Loading...
HomeMy WebLinkAboutANIMAL SHELTER FACILITYLOCATION MAP OF A PROP. 16 LF-18" HDPE - _ tip'OFF FIFO O MH -- , _. (12.473 ACRES) SAN SWR MH , N.RIM=22.62 S. ►E 6^PVC=16.98 ` . PROP. 6CHAINLINK FENCE N.W. IE 6"PVC=16.98 FIFO ry�ti� I ~g co �� X P OFF 9 N OFF PROPERTY LINE IF - TRACT. A -_.OFF . I. Ix 323,A PAVING NOTES 5.912 ACRES) _{,� - - x- * ---- rry :. EXIST. 10' REAR SETBACK v ( AC• o� *`� �., 1. 6:" CONCRETE PAVEMENT W/ #3 1.403 _ ti "� REBAR ON 18 CENTERS. Z ti Q m , , °,, 2:. 6 LIME TREATED BASE ® 8% BY J g B Oo I PROP. �,X1Z �., WEIGHT. gCONC�„ 3:.EXPANSION JOINTS TO BE EVERY 40 FEET. a to I PROP. 6" CO P ME *',+, A„ CONTRACTION JOINTS TO BE EVERY 40 FEET. CL 0 W/ #3 'REBAR 18 '*.' ALTERNATE EXPANSION JOINT AND CONTRACTION a• 4 OF - • ?., ° H.W.Y. '. °�, D W W 6" LIME STABILIZ BA +% Oil RPZ BACKFLOW PREVENTOR JOINT EVERY 20 FEET. 4. ° ./ ,` ;• U (8% BY WEIGHT) * h, 49 PROVIDE 12" CONC. HEADER AT DRIVEWAY/ASPHALT d .. . - , _ d 444 IF -- - ,-, . /-TOP ,,`, •; ROAD TIE IN. = 23.48 (TYPO) FA So as 014,0NM FFt L.P.S.M.4#1-1.A PORTE 1952 OFF ._ .::..._.: ,....._. ;i. ' -Y-------Y___]L--Y .--Y-_X..--3____]L__ STM. SWR. ®0. 5% OFF PROP. 10 CONC. BRASS DISC IN CONC.- ELEV. _ 21.86 ('01 ADJ.) AT PR P. 33 LF-8 HDPE PAD ,. » LOU �- o J to o El SWR. ®0.25% N. SIDE OF SPENCER HWY. ( APPDX. 509) AND E. DO PROP. TYPE 1 - JUNCT. BOX Q '`AB PROP. 5' SIDEWALK SIDE OF ENTRANCE RD TO AIRPORT LOCATED W. OF Op I i 1© ® 1© 16 TEXAS AIR NATIONAL GUARD PROPERTY. W/ GRATE INLET T TG 23.15 w Z R % I ,OFF N , m I w , x CL FL = 20.34 (N, S & E) z 4 GATE t T•B•M•#1: FILL IN DITCH AREA m Z z - - o - w N. RIM SAN. SWR. M.H. AT S.W. COR. OF ANIMAL z _ o Y 00 5 GATE x ; % z v d 3.11 SHELTER SITE. AT N.E. COR. OF SPENCER HWY. AND C 7cwmTL� 3339d"I � '..ENTRANCE RD. TO AIRPORT LOCATED E. OF TEXAS AIR B " PROP. TYPE »A., INLET _ � I N N ; PR P PROP. 49 LF 18 HDPE X � , TG 22.96 STM. SWR. ®EXIST. W j oo II ! NATIONAL GUARD PROPERTY. ELEV. 22.33 ('01 ADJ.) FL = 20.71 (W) GRADE rn w w 10 H CRAMP _ irsomi IF e-"FUTURE PROPOSED PARKING CALCULATIONS 0 0 IF IFz 11 1© C2 / p: O BUILDING RESTRICTII U I ` PROP• TYPE "A" INLET I o o LINE (BRL) MINIMUM OF PARKING SPACES REQUIRED 16 _`fG 22.55 Z o 0 o a 10 GATE o FL = 20.83 (SW & SE) NUMBER OF PARKING SPACES = 18 rn z I COVERED WALKWAY N NUMBER OF ADA SPACES = 2 _ E I = ;OFF „ - . _ . C PROP. 43 LF-6 PVC SAN. SWR. SERVVCE LEAD ® 1.007 x FLOOD STATEMENT 1-8 x6 TEE = UIG IG UIG UIG IF UIG HFIN " PROP• 31 LF-18" HDPE Z I PROP. CONC. IDEWALK THE, PROJECT IS LOCATED ENTIRELY WITHIN FLOOD 1-6 45 BEND PROP. 3,100 SF OFFICE BUILDING I ZONE X PER FIRM MAP 48201C0940, SUFFIX " L 1-CLEAN OUT (FL = 19.50 E & W) STM. SWR. ® EXIST.FF" t xnez FL = 18.75 (E)(AT MAIN LINE) GRADE a I +0.a FF = 24.48 „ DATED JUNE 18, 2007 HR RAMP PROP. 6" CON PAVEMEN * DETENTION NOTE PROP. 2" POLYETHYLENE SERVICE CONNEC110N N W 3 REBAR 18" E.W. B _- "-- "-.-- .- _.---------._ _ W �� Y _ / # _ _ _ DETENTION NOT REQUIRED DUE TO ENTIRE AREA OF 1 _r;��x2 SADDLE F a - jai 7VH LIME" 1L-i`LECS BRA AIRPORT RUNOFF ALREADY WAS CONSIDERED IN THE 1 2� METER 8% BY WEIGHT 1-2' BACKFLOW PREVENTOR W ( ) j iaa WIDENING OF SPENCER HIGHWAY. - o a PROP. CONC. SI EWALK OF PROP* 1 IRRIGATION LINE ZONING PUD BY CITY OF LA PORTS _1-6"x1" SADDLE 0 1-1 METER 1-1" BACKFLOW PREVENTOR ° ti W PROP. 10 LF-12" HDPE OWNER/DEVELOPER STM. SWR ® 0.25% oD 'A CITY OF LA PORTS PROP. 6"x6" TEE (MJ) A # 1-6" G.V. W/ BOX �„ Q sr•�fit O HC1 1-FIRE HYDRANT (4.5' BURY) , \F z o o a o 0 o a o C� + `4 OF T�Ba6 PP TOP = 23.98 J pd y�P� .... ek�s0rta 1-8" 90' BEND _ n6 �ti ti6`° ��� *:. *Bre 3 LF-8" HDPE , > oo I , , x 33" TYPICAL 9'x18' ¢ * ti. 9. ti ti x 0 4, •. * / PROP. 5 x5 HR TYPICAL 14 x18 B BOB SAMUEL ENG 1-8" CAP o PARKING W CONC. ; LANDING w ADA / _ N N REMOVE 6' CHAIN �' r 75i94 O X' LTR IST. SAN. SWR. MH CAR STOPS o * * IE 36" HDPE = 17.96 iOr�O� QFGISTERF�'���®® 9a W • = 2z.33 (TBM #,> LINK FENCE �'Fss....PROP. DUMPSTER W/10 x10 CONC. PAD = 15.66 6" E, W. & N (x ty TONAL �04 10' DOUBLE GATE W/ 6' WOODEN FENCE P1,3 ( ) " Xti'ti x 6' yh titi9ry The seal appearing on EXIST. 0' FRONT SETBACK O 22 ELECTRIC ROLL GATE W/ KEYPAD L B" VCP-SPN.SNR- x EXIST. CHAINLINK FENCE W/ 3-STRAND BARBED WIRE thin document was authorized by 806 SAMUEL ENG Fxlsr 19" avc wATERI iNF a1 P.E. 519 on EXIST CHAINLINK FENCE W/ 3-STRAND BARBED WIRE GV w * MIS 1' (TYPO) PROP. LINE PROP, LINE 10.70' ry yti FIFF" WWI PP ... ...... .. x IR 1/2" _ Dwrl oKD APP <. 1. 4 + -, - - PP • •• 11/7/12 let SUBMITTAL AM RLS RLS F. O 6 CHAIN LINK FENCE W/ 3 STRAND BARB WIRE - -- _ 11 /4/14 ADDED 51 SIDEWALK W TH 12%12 PADS AM BSE BSE �m.ao PROP. 5' CONC. SIDEWALK �C► STM MH L CAD FILE N.RIM=20.63 p T p /emu ��/ �/ PROP. 10 GATE F THRT=19.85 STREE I SPENCER H)V�l YYA I OOp ENGINEER - RODNEY SLATON. P.E. PLOT DATE 604 W. E, RMONTTEXAS 11 12 © CENTER POINT SERVICE CONNEC110N W. MAIN PROP. 8' CONC. SIDEWALK a� LA PORTS, TEXAS 77s�1 DwN S•24°RCP=15.33 EXIST. CONC. STREET W/ CURB & GUTTER AWN 120/208 3� OFFICE 281-470-5060 100' R.O.W. E-MAIL slatonr®laportetx.gov CKD BSE +Ewm SITE PLAN ACCURACY CERTIFICATE CITY APPROVING AUTHORITY CERTIFICATE APPD 1,. BOB ENG, PE., am registered under the laws of the THIS IS TO CERTIFY THAT THE CITY OF LA PORTE HAS APPROVED THIS SITE PLAN FOR ANIMAL SHELTER BSE State of Texas to practice the profession of engineering and hereby certify IN CONFORMANCE WITH THE ORDINANCES OF THE CITY OF LA PORTE. SCALE - that the above site plan is true and correct, and that all bearings, distances, I - O PORTE 1 "=20' (HOR) angles, curves, radii, and central angles sre accurately shown on the site plan. BY: JOB N0. - - DIRECTOR,*INGDEMENTSITE PLAN FOR PROPOSED 12-31000037 NOTE: SHEET BY 00060 • . ANIMAL SHELTER " BOB EN R P.E. • EXIST. 4 NATURAL GAS LINE LOCATED ALONG Texas Registration No: 75194 ; : �isM- $*%tie fR ,- y� ' 10901 SPENCER- HIGHWAY C � SOUTH R.O.W. LINE OF SPENCER HIGHWAY. �A l