 1 1 1 _j MIRAUR1D_3X=- I.D I T - - - - - - - - - - - - T 1- - - - ---L_— - - - - - - --- - - - - - -- - - - - - -07 06 > UJ- J06 05 - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - ----- - - - -- - ------1------ - - -- - - - - - - - - - - - 05 W LIJ 04 - I t t t t I t f 1 04 03 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - _tPROP - - - - - - - - - WE -y I - WALL - - - - - - - - - - - - - - - - - - - - - - - - - - 03 02 ICI FIN[SH[ ]GRADE- FOO* - - - - ) 02 01 - - - - - - ------1------ -- - - - - - - - - - - -- -ADS - - - - - - - - AT TOE QF-WALL - - - - - - - - - - - - L- - I - - - -(-PP- - - - - - -OF- - - - - - - - - - - - - - - - - - - - - - - - - - - - - Ol 00 1 1 1 1 (SLOPES NOTI SHOWN) I I I I I I - - - - - - - - - - 1__OO - - - - - - --- - - - - -- I_ - - - - - - - I - - - - - - - I. - - - - - -- I_ - - - - - - - I - - - - - - - I. - - - - - - - - - - - - -- [ ------I--------------- I. -------I------- — — — — — -- I. -------I------- — — — — — -- I. -------I------- 4- - 0 to 0 0 p ul) 0 C14 to 0 C14 V) to K) 0 to 0 to 0 to 0 PROFILE — WALL DETENTION POND LEGEND INDICATES REINFORCEMENT LENGTH AND/OR ELEVATION CHANGE - — - GEOSYNTHETIC REINFORCEMENT SCALE 1" = 5' VERTICALLY SCALE 1" = 5' HORIZONTALLY CAPS NOT SHOWN FOR CLARITY 16 15 14 13 12 11 10 09 08 07 06 05 04 -03 -02 01 00 REVISIONS N DATE NO. REVISION / ISSUE j CITY OF LA PORTE 604 W. Fairmont Parkway Planing Dept./Engineering Div. La Porte, Texas 77571 281-471-5020 CivilTech Engineering, Inc. 11821 Telge Road Cypress, Texas 77429 (281) 304-0200 Fax (281) 304-0210 INTERIM SUBMITTAL DOCUMENT INCOMPLETE; NOT INTENDED FOR PERMITS, BIDDING OR CONSTRUCTION. ENGINEER: MARCUS J. MICHNA P.E. REGISTRATION NO. 84739 DATE: 07/02/04 POND TO PARK PROJECT RETAINING WALL LAYOUT FPROJECT NO: DRAWN: GWM 220029.10 CHECKED: EKO DATE: APPROVED: JAR JULY 2004 SCALE: SHEET: 15 OF 171 REVISIONS N0. REVISION / ISSUE DATE Q� C� a 'OA a C rn •� 3 as � =i •'OQ rn Wo =i N �O O N 04 04 O O i VCL GENERAL NOTES 1. CCONTRACTOR SHALL EXCAVATE TO THE LINES AND GRADES SHOWN ON THE 12 1/2" PROJECT GRADING PLANS. CONTRACTOR SHALL TAKE PRECAUTIONS TO MINIMIZE OVER -EXCAVATION. OVER EXCAVATION SHALL BE FILLED WITH COMPACTED INFILL MATERIAL, OR AS DIRECTED BY THE SITE SOIL ENGINEER. 2. SITE SOIL ENGINEER WILL OBSERVE THE EXCAVATION AND APPROVE PRIOR TO PLACEMENT OF BEARING PAD MATERIAL. 12" 3. OVER -EXCAVATED AREAS IN FRONT OF WALL FACE SHALL BE FILLED WITH COMPACTED INFILL MATERIAL AS DIRECTED BY THE SITE SOIL ENGINEER. 4. CONTRACTOR SHALL VERIFY LOCATION OF EXISTING STRUCTURES AND UTILITIES PRIOR TO EXCAVATION. 18" 5. CONTRACTOR SHALL ENSURE ALL SURROUNDING STRUCTURES ARE PROTECTED FROM EFFECTS OF WALL EXCAVATION. TOP VIEW 6. NON -REINFORCED CONCRETE LEVELING PAD SHALL BE PLACED AS SHOWN ON THE CONSTRUCTION DRAWINGS WITH A MINIMUM THICKNESS OF 12 INCHES. 7. SOIL LEVELING PAD MATERIAL SHALL BE COMPACTED TO PROVIDE A LEVEL, HARD SURFACE ON WHICH TO PLACE THE FIRST COURSE OF UNITS. COMPACTION WILL BE 8 1/2" 8- WITH MECHANICAL PLATE COMPACTORS TO DENSITIES SPECIFIED BY THE SITE SOIL L ENGINEER. 8. LEVELING PAD SHALL BE PREPARED TO INSURE INTIMATE CONTACT OF RETAINING WALL UNIT WITH PAD. FRONT VIEW 9. FIRST COURSE OF SRW UNITS SHALL BE PLACED ON THE BEARING PAD. THE UNITS SHALL BE CHECKED FOR LEVEL AND ALIGNMENT. THE FIRST COURSE IS THE MOST IMPORTANT TO INSURE ACCURATE AND ACCEPTABLE RESULTS. 10. INSURE THAT UNITS ARE IN FULL CONTACT WITH BASE. 11. UNITS ARE PLACED SIDE BY SIDE FOR FULL LENGTH OF STRAIGHT WALL ALIGNMENT. ALIGNMENT MAY BE DONE BY MEANS OF A STRING LINE OR OFFSET FROM BASE LINE TO THE REAR OF THE SRW UNIT. ADJUST UNIT SPACING FOR CURVED SECTIONS ACCORDING TO MANUFACTURER'S RECOMMENDATION. 12. PLACE UNIT FILL. 13. PLACE AND COMPACT FILL BEHIND AND WITHIN UNITS TO DENSITIES SPECIFIED BY THE SITE SOIL ENGINEER. 14. CLEAN ALL EXCESS DEBRIS FROM TOP OF UNITS AND INSTALL NEXT COURSE. ENSURE EACH COURSE IS COMPLETELY FILLED PRIOR TO PROCEEDING TO NEXT COURSE. 15. THE GEOSYNTHETIC REINFORCEMENT SHALL BE INSTALLED AT THE WALL HEIGHT, HORIZONTAL LOCATION, AND TO THE EXTENT AS SHOWN ON THE PROJECT CONSTRUCTION PLANS, OR AS DIRECTED BY THE ENGINEER. 16. THE GEOSYNTHETIC REINFORCEMENT SHALL BE LAID HORIZONTALLY ON COMPACTED INFILL AND CONNECTED TO THE CONCRETE SRW UNITS. 17. CORRECT ORIENTATION (ROLL DIRECTION) OF THE GEOSYNTHETIC REINFORCEMENT SHALL BE VERIFIED BY THE CONTRACTOR. 18. THE GEOSYNTHETIC REINFORCEMENT SHALL BE PULLED TAUT AND FREE OF WRINKLES PRIOR TO PLACEMENT OF SOIL FILL. THE GEOSYNTHETIC MAY BE SECURED IN PLACE WITH STAPLES, PINS, SANDBAGS OR FILL AS REQUIRED BY FILL PROPERTIES, FILL PLACEMENT PROCEDURES, OR WEATHER CONDITIONS, OR AS DIRECTED BY THE ENGINEER. 19. THE PROCEDURE FOR TENSIONING GEOSYNTHETIC REINFORCEMENT SHALL BE UNIFORM THROUGHOUT WALL LENGTH AND HEIGHT. 20. LAY EACH SUCCESSIVE COURSE OF SRW UNITS ENSURING THAT SHEAR CONNECTORS ARE ENGAGED. 21. REPEAT PROCEDURES TO THE EXTENT OF THE WALL HEIGHT. 22. UPPERMOST ROW OF SRW UNITS OR CAPS SHALL BE GLUED TO UNDERLYING UNITS WITH AN ADHESIVE, AS RECOMMENDED BY THE MANUFACTURER. 23. SURFACE DRAINAGE DURING AND AFTER CONSTRUCTION OF THE WALL SHALL BE PROVIDED TO MINIMIZE WATER INFILTRATION IN THE REINFORCED SOIL ZONE. MATERIALS A. HIGH STRENGTH, HIGH DENSITY CONCRETE UNITS, FREEZE -THAW RESISTANT WITH REAR ALIGNMENT FLANGE PROVIDING A 1 1 /8" SET BACK FROM PLANE WITH EACH COURSE, "ANCHOR DIAMOND RETAINING WALL UNITS" AS MANUFACTURED UNDER THE LICENSE OF ANCHOR WALL SYSTEMS. 1. CONCRETE WALL UNITS SHALL MEET REQUIREMENTS OF ASTM C90-90 EXCEPT COMPRESSIVE STRENGTH SHALL BE A MINIMUM OF 3,000 PSI AND THE MAXIMUM WATER ABSORPTION SHALL BE LIMITED TO 7.0 PERCENT. 2. THE CONCRETE WALL UNITS SHALL HAVE ADEQUATE FREEZE THAW RESISTANCE IN ACCORDANCE WITH ASTM C666- 90, MODIFIED TO 50 CYCLES. 3. EXTERIOR DIMENSIONS MAY VARY. CONCRETE WALL UNITS ARE REQUIRED TO HAVE A MINIMUM OF 0.67 SQUARE FOOT FACE AREA. 4. COLOR AS SELECTED BY ARCHITECT FROM MANUFACTURER' STANDARD SELECTIONS. 5. FACE PATTERN: GEOMETRY: BEVELED OR STRAIGHT; TEXTURE: SMOOTH OR SPLIT ROCK FACE. 6. THE CONCRETE UNITS SHALL BE POSITIVELY INTERLOCKED WITH INTEGRAL CONCRETE SHEAR CONNECTIONS. 7. ANCHOR DIAMOND UNIT DIMENSIONS SHALL NOT VARY MORE THAN +/- 1 /16 INCH FROM THAT IN ANY MOLDED DIMENSION. B. GEOSYNTHETIC REINFORCEMENT: POLYESTER WOVEN FIBER GEOGRID, POLYETHYLENE EXPANDED SHEET GEOGRID, OR POLYPROPELENE WOVEN GEOTEXTILE FOR USE AS SOIL REINFORCEMENT. C. DRAINAGE AGGREGATE: FILL BETWEEN UNITS SHALL CONSIST OF FREE -DRAINING, COARSE AGGREGATE IN ACCORDANCE WITH ASTM 448-86; STANDARD CLASSIFICATION FOR SIZES OF AGGREGATE FOR ROAD AND BRIDGE CONSTRUCTION, DESIGNATION 57, 67, 6, 7 OR 8. D. BACKFILL: THE FILL SHALL CONSIST OF OFF -SITE INORGANIC SILTY CLAYS OR SANDY CLAYS WITH LIQUID LIMIT LESS THAN 40 AND A PLASTICITY INDEX (PI) BETWEEN 10 END 20 PLACED IN LIFTS NOT EXCEEDING 8-INCHES AS SHOWN ON THE CONSTRUCTION DRAWINGS. E. DRAIN TILE: PVC SCHEDULE 40 SIDE VIEW ANCHOR DIAMOND PRO 3-WAY BEVELED UNIT 3-D VIEW (NOT TO SCALE) 12 1/2" TOP VIEW _F _F 8 1I/2" 8" 1 T O FRONT VIEW SIDE VIEW ANCHOR DIAMOND PRO STRAIGHT UNIT 3-D VIEW (NOT TO SCALE) (t2 GRANULAR BASE 10" 10" EXTEND GEOSYNTHETIC REINFORCEMENT TO WITHIN 2" OF THE LOWER BLOCK FACE 10" ANCHOR DIAMOND PRO REINFORCEMENT CONNECTION DETAIL (NOT TO SCALE) @I ANCHOR DIAMOND PRO BLOCK ANCHOR DIAMOND PRO BLOCK TYPICAL STEP-UP DETAIL 4 TYPICAL BASE PREPARATION 5 (NOT TO SCALE) (:#) (NOT TO SCALE) CITY OF LA PORTE 604 W. Fairmont Parkway Planing Dept./Engineering Div. La Porte, Texas 77571 281-471-5020 civillrech Engineering, Inc. 11821 Telge Road Cypress, Texas 77429 (281) 304-0200 Fax (281) 304-0210 INTERIM SUBMITTAL DOCUMENT INCOMPLETE; NOT INTENDED FOR PERMITS, BIDDING OR CONSTRUCTION. ENGINEER: MARCUS J. MICHNA P.E. REGISTRATION NO. 84739 DATE: 07/02/04 POND TO PARK PROJECT RETAINING WALL DETAILS (1 OF 2) PROJECT NO: DRAWN: JJAR 220029.10 CHECKED: DATE: APPROVED: JULY 2004 SCALE: SHEET: 16 OF 17 REVISIONS N0. REVISION / ISSUE DATE I 4" TEE DAYLIGHT DRAIN THROUGH WALL DAYLIGHT DRAIN THROUGH WALL FACE f4" DIA. DRAIN TILE (EL. VARIES) a� 2" CUT 2ND COURSE ABOVE GRADE 1ST COURSE ABOVE GRADE 1ST COURSE BELOW GRADE 1- T T T T 2ND COURSE BELOW GRADE L--1--1--1--1--1 F SPACING VARIES 50' MAXIMUM CAP BLOCK DIAMOND PRO BLOCK He 7 FINISHED GRADE SLOPE MAY VARY I 12 INCHES OF FREE DRAINING AGGREGATE I a ..:.`. Other Layers REINFORCEMENT LENGTH I GEOSYNTHETIC REINFORCEMENT 2nd Layer P�-4" DIA. DRAIN TILE (EL. VARIES) 1st Layer SCOUR PROTECTION AS REQUIRED. USE RIPRAP OR PRECAST SLAB IN OUTLET AREA (DESIGNED BY OTHERS) FACE WALL CAP BLOCK DIAMOND PRO BLOCK He 7 RIPRAP --- \ D (VARIES) SLOPE MAY VARY INCHES OF FREE RAINING AGGREGATE GEOSYNTHETIC REINFORCEMENT .i°v '• 1 _ t WRAP PIPE IN FILTER FABRIC TO REDUCE FINES WASHING OUT THE FACE '.. , 4" DIA. DRAIN TILE 12" CONCRETE LEVELING PAD SIDE WALL CAP DIAMOND PRO BLOCK CONCRETE COLLAR AROUND PIPE (BY OTHERS) He 7 T I— T —I--I D (VARIES) SCOUR PROTECTION J AS REQUIRED USE RIPRAP OR PRECAST SLAB IN OUTLET AREA (DESIGNED BY OTHERS) PLACE BOND BREAK' AROUND WALL OPENING FACE WALL SLOPE MAY VARY INCHES OF FREE DRAINING AGGREGATE e: F'W. = ,>,��j�� ��% /M�I0.1/4" DIA. DRAIN TILE SIDE WALL /,ii. •- 612" CONCRETE LEVELING PAD 2'-0" ANCHOR DIAMOND PRO ANCHOR DIAMOND PRO ANCHOR DIAMOND PRO DAYLIGHT DRAINTILE THROUGH WALL THROUGH PIPE OUTLET DETAIL — LOW FLOW THROUGH PIPE OUTLET DETAIL — HIGH FLOW (SCALE 3/8"=1'-0") (SCALE 3/8"=1'-0") SCALE 3 8 =1 -0 a�aoa�a�a�a� FILTER FABRIC BEHIND TWO BLOCKS, EXTENDING BACK 2-FEET NEXT TO EXISTING THE EXISTING STRUCTURE STRUCTURE CAP BLOCK SEE DETAIL 05 CAP BLOCK 1/2" EXP. JT. MATERIAL. FIRST COURSE er ayers Other Layers DIAMOND PRO DIAMOND PRO BLOCK I BLOCK 12 INCHES OF FREE 12 INCHES OF FREE DRAINING AGGREGATE DRAINING AGGREGATE I .•.� O! I Other Layers Other Layers FILTER FABRIC ,. • I :•. + I WATER ELEVATION REINFORCEMENT LENGTH f REINFORCEMENT LENGTH I VARIES I I j GEOSYNTHETIC REINFORCEMENT 2nd Layer ••':.I GEOSYNTHETIC REINFORCEMENT 2nd LayerI I , EROSION D aD aD aD aD aD D "• � ;•'r'. PROTECTION FILTER FABRIC I .�,.. �: :r... .....,.:•: .. .>•,.:.:'..,�::'::''.;;'.. :.�. I jj .�: •.` . :�.�... .. s • .• 1st Layer I 1st Layer .'` ,'.: •' . :. "N'``; •:. ' J 4" DIA. DRAIN TILE (EL. VARIES) FILTER FABRIC BEHIND O o0-\0 1 ...:. �I 4" DIA. DRAIN TILE (EL. VARIES);AI TWO BLOCKS, EXTENDING 00 __ 000�0 I WALL BASE / //�j/�j\///�j/�j\\/// BACK 2-FEET NEXT TO �coOa� • EXISTING NATIVE SOIL \ \� \ \� STRUCTURE THE EXISTING STRUCTURE 6„ LEVELING CONCRETE 6" LEVELINGCP DE SECOND LEVELING PAD COURSE ANCHOR DIAMOND PRO ANCHOR DIAMOND PRO ANCHOR DIAMOND PRO SHORELINE/CHANNEL WALL SIDEWALK ABOVE/BELOW RETAINING WALL WALL ABUTTING EXISTING STRUCTURE (SCALE 3/8"=1'-0") (SCALE 3/8"=1'-0") SCALE 3 8 =1 -0 CITY OF LA PORTE 604 W. Fairmont Parkway Planing Dept./Engineering Div. La Porte, Texas 77571 281-471-5020 ch/illrech Engineering, Inc. 11821 Telge Road Cypress, Texas 77429 (281) 304-0200 Fax (281) 304-0210 DOCUMENT INCOMPLETE; NOT INTENDED FOR PERMITS, BIDDING OR CONSTRUCTION. ENGINEER: MARCUS J. MICHNA P.E. REGISTRATION NO. 84739 DATE: 07/02/04 POND TO PARK PROJECT RETAINING WALL DETAILS (2 OF 2) PROJECT NO: DRAWN: GWM 220029.10 CHECKED: EKO DATE: APPROVED: JAR JULY 2004 SCALE: SHEET: 17 OF 17