HomeMy WebLinkAbout09-4804 OAKHURST DR & WESTVIEW DR DRNG, SS IMPVS & SVC RELOCATEDEER PARK
APO\
Q
PROJECT LOCATION
SEE INSET
NSET
N.T.S.
Z
� IBAY ST.J
S. "Y" ST.
a
x
MORGAN'S
POINT
i-n BARBOUR'S CUT BLVD.
L WE�
(O !!II
LOCATION MAP
Not to Scale
HARRIS COUNTY KEY MAP: 580-L
SHOR i CRES
GALVESTON
BAY
• w •
CLP Project No. 2009-4804
SHEET INDEX
SHEET
NUMBER
SHEET TITLE
1
COVER SHEET
2
OVERALL LAYOUT
3
DRAINAGE AREA MAP
4
OAKHURST PLAN & PROFILE
STA. 0+00 TO STA. 6+00
5
OAKHURST PLAN & PROFILE
STA. 6+00 TO GALVESTON BAY
6
WESTVIEW DRIVE PLAN & PROFILE
STA. 0+00 TO STA. 5+60
7
SW3P PLAN
8
STORM SEWER DETAILS
g
STORM SEWER DETAILS
10
STORM SEWER DETAILS
11
WATER LINE DETAILS
12
SANITARY SEWER DETAILS
13
SW3P DETAILS
14
TRENCH SAFETY
j................ *.
RODNEY LEE SLATON
..........eozse ........�
�I �O.c� :f,FG/STERF�•' F•k's
,�1 FSS/0 ... •E�Css�
The seal pearing on
this document was
authorized by
RODNEY LEE SLATON
P.E. 90298, on
IQ)-aQ- 10
MAYOR PRO-TEM
Daryl Leonard
COUNCIL
Mike Mosteit
Chuck Engelken
Tommy Moser
Louis Ribgy
Mike Clausen
John. Black
John Zemanek
CITY MANAGER
RON BOTTOMS
2009-4804
SHEET 1 OF 14
_.
BEGIN BASELINE
1�, OF ROAD
STA. 0 37
N=13799718.58
E=3233118.4640
I) I REMOVE
EXIST.
24" RCP
UI•f•
EXIST. ' 4'x3' RCB
SAN. SWR. M.H. #1389
STA.-0+63 R35' EXIST. AT&T LINE-
RIM=9.63,FL=3.60 EXIST., s
E
wax=w
of-rcl-sa
t-,-
>_^
¢O
,.Z, yF
_>
Nd
X
¢
ACE
¢�
XX
WhhwW
1-
E3O
ww
w
O�O
WW
W
�v
H
0
RIGHT-OF-WAY NOTE
1. OAKHURST RIGHT-OF-WAY IS 80' WIDE BETWEEN
SOUTH BROADWAY AND WESTVIEW DRIVE.
2. OAKHURST RIGHT-OF-WAY IS 60' WIDE BETWEEN
WESTVIEW DRIVE AND CRESCENT SHORES.
3. OAKHURST RIGHT-OF-WAY IS 65' WIDE BETWEEN 4. 4.
CRESCENT SHORES AND GALVESTON BAY.
5. WESTVIEW DRIVE RIGHT-OF-WAY IS 90' WIDE.
6. CRESCENT SHORES DRIVE RIGHT-OF-WAY IS 30' WIDE.
w w z
> J_
¢ m3 °: v°a; 3 E5 ma a- o �rc ¢ w4
a: w .-a x Vld
F F 14- W F-1- 1-t- h 1-h
w w 0 NN> w VIA wwo ,N-,N .yr 0w ,2z VRA w foul
xa xa x x x �a� x X><wx xttx xX x x� xo xK x X`"x
W I- W I- W W W W W w W talJ 2L! W I- W SEE W W I- W 0. ,.,., W W W
PROP. TYPE "E" INLET PROP. TYPE "A" INLET PROP. S.S. M.H. #1
S.S. NOTE STA. 2+01 L22'
PROP. 8" PVC
STA. 0+19 L24' STA. 1+19 L23' RIM=8.67 Sip 26 SAN. SWR.
PROP. TYPE 2 PROP. 21 LF 36" HDPE EXIST. 6' WATER N
JCT. BOX STM. SWR. @ 0.20% VERIFY LOCATION
EXIST, SAN, SWR. O
PROP. S.S. M.H.#3
STA. 5+85, L23', RIM=9.58
E,W FL=5.44
PROP.
X a, Z TYPE "A" INLETa, F1 X
U> W STA. 5+69 L21'� d
PROP. S.S M.H.#2 = & 21 LF 18" HDPEM a f a
STA. 3+86 L23' ' �� STM. SWR. @ 0.25%MG XX X^ X X
RIM=8.87 W WW W Ww Wv W W
SEE
S,E,W; FL=5.17 PROP. TYPE "A" INLET S.S. NOTE
STA. 4+02 L20' PROP. 811 Q PROP. 20 LF 1811 PVC SDR 26
HmPE @ 0.25% ! I Q
EXIST RDW "o,•s--- -�--.- -- __- - r r -- O- -- - - - .._
GAS, LINE
_�-EXIST, S.S. LATERAL PROP. 14 LF 36" HDPE-A IT LINE
LU
EXIST. S.S. 8' COVER - -{- - -
\ - \LATERAL 30' COVER - - - - - - - - - - -
�r------�+oo-- 11 - -_�- - - - - - - - - --%--
�_ ..--- -•-' ....-...-.-.. ... •.: _GAS
G
SAS GAS
... 1 . S GAS
S -- GAS B-- GAS -. • AS GAS GAS
.• GPS -'-- GAS -- GAS --' GAS GAS GAS 5
GASY,'-' GA '' �= • EX T. B SHES EXIST.
OHE- •ii;.s WATERLINE
•- ® 9
�'(-EXIST.
�? S.S. M.H. #1391A
PROP. 6'x4' RCB STA. 2+61, R10'
- - - - - - - RIM=11_02,FL=36Q-_„,--PROP. -24" 14-EFHDPE- - _ �y3 PROP. TYPE 2
I EXIST. ROW PROP. 20 LF 24 14511E STM. SWR. @ 0.20oa X& JCT. BOX
STM. SWR. @ 0.20% W STA. 3+86
V " PROP. TYPE "E" INLET PROP. TYPE "A" INLET PROP. TYPE "A" INLET
STA. 0+19 R22' STA. 1+19 R23' STA. 2+86 R14'
EXIST. S.S. S.. LATERAL J
EXIST. W.L. ---�I LATERAL 30' CDVER 17' COVER L
LATERAL �-�- --6�----- -
... _.. ..._... . _
ST, 18' RCP; 'm -- --•
GAS GAS GAS GAS --- GAS AS GAS _ _
GAS ----'-_ -
A� �-'T• - - - EXI . W,L SVC.
EXIST. W.L. SVC.
EXIST. PROP. 14 LF 24" ROP. 452 L.F.
S.S. M.H.#1391
STA. 4+86
M=11,33, FL=5.00 HDPE STM. SWR. 6'x4' RCB @ 0.1% ZONE AE
I
I
(IST. @ 0.20% PROP. 12 LF 24" HDPE (EL. 12) e SS LI SWR. STM. 0.20%
PROP. TYPE "A" INLET @
WTI STA. 4+02 R14' & TYPE "A" INLET
PROP. 20 LF-15" DUCTILE STA. 5+69 R12'
IRON PIPE SLEEVE ON SAN. SWR.
X W wWM ,,I r ma_ p. Y WX• W Wa;wV rWWa K W X 0 W W WW K W d K W w x w F'1 L.1 n 0_ wZza:w
Q W 0.z.N'�- t x t=:1 6K t=a XC3mw•'n"Ka.J '> MW x r, > O W J J JW i.., W W 0 V O W dx E Wx D w x r x a a f- t- 3 a a z
J LY. w O 3• a' '-'-• +,1
A �- '�~WOO. �m �¢v, rfn rNEw' Y ry ti q ¢ w E s r o: w M M ,' w t- -f' m P- Q�-r'F
x¢�Ar�h.a.r w x XXMMx0Xa ¢ irw x f' f Wa a 3 x x o X Xw¢ A wvf�X
0 WW WW¢ x Wd' W w h~¢ ¢ ¢_JJ �'^ W W J d ,- •Xy"•
!- W F,N-,-, F w w w K X wi- X w rvN-, K K "'6 ,- .N-. ¢ W ti WFF O y ,'•',jj,+,�� w Z
,~�-, XW X W U U U W o Ur W W W U U t',' w W F X QX LLI W X U
W W 1- W W W S S r~N-, S•N.' W ,~N-. W m W W ,`-, ''' F
,N-, ,y. X ,~N-, 1
W W W V W W W Wy N
F W N W
w W W W
W 3
¢
w d
z
_3IJ
w wM w w
w aW
a
Z��
��� x>
..,
z �. Wd M at
U
d
E
cam-
L,UO/,
www, w -2 °-
I ¢OLO�
,N-.3a 3E.a3m3
twu
vaz
0 �
v
ti wN ON aNN-rNw
w w'''
/t
PROP. TYPE "A"
w-niJ
WOw
WWWWMWOW
JOC
Ltal
XWXQX 6XX QX6
Wl,-WI-WI-WWFWt-
XX
W W
INLET & 20 LF-24"
IOC¢
��X
C��/W
XXXXXXX WX
WW�WWWWWW
HDPE @ 0.20%
�
�1
PROP.
EXIST, S'
N. SWR,
6'x4' RCB
VER FY6L CATION WATERLINE
The Contractor shall be the operator as defined by TPDES General Permit. The contractor shall
comply with all TPDES General Permit requirements to include preparation, maintenance and
implementation of the SW3P.
The Contractor shall submit all notifications and pay all associated fees required by the TPDES
General Permit. The contractor shall provide the City Inspector copies of any submitted
notifications and associated fee checks.
The Contractor's temporary control measures shall be installed and maintained throughout the
construction contract and coordinated with proposed or existing permanent pollution control
features to assure effective and continuous water pollution control throughout the construction
and post construction period. The Contractor will maintain and inspect the temporary control
measures in accordance with the TPDES General Permit requirements.
10' SAN. SWR.
EXIST. ROW _
--- - -----------
--- ... ..._..._.. ..._..._..._..._..._...-_...-...._... PVC SAN. SW
... ... - STrI B'
W
7 E ST. W.L. SVC.�� L -
J--�<- T----------------------�-i
_ - - -
,... ... s _
U = . •. ,. -.- _ -_ _ -_ _ _- _ __ _ __ _ __ _ -_ _ GAS _ __GAS G
GAS GAS--GAS---GAS--GAS--- GAS
Y,, • �'.f'y .
GAS `.Grit S_EXIST. ROW EXIST, a
EXI BRICK WALL S.S. M.H,#1397
Q PROP. 12 LF- 24" HDPE IM=12.21, FL=5.91
STM. SWR. @ 0.20% EXIST. 6' WATERLINE i I
I ZONE AE VERIFY LOCATION I I
(EL, 13)~ti, 3
I W�i
PROP.
TYPE "A" INLET
STA. 6+57 R15'
a
r
Y
rc
¢
a
y
XX6
X
XQ
WWw
W
WU1
PROP. TYPE 2 JCT.BOX
STA- - - 8+42 _ - - - EXIST. --
I
END BASELINE AT
EXIST, BRICK WALL END OF RIPRAP
______ -�-- __ STA.9+75
- - - - - -+00- - - - - - N=13800415.7840
E=3232334.6000
PROP. 6'x4' RCB PROP. OUTFALL. TO
_ _GALVESTON BAY OUTFALL
- - EXIST. ROW tF'-_-_-- I
TA. 9+75, FL=3.05
M#1399.RIM .06
ZONE AE I ZONE VE ZONE VE ' ZONE VE
N3 (EL-13) I (EL. 15) (EL. 15) (EL. 17)
IW� I
a. W
� �
W
z
�
w
z
wa m X'
>� " Wa
a
U
x
w
M
�
a3 as
' /� '
�'3 �
-Zxt�WZlaS
�rxnac.lvcsn
W
>
W
x
Y W
Zc�
a
a
�¢
E
F
roJz�a
�,'n-,-,
A
w
W
d
W
U
X
F
Y
Qi"'•
.�..
,-
6
,N-,
F .N-,
,y-,
wy(U�t'ly_•�l'U
w
¢
O
F 0
,V-,
3
,V-,
ryl" ,y-, ,y-,W
1-
,y-,
"
W
:�-, W
LLS O W
W"X,..' ,M•
f"
,XJ
U
ti
W
w W
Ki.:a
w
w
X4 X X
W W W
w
X
W
F-
N.Xy
IaWyI
1-
J
W
w
W
WLj
WX.�i`
X
tY
y'
W
W
W
W
W
W
W
U
wW W
X
W3
W -
N
Z
m
E-
Q x
rn
y
W
U
X
W
X
X
W
X
W
a
s>n O
w
a
M
W W
w
W
GENERAL UTILITY NOTES:
1. CALL 713-223-4567 FOR LOCATION OF UNDERGROUND FACILITIES 72 HOURS PRIOR TO ANY EXCAVATION IN THE
AREA.
2-LOCATION OF UTILITIES SHOWN ARE APPROXIMATE. IT IS THE CONTRACTORS RESPONSIBILITY TO LOCATE ALL
UTILITIES (PUBLIC AND PRIVATE) PRIOR TO COMMENCING WORK. THE CONTRACTOR IS FULLY RESPONSIBLE FOR ANY
DAMAGES CAUSED BY HIS FAILURE TO LOCATE AND PRESEVE THESE UTILITIES WHETHER UNDERGROUND. ABOVE
GROUND OR OVERHEAD. TO ARRANGE FOR LINES TO BE TURNED OFF OR MOVED CALL CENTERPOINT AT
713-223-4567.
3. CONTRACTOR SHALL CONTACT ALL OF THE FOLLOWING PHONE NUMBERS FOR LOCATION OF UNDERGROUND FACILITIES
72 HOURS PRIOR TO ANY EXCAVATION IN THE AREA.
(UCC HOUSTON) 713-223-4567
(TEXAS ONE -CALL SYSTEM) 1-800-245-4545
(DIG-TESS) 1-800-344-8377
4. TELEPHONE AND TELEVISION CABLES MAY EXIST UNDERGROUND OR OVERHEAD THROUGHOUT THE PROPOSED PROJECT
AREA. CONTRACTOR SHALL CONTACT "DIG-TESS" at 1-800-344-8377 AT LEAST 48 HOURS PRIOR TO BEGINNING
ANY CONSTRUCTION FOR LOCATION AND MARKING OF THESE UTILITIES.
5.LOCATIONS OF CENTERPOINT ENERGY MAIN LINES (TO INCLUDE UNIT GAS TRANSMISSION, AND/OR INDUSTRIAL GAS
SUPPLY CORORATION WHERE APPLICABLE) ARE SHOWN IN AN APPROXIMATE LOCATION ONLY. SERVICE LINES ARE
USUALLY NOT SHOWN. THE CONTRACTOR SHALL CONTACT THE UTILITY COORDINATING COMMITTEE AT 713-223-4567
A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION TO HAVE MAIN AND SERVICE LINES LOCATED.
A. WHEN CENTERPOINT ENERGY PIPE LINE MARKINGS ARE NOT VISIBLE CALL
713-967-8037 (7:00 AM TO 4:30 PM) FOR STATUS OF LINE LOCATION REQUEST
BEFORE EXCAVATION BEGINS.
B. WHEN EXCAVATING WITHIN EIGHTEEN INCHES (18') OF THE INDICATED LOCATION OF
CENTERPOINT ENERGY FACILITIES, ALL EXCAVATION MUST BE ACCOMPLISHED USING
NON -MECHANIZED EXCAVATION PROCEDURES.
C. WHEN CENTERPOINT ENERGY FACILITIES ARE EXPOSED, SUFFICIENT SUPPORT MUST
BE PROVIDED TO THE FACILITIES TO PREVENT EXCESSIVE STRESS ON THE PIPING.
9.THE CONTRACTOR IS FULLY RESPONSIBLE FOR ANY DAMAGES CAUSED BY HIS FAILURE TO EXACTLY LOCATE AND
PRESERVE THESE UNDERGROUND FACILITIES.
1O.OVERHEAD ELECTRICAL LINES MAY EXIST ON THE PROPERTY. WE HAVE NOT ATTEMPTED TO MARK THOSE LINES
SINCE THEY ARE CLEARLY VISIBLE. YOU SHOULD LOCATE THEM PRIOR TO BEGINNING ANY CONSTRUCTION. TEXAS
LAW, SECTION 752, HEALTH & SAFETY CODE FORBIDS ALL ACTIVITIES IN WHICH PERSONS OR THINGS MAY COME
WITHIN SIX (6) FEET OF LIVE OVERHEAD HIGH VOLTAGE LINES. CONTRACTORS AND OWNERS ARE LEGALLY
RESPONSIBLE FOR SAFETY OF CONSTRUCTION WORKERS UNDER THIS LAW. THIS LAW CARRIES BOTH CRIMINAL AND
CIVIL LIABILITY. TO ARRANGE FOR LINES TO BE TURNED OFF OR MOVED CALL CENTERPOINT AT 713-207-7777.
11. THE LOCATIONS OF SOUTHWESTERN BELL TELEPHONE (SWBT) COMPANY FACILITES ARE SHOWN IN AN APPROXIMATE
WAY ONLY. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION PRIOR TO COMMENCING WORK. HE AGREES
TO BE FULLY RESPONSIBLE, FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY HIS FAILURE TO EXACTLY
LOCATE AND PRESERVE THESE UNDERGROUND UTILITIES.
A. THE CONTRACTOR SHALL CALL 1-800-344-8377 A MINIMUM OF 48 HOURS PRIOR TO
CONSTRUCTION TO HAVE UNDERGROUND LINES FIELD LOCATED.
B. WHEN EXCAVATING WITHIN EIGHTEEN INCHES (18") OF THE INDICATED LOCATION OF
SOUTHWESTERN BELL TELEPHONE FACILITIES, ALL EXCAVATION MUST BE ACCOMPLISHED
USING NON -MECHANIZED EXCAVATION PROCEDURES. WHEN BORING THE CONTRACTOR
SHALL EXPOSE THE SOUTHWESTERN BELL TELEPHONE FACILITIES.
C. WHEN SOUTHWESTERN BELL TELEPHONE FACILITIES ARE EXPOSED THE CONTRACTOR
SHALL PROVIDE SUPPORT TO PREVENT DAMAGE TO THE CONDUIT DUCTS OR
CABLES. WHEN EXCAVATING NEAR TELEPHONE POLES THE CONTRACTOR SHALL BRACE THE POLE
FOR SUPPORT.
GENERAL NOTES:
1. NOTIFY UTILITY COMPANIES 3 DAYS PRIOR TO BEGINNING CONSTRUCTION IN VICINITY OF THEIR UNDERGROUND AND
OVERHEAD UTILITIES. TELEPHONE NUMBERS ARE SHOWN BELOW:
RELIANT ENERGY 713-207-7777
TEXAS ONE CALL 1-800-245-4545
SOUTHWESTERN BELL 713-861-9784
CENTERPOINT ENERGY 713-207-6819
2.
VERTICAL AND HORIZONTAL LOCATIONS OF EXISTING UTILITIES, INCLUDING WATER, ARE APPROXIMATE. CONTRACTOR
TO LOCATE AND PROTECT AND REPAIR AT HIS EXPENSE ANY UTILITIES AND SERVICE LINES DAMAGED BY HIS CREWS
OR THOSE OF SUBCONTRACTORS. CONTRACTOR SHALL SHORE ALL POLES WHICH IN OPINION OF UTWTY COMPANY
REQUIRE SHORING. COST SHALL BE INCIDENTAL TO OVERALL PROJECT COST.
3.
CONTRACTOR SHALL TAKE CARE WHEN EXCAVATING IN AREAS WHERE THERE ARE EXISTING UTILITIES. NOTIFY
OWNER/ENGINEER IMMEDIATELY UPON ENCOUNTERING UTILITIES NOT SHOWN ON DRAWINGS.
4.
CONTRACTOR TO PLAN AND PERFORM ALL WORK TO ALLOW FOR SAFE TRAFFIC AT ALL TIMES DURING
CONSTRUCTION, PROVIDE AND MAINTAIN ALL NECESSARY SIGNS, FLASHERS, BARRICADES AND FLAGMEN AS PER
TEXAS STATE DEPARTMENT OF HIGHWAYS AND PUBLIC TRANSPORTATION IN CONFORMANCE WITH PART VI OF THE
"TEXAS MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES' (TEXAS M.U.T.C.D. MOST RECENT EDITION) DURING
CONSTRUCTION. COST FOR THIS WORK TO BE INCLUDED IN LUMP SUM PRICE OF TRAFFIC CONTROL
5.
ALL WORK SHALL BE CONDUCTED WITHIN THE RIGHT -OF WAY AND/OR EASEMENTS SHOWN UNLESS OTHERWISE
APPROVED BY THE OWNER AND/OR ENGINEER.
6.
CONTRACTOR IS RESPONSIBLE FOR STAKING AND LAYOUT OF THE WORK IN ACCORDANCE WITH THE PLANS AND
FURNISHED CONTROL POINTS.
7.
EXISTING PROPERTY CORNERS ARE NOT TO BE DISTURBED. THOSE REMOVED DURING CONSTRUCTION SHALL BE
RESET UNDER THE SUPERVISION OF A REGISTERED SURVEYOR AT NO COST TO OWNER.
8.
EXCESS EXCAVATED MATERIAL SHALL BE DISPOSED OF PROMPTLY. CITY HAS THE OPTION OF TAKING ANY SALVAGED
MATERIAL AS DEEMED NECESSARY.
9.
CONTRACTOR SHALL ASSIST OWNER IN NOTIFIING BUSINESS ESTABLISHMENTS OF ANY SERVICE INTERRUPTIONS.
10.
CONTRACTOR SHALL TAKE CARE WHEN WORKING WITHIN PERMANENT AND WORKING EASEMENTS. ALL DAMAGED
PLANTS, TREES, SHRUBBERY, FENCE AND STRUCTURES WHICH ARE TO REMAIN SHALL BE REPAIRED OR REPLACED
WITH EQUAL OR BETTER ITEM. ANY LANDSCAPE AREA DAMAGES SHALL BE REPLACED TO EQUAL OR BETTER
11. RBN%KING AND BACKRLL SHALL BE PER DETAIL SHOWN IN THESE PLANS.
12. WORK ON ITEMS NOT SPECIFICALLY CALLED OUT IN BID DOCUMENT SHALL BE INCIDENTAL TO OVERALL PROJECT
COST.
13. WORKING AREAS SHALL BE ONLY THOSE AREAS DESIGNATED BY OWNER. ANY ACTIVITY BEYOND THESE PREMISES IS
STRICTLY PROHIBITED. INGRESS AND EGRESS OF MEN AND EQUIPMENT SHALL BE THROUGH APPROVED EASEMENTS
ONLY. CONTRACTOR TO COORDINATE WITH OWNER PRIOR TO CONSTRUCTION.
14. ALL REMOVAL OF ASPHALT ROADWAYS, AS DESIGNATED BY CITY TO BE OPEN CUT SHALL BE PROPERLY SAW CUT,
AND THEN BACKFILLED PER DETAIL SHOWN.
15. CONTRACTOR SHALL BE RESPONSIBLE FOR HAULING AND DISPOSAL OF THE EXISTING AND PROPOSED EXCAVATED
MATERIAL AT THIS OWN EXPENSE UNLESS OTHERWISE DIRECTED BY THE ENGINEER TO DELIVER TO A LOCATION
WITHIN ONE MILE RADIUS FREE OF CHARGE.
16. NO EXCAVATION AREA SHALL BE LEFT OPEN DURING NON -WORKING HOURS. ALL EXCAVATION OVER 2 FEET IN
DEPTH SHALL BE PROTECTED BY BRIGHT ORANGE SAFETY FENCING.
17. CONTRACTOR SHALL NOTIFY THE CITY OF LA PORTE AT 281-471-9650 TWENTY-FOUR (24) HOURS PRIOR TO ANY
UTILITY COORDINATION REQUIRED.
18. ALL SIGNS REMOVED SHALL BE RESET UNLESS OTHERWISE NOTED. ANY SIGN DAMAGED SHALL BE REPLACED WITH
NEW SIGN AT NO COST TO OWNER.
19. ALL GRASS AREAS AFFECTED BY CONTRACTORS OPERATIONS SHALL BE LEVELED TO ORIGINAL CONDITIONS &
HYDROMULCHED.
20. ADJUSTMENT OF VAILE BOXES, REMOVAL OF TREES, RELOCATION OF STREET SIGNS, AND ANY OTHER ITEM NOT
SPECIFICALLY CALLED OUT IN THE BID DOCUMENT SHALL BE INCIDENTAL TO OVERALL COST OF PROJECT.
FLOOD STATEMENT
THE SUBJECT PROPERTY APPEARS TO LIE OUTSIDE OF THE 100-YEAR FLOOD
PLAIN PLAIN ZONES "AE" & "VE", AS PER THE FLOOD INSURANCE RATE MAP.
COMMUNITY PANEL NO. 48201CO945L DATED JUNE 18, 2007. WARNING: THIS
STATEMENT IS BASED ON SCALING THE LOCATION ON THE ABOVE REFERENCE
MAP. THIS INFORMATION IS TO BE USED TO DETERMINE FLOOD INSURANCE
RATES ONLY, AND IS NOT INTENDED TO IDENTIFY SPECIFIC FLOOD CONTITIONS.
TEMPORARY BENCHMARKS
1. S.E. CORNER AT&T CONCRETE SLAB EASTERN MOST,
BLACK "X" MARKED.
ELEV.=10.80
2. 8d NAIL & SHINER, AT NORTH SIDE OAKHURST &
CENTERLINE OF WESTVIEW.
ELEV=11.78
3. 3'a" I.P. (PROPERTY CORNER) LOCATED AT S.E. OF THE
INTERSECTION OF CRESCENT DRIVE & OAKHURST.
ELEV=11.83
SANITARY SEWER NOTE:
REMOVE LATERALS, CUT AND PLUG, RECONNECT
TO PROPOSED SANITARY SEWER LINE OR M.H.
RODNEY LEE SLATO.
......... ........
90298
�i� o,N �FG/ER�a.\��_,�
,1t SSIONAL
The sea on
this document was
authorized by
RODNEY LEE SLATON
P.E. 90298, on
10-aD-/0
ILI
W \A E
/ Mq
0 30 60
SCALE: 1 "= 30'
LEGEND
FOR (ASPH"
FOR (LIMESTONE)
FOR (DIRT)
FOR (CONCRETE)
FOR (SHELL)
CMP _ _ _ _ _ _ _ _ _ _ _ _ _
RCP _ _ _ _ _ _ _ _ _ _ _ _ _
C.L. DITCH--------
TOB _ _ _ _ _ _ _ _ _ _ _ _ _ _
AT&T LINES
GAS LINES GAS - GAS - GAS
OVERHEAD ELEC. - OHE OHE - OHE
BRICK WALL
WOOD FENCE
FILTER FABRIC
TREES
� �
BUSHES
ASPHALT ®CONCRETE
�;.i: :.a
GRASSEl
DIRTIN
LIMESTONE
��
AT&T
BOXES